Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Plotting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Medical and Scientific Evaluations aboard the KC-135. Microgravity-Compatible Flow Cytometer

A spaceflight-compatible flow cytometer would be useful for the diagnosis of astronaut illness during long duration spaceflight and for conducting in-flight research to evaluate the effects of microgravity on human physiology. Until recently, the primary limitations preventing the development of a spaceflight compatible flow cytometer have been largely mechanical. Standard commercially available flow cytometers are large, complex instruments that use high-energy lasers and require significant training to operate. Standard flow cytometers function by suspending the particles to be analyzed inside a sheath fluid for analysis. This requires the presence of several liters of sheath fluid for operation, and generates a corresponding amount of liquid hazardous waste. The particles are then passed through a flow cell which uses the fluid mechanical property of hydrodynamic focusing to place the cells in single-file (laminar flow) as they pass through a laser beam for scanning and evaluation. Many spaceflight experiments have demonstrated that fluid physics is dramatically altered in microgravity (MSF [Manned Space Flight] Fluid Physics Data Sheet-August 1997) and previous studies have shown that sheath-fluid based hydrodynamic focusing may also be altered during microgravity (Crucian et al, 2000). For these reasons it is likely that any spaceflight compatible design for a flow cytometer would abandon the sheath fluid requirement. The elimination of sheath fluid would remove both the problems of weight associated with large volumes of liquids as well as the large volume of liquid waste generated. It would also create the need for a method to create laminar particle flow distinct from the standard sheath-fluid based method. The spaceflight prototype instrument is based on a recently developed commercial flow cytometer possessing a novel flow cell design that creates single-particle laser scanning and evaluation without the need for sheath-fluid based hydrodynamic focusing. This instrument also possesses a number of design advances that make it conditionally microgravity compatible: it is highly miniaturized and lightweight, uses a low energy diode laser, has a small number of moving parts, does not use sheath fluid and does not generate significant liquid waste. Although possessing certain limitations, the commercial cytometer functions operationally like a standard bench top laboratory flow cytometer, aspirating liquid particle samples and generating histogram or dot-plot data in standard FCS file format. In its current configuration however, the cytometer is limited to three parameter/two-color capability (two color PMTs + forward scatter), does not allow compensation between colors, does not allow linear analysis and is operated by rather inflexible software with limited capabilities. This is due to the fact that the cytometer has been designed and marketed as an instrument specific to a few particular assays, not as a multipurpose cytometer.

Crucian, Brian↗

Variation in stem mortality rates determines patterns of above-ground biomass in Amazonian forests: implications for dynamic global vegetation models

Understanding the processes that determine above-ground biomass (AGB) in Amazonian forests is important for predicting the sensitivity of these ecosystems to environmental change and for designing and evaluating dynamic global vegetation models (DGVMs). AGB is determined by inputs from woody productivity [woody net primary productivity (NPP)] and the rate at which carbon is lost through tree mortality. Here, we test whether two direct metrics of tree mortality (the absolute rate of woody biomass loss and the rate of stem mortality) and/or woody NPP, control variation in AGB among 167 plots in intact forest across Amazonia. We then compare these relationships and the observed variation in AGB and woody NPP with the predictions of four DGVMs. The observations show that stem mortality rates, rather than absolute rates of woody biomass loss, are the most important predictor of AGB, which is consistent with the importance of stand size structure for determining spatial variation in AGB. The relationship between stem mortality rates and AGB varies among different regions of Amazonia, indicating that variation in wood density and height/diameter relationships also influences AGB. In contrast to previous findings, we find that woody NPP is not correlated with stem mortality rates and is weakly positively correlated with AGB. Across the four models, basin-wide average AGB is similar to the mean of the observations. However, the models consistently overestimate woody NPP and poorly represent the spatial patterns of both AGB and woody NPP estimated using plot data. In marked contrast to the observations, DGVMs typically show strong positive relationships between woody NPP and AGB. Resolving these differences will require incorporating forest size structure, mechanistic models of stem mortality and variation in functional composition in DGVMs.

