Search NASA⌕ Search

SEARCH · Search NASA

Results for “DSC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

SU-E-J-105: Trusting Dose Deformation and Accumulation for GYN Brachytherapy

Purpose: In brachytherapy, structures surrounding the target have the potential to move between treatments and receive unknown dose. Deformable image registration could overcome challenges through dose accumulation. This study uses two possible deformable dose summation techniques and compares the results to point dose summation currently performed in clinic. Methods: Data for ten patients treated with a Syed template was imported into the MIM software (Cleveland, OH). The deformable registration was applied to structures by masking other image data to a single intensity. The registration flow consisted of the following steps: 1) mask CTs so that each of the structures-of-interest had one unique intensity; 2) perform applicator — based rigid registration; 3) Perform deformable registration; 4) Refine registration by changing local alignments manually; 5) Repeat steps 1 to 3 until desired structure adequately deformed; 5) Transfer each deformed contours to the first CT. The deformed structure accuracy was determined by a dice similarity coefficient (DSC) comparison with the first fraction. Two dose summation techniques were investigated: a deformation and recalculation on the structure; and a dose deformation and accumulation method. Point doses were used as a comparison value. Results: The Syed deformations have DSC ranging from 0.53 to 0.97 and 0.75 and 0.95 for the bladder and rectum, respectively. For the bladder, contour deformation addition ranged from −34.8% to 0.98% and dose deformation accumulation ranged from −35% to 29.3% difference from clinical calculations. For the rectum, contour deformation addition ranged from −5.2% to 16.9% and the dose deformation accumulation ranged from −29.1% to 15.3% change. Conclusion: Deforming dose for summation leads to different volumetric doses than when dose is recalculated on deformed structures, raising concerns about the accuracy of the deformed dose. DSC alone cannot be used to establish the accuracy of a deformation for brachy dose summation purpose.

60 APPLIED LIFE SCIENCES↗

Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma

Purpose: Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as intermediate endpoints of asthma severity and control. In particular, pulmonary {sup 1}H MRI can be used to provide quantitative lung structure-function measurements longitudinally and in response to treatment. However, to translate such biomarkers of asthma, robust methods are required to segment the lung from pulmonary {sup 1}H MRI. Therefore, their objective was to develop a pulmonary {sup 1}H MRI segmentation algorithm to provide regional measurements with the precision and speed required to support clinical studies. Methods: The authors developed a method to segment the left and right lung from {sup 1}H MRI acquired in 20 asthmatics including five well-controlled and 15 severe poorly controlled participants who provided written informed consent to a study protocol approved by Health Canada. Same-day spirometry and plethysmography measurements of lung function and volume were acquired as well as {sup 1}H MRI using a whole-body radiofrequency coil and fast spoiled gradient-recalled echo sequence at a fixed lung volume (functional residual capacity + 1 l). We incorporated the left-to-right lung volume proportion prior based on the Potts model and derived a volume-proportion preserved Potts model, which was approximated through convex relaxation and further represented by a dual volume-proportion preserved max-flow model. The max-flow model led to a linear problem with convex and linear equality constraints that implicitly encoded the proportion prior. To implement the algorithm, {sup 1}H MRI was resampled into ∼3 × 3 × 3 mm{sup 3} isotropic voxel space. Two observers placed seeds on each lung and on the background of 20 pulmonary {sup 1}H MR images in a randomized dataset, on five occasions, five consecutive days in a row. Segmentation accuracy was evaluated using the Dice-similarity-coefficient (DSC) of the segmented thoracic cavity with comparison to five-rounds of manual segmentation by an expert observer. The authors also evaluated the root-mean-squared-error (RMSE) of the Euclidean distance between lung surfaces, the absolute, and percent volume error. Reproducibility was measured using the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) for two observers who repeated segmentation measurements five-times. Results: For five well-controlled asthmatics, forced expiratory volume in 1 s (FEV{sub 1})/forced vital capacity (FVC) was 83% ± 7% and FEV{sub 1} was 86 ± 9%{sub pred}. For 15 severe, poorly controlled asthmatics, FEV{sub 1}/FV C = 66% ± 17% and FEV{sub 1} = 72 ± 27%{sub pred}. The DSC for algorithm and manual segmentation was 91% ± 3%, 92% ± 2% and 91% ± 2% for the left, right, and whole lung, respectively. RMSE was 4.0 ± 1.0 mm for each of the left, right, and whole lung. The absolute (percent) volume errors were 0.1 l (∼6%) for each of right and left lung and ∼0.2 l (∼6%) for whole lung. Intra- and inter-CoV (ICC) were <0.5% (>0.91%) for DSC and <4.5% (>0.93%) for RMSE. While segmentation required 10 s including ∼6 s for user interaction, the smallest detectable difference was 0.24 l for algorithm measurements which was similar to manual measurements. Conclusions: This lung segmentation approach provided the necessary and sufficient precision and accuracy required for research and clinical studies.

