Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Solenoid With Partial Yoke for the Dune Near Detector

The Deep Underground Neutrino Experiment (DUNE) at Fermilab is one the most challenging next-generation experiments in the field of neutrino physics. It will feature two detectors for a detailed study of neutrino oscillations using an unprecedentedly intense neutrino beam. The two detectors are a Near Detector located on the Fermilab site, 574 m away from the neutrino generation, and a Far Detector in South Dakota, 1300 km away. The Near Detector consists of three subdetectors, based on different technologies in order to achieve the best understanding of the neutrino beam. One key element of the Near Detector is a High Pressure Argon TPC surrounded by a calorimeter. This detector will need a 0.5 Tesla magnetic field transverse to the neutrino beam direction, with a 7 m diameter, 8 m long warm bore. A thin superconducting solenoid with a partial yoke, needed in order to minimise the amount of material along the path particles take crossing the different elements of the Near Detector is proposed. In this paper we present a detailed magnetic analysis and a preliminary study of the cooling, the cable and the mechanics for this magnet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The scintillator surface detector of the Pierre Auger observatory

Data collected so far by the Pierre Auger Observatory have enabled major advances in ultra-high energy cosmic ray physics and demonstrated that improved determination of masses of primary cosmic-ray particles, preferably on an event-by-event basis, is necessary for understanding their origin and nature. Improvement in primary mass measurements was the main motivation for the upgrade of the Pierre Auger Observatory, called AugerPrime. As part of this upgrade, scintillator detectors are added to the existing water-Cherenkov surface detector stations. By making use of the differences in detector response to the electromagnetic particles and muons between scintillator and water-Cherenkov detectors, the electromagnetic and muonic components of cosmic-ray air showers can be disentangled. Since the muonic component is sensitive to the primary mass, such combination of detectors provides a powerful way to improve primary mass composition measurements over the original Auger surface detector design. In this paper, the so-called Scintillator Surface Detectors are discussed, including their design characteristics, production process, testing procedure and