Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design Verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

thermal-grid-jba v1.0.0

This is a software repository that contains models for a feasibility study of a thermal energy network for Joint Base Andrews. The work has been conducted under the ESTCP program in the project https://serdp-estcp.mil/projects/details/0694868a-3d58-4a14-a587-b8f638bfcd5c The repository contains models for energy system selection and for verification of design. The DoD management intends to give access to this code for future feasibility studies at Joint Base Andrews and possibly other bases.

Wetter, Michael [Lawrence Berkeley National Labora↗

Optimizing Dynamic Timing Analysis with Reinforcement Learning

There are multiple factors involved in successfully manufacturing ASICIVLSI chips, and ensuring operational specifications are maintained throughout the design and manufacturing process is often challenging. Dynamic timing analysis (DTA) is the principal method used to validate that a manufactured chip complies to its design specifications. In DTA functionality of both synchronous and asynchronous designs are verified by applying input signals and checking for correct output signals. In complex designs where the number of input signal permutations is extremely large, the computing resources required to properly verify the functionality of a chip is prohibitive. In this paper, a strategy using reinforcement learning (RL) for reducing DTA time and resources in such cases is discussed. RL assisted DTA holds much promise in ensuring that VLSI chip design and functionality are fully and optimally verified.

42 ENGINEERING↗

Xyce Case Study

With the elimination of underground nuclear testing and declining defense budgets, science-based stockpile stewardship requires increased reliance on high performance modeling and simulation of weapon systems. Today's weapon systems are comprised of various electrical components and systems. As a result, there is a need for tools that will allow the use of massively parallel modeling and simulation techniques on high performance computers in existing and future weapons' electrical systems models. The Xyce Parallel Electronic Simulator is a SPICE (Simulation Program with Integrated Circuit Emphasis)- compatible circuit simulator designed to run on large-scale parallel computing platforms, though it can also execute efficiently on a variety of architectures including single processor workstations. As a mature platform for large-scale parallel circuit simulation, Xyce supports standard capabilities available in commercial simulators, in addition to various devices and models specific to Sandia's needs. Specifically, Xyce aids in the design and verification of electrical and electronic circuits and systems prior to weapons' manufacturing and deployment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Xyce Case Study

With the elimination of underground nuclear testing and declining defense budgets, science-based stockpile stewardship requires increased reliance on high performance modeling and simulation of weapon systems. Today's weapon systems are comprised of various electrical components and systems. As a result, there is a need for tools that will allow the use of massively parallel modeling and simulation techniques on high performance computers in existing and future weapons' electrical systems models. The Xyce Parallel Electronic Simulator is a SPICE (Simulation Program with Integrated Circuit Emphasis)- compatible circuit simulator designed to run on large-scale parallel computing platforms, though it can also execute efficiently on a variety of architectures including single processor workstations. As a mature platform for large-scale parallel circuit simulation, Xyce supports standard capabilities available in commercial simulators, in addition to various devices and models specific to Sandia's needs. Specifically, Xyce aids in the design and verification of electrical and electronic circuits and systems prior to weapons' manufacturing and deployment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Graph Theory and IC Component Design Analysis

Graph analysis in large integrated circuit (IC) designs is an essential tool for verifying design logic and timing via dynamic timing analysis (DTA). IC designs resemble graphs with each logic gate as a vertex and the conductive connections between gates as edges. Using DTA digital statistical correlations, graph condensation, and graph partitioning, it is possible to identify high-entropy component centers and paths within an IC design. Identification of high-entropy component centers (HECC) enables focused DTA, effectively lowering the computational complexity of DTA on large integrated circuit graphs. In this paper, a devised methodology termed IC layout subgraph component center identification (CCI) is used to identify described. CCI lowers DTA computationally complexity by condensing IC graphs into reduced subgraphs in which dominant logic functions are verified.

