Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Data Trend Shifts Induced by Method of Concentration for Trace Metals in Seawater: Automated Online Preconcentration vs Borohydride Reductive Coprecipitation of Nearshore Seawater Samples for Analysis of Ni, Cu, Zn, Cd, and Pb via ICP-MS

This research compares performance, reproducibility, and detection limits of ambient seawater analysis for trace metals using both borohydride reductive co-precipitation and an automated chelation column (seaFAST™ 2) co-preconcentration for matrix interferent elimination on total and dissolved grab samples in nearshore to marine waters, over a broad concentration range, prior to ICP-MS injection. A move to an online preconcentration method both minimizes sample preparation, and eliminates correction errors when accounting for trace impurities in precipitated samples, induced via reagents. The reproducability of the online preconcentration method described, coupled with low blanks and method detection limits (MDLs), demonstrates an effective move to an automated procedure using ethylenediaminetriacetic and iminodiacetate acid chelation exchange resin and multi-analyte determination via ICP-MS for total and dissolved Ni, Cu, Zn, Cd, and Pb in marine water samples. Average CASS-5 recoveries using the online preconcentration method (n=9) were 109±7%, 104±5%, 103±7%, 101±3%, and 86±8% respectively. The MDLs obtained from the automated method for Ni, Cu, Zn, Cd and Pb were 3.3, 1.8, 13.5, 4, and 10 times lower, respectively, than for the Borohydride method. There were statistically significant differences between the methods for CASS-5 recoveries of Ni, Cu, Zn (p < 0.0001), and Pb (p = 0.0024). Comparison of methods gave high concordance (rC = 0.90) between methods for total and dissolved Ni, Cu, Zn, and Pb, and total Cd.

seaFAST, borohydride, seawater, Ethylenediaminetet↗

2016 Floodplain Geochemistry from the East River Watershed, Colorado

This dataset includes groundwater geochemistry data from floodplain piezometers collected as a part of the Watershed Function Scientific Focus Area (SFA) located in the Upper Colorado River Basin. The data were collected in order to investigate the role of hyporheic exchange and other river corridor processes on riverine export of solutes. Floodplain piezometers installed in several meanders (Meander C, Meander D, and Meander O) in the vicinity of the Pumphouse were sampled at several dates in 2016. Data includes in-field measurements (pH, electrical conductivity, oxidation reduction potential, dissolved oxygen, dissolved Fe(II), dissolved sulfide, and groundwater level) along with laboratory measurements (dissolved inorganic carbon, dissolved organic carbon, metals and major cations). Five files are included in this dataset, including: sample locations and depths in a csv file (metadata.csv), aqueous geochemistry data in a csv file, analytical detection limits in a csv file, a file-level metadata (flmd.csv) file, and a data dictionary (dd.csv) file. Data that was below the detection limit is reported as one half of the detection limit and missing data is listed as "-9999".

54 ENVIRONMENTAL SCIENCES↗

THE SLOAN DIGITAL SKY SURVEY STRIPE 82 IMAGING DATA: DEPTH-OPTIMIZED CO-ADDS OVER 300 deg{sup 2} IN FIVE FILTERS

We present and release co-added images of the Sloan Digital Sky Survey (SDSS) Stripe 82. Stripe 82 covers an area of ∼300 deg{sup 2} on the celestial equator, and has been repeatedly scanned 70-90 times in the ugriz bands by the SDSS imaging survey. By making use of all available data in the SDSS archive, our co-added images are optimized for depth. Input single-epoch frames were properly processed and weighted based on seeing, sky transparency, and background noise before co-addition. The resultant products are co-added science images and their associated weight images that record relative weights at individual pixels. The depths of the co-adds, measured as the 5σ detection limits of the aperture (3.''2 diameter) magnitudes for point sources, are roughly 23.9, 25.1, 24.6, 24.1, and 22.8 AB magnitudes in the five bands, respectively. They are 1.9-2.2 mag deeper than the best SDSS single-epoch data. The co-added images have good image quality, with an average point-spread function FWHM of ∼1'' in the r, i, and z bands. We also release object catalogs that were made with SExtractor. These co-added products have many potential uses for studies of galaxies, quasars, and Galactic structure. We further present and release near-IR J-band images that cover ∼90 deg{sup 2} of Stripe 82. These images were obtained using the NEWFIRM camera on the NOAO 4 m Mayall telescope, and have a depth of about 20.0-20.5 Vega magnitudes (also 5σ detection limits for point sources)