60 APPLIED LIFE SCIENCES↗

Generic and robust method for automatic segmentation of PET images using an active contour model

Purpose: Although positron emission tomography (PET) images have shown potential to improve the accuracy of targeting in radiation therapy planning and assessment of response to treatment, the boundaries of tumors are not easily distinguishable from surrounding normal tissue owing to the low spatial resolution and inherent noisy characteristics of PET images. The objective of this study is to develop a generic and robust method for automatic delineation of tumor volumes using an active contour model and to evaluate its performance using phantom and clinical studies. Methods: MASAC, a method for automatic segmentation using an active contour model, incorporates the histogram fuzzy C-means clustering, and localized and textural information to constrain the active contour to detect boundaries in an accurate and robust manner. Moreover, the lattice Boltzmann method is used as an alternative approach for solving the level set equation to make it faster and suitable for parallel programming. Twenty simulated phantom studies and 16 clinical studies, including six cases of pharyngolaryngeal squamous cell carcinoma and ten cases of nonsmall cell lung cancer, were included to evaluate its performance. Besides, the proposed method was also compared with the contourlet-based active contour algorithm (CAC) and Schaefer’s thresholding method (ST). The relative volume error (RE), Dice similarity coefficient (DSC), and classification error (CE) metrics were used to analyze the results quantitatively. Results: For the simulated phantom studies (PSs), MASAC and CAC provide similar segmentations of the different lesions, while ST fails to achieve reliable results. For the clinical datasets (2 cases with connected high-uptake regions excluded) (CSs), CAC provides for the lowest mean RE (−8.38% ± 27.49%), while MASAC achieves the best mean DSC (0.71 ± 0.09) and mean CE (53.92% ± 12.65%), respectively. MASAC could reliably quantify different types of lesions assessed in this work with good accuracy, resulting in a mean RE of −13.35% ± 11.87% and −11.15% ± 23.66%, a mean DSC of 0.89 ± 0.05 and 0.71 ± 0.09, and a mean CE of 19.19% ± 7.89% and 53.92% ± 12.65%, for PSs and CSs, respectively. Conclusions: The authors’ results demonstrate that the developed novel PET segmentation algorithm is applicable to various types of lesions in the authors’ study and is capable of producing accurate and consistent target volume delineations, potentially resulting in reduced intraobserver and interobserver variabilities observed when using manual delineation and improved accuracy in treatment planning and outcome evaluation.

60 APPLIED LIFE SCIENCES↗

SU-F-J-38: Dose Rates and Preliminary Evaluation of Contouring Similarity Metrics Using 4D Cone Beam CT

Purpose: 4D imaging modalities require detailed characterization for clinical optimization. The On-Board Imager mounted on the linear accelerator was used to investigate dose rates in a tissue mimicking phantom using 4D-CBCT and assess variability of contouring similarity metrics between 4D-CT and 4D-CBCT retrospective reconstructions. Methods: A 125 kVp thoracic protocol was used. A phantom placed on a motion platform simulated a patient’s breathing cycle. An ion chamber was affixed inside the phantom’s tissue mimicking cavities (i.e. bone, lung, and soft tissue). A sinusoidal motion waveform was executed with a five second period and superior-inferior motion. Dose rates were measured at six ion chamber positions. A preliminary workflow for contouring similarity between 4D-CT and 4D-CBCT was established using a single lung SBRT patient’s historical data. Average intensity projection (Ave-IP) and maximum intensity projection (MIP) reconstructions generated offline were compared between the 4D modalities. Similarity metrics included Dice similarity coefficient (DSC), Hausdorff distance, and center of mass (COM) deviation. Two isolated lesions were evaluated in the patient’s scans: one located in the right lower lobe (ITVRLL) and one located in the left lower lobe (ITVLLL). Results: Dose rates ranged from 2.30 (lung) to 5.18 (bone) E-3 cGy/mAs. For fixed acquisition parameters, cumulative dose is inversely proportional to gantry speed. For ITVRLL, DSC were 0.70 and 0.68, Hausdorff distances were 6.11 and 5.69 mm, and COM deviations were 1.24 and 4.77 mm, for Ave-IP and MIP respectively. For ITVLLL, DSC were 0.64 and 0.75, Hausdorff distances were 10.74 and 8.00 mm, and COM deviations were 7.55 and 4.3 mm, for Ave-IP and MIP respectively. Conclusion: While the dosimetric output of 4D-CBCT is low, characterization is necessary to assure clinical optimization. A basic workflow for comparison of simulation and treatment 4D image-based contours was established. This work was partially supported by a Research Scholar Grant (RSG-15-137-01-CCE) from the American Cancer Society.