54 ENVIRONMENTAL SCIENCES↗

Effect of Rice Husk Derived Nanosilica on the Structure, Properties and Biodegradability of Corn-Starch/LDPE Composites

Development of material with enhanced mechanical properties and biodegradability by the incorporation of synthesized inorganic nanostructured mesoporous silica from rice husk has been investigated. The produced nanosilica (≈ 25 nm and 213.045 m{sup 2}/g surface area) and nanosilica blended LDPE/starch composites were extensively characterised by SEM, FTIR, XRD, XRF, TEM, EDAX and TGA analysis. The low cost of production estimated, ensures its feasibility toward large scale application. The addition of nanosilica into the matrix led to the enhancement of Young’s modulus and stiffness by a value of 535.6 MPa and 32172.81 N/m respectively at 3% nanosilica content, thereby enhancing the initial rigidity and resistivity towards deformation making a better biodegradable substitute in terms of initial application range. The MFI and hardness value also increased with increase of silica content upto 1.5% and 2% respectively to 7.23 g/10 min and 42 (Shor D). Increase in nanofiller content improved the value of degradation rate constant (k) of the weight loss data plot in both vegetable waste and garden soil environment. The addition of 1.5% of nanosilica to a blend of 80% LDPE and 20% starch showed almost the same biodegradation rate as that without nanosilica but with superior mechanical properties and applicability range.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Comparison of high-pressure CO 2 sorption isotherms on Eastern and Western US coals

Accurate estimation of carbon dioxide (CO 2 ) sorption capacity of coal is important for planning the CO 2 sequestration efforts. In this work, we investigated sorption and swelling behavior of several Eastern and Western US coal samples from the Central Appalachian Basin and from San Juan Basin. The CO 2 sorption isotherms have been completed at 55°C for as received and dried samples. The role of mineral components in coal, the coal swelling, the effects of temperature and moisture, and the error propagation have been analyzed. Changes in void volume due to dewatering and other factors such as temporary caging of carbon dioxide molecules in coal matrix were identified among the main factors affecting accuracy of the carbon dioxide sorption isotherms. The (helium) void volume in the sample cells was measured before and after the sorption isotherm experiments and was used to build the volume-corrected data plots.

01 COAL, LIGNITE, AND PEAT↗

SU-F-R-11: Designing Quality and Safety Informatics Through Implementation of a CT Radiation Dose Monitoring Program

Purpose: Recent legislative and accreditation requirements have driven rapid development and implementation of CT radiation dose monitoring solutions. Institutions must determine how to improve quality, safety, and consistency of their clinical performance. The purpose of this work was to design a strategy and meaningful characterization of results from an in-house, clinically-deployed dose monitoring solution. Methods: A dose monitoring platform was designed by our imaging physics group that focused on extracting protocol parameters, dose metrics, and patient demographics and size. Compared to most commercial solutions, which focus on individual exam alerts and global thresholds, the program sought to characterize overall consistency and targeted thresholds based on eight analytic interrogations. Those were based on explicit questions related to protocol application, national benchmarks, protocol and size-specific dose targets, operational consistency, outliers, temporal trends, intra-system variability, and consistent use of electronic protocols. Using historical data since the start of 2013, 95% and 99% intervals were used to establish yellow and amber parameterized dose alert thresholds, respectively, as a function of protocol, scanner, and size. Results: Quarterly reports have been generated for three hospitals for 3 quarters of 2015 totaling 27880, 28502, 30631 exams, respectively. Four adult and two pediatric protocols were higher than external institutional benchmarks. Four protocol dose levels were being inconsistently applied as a function of patient size. For the three hospitals, the minimum and maximum amber outlier percentages were [1.53%,2.28%], [0.76%,1.8%], [0.94%,1.17%], respectively. Compared with the electronic protocols, 10 protocols were found to be used with some inconsistency. Conclusion: Dose monitoring can satisfy requirements with global alert thresholds and patient dose records, but the real value is in optimizing patient-specific protocols, balancing image quality trade-offs that dose-reduction strategies promise, and improving the performance and consistency of a clinical operation. Data plots that capture patient demographics and scanner performance demonstrate that value.

60 APPLIED LIFE SCIENCES↗

TU-FG-201-07: Development of SRS Conical Collimator Collision Prediction Software for Radiation Treatment Safety

Purpose: Stereotactic radiosurgery (SRS) treatments using conical collimators can potentially result in gantry collision with treatment table due to limited collision-clear spaces. An in-house software was developed to help the SRS treatment planner mitigate potential SRS conical collimator (Varian Medical System, Palo Alto, CA) collisions with the treatment table. This software was designed to remove treatment re-planning secondary to unexpected collisions. Methods: A BrainLAB SRS ICT Frameless Extension used for SRS treatments in our clinic was mathematically modelled using surface points registered to the 3D co-ordinate space of the couch extension. The surface points are transformed based on the treatment isocenter point and potential collisions are determined in 3D space for couch and gantry angle combinations. The distance between the SRS conical collimators and LINAC isocenter is known. The collision detection model was programmed in MATLAB (Mathwork, Natick, MA) to display graphical plots of the calculations, and the plotted data is used to avoid the gantry and couch angle combinations that would likely result in a collision. We have utilized the cone collision tool for 23 SRS cone treatment plans (8 retrospective and 15 prospective for 10 patients). Results: Twenty one plans strongly agreed with the software tool prediction for collision. However, in two plans, a collision was observed with a 0.5 cm margin when the software predicted no collision. Therefore, additional margins were added to the clearance criteria in the program to achieve a lower risk of actual collisions. Conclusion: Our in-house developed collision check software successfully avoided SRS cone re-planning by 91.3% due to a reduction in cone collisions with the treatment table. Future developments to our software will include a CT image data set based collision prediction model as well as a beam angle optimization tool to avoid normal critical tissues as well as previously treated lesions.

60 APPLIED LIFE SCIENCES↗

coloring v.1.0

SAND2024-02435O The software coloring allows applications written in the C++ language to generate publication-quality 2D plots. Its functionality is similar to Microsoft Excel's chart functionality or the Python language's matplotlib package. The value of coloring is that it is written purely in C++ and thus can be compiled on systems where Python is not available and linked into high performance computing software. For drawing shapes onto an image, coloring uses the mathematical definition of quadratic Bezier splines and uses Newton's method to search for the closest point on a spline to a given query point. This is then used to do accurate sub-pixel sampling to get clean, non-pixelated images. For working with the actual plot data, coloring has basic statistical methods such as finding maxima and minima as well as axis scaling such as logarithms. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Ibanez, Daniel↗

The Effect of the CO32- to Ca2+ Ion activity ratio on calcite precipitation kinetics and Sr2+ partitioning

Engineering the precipitation of calcium carbonate, which can co-precipitate trace metal contaminants, is a proposed strategy for remediating toxic or radioactive metals in subsurface environments. Engineering precipitation of multi-component minerals will involve injection of chemical amendments that must be mixed at a molecular level to supersaturated conditions that are sufficient to promote rapid mineral precipitation relative to natural systems. In subsurface systems this often means reactant mixing zones will be formed that are characterized by gradients in solute concentrations, saturation state, and solute activity ratios. To better understand the effect of ion activity ratios on CaCO{sub 3} precipitation kinetics and Sr{sup 2+} co-precipitation we experiments were conducted under constant composition conditions where the supersaturation state ({Omega}) with respect to calcite was held constant at 9.4, but the ion activity ratio (r = a{sub co{sub 3}{sup 2-}}/a{sub Ca{sup 2+}}) ranged from 0.003 to 4.15. Results: Under the chosen experimental conditions the CaCO{sub 3} phase formed was calcite and initial precipitation rates varied from a maximum rate of 84.7 {mu}mol/ m{sup 2}/min for a carbonate to calcium activity ratio of (0.21). However, precipitation rates were found to vary with time which could be indicative of variations in precipitation mechanisms that are related to the ion activity ratio. The observed trends in the distribution coefficients for co-precipitated Sr2+ (D{sup P}{sub Sr}{sup 2+}) relative to the calcite precipitation rate (i.e. a positive correlation) indicate that increasing calcite precipitation rates increase the incorporation of Sr{sup 2+}. Conclusion: The observed variation between the rate maxima and minima based on the ion activity ratio could have great deal of implication for sequestering radionuclides (e.g. {sup 90}Sr) and other toxic metals in engineered systems at contaminated sites. Extending our data plot range allowed us to have clues about the differences in mechanism calcite precipitation, which would have significance in our understanding of mineral precipitation modes in subsurface remediation strategies. The positive correlation between D{sup P}{sub Sr}{sup 2+} and calcite precipitation rate could be indicative of the impact calcite precipitation would have on sequestering toxic metals in subsurface environment.

54 ENVIRONMENTAL SCIENCES↗

TEAMER: Performance mapping of Re Vision's Persistance PTO

Contains datasets from experimental measurements that were used to validate Re Vision's Persistence PTO's efficiency and performance. These measurements were obtained using a dynamometer test bench setup. The data includes open-circuit voltage and loss measurements to validate machine characteristics, efficiency mapping tests to determine the generator's performance mapping, and efficiency mapping tests to determine the converter's efficiency over the feasible operating range. This data was collected between June 2023 and September 2023. The data was collected at the National Renewable Energy Laboratory's Flatirons Campus, Colorado, United States. The data was collected using NREL's 5-kW dynamometer test bench, equipped with a torque sensor and various voltage and current sensors fed to a dedicated data acquisition system. Units for the data are included in the data file headers for each data series. A text editor or spreadsheet software such as Excel is required to view the *.csv data. The data are also provided in *.mat files. To view data plots, a Matlab script with *.mat files are provided.

16 TIDAL AND WAVE POWER↗

Acoustic Doppler Current Profiler Surveys of Velocity Downstream of Albeni Falls Dam

The U.S. Army Corps of Engineers (USACE), Seattle District, is studying the potential to locate fish bypass systems at Albeni Falls Dam. The USACE requested Pacific Northwest National Laboratory (PNNL) to survey velocity magnitude and direction in the dam tailrace. The empirical data collected will be used to support future numerical modeling, physical modeling, and evaluation of fish bypass system alternatives. In May 2010, PNNL conducted velocity surveys of the Albeni Falls Dam using a boat-mounted acoustic Doppler current profiler. The surveys were conducted over three days (May 25 through 27). During the survey period, total river discharge at the dam varied between 30.2 and 31.0 kcfs. A small amount of spill discharge, 2 kcfs, was present on two days (May 26 and 27). This report presents data plots showing measured velocity direction and magnitude averaged over the entire depth and over 5-ft depth increments from 5 to 30 ft.

13 HYDRO ENERGY↗

Creating a Vibration Data Visualization and Analysis Graphical User Interface in Matlab [Poster]

Vibration testing in W-14 results in large amounts of data that need to be preprocessed before being used in reports or for model verification. It can take a large amount of time to accomplish simple, repetitive tasks on many channels of data. A Graphical User Interface (GUI) streamlines visualization and simple processing of the data to make the process faster as well as more intuitive. Simple editing methods, such as data segmentation and axis conversion, put the data in a form that can be easily moved into a more advanced modal analysis or data plotting package.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Failure Diameter of PBX 9502: Simulations with the SURFplus model

SURFplus is a reactive burn model for high explosives aimed at modelling shock initiation and propagation of detonation waves. It utilizes the SURF model for the fast hot-spot reaction plus a slow reaction for the energy released by carbon clustering. A feature of the SURF model is that there is a partially decoupling between burn rate parameters and detonation wave properties. Previously, parameters for PBX 9502 that control shock ini- tiation had been calibrated to Pop plot data (distance-of-run to detonation as a function of shock pressure initiating the detonation). Here burn rate parameters for the high pres- sure regime are adjusted to t the failure diameter and the limiting detonation speed just above the failure diameter. Simulated results are shown for an uncon ned rate stick when the 9502 diameter is slightly above and slightly below the failure diameter. Just above the failure diameter, in the rest frame of the detonation wave, the front is sonic at the PBX/air interface. As a consequence, the lead shock in the neighborhood of the interface is supported by the detonation pressure in the interior of the explosive rather than the reaction immediately behind the front. In the interior, the sonic point occurs near the end of the fast hot-spot reaction. Consequently, the slow carbon clustering reaction can not a ect the failure diameter. Below the failure diameter, the radial extent of the detonation front decreases starting from the PBX/air interface. That is, the failure starts at the PBX boundary and propagates inward to the axis of the rate stick.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Comparison Between Surf and Multi-Shock Forest Fire High Explosive Burn Models

PAGOSA1 has several different burn models used to model high explosive detonation. Two of these, Multi-Shock Forest Fire and Surf, are capable of modeling shock initiation. Accurately calculating shock initiation of a high explosive is important because it is a mechanism for detonation in many accident scenarios (i.e. fragment impact). Comparing the models to pop-plot data give confidence that the models are accurately calculating detonation or lack thereof. To compare the performance of these models, pop-plots2 were created from simulations where one two cm block of PBX 9502 collides with another block of PBX 9502.

54 ENVIRONMENTAL SCIENCES↗

SURFplus Model Calibration for PBX 9502

The SURFplus reactive burn model is calibrated for the TATB based explosive PBX 9502 at three initial temperatures; hot (75 C), ambient (23 C) and cold (-55 C). The CJ state depends on the initial temperature due to the variation in the initial density and initial specific energy of the PBX reactants. For the reactants, a porosity model for full density TATB is used. This allows the initial PBX density to be set to its measured value even though the coeffcient of thermal expansion for the TATB and the PBX differ. The PBX products EOS is taken as independent of the initial PBX state. The initial temperature also affects the sensitivity to shock initiation. The model rate parameters are calibrated to Pop plot data, the failure diameter, the limiting detonation speed just above the failure diameters, and curvature effect data for small curvature.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Failure Diameter Resolution Study

Previously the SURFplus reactive burn model was calibrated for the TATB based explosive PBX 9502. The calibration was based on fitting Pop plot data, the failure diameter and the limiting detonation speed, and curvature effect data for small curvature. The model failure diameter is determined utilizing 2-D simulations of an unconfined rate stick to find the minimum diameter for which a detonation wave propagates. Here we examine the effect of mesh resolution on an unconfined rate stick with a diameter (10mm) slightly greater than the measured failure diameter (8 to 9 mm).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

xRage simulations of magnetic velocity gauges used in gas gun shock initiation experiments

Shock initiation gas gun experiments of PBX 9012 have been performed by Burns and Chiquete [2020] using magnetic velocity gauges as the principal diagnostic. In private communications, the experimenters noted that compatibility issues required a different glue to bond the gauges to PBX 9012 then previously used for experiments with PBX 9501 and PBX 9502. The silicon glue used is more viscous and can result in glue layers up to 50 microns, which is about the gauge thickness. This raises the question on what affect the thicker glue layers have on the gauge response. In particular, the width of the lead shock can affect the accuracy of inferring shock locus points used for the shock pressure of Pop plot data points and for Hugoniot data to calibrate the reactants EOS.

36 MATERIALS SCIENCE↗