79 ASTRONOMY AND ASTROPHYSICS↗

SEARCHING FOR GAS GIANT PLANETS ON SOLAR SYSTEM SCALES: VLT NACO/APP OBSERVATIONS OF THE DEBRIS DISK HOST STARS HD172555 AND HD115892

Using the Apodizing Phase Plate (APP) coronagraph of Very Large Telescope/NACO we searched for planetary mass companions around HD115892 and HD172555 in the thermal infrared at 4 {mu}m. Both objects harbor unusually luminous debris disks for their age and it has been suggested that small dust grains were produced recently in transient events (e.g., a collision) in these systems. Such a collision of planetesimals or protoplanets could have been dynamically triggered by yet unseen companions. We did not detect any companions in our images but derived the following detection limits: for both objects we would have detected companions with apparent magnitudes between {approx}13.2 and 14.1 mag at angular separations between 0.''4 and 1.''0 at the 5{sigma} level. For HD115892 we were sensitive to companions with 12.1 mag even at 0.''3. Using theoretical models these magnitudes are converted into mass limits. For HD115892 we would have detected objects with 10-15 M{sub Jup} at angular separations between 0.''4 and 1.''0 (7-18 AU). At 0.''3 ({approx}5.5 AU) the detection limit was {approx}>25 M{sub Jup}. For HD172555 we reached detection limits between 2 and 3 M{sub Jup} at separations between 0.''5 and 1.''0 (15-29 AU). At 0.''4 ({approx}11 AU) the detection limit was {approx}>4 M{sub Jup}. Despite the non-detections, our data demonstrate the unprecedented contrast performance of NACO/APP in the thermal infrared at very small inner working angles and we show that our observations are mostly background limited at separations {approx}>0.''5.

79 ASTRONOMY AND ASTROPHYSICS↗

BEBOP II: sensitivity to sub-Saturn circumbinary planets using radial-velocities

ABSTRACT BEBOP is a radial-velocity survey that monitors a sample of single-lined eclipsing binaries, in search of circumbinary planets by using high-resolution spectrographs. Here, we describe and test the methods we use to identify planetary signals within the BEBOP data and establish how we quantify our sensitivity to circumbinary planets by producing detection limits. This process is made easier and more robust by using a diffusive nested sampler. In the process of testing our methods, we notice that contrary to popular wisdom, assuming circular orbits in calculating detection limits for a radial-velocity survey provides overoptimistic detection limits by up to $40{{\ \rm per\ cent}}$ in semi-amplitude with implications for all radial-velocity surveys. We perform example analyses using three BEBOP targets from our Southern HARPS survey. We demonstrate for the first time a repeated ability to reach a residual root mean squared scatter of $3\, \rm m\, s^{-1}$ (after removing the binary signal), and find that we are sensitive to circumbinary planets with masses down to that of Neptune and Saturn, for orbital periods up to $1000\, \rm d$.

Standing, Matthew R. (ORCID:0000000276088905)↗

Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in. × 2 in.) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm 2 , where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results will be discussed in a subsequent report.

59 BASIC BIOLOGICAL SCIENCES↗

Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in × 2 in) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2, where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results are discussed in a separate report.