60 APPLIED LIFE SCIENCES↗

SU-F-J-88: Comparison of Two Deformable Image Registration Algorithms for CT-To-CT Contour Propagation

Purpose: To compare the contour propagation accuracy of two deformable image registration (DIR) algorithms in the Raystation treatment planning system – the “Hybrid” algorithm based on image intensities and anatomical information; and the “Biomechanical” algorithm based on linear anatomical elasticity and finite element modeling. Methods: Both DIR algorithms were used for CT-to-CT deformation for 20 lung radiation therapy patients that underwent treatment plan revisions. Deformation accuracy was evaluated using landmark tracking to measure the target registration error (TRE) and inverse consistency error (ICE). The deformed contours were also evaluated against physician drawn contours using Dice similarity coefficients (DSC). Contour propagation was qualitatively assessed using a visual quality score assigned by physicians, and a refinement quality score (0 0.9 for lungs, > 0.85 for heart, > 0.8 for liver) and similar qualitative assessments (VQS < 0.35, RQS > 0.75 for lungs). When anatomical structures were used to control the deformation, the DSC improved more significantly for the biomechanical DIR compared to the hybrid DIR, while the VQS and RQS improved only for the controlling structures. However, while the inclusion of controlling structures improved the TRE for the hybrid DIR, it increased the TRE for the biomechanical DIR. Conclusion: The hybrid DIR was found to perform slightly better than the biomechanical DIR based on lower TRE while the DSC, VQS, and RQS studies yielded comparable results for both. The use of controlling structures showed considerable improvement in the hybrid DIR results and is recommended for clinical use in contour propagation.

60 APPLIED LIFE SCIENCES↗

SU-F-J-171: Robust Atlas Based Segmentation of the Prostate and Peripheral Zone Regions On MRI Utilizing Multiple MRI System Vendors

Purpose: Automatically generated prostate MRI contours can be used to aid in image registration with CT or ultrasound and to reduce the burden of contouring for radiation treatment planning. In addition, prostate and zonal contours can assist to automate quantitative imaging features extraction and the analyses of longitudinal MRI studies. These potential gains are limited if the solutions are not compatible across different MRI vendors. The goal of this study is to characterize an atlas based automatic segmentation procedure of the prostate collected on MRI systems from multiple vendors. Methods: The prostate and peripheral zone (PZ) were manually contoured by an expert radiation oncologist on T2-weighted scans acquired on both GE (n=31) and Siemens (n=33) 3T MRI systems. A leave-one-out approach was utilized where the target subject is removed from the atlas before the segmentation algorithm is initiated. The atlas-segmentation method finds the best nine matched atlas subjects and then performs a normalized intensity-based free-form deformable registration of these subjects to the target subject. These nine contours are then merged into a single contour using Simultaneous Truth and Performance Level Estimation (STAPLE). Contour comparisons were made using Dice similarity coefficients (DSC) and Hausdorff distances. Results: Using the T2 FatSat (FS) GE datasets the atlas generated contours resulted in an average DSC of 0.83±0.06 for prostate, 0.57±0.12 for PZ and 0.75±0.09 for CG. Similar results were found when using the Siemens data with a DSC of 0.79±0.14 for prostate, 0.54±0.16 and 0.70±0.9. Contrast between prostate and surrounding anatomy and between the PZ and CG contours for both vendors demonstrated superior contrast separation; significance was found for all comparisons p-value < 0.0001. Conclusion: Atlas-based segmentation yielded promising results for all contours compared to expertly defined contours in both Siemens and GE 3T systems providing fast and automatic segmentation of the prostate. Funding Support, Disclosures, and Conflict of Interest: AS Nelson is a partial owner of MIM Software, Inc. AS Nelson, and A Swallen are current employees at MIM Software, Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-T-253: Volumetric Comparison Between 4D CT Amplitude and Phase Binning Mode