42 ENGINEERING↗

Effective Access Monitoring at Geological Repositories

Access points at a deep, mined geological repository (GR) for the disposal of spent nuclear fuel (SNF) and other nuclear wastes present potential diversion paths for nuclear material. Because C/S measures are not likely to be used underground, access to a GR will require unprecedented reliance on C/S measures to maintain continuity of knowledge (CoK) on SNF buried underground. We develop a model GR based on common features of GR designs from national programs in order to develop and optimize C/S measures for GR access points that maximize confidence that CoK is maintained on SNF underground. Critical access points identified in this study are surface entrances to (1) the GR ramp (2) the excavation shaft, (3) the main elevator shaft, and (4) the ventilation shaft. The first three are considered critical detection points (DPs), whereas the fourth is considered a non-critical DP. The reason for the distinction is due to the different design capabilities of shaft components: the first three (ramp, excavation shaft, main elevator) are all capable of being used to move material from the underground to the surface, whereas the ventilation shaft is not. Such capabilities are verified during periodic design information verification (DIV) inspections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurements with Pinhole and Coded Aperture Gamma-Ray Imaging Systems

From a safeguards perspective, gamma-ray imaging has the potential to reduce manpower and cost for effectively locating and monitoring special nuclear material. The purpose of this project was to investigate the performance of pinhole and coded aperture gamma-ray imaging systems at Oak Ridge National Laboratory (ORNL). With the aid of the European Commission Joint Research Centre (JRC), radiometric data will be combined with scans from a three-dimensional design information verification (3D-DIV) system. Measurements were performed at the ORNL Safeguards Laboratory using sources that model holdup in radiological facilities. They showed that for situations with moderate amounts of solid or dense U sources, the coded aperture was able to predict source location and geometry within ~7% of actual values while the pinhole gave a broad representation of source distributions

Raffo-Caiado, Ana Claudia↗

The IAEA Coordinated Research Program on HTGR Reactor Physics, Thermal-hydraulics and Depletion Uncertainty Analysis: Description of the Benchmark Test Cases and Phases

The continued development of High Temperature Gas Cooled Reactors (HTGRs) requires verification of design and safety features with reliable high fidelity physics models and robust, efficient, and accurate codes. The uncertainties in the HTR analysis tools are today typically assessed with sensitivity analysis and then a few important input uncertainties (typically based on a PIRT process) are varied in the analysis to find a spread in the parameter of importance. However, one wish to apply a more fundamental approach to determine the predictive capability and accuracies of coupled neutronics/thermal-hydraulics and depletion simulations used for reactor design and safety assessment. Today there is a broader acceptance of the use of uncertainty analysis even in safety studies and it has been accepted by regulators in some cases to replace the traditional conservative analysis. Finally, there is also a renewed focus in supplying reliable covariance data (nuclear data uncertainties) that can then be used in uncertainty methods. Uncertainty and sensitivity studies are therefore becoming an essential component of any significant effort in data and simulation improvement. In order to address uncertainty in analysis and methods in the HTGR community the IAEA launched a Coordinated Research Project (CRP) on the HTGR Uncertainty Analysis in Modelling early in 2012. The project is built on the experience of the OECD/NEA Light Water Reactor (LWR) Uncertainty Analysis in Best-Estimate Modelling (UAM) benchmark activity, but focuses specifically on the peculiarities of HTGR designs and its simulation requirements. Two benchmark problems were defined with the prismatic type design represented by the MHTGR-350 design from General Atomics (GA) while a 250 MW modular pebble bed design, similar to the INET (China) and indirect-cycle PBMR (South Africa) designs are also included. In the paper more detail on the benchmark cases, the different specific phases and tasks and the latest status and plans are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Model-based Co-Simulation of Heat Pump Water Heater with Phase Change Materials Thermal Energy Storage

The study analysis the behavior of a new developed heat pump water heater technology which integrates a phase change materials storage with a standard heat pump water heater to maximize the performance parameters of the Unified Energy Factor (UEF) and First Hour Rating (FHR). A model-based control development co-simulation platform is developed to include equipment models, such as heat pump, standard water tank, phase change materials storage tank, and integrate them with control model to support controls design, analysis, verification, and validation. Simulation results are compared with lab test results to validate the accuracy of developed co-simulation platform

Sun, Jian↗

Predicting deviations in ex-core detector response in Krsko NPP during an earthquake with Monte-Carlo neutron transport methods