59 BASIC BIOLOGICAL SCIENCES↗

Highly selective luminescent sensing of picric acid based on a water-stable europium metal-organic framework

A water-stable metal-organic framework (MOF) EuNDC has been synthesized for selective detection of the well-known contaminant and toxicant picric acid (PA) in aqueous solution. Due to the photo-induced electron transfer and self-absorption mechanism, EuNDC displayed rapid, selective and sensitive detection of PA with a detection limit of 37.6 ppb. Recyclability experiments revealed that EuNDC retains its initial luminescent intensity and same quenching efficiency in each cycle, suggesting high photostability and reusability for long-term sensing applications. The excellent detection performance of EuNDC makes it a promising PA sensing material for practical applications. - Graphical abstract: A water-stable europium-based metal-organic framework has been reported for highly selective sensing of picric acid (PA) with a detection limit of 37.6 ppb in aqueous solution. - Highlights: • A water-stable metal-organic framework (MOF) EuNDC was synthesized. • The highly selective detection of picric acid with a detection limit of 37.6 ppb was realized. • The detection mechanism were also presented and discussed.

36 MATERIALS SCIENCE↗

False-negative rate, limit of detection and recovery efficiency performance of a validated macrofoam-swab sampling method for low surface concentrations of Bacillus anthracis Sterne and Bacillus atrophaeus spores

The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in × 2 in) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS and 40.2% with BG) and the highest for glass (92.8% with BAS and 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG; values increased as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results will be discussed in a subsequent article.

Bacillus anthracis↗

Redox-Based Electrochemical Affinity Sensor for Detection of Aqueous Pertechnetate Anion

Rapid, selective, in-situ detection of TcO4- in multicomponent matrices consisting of interfering anions such as the ubiquitous NO3- and Cl- or the isostructural and isoelectronic CrO42- is challenging. Present sensors mostly lack the selectivity to exclude these interferences, or the sensitivity to meet the detection limits that are lower than the drinking water standards across the globe. This work presents an affinity based electrochemical sensor for TcO4- detection that relies on selective reductive precipitation of aqueous TcO4- induced by a capture probe immobilized on an electrode platform. This results in a direct decrease of the electron transfer current, the magnitude of the decrease being proportional to the amount of TcO4- added. Using this approach, we were able to achieve a detection limit of 1x10-10 M, which is lower than the drinking water standard of 5.2x10-10 M set by United States Environmental Protection Agency. Our proposed approach also allowed us to detect TcO4- from a multicomponent groundwater sample obtained from a well at the Hanford site in Washington (well 299-W19-36) that also contained NO3- , Cl- and CrO42-, without discernably affecting the detection limits.

Chatterjee, Sayandev↗

A novel vacuum spectrometer for total reflection x-ray fluorescence analysis with two exchangeable low power x-ray sources for the analysis of low, medium, and high Z elements in sequence

The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm{sup 2} active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of false-negative rates and limits of detection following macrofoam-swab sampling of Bacillus anthracis surrogates via Rapid Viability PCR and plate culture

Aims: We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials, and assay methods on false-negative rate (FNR) and limit of detection (LOD95) for recovering Bacillus spores using a macrofoam-swab sampling procedure. Methods and Results: Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2 – 500 coupon-1) onto glass, stainless steel, vinyl tile, and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD95 results. Conclusions: Mean FNRs tended to be lower for mRV-PCR compared to culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD95 was lowest for glass and highest for vinyl tile. LOD95 values overall were lower for mRV-PCR than for the culture method. Significance and Impact of Study: This study adds to the limited data on FNR and LOD95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis.