Purpose: Motion artifact in 4DCT images can affect radiation treatment quality. To identify the most robust and accurate binning method, we compare the volume difference between targets delineated on amplitude and phase binned 4DCT scans. Methods: Varian RPM system and CT scanner were used to acquire 4DCTs of a Quasar phantom with embedded cubic and spherical objects having superior-inferior motion. Eight patients’ respiration waveforms were used to drive the phantom. The 4DCT scan was reconstructed into 10 phase and 10 amplitude bins (2 mm slices). A scan of the static phantom was also acquired. For each waveform, sphere and cube volumes were generated automatically on each phase using HU thresholding. Phase (amplitude) ITVs were the union of object volumes over all phase (amplitude) binned images. The sphere and cube volumes measured in the static phantom scan were V{sub sphere}=4.19cc and V{sub cube}=27.0cc. Volume difference (VD) and dice similarity coefficient (DSC) of the ITVs, and mean volume error (MVE) defined as the average target volume percentage difference between each phase image and the static image, were used to evaluate the performance of amplitude and phase binning. Results: Averaged over the eight breathing traces, the VD and DSC of the internal target volume (ITV) between amplitude and phase binning were 3.4%±3.2% (mean ± std) and 95.9%±2.1% for sphere; 2.1%±3.3% and 98.0% ±1.5% for cube, respectively.For all waveforms, the average sphere MVE of amplitude and phase binning was 6.5% ± 5.0% and 8.2%±6.3%, respectively; and the average cube MVE of amplitude and phase binning was 5.7%±3.5%and 12.9%±8.9%, respectively. Conclusion: ITV volume and spatial overlap as assessed by VD and DSC are similar between amplitude and phase binning. Compared to phase binning, amplitude binning results in lower MVE suggesting it is less susceptible to motion artifact.

60 APPLIED LIFE SCIENCES↗

TU-AB-202-02: Deformable Image Registration Accuracy Between External Beam Radiotherapy and HDR Brachytherapy CT Images for Cervical Cancer Using a 3D-Printed Deformable Pelvis Phantom

Purpose: Accurate deformable image registration (DIR) between external beam radiotherapy (EBRT) and HDR brachytherapy (BT) CT images in cervical cancer is challenging. DSC has been evaluated only on the basis of the consistency of the structure, and its use does not guarantee an anatomically reasonable deformation. We evaluate the DIR accuracy for cervical cancer with DSC and anatomical landmarks using a 3D-printed pelvis phantom. Methods: A 3D-printed, deformable female pelvis phantom was created on the basis of the patient’s CT image. Urethane and silicon were used as materials for creating the uterus and bladder, respectively, in the phantom. We performed DIR in two cases: case-A with a full bladder (170 ml) in both the EBRT and BT images and case-B with a full bladder in the BT image and a half bladder (100 ml) in the EBRT image. DIR was evaluated using DSCs and 70 uterus and bladder landmarks. A Hybrid intensity and structure DIR algorithm with two settings (RayStation) was used. Results: In the case-A, DSCs of the intensity-based DIR were 0.93 and 0.85 for the bladder and uterus, respectively, whereas those of hybrid-DIR were 0.98 and 0.96, respectively. The mean landmark error values of intensity-based DIR were 0.73±0.29 and 1.70±0.19 cm for the bladder and uterus, respectively, whereas those of Hybrid-DIR were 0.43±0.33 and 1.23±0.25 cm, respectively. In both cases, the Hybrid-DIR accuracy was better than the intensity-based DIR accuracy for both evaluation methods. However, for several bladder landmarks, the Hybrid-DIR landmark errors were larger than the corresponding intensity-based DIR errors (e.g., 2.26 vs 1.25 cm). Conclusion: Our results demonstrate that Hybrid-DIR can perform with a better accuracy than the intensity-based DIR for both DSC and landmark errors; however, Hybrid-DIR shows a larger landmark error for some landmarks because the technique focuses on both the structure and intensity.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-JeP2-03: Machine-Learning-Based Delineation Framework of GTV Regions of Solid and Ground Glass Opacity Lung Tumors at Datasets of Planning CT and PET/CT Images

