Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data reduction methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Application of Machine Learning Techniques in Calibration and Data Reduction of Multi-Hole Probes

This work presents procedures to implement machine learning methods in the existing algorithms for multi-hole probe calibrations and data reduction. It is shown here, that utilizing artificial neural networks (ANNs) can reduce the amount of calibration data that needs to be acquired in order to obtain a specific calibration uncertainty, by more than 50% while simultaneously reducing data reduction times significantly. ANNs were used instead of the surface fitting methods, where first, the directional calibration coefficients related to the flow angles are calculated based on the pressure measurements, and then the flow angles are used as a set of the input parameters for the following ANNs to define Mach number and static and total pressure iteratively. In a second approach, novel calibration coefficients were used to directly relate the pressure measurements from five-hole probe to the quantities of interest thus, eliminating the need for iterative algorithms used in the conventional surface fitting methods. The advantageous features of this method are an average increase of less than 1% in the calibration uncertainty for flow angles and significant reduction of the data reduction times (few seconds). In addition, we confirmed the methodology to avoid over-fitting and under-fitting.

Machine Learning↗

Lightning Charge Retrievals: Dimensional Reduction, LDAR Constraints, and a First Comparison w/ LIS Satellite Data

A "dimensional reduction" (DR) method is introduced for analyzing lightning field changes whereby the number of unknowns in a discrete two-charge model is reduced from the standard eight to just four. The four unknowns are found by performing a numerical minimization of a chi-squared goodness-of-fit function. At each step of the minimization, an Overdetermined Fixed Matrix (OFM) method is used to immediately retrieve the best "residual source". In this way, all 8 parameters are found, yet a numerical search of only 4 parameters is required. The inversion method is applied to the understanding of lightning charge retrievals. The accuracy of the DR method has been assessed by comparing retrievals with data provided by the Lightning Detection And Ranging (LDAR) instrument. Because lightning effectively deposits charge within thundercloud charge centers and because LDAR traces the geometrical development of the lightning channel with high precision, the LDAR data provides an ideal constraint for finding the best model charge solutions. In particular, LDAR data can be used to help determine both the horizontal and vertical positions of the model charges, thereby eliminating dipole ambiguities. The results of the LDAR-constrained charge retrieval method have been compared to the locations of optical pulses/flash locations detected by the Lightning Imaging Sensor (LIS).

Koshak, William↗

Lightning Charge Retrievals: Dimensional Reduction, LDAR Constraints, and a First Comparison with LIS Satellite Data

A "dimensional reduction" (DR) method is introduced for analyzing lightning field changes (DELTAEs) whereby the number of unknowns in a discrete two-charge model is reduced from the standard eight (x, y, z, Q, x', y', z', Q') to just four (x, y, z, Q). The four unknowns (x, y, z, Q) are found by performing a numerical minimization of a chi-square function. At each step of the minimization, an Overdetermined Fixed Matrix (OFM) method is used to immediately retrieve the best "residual source" (x', y', z', Q'), given the values of (x, y, z, Q). In this way, all 8 parameters (x, y, z, Q, x', y', z', Q') are found, yet a numerical search of only 4 parameters (x, y, z, Q) is required. The DR method has been used to analyze lightning-caused DeltaEs derived from multiple ground-based electric field measurements at the NASA Kennedy Space Center (KSC) and USAF Eastern Range (ER). The accuracy of the DR method has been assessed by comparing retrievals with data provided by the Lightning Detection And Ranging (LDAR) system at the KSC-ER, and from least squares error estimation theory, and the method is shown to be a useful "stand-alone" charge retrieval tool. Since more than one charge distribution describes a finite set of DELTAEs (i.e., solutions are non-unique), and since there can exist appreciable differences in the physical characteristics of these solutions, not all DR solutions are physically acceptable. Hence, an alternative and more accurate method of analysis is introduced that uses LDAR data to constrain the geometry of the charge solutions, thereby removing physically unacceptable retrievals. The charge solutions derived from this method are shown to compare well with independent satellite- and ground-based observations of lightning in several Florida storms.

Koshak, W. J.↗

Lightning Charge Retrievals: Dimensional Reduction, LDAR Constraints, and a First Comparison with LIS Satellite Data

A "dimensional reduction" ("DR") method is introduced for analyzing lightning field changes ((Delta)Es) whereby the number of unknowns in a discrete two-charge model is reduced from the standard eight (x, y, z, Q, x', y', z', Q') to just four (x, y, z, Q). The four unknowns (x, y, z, Q) are found by performing a numerical minimization of a chi-square function. At each step of the minimization, an overdetermined fixed matrix (OFM) method is used to immediately retrieve the best "residual source" (x', y', z', Q'), given the values of (x, y, z, Q). In this way, all eight parameters Ix. y, z, Q, x', y', z', Q') are found, yet a numerical search of only four parameters (x, y, z, Q) is required. The DR method has been used to analyze lightning-caused (Delta)Es derived from multiple ground-based electric field measurements at the NASA Kennedy Space Center (KSC) and U.S. Air Force Eastern Range (ER). The accuracy of the DR method has been assessed by comparing retrievals with data provided by the lightning detection and ranging (LDAR) system at the KSC-ER. and from least squares error estimation theory, and the method is shown to be a useful "stand alone" charge retrieval tool. Since more than one charge distribution describes a finite set of (Delta)Es (i.e., solutions are nonunique), and since there can be appreciable differences in the physical characteristics of these solutions, not all DR solutions are physically acceptable. Hence. an alternative and more accurate method of analysis is introduced that uses LDAR data to constrain the geometry of the charge solutions. thereby removing physically unacceptable retrievals. The charge solutions derived from this method are shown to compare well with independent satellite- and ground-based observations of lightning m several Florida storms.

Koshak, W. J.↗

Unsteady Aerodynamic Testing Using the Dynamic Plunge Pitch and Roll Model Mount

A final report on the DyPPiR tests that were run are presented. Essentially it consists of two parts, a description of the data reduction techniques and the results. The data reduction techniques include three methods that were considered: 1) signal processing of wind on - wind off data; 2) using wind on data in conjunction with accelerometer measurements; and 3) using a dynamic model of the sting to predict the sting oscillations and determining the aerodynamic inputs using an optimization process. After trying all three, we ended up using method 1, mainly because of its simplicity and our confidence in its accuracy. The results section consists of time history plots of the input variables (angle of attack, roll angle, and/or plunge position) and the corresponding time histories of the output variables, C(sub L), C(sub D), C(sub m), C(sub l), C(sub m), C(sub n). Also included are some phase plots of one or more of the output variable vs. an input variable. Typically of interest are pitch moment coefficient vs. angle of attack for an oscillatory motion where the hysteresis loops can be observed. These plots are useful to determine the "more interesting" cases. Samples of the data as it appears on the disk are presented at the end of the report. The last maneuver, a rolling pull up, is indicative of the unique capabilities of the DyPPiR, allowing combinations of motions to be exercised at the same time.

Lutze, Frederick H.↗

Data volume reduction for imaging radar polarimetry

Two alternative methods are presented for digital reduction of synthetic aperture multipolarized radar data using scattering matrices, or using Stokes matrices, of four consecutive along-track pixels to produce averaged data for generating a synthetic polarization image.

Zebker, Howard A.↗

Data volume reduction for imaging radar polarimetry

Two alternative methods are disclosed for digital reduction of synthetic aperture multipolarized radar data using scattering matrices, or using Stokes matrices, of four consecutive along-track pixels to produce averaged data for generating a synthetic polarization image.

Zebker, Howard A.↗

The design of a turboshaft speed governor using modern control techniques

The objectives of this program were: to verify the model of off schedule compressor variable geometry in the T700 turboshaft engine nonlinear model; to evaluate the use of the pseudo-random binary noise (PRBN) technique for obtaining engine frequency response data; and to design a high performance power turbine speed governor using modern control methods. Reduction of T700 engine test data generated at NASA-Lewis indicated that the off schedule variable geometry effects were accurate as modeled. Analysis also showed that the PRBN technique combined with the maximum likelihood model identification method produced a Bode frequency response that was as accurate as the response obtained from standard sinewave testing methods. The frequency response verified the accuracy of linear models consisting of engine partial derivatives and used for design. A power turbine governor was designed using the Linear Quadratic Regulator (LQR) method of full state feedback control. A Kalman filter observer was used to estimate helicopter main rotor blade velocity. Compared to the baseline T700 power turbine speed governor, the LQR governor reduced droop up to 25 percent for a 490 shaft horsepower transient in 0.1 sec simulating a wind gust, and up to 85 percent for a 700 shaft horsepower transient in 0.5 sec simulating a large collective pitch angle transient.

Delosreyes, G.↗

Investigation of Boundary Layer Development in Multi-Stage Low Pressure

A review of recent literature has been made in the areas of unsteady measurement in turbomachinery and LP turbine design. This has included a detailed review of methods for extracting quantitative shear stress data from surface mounted hot-film arrays. Research goals were identified on the basis of the literature survey and following interaction with the GE and NASA contracts. Progress has also been made in the detailed planning of the research program. An array of hot-film sensors has been mounted at mid-span on a second stage nozzle blade ready for installation in the current turbine buildup. A new technique of applying the hot-film array using double sided adhesive is being tested. The temperature in the vicinity of the hot-films will be monitored using a thermocouple attached to the blade pressure surface. This will increase the accuracy of the data reduction process compared with the methods applied by Halstead et at. (1995) and others. Data obtained from this first set of sensors, along with data from the hot-wire investigation will help to determine the best locations for surface hot-film instrumentation for subsequent builds of the turbine. Other LSRT instrumentation issues which have been addressed include calibration of the torque measurement system and procurement of custom design hot-wire sensors required to compensate for the slope flow path. Preliminary attempts at modeling the boundary layer transition process have been completed. A steady, coupled viscous-inviscid flow solver (the MISES code of Drela and Youngren) was used to calculate the steady-flow boundary layer transition location.

Source record↗

Precise time and time interval data handling and reduction

In the past year, the increase in Precise Time And Time Interval data to be reduced to the U.S. Naval Observatory Master Clock and the requirement for its quick dissemination has necessitated development of more efficient methods of data handling and reduction. An outline of the data involved and of the Time Service computerization of these functions is presented.

Fisher, L. C.↗

Maximum RMS error comparison of several redundancy techniques

Paper presents mathematical comparison of several techniques with the limiting slope technique for data reduction and reconstruction. Limiting slope method results in maximum possible RMS error versus data compression ratio advantage of 2-to-1 over step and fan methods and 3-to-1 over the two point projection method.

Breaux, J. N.↗

Calibration of the COBE FIRAS instrument

The Far-Infrared Absolute Spectrophotometer (FIRAS) instrument on the Cosmic Background Explorer (COBE) satellite was designed to accurately measure the spectrum of the cosmic microwave background radiation (CMBR) in the frequency range 1-95/cm with an angular resolution of 7 deg. We describe the calibration of this instrument, including the method of obtaining calibration data, reduction of data, the instrument model, fitting the model to the calibration data, and application of the resulting model solution to sky observations. The instrument model fits well for calibration data that resemble sky condition. The method of propagating detector noise through the calibration process to yield a covariance matrix of the calibrated sky data is described. The final uncertainties are variable both in frequency and position, but for a typical calibrated sky 2.6 deg square pixel and 0.7/cm spectral element the random detector noise limit is of order of a few times 10(exp -7) ergs/sq cm/s/sr cm for 2-20/cm, and the difference between the sky and the best-fit cosmic blackbody can be measured with a gain uncertainty of less than 3%.

Fixsen, D. J.↗

Reduction of hub- and pylon-fairing drag

A wind tunnel test was conducted to obtain data on several drag reduction methods for rotorcraft hubs. The objective of the test was to use small-scale models to develop the technology to substantially reduce hub drag. A helicopter test model, which did not incorporate a rotor, was used to study single-rotor fairing configurations. The rotor shaft assembly was modeled with nonrotating hardware. Drag trend data was obtained for the following fairing configuration changes: hub-fairing camber, hub-fairing thickness ratio, hub-fairing surface curvature, hub-fairing height with respect to the fuselage, inclusion of blade shanks in the hub fairings, hub- and pylon-fairing gaps, pylon-fairing cross-sectional geometry, pylon-fairing thickness ratio and camber. Substantial drag reductions could potentially result from application of the test results to helicopter hub- and pylon-fairing design.

Young, Larry A.↗

Hot-wire anemometry for turbulence measurements in helium-air mixtures

The use of extended hot-wire anemometry involving an interfering probe is shown to permit measurements of variable density turbulence such as arises in the mixing of helium and air. The methods of calibration and data reduction leading to time series in one or more velocity components, in the mass fraction of helium, and in the mixture density are described. Typical results in various flows to which the technique has been applied are discussed.

Libby, P. A.↗

Some comments on particle image displacement velocimetry

Laser speckle velocimetry (LSV) or particle image displacement velocimetry, is introduced. This technique provides the simultaneous visualization of the two-dimensional streamline pattern in unsteady flows as well as the quantification of the velocity field over an entire plane. The advantage of this technique is that the velocity field can be measured over an entire plane of the flow field simultaneously, with accuracy and spatial resolution. From this the instantaneous vorticity field can be easily obtained. This constitutes a great asset for the study of a variety of flows that evolve stochastically in both space and time. The basic concept of LSV; methods of data acquisition and reduction, examples of its use, and parameters that affect its utilization are described.

Lourenco, L. M.↗