Bacillus spores↗

Ne ISOTOPES IN INDIVIDUAL PRESOLAR GRAPHITE GRAINS FROM THE MURCHISON METEORITE TOGETHER WITH He, C, O, Mg-Al ISOTOPIC ANALYSES AS TRACERS OF THEIR ORIGINS

Ne isotopes measured in individual presolar graphite grains, solid samples of extinct stars preserved in primitive meteorites, provide information on the type of stellar sources of the grains and on nucleosynthetic mixing and ion-trapping processes which were operating. We present Ne and He isotope analyses of single presolar graphite grains from the KFB1 density fraction extracted from the carbonaceous chondrite Murchison. In addition, we measured isotopes of C, O, and Mg-Al with the NanoSIMS ion microprobe to better constrain the origin of the grains. Eleven out of 51 presolar graphite grains contain nucleosynthetic {sup 22}Ne above our detection limit. This fraction of {sup 22}Ne-rich grains is similar to the one reported by Nichols et al. although we have a lower {sup 22}Ne detection limit. We detected rare He-shell {sup 20}Ne in one {sup 22}Ne-rich grain and obtained the {sup 20}Ne/{sup 22}Ne ratio (0.03 {+-} 0.02) of the He-shell of an Asymptotic Giant Branch (AGB) star with 1.5-2 M {sub sun} and subsolar metallicity. We also detected {sup 4}He in this grain, while in the other grains, which originally acquired He, He-loss seems to be significant. We found unequivocal evidence for radiogenic {sup 22}Ne (Ne-R) in another graphite grain, which likely condensed in a core-collapse supernova and which incorporated live radioactive {sup 22}Na (t {sub 1/2} = 2.6 yr). For the other grains, a clear assignment to a stellar source is more difficult to make. Putative stellar sources are supernovae, AGB stars, born-again AGB stars, J-type carbon stars, and CO novae.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining Accretion Signatures of Exoplanets in the TW Hya Transitional Disk

We present a near-infrared direct imaging search for accretion signatures of possible protoplanets around the young stellar object (YSO) TW Hya, a multi-ring disk exhibiting evidence of planet formation. The Paβ line (1.282 μm) is an indication of accretion onto a protoplanet, and its intensity is much higher than that of blackbody radiation from the protoplanet. We focused on the Paβ line and performed Keck/OSIRIS spectroscopic observations. Although spectral differential imaging (SDI) reduction detected no accretion signatures, the results of the present study allowed us to set 5σ detection limits for Paβ emission of 5.8 × 10{sup −18} and 1.5 × 10{sup −18} erg{sup −1} s{sup −1} cm{sup −2} at 0.″4 and 1.″6, respectively. We considered the mass of potential planets using theoretical simulations of circumplanetary disks and hydrogen emission. The resulting masses were 1.45 ± 0.04 M {sub J} and 2.29{sub −0.04}{sup +0.03} M{sub J} at 25 and 95 au, respectively, which agree with the detection limits obtained from previous broadband imaging. The detection limits should allow for the identification of protoplanets as small as ∼1 M {sub J}, which may assist in direct imaging searches around faint YSOs for which extreme adaptive optics instruments are unavailable.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of impurities in cubic boron nitride (cBN) by inductively coupled plasma mass spectrometry (ICPMS)

The phase stability of cBN is critically dependent on the content and amount of impurities present. While studies have shown qualitatively that the addition of certain impurities can either increase or decrease the cBN-hBN phase transition temperature, studies have yet to show this effect quantitatively. This is because analytical methods to characterize minor and trace impurities in cBN are currently lacking. To this end, we present flux fusion methods capable of fully digesting cBN samples for ICPMS analyses. The materials used in this study are commercially available cBN powders in three different sizes. Two types of fluxes (LiOH and NaOH·H 2 O) are utilized so that both Li and Na impurities can be determined. To ensure the accuracy of Si measurements, a column chromatography method has been developed to purify Si from flux materials in order to increase the amount of dissolved sample sent to the ICP. Detection limits have been determined using procedural blanks and are found to be below 20 μg/g for all 58 elements analyzed except for Si, for which the detection limit is 312 μg/g. Nonetheless, all cBN powders studied are found to have high Si impurity levels that are above detection limit. This study provides a much-needed analytical protocol to enable comprehensive screening of impurities in cBN.