Purpose: In radiation treatment planning, delineation of gross tumor volume (GTV) is very important, because the GTVs affect the accuracies of radiation therapy procedure. To assist radiation oncologists in the delineation of GTV regions while treatment planning for lung cancer, we have proposed a machine-learning-based delineation framework of GTV regions of solid and ground glass opacity (GGO) lung tumors following by optimum contour selection (OCS) method. Methods: Our basic idea was to feed voxel-based image features around GTV contours determined by radiation oncologists into a machine learning classifier in the training step, after which the classifier produced the degree of GTV for each voxel in the testing step. Ten data sets of planning CT and PET/CT images were selected for this study. The support vector machine (SVM), which learned voxel-based features which include voxel value and magnitudes of image gradient vector that obtained from each voxel in the planning CT and PET/CT images, extracted initial GTV regions. The final GTV regions were determined using the OCS method that was able to select a global optimum object contour based on multiple active delineations with a level set method around the GTV. To evaluate the results of proposed framework for ten cases (solid:6, GGO:4), we used the three-dimensional Dice similarity coefficient (DSC), which denoted the degree of region similarity between the GTVs delineated by radiation oncologists and the proposed framework. Results: The proposed method achieved an average three-dimensional DSC of 0.81 for ten lung cancer patients, while a standardized uptake value-based method segmented GTV regions with the DSC of 0.43. The average DSCs for solid and GGO were 0.84 and 0.76, respectively, obtained by the proposed framework. Conclusion: The proposed framework with the support vector machine may be useful for assisting radiation oncologists in delineating solid and GGO lung tumors.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-11: Implications for Online Adaptive and Non-Adaptive Radiotherapy of Gastic and Gastroesophageal Junction Cancers Using MRI-Guided Radiotherapy

Purpose: Radiotherapy for gastric and gastroesophageal junction (GEJ) tumors commonly requires large margins due to deformation, motion and variable changes of the stomach anatomy, at the risk of increased normal tissue toxicities. This work quantifies the interfraction variation of stomach deformation from daily MRI-guided radiotherapy to allow for a more targeted determination of margin expansion in the treatment of gastric and GEJ tumors. Methods: Five patients treated for gastric (n=3) and gastroesophageal junction (n=2) cancers with conventionally fractionated radiotherapy underwent daily MR imaging on a clinical MR-IGRT system. Treatment planning and contours were performed based on the MR simulation. The stomach was re-contoured on each daily volumetric setup MR. Dice similarity coefficients (DSC) of the daily stomach were computed to evaluate the stomach interfraction deformation. To evaluate the stomach margin, the maximum Hausdorff distance (HD) between the initial and fractional stomach surface was measured for each fraction. The margin expansion, needed to encompass all fractions, was evaluated from the union of all fractional stomachs. Results: In total, 94 fractions with daily stomach contours were evaluated. For the interfraction stomach differences, the average DSC was 0.67±0.1 for gastric and 0.62±0.1 for GEJ cases. The maximum HD of each fraction was 3.5±2.0cm (n=94) with mean HD of 0.8±0.4cm (across all surface voxels for all fractions). The margin expansion required to encompass all individual fractions (averaged across 5 patients) was 1.4 cm(superior), 2.3 cm(inferior), 2.5 cm(right), 3.2 cm(left), 3.7 cm(anterior), 3.4 cm(posterior). Maximum observed difference for margin expansion was 8.7cm(posterior) among one patient. Conclusion: We observed a notable interfractional change in daily stomach shape (i.e., mean DSC of 0.67, p<0.0001) in both gastric and GEJ patients, for which adaptive radiotherapy is indicated. A minimum PTV margin of 3 cm is indicated to account for interfraction stomach changes when adaptive radiotherapy is not available. M. Bassetti: Travel funding from ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

Ferromagnetic-to-Paramagnetic Phase Transition of MnAs Studied by Calorimetry and Magnetic Measurements

Manganese monoarsenide samples have been prepared by the sealed-ampule technique and characterized by X-ray diffraction, differential thermal analysis, and scanning electron microscopy. The hexagonal- to-orthorhombic phase transition of MnAs has been studied using differential scanning calorimetry (DSC) and magnetic measurements. The enthalpy and temperature range of the transition have been determined to be ΔH =–5.6 J/g and 312.5–319 K, respectively. The enthalpy and temperature range of the transition are influenced by the quality of the samples. The samples containing inclusions of the metastable, orthorhombic phase have a lower enthalpy and broader temperature range of the magnetostructural transformation of manganese monoarsenide. It has been demonstrated that DSC is an effective tool for assessing the quality of MnAs samples. Temperature dependences of specific magnetization and magnetic permeability for MnAs lend support to the DSC results. From these data, the Curie temperature of MnAs has been determined to be 40°C, in good agreement with previously reported data.

36 MATERIALS SCIENCE↗

Power Conversion Efficiencies of Perovskite and Dye-Sensitized Solar Cells under Various Solar Radiation Intensities

We present the results of a comparative study on behaviour of the photovoltaic parameters in perovskite (PSC), dye-sensitized (DSC) and crystalline silicon (c-Si) solar cells under various intensities of solar radiation (10–1000 W/m{sup 2}). It was found that unlike c-Si, the power conversion efficiencies of PSC and DSC under low radiation intensities are comparable with the corresponding values observed under standard light intensity of 1000 W/m{sup 2} (AM1.5G). We have shown that high performance of the PSC and DSC at low and diffuse lighting conditions can be explained by the properties of the nanostructured TiO{sub 2}-based photoelectrodes depending on the structure, morphology and the thickness of the TiO{sub 2} layers.

14 SOLAR ENERGY↗

Constitutive Model Development for Aging Polymer Encapsulants (ASC P&EM FY2021 L2 Milestone 7836)

This SAND report fulfills the completion requirements for the ASC Physics and Engineering Modeling Level 2 Milestone 7836 during Fiscal Year 2021. The Sandia Simplified potential energy clock (SPEC) non-linear viscoelastic constitutive model was developed to predict a whole host of polymer glass physical behaviors in order to provide a tool to assess the effects of stress on these materials over their lifecycle. Polymer glasses are used extensively in applications such as electronics packaging, where encapsulants and adhesives can be critical to device performance. In this work, the focus is on assessing the performance of the model in predicting material evolution associated with long-term physical aging, an area that the model has not been fully vetted in. These predictions are key to utilizing models to help demonstrate electronics packaging component reliability over decades long service lives, a task that is very costly and time consuming to execute experimentally. The initiating hypothesis for the work was that a model calibration process can be defined that enables confidence in physical aging predictions under ND relevant environments and timescales without sacrificing other predictive capabilities. To test the hypothesis, an extensive suite of calibration and aging data was assembled from a combination of prior work and collaborating projects (Aging and Lifetimes as well as the DoD Joint Munitions Program) for two mission relevant epoxy encapsulants, 828DGEBA/DEA and 828DGEBA/T403. Multiple model calibration processes were developed and evaluated against the entire set of data for each material. A qualitative assessment of each calibration's ability to predict the wide range of aging responses was key to ranking the calibrations against each other. During this evaluation, predictions that were identified as non-physical, i.e., demonstrated something that was qualitatively different than known material behavior, were heavily weighted against the calibration performance. Thus, unphysical predictions for one aspect of aging response could generate a lower overall rating for a calibration process even if that process generated better quantitative predictions for another aspect of aging response. This insurance that all predictions are qualitatively correct is important to the overall aim of utilizing the model to predict residual stress evolution, which will depend on the interplay amongst the different material aging responses. The DSC-focused calibration procedure generated the best all-around aging predictions for both materials, demonstrating material models that can qualitatively predict the whole host of different physical aging responses that have been measured. This step forward in predictive capability comes from an unanticipated source, utilization of calorimetry measurements to specify model parameters. The DSC-focused calibration technique performed better than compression-focused techniques that more heavily weigh measurements more closely related to the structural responses to be predicted. Indeed, the DSC-focused calibration procedure was only possible due to recent incorporation of the enthalpy and heat capacity features into SPEC that was newly verified during this L2 milestone. Fundamentally similar aspects of the two material model calibrations as well as parametric studies to assess sensitives of the aging predictions are discussed within the report. A perspective on the next steps to the overall goal of residual stress evolution predictions under stockpile conditions closes the report.

36 MATERIALS SCIENCE↗

Property Measurements of the NaCl-PuCl 3 Molten Salt System

Thermal properties of several compositions of the binary NaCl-PuCl 3 salt were measured to confirm the eutectic composition and provide high quality data for use by MSR developers. The PuCl 3 was generated by reducing PuO 2 to plutonium metal in the presence of calcium metal and then chlorinating the metallic plutonium with NH 4 Cl. The resulting PuCl 3 was used to make seven binary NaCl-PuCl 3 compositions with between 59.9 mol % PuCl 3 (Salt 1) and 20.0 mol % PuCl 3 (Salt 7). The eutectic temperature was measured to be 457 ± 4 °C by onset determination in DSC analyses of the seven mixtures, which is consistent with the values in the literature. Additional transitions were observed at approximately 332 and 363 °C in analyses of the PuCl 3 -rich compositions (Salts 1-3) at about 376 and 439 °C in analyses the Na-rich compositions (Salts 4-7). The solid state heat capacity decreased with increasing PuCl 3 content. The liquid state heat capacity was measured for Salt 3 (37.4 mol % PuCl 3 ) and Salt 4 (38.3 mol % PuCl 3 ). A higher heat capacity was measured for Salt 4 and measurements with both salts showed a positive correlation with temperature between 520 and 730 °C. Cells fabricated from nickel and molybdenum for use in DSC measurements at high temperatures could not be adequately sealed because these materials are not sufficiently malleable, even after high temperature annealing. It is recommended that future development focus on corrosion-resistant materials that have mechanical and thermal properties similar to the commercially available gold cells, such as Pt-Rh (80–20) and pure platinum. Those materials are chemically inert, soft, and malleable like gold, but have melting temperatures higher than 1000 °C (Rakhtsaum, 2013). Use of the Pt-Rh alloy should be evaluated first based on superior machinability for making precision parts and its current use in commercial DSC high temperature crucibles. The commercial Pt-Rh cells are not hermetically sealable, but it is expected that cells made from thinner stock can be sealed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Differential Scanning Calorimetry Calibration and Heat Capacity

The differential scanning calorimeter (DSC) 404 F3 is a machine that heats up to 1500 degrees Celsius, and collects/evaluates thermal properties such as heat capacity, crystallization, glass transition, and more. The first part of the project is based around calibrating the DSC 404 F3 using the given procedures and manuals. This ensures that the DSC 404 F3 is working properly and does not have any issues moving forward. After the calibration is complete, the second part is to start testing. There will be tests conducted on known metals, such as steel and aluminum, in which there is data to compare it to. If the data collected is not accurate compared to its known values, further troubleshooting will need to ensue to ensure that the following process does not give wrong readings. Then, testing will begin for High Entropy Alloys(HEA) and the interesting issue with these is that there is no data to compare these to. The goal of finding the values of the HEA is to find a compatible alloy that we can use in future projects.

Szczech, Sebastian↗

Modeling Approach for the Aluminum-clad Dry Storage Pilot using HFIR Fuel

To confirm that the dry storage of aluminum-clad research reactor spent nuclear fuel (ASNF) will remain within the safety envelope after applied drying schemes and that the resulting evolution of the gas space composition, temperature, and pressure conditions are understood, a dry storage pilot project is being established. The pilot will incorporate an instrumented lid for discrete interval or for on-demand gas composition and temperature monitoring of two DOE Standard Canisters (DSCs) loaded with three High Flux Isotope Reactor (HFIR) inner cores per DSC. Each DSC would be subjected to a separate alternative candidate drying scheme. Canisters will undergo 1 to 5 years of monitoring, including internal temperature and gas sampling to track pressure and composition changes. This report outlines the approach for modeling the ASNF-in-canister behavior in terms of evolving gas space conditions for the ASNF dry storage pilot using HFIR fuel. The ASNF has an adherent surface oxyhydroxide layer comprised of boehmite/bayerite that generates hydrogen when subjected to irradiation. Three-dimensional multi-physics computational fluid dynamics simulations will be executed to compute the thermal field within the DSC and provide inputs to a chemical model employed to compute pressure buildup as hydrogen is generated in the system. Implemented in Cantera, the chemical model solves gas phase and aluminum oxyhydroxide surface-mediated radiolysis reactions. Gas phase reactions are sourced from Wittman and Hanson (2015), whereas surface-mediated reactions are incorporated by fitting experimental data using an optimization algorithm (Abboud, 2023). Water radiolysis reactions from Wren and Ball (2001) are adopted with modifications as described in Abboud (2023c). Understanding the effect of the hydrogen buildup over time is important for long-term storage safety considerations. Modeling results will include the canister pressure, temperature, and composition evolution from the initial helium backfill with the addition of radiolytically-evolved chemical species (e.g., hydrogen and oxygen). The specific HFIR cores for the pilot program have not yet been selected, and the overall design is still in development. The CFD-chemical model used for this work will be based on prior models with necessary updates to allow for improved accuracy and efficiency. The experimental data obtained from the HFIR demonstration will be used to improve and validate the computational models to predict the ASNF-in-canister behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interpreting T-History Data on Supercooling and Phase Change Enthalpy of a Salt-Hydrogel Complex for Building Thermal Management

Phase change materials (PCMs) are promising materials for storing and discharging latent heat in buildings to regulate the thermal environment. Measurement of salt hydrate PCM thermal performance is often challenging because of supercooling and phase segregation. Though differential scanning calorimetry (DSC) has been widely used to measure thermal properties of various phase change materials, DSC uses milligrams of sample and is unrealistic for predicting large-scale materials performance. The T-history method [1], in contrast, handles higher volumes but the analysis typically requires a lumped capacitance assumption. Here, we report and analyze T-History data on a novel salt-hydrogel complex with high viscosity, that renders low Biot number sample preparation extremely challenging. We re-examine the standard T-history method and compared against DSC data in this complex material. We report details of an experimental setup, built with necessary additions to a controlled environmental chamber. We carefully examine the validity of the lumped capacitance assumption and suggest a modified analysis using a computational approach for reliable data. Experimental parameters such as ramp rate and temperature range of the environmental chamber are considered via computational modeling to understand the effect of ramp rate on supercooling [2]. Finally, we report thermal cycling experiments on the salt-hydrogel complex. Our modified approach to measuring supercooling and enthalpy of fusion at large scales is important in better understanding the performance of phase-change materials at scale for building thermal storage. References: [1] Marin, Jose M, Belen Zalba, Luisa F Cabeza, and Harald Mehling. “Determination of Enthalpy Temperature Curves of Phase Change Materials with the Temperature-History Method: Improvement to Temperature Dependent Properties.” Measurement Science and Technology 14, no. 2 (February 1, 2003): 184–89. https://doi.org/10.1088/0957-0233/14/2/305. [2] Safari, A., R. Saidur, F.A. Sulaiman, Yan Xu, and Joe Dong. “A Review on Supercooling of Phase Change Materials in Thermal Energy Storage Systems.” Renewable and Sustainable Energy Reviews 70 (April 2017): 905–19. https://doi.org/10.1016/j.rser.2016.11.272

thermodynamics↗

Impact of Cooling Rate and Thermal Mass on Supercooling in a Salt-Hydrogel Complex for Thermal Energy Storage

Glauber’s salt is a promising phase change material for building thermal management because of its high latent heat, acceptable melting temperature of 32.3 °C for indoor air1,2. Despite these advantages, the practical application of Glauber’s salt in thermal energy storage systems is still challenging due to supercooling and phase segregation1–3. Here, we report the impact of temperature ramp rate and thermal mass on the supercooling of Glauber’s salt through the DSC and T-history experiment. The ramp rate effect was studied with a wide range of ramp rates in 1 to 10 °C/min in DSC and 1 to 4 °C/min in the T-history experiment. The thermal mass effect was investigated by comparing DSC and T-history experiment. The latent heat was also analyzed for different ramp rates and thermal mass conditions. The melting temperatures of Glauber’s salt from the two techniques were identical while freezing temperatures were different because of the thermal mass effect. During freezing in the T-history experiment, the latent heat was reduced by around 75% to the latent heat in melting due to supercooling and phase segregation. To overcome this bottleneck, we developed a novel hydrogel complex that reduces the supercooling and prevents phase segregation to maintain volumetric energy density for 100 cycles. Thermodynamic analysis accounting for composition shows that a higher salt composition can further enhance the volumetric energy storage density. For example, a 10% increase in the weight percentage of salt leads to about 50% enhancement in volumetric energy storage density. References: 1. D. R. Biswas, Solar Energy. 19, 99–100 (1977). 2. S. M. Hasnain, Energy Conversion and Management. 39, 1127–1138 (1998). 3. Byung Chul Shin, Sang Done Kim, P. Won-Hoon, Energy. 14, 921–930 (1989).

inorganic, thermodynamics↗