To study the response of ex-core detectors during an earthquake, an approach using Monte Carlo code MCNP was developed. As a first step to predict the response of the ex-core detectors a detailed MCNP model of the Krsko reactor core was created. A detailed MCNP core model was used to calculate 3D power distributions inside the core. Calculated power distributions were verified by comparison to the CORD-2 calculations, which is currently used for core design calculation verification of the Krsko nuclear power plant. Due to the outside the core position of the neutron detectors, the hybrid code ADVANTG is used to generate weight windows to speed up neutron transport outside the reactor core. To be able to use ADVANTG, fixed neutron source had to be reconstructed from the criticality core calculation. It was found that the power range ex-core detector movement has a negligible effect on the value of the thermal neutron flux at the active part of the detector. However, the 5 cm radial movement of the intermediate-range detector leads to 7 % - 8 % change in thermal neutron flux within the active intermediate-range detector region. The analysis continued with the evaluation of the effect of core barrel movement on the ex-core detector response. It was determined that the 2 mm core barrel radial oscillation can lead to ∼ 4% change in thermal neutron flux within the active detector region. It was evaluated that reactor core movement inside the baffle can lead up to ∼ 1.9% and ∼ 1.3% deviation in power-range and intermediate-range detector signal respectively. Analysis showed that the mechanical movement of ex-core neutron detectors could not explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MFANS 2024 - Dimensional Analysis Made Easy

There is a significant impact of dimensional errors in systems. Dimensional analysis is difficult due to the large size of systems. SA4U and Scalpel are practical programs which can have an impact beyond traditional software as they are able to perform precise dimensional analysis and repair C++ source code.

97 MATHEMATICS AND COMPUTING↗

Verification of the PERSENT Software

Ongoing commercial design activities require a thorough verification of the Argonne Reactor Computation codes be performed. DIF3D is central to this system and substantial work has been done to verify its accuracy on several identified commercial needs. This manuscript details the verification work done on PERSENT which relies upon the DIF3D code for its forward and adjoint flux solution. Previous work identified the PERSENT features required to be verified to support commercial design activities, features of which are generally applicable to hexagonal-Z fast reactor designs. The scope of this verification effort includes verifying PERSENT’s ability to correctly calculate four key quantities: perturbation worth distributions, kinetics parameters, sensitivity coefficients, and cross section uncertainty quantification. This manuscript provides the verification tasks and their results with respect to these quantities needed for commercial design activities. For the perturbation worth distributions, hand calculations are deployed to verify the PERSENT calculated results. Similarly, hand calculation of the PERSENT computed kinetics parameters is also used to verify the PERSENT results. In both of these, the input to PERSENT is manipulated to ensure the hand calculation exactly matches the equations PERSENT is calculating. The sensitivity coefficients involve calculating the derivatives of a parameter (such as reactivity worth), with respect to the cross section data. Direct finite difference calculations with DIF3D are used to verify the PERSENT calculated results. For the uncertainty quantification, manufactured input to PERSENT is used to allow an exact hand calculation to reproduce the PERSENT calculated results. The work detailed in this report verified that significant issues were identified for earlier versions of PERSENT for sensitivity coefficients which were corrected in this work and thus version 12.1.0 of PERSENT must be used to reproduce all of the verified work in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of a novel EPID designed for simultaneous imaging and dose verification in radiotherapy

Purpose: Standard amorphous silicon electronic portal imaging devices (a-Si EPIDs) are x-ray imagers used frequently in radiotherapy that indirectly detect incident x-rays using a metal plate and phosphor screen. These detectors may also be used as two-dimensional dosimeters; however, they have a well-characterized nonwater-equivalent dosimetric response. Plastic scintillating (PS) fibers, on the other hand, have been shown to respond in a water-equivalent manner to x-rays in the energy range typically encountered during radiotherapy. In this study, the authors report on the first experimental measurements taken with a novel prototype PS a-Si EPID developed for the purpose of performing simultaneous imaging and dosimetry in radiotherapy. This prototype employs an array of PS fibers in place of the standard metal plate and phosphor screen. The imaging performance and dosimetric response of the prototype EPID were evaluated experimentally and compared to that of the standard EPID.Methods: Clinical 6 MV photon beams were used to first measure the detector sensitivity, linearity of dose response, and pixel noise characteristics of the prototype and standard EPIDs. Second, the dosimetric response of each EPID was evaluated relative to a reference water-equivalent dosimeter by measuring the off-axis and field size response in a nontransit configuration, along with the off-axis, field size, and transmission response in a transit configuration using solid water blocks. Finally, the imaging performance of the prototype and standard EPIDs was evaluated quantitatively by using an image quality phantom to measure the contrast to noise ratio (CNR) and spatial resolution of images acquired with each detector, and qualitatively by using an anthropomorphic phantom to acquire images representative of human anatomy.Results: The prototype EPID's sensitivity was 0.37 times that of the standard EPID. Both EPIDs exhibited responses that were linear with delivered dose over a range of 1–100 monitor units. Over this range, the prototype and standard EPID central axis responses agreed to within 1.6%. Images taken with the prototype EPID were noisier than those taken with the standard EPID, with fractional uncertainties of 0.2% and 0.05% within the central 1 cm{sup 2}, respectively. For all dosimetry measurements, the prototype EPID exhibited a near water-equivalent response whereas the standard EPID did not. The CNR and spatial resolution of images taken with the standard EPID were greater than those taken with the prototype EPID.Conclusions: A prototype EPID employing an array of PS fibers has been developed and the first experimental measurements are reported. The prototype EPID demonstrated a much morewater-equivalent dose response than the standard EPID. While the imaging performance of the standard EPID was superior to that of the prototype, the prototype EPID has many design characteristics that may be optimized to improve imaging performance. This investigation demonstrates the feasibility of a new detector design for simultaneous imaging and dosimetry treatment verification in radiotherapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Risk-Informed Monitoring, Verification and Accounting (RI-MVA): An NRAP White Paper Documenting Methods and a Demonstration Model for Risk-Informed MVA System Design and Operations in Geologic Carbon Sequestration

This white paper accompanies a demonstration model that implements methods for the risk-informed design of monitoring, verification and accounting (RI-MVA) systems in geologic carbon sequestration projects. The intent is that this model will ultimately be integrated with, or interfaced with, the National Risk Assessment Partnership (NRAP) integrated assessment model (IAM). The RI-MVA methods described here apply optimization techniques in the analytical environment of NRAP risk profiles to allow systematic identification and comparison of the risk and cost attributes of MVA design options.

carbon sequestration↗

Design, dynamic modeling and wave basin verification of a Hybrid Wave–Current Energy Converter

Massive and high-density Marine and Hydrokinetic (MHK) energy is contained in the ocean, including waves, tidal streams, and ocean currents. Traditional MHK energy converters harvest energy from only a single MHK energy source, which does not fully exploit the energy potential that co-exists in multiple forms of MHK energy in the ocean. This paper presents the design and dynamics of a Hybrid Wave–Current Energy Converter (HWCEC) that can simultaneously convert both wave and current energy to electricity with a single Power Take-off (PTO) through the engagement and disengagement of the three one-way clutches. The critical design parameters are analyzed through modeling and simulation, including the transmission ratios, the electrical impedance, and the turbine-heave plate distance. Water basin tests in a wave–current tank were conducted, which shows the prototyped HWCEC can improve the electric power output by 38%–71% for regular waves and 79% for irregular waves, while providing a 70% reduction of the Peak to Average Ratio (PAR) of power compared to the baseline Wave Energy Converter (WEC). Here we further analyze the occurring percentages of the instant power of both WEC and HWCEC in irregular wave tests, shedding new insight on how HWCEC reduces the PAR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-D-BRC-03: Development and Validation of an Online 2D Dose Verification System for Daily Patient Plan Delivery Accuracy Check

Purpose: All plan verification systems for particle therapy are designed to do plan verification before treatment. However, the actual dose distributions during patient treatment are not known. This study develops an online 2D dose verification tool to check the daily dose delivery accuracy. Methods: A Siemens particle treatment system with a modulated scanning spot beam is used in our center. In order to do online dose verification, we made a program to reconstruct the delivered 2D dose distributions based on the daily treatment log files and depth dose distributions. In the log files we can get the focus size, position and particle number for each spot. A gamma analysis is used to compare the reconstructed dose distributions with the dose distributions from the TPS to assess the daily dose delivery accuracy. To verify the dose reconstruction algorithm, we compared the reconstructed dose distributions to dose distributions measured using PTW 729XDR ion chamber matrix for 13 real patient plans. Then we analyzed 100 treatment beams (58 carbon and 42 proton) for prostate, lung, ACC, NPC and chordoma patients. Results: For algorithm verification, the gamma passing rate was 97.95% for the 3%/3mm and 92.36% for the 2%/2mm criteria. For patient treatment analysis,the results were 97.7%±1.1% and 91.7%±2.5% for carbon and 89.9%±4.8% and 79.7%±7.7% for proton using 3%/3mm and 2%/2mm criteria, respectively. The reason for the lower passing rate for the proton beam is that the focus size deviations were larger than for the carbon beam. The average focus size deviations were −14.27% and −6.73% for proton and −5.26% and −0.93% for carbon in the x and y direction respectively. Conclusion: The verification software meets our requirements to check for daily dose delivery discrepancies. Such tools can enhance the current treatment plan and delivery verification processes and improve safety of clinical treatments.

60 APPLIED LIFE SCIENCES↗