36 MATERIALS SCIENCE↗

Spectroelectrochemical Sensor for Spectroscopically Hard-to-detect Metals by in situ Formation of a Luminescent Complex Using Ru(II) as a Model Compound

Fast, robust, and cost-effective means of detecting spectroscopically inactive metal species are necessary for field detection and applications within a variety of areas including industry and the nuclear safeguards fields. A sensor based on spectroelectrochemistry is an excellent candidate to meet these needs as it provides improved selectivity for specifically quantifying metal ions by simultaneously monitoring at least two physio-chemical properties. Ruthenium was chosen as a model system for this study due to its spectroscopic and electrochemical characteristics as well as its relevance within the fuel cycle and industrial fields. Aqueous Ru displays multiple redox couples in which all available oxidation states have poor sensitivity for detection by visible absorption spectroscopy because of the low molar absorptivities. Ru can, however, form complexes with sensitizing ligands such as 2,2'-bipyridine, where the resulting [Ru(ligand)3]2+ complex displays a red luminescence with a high quantum yield of emission. This significantly improves detection limits for Ru and allows for the spectroelectrochemical detection of the otherwise hard-to-detect metal ion. This work explores the in-situ generation of Ru(bpy)3 complexes in simulated field samples and their subsequent spectroelectrochemical sensing using our sensor methodology.

Lines, Amanda M.↗

Universal human papillomavirus typing by whole genome sequencing following target enrichment: evaluation of assay reproducibility and limit of detection

We recently described a method for unbiased detection of all known human papillomaviruses (HPV) types with the potential for the determination of their variant and integration from the resulting whole genome sequence data. Considering the complex workflow for target-enriched next generation sequencing (NGS), we focused on the reproducibility and limit of detection (LOD) of this new universal HPV typing assay in this study. We evaluated the reproducibility and LOD for HPV genotyping based on our recently published method that used RNA-baits targeting whole genomes of 191 HPV types, Agilent SureSelect protocol for target enrichment and Illumina HiSeq 2500 for sequencing (eWGS, enriched whole genome sequencing). Two libraries, prepared from pooled plasmids representing 9 vaccine HPV types at varying input (1–625 copies/reaction), were sequenced twice giving four replicates for evaluating reproducibility and LOD. eWGS showed high correlation in the number of reads mapped to HPV reference genomes between the two flow-cell lanes within (R 2 = 1) and between experiments (R 2 = 0.99). The number of mapped reads was positively correlated to copy number (β = 13.9, p < 0.0001). The limit of blank (LOB) could be calculated based on mapped reads to HPV types not included in each sample. HPV genotyping was reproducible for all 9 types at 625 copies using multiple cut-off criteria but LOD was 25 copies based on number of reads above LOB even when multiple types were present. eWGS showed no bias for HPV genotyping under single or multiple infection (p = 0.16–0.99). The universal eWGS method for HPV genotyping has sensitivity, competitive with widely used consensus PCR methods with reduced type competition, and with the potential for determination of variant and integration status. The protocol used in this study, using defined samples varying in complexity and copy number, analyzed in replicate and duplicate assays, is applicable to most WGS methods.

59 BASIC BIOLOGICAL SCIENCES↗

Chemical detection demonstrated using an evanescent wave graphene optical sensor

Graphene devices have been constructed on silicon mirrors, and the graphene is optically probed through an evanescent wave interaction in an attenuated total reflectance configuration using an infrared spectrometer. The graphene is electrically biased in order to tune its optical properties. Exposure of the device to the chemicals iodine and ammonia causes observable and reversible changes to graphene's optical absorption spectra in the mid to near infrared range which can be utilized for the purpose of sensing. Electrical current measurements through the graphene are made simultaneously with optical measurements allowing for simultaneous sensing using two separate detection modalities. Our current results reveal sub-ppm detection limits for iodine and approximately 100 ppm detection limits for ammonia. We have also demonstrated that this approach will work at 1.55 μm, which opens up the possibility for graphene optical sensors that leverage commercial telecom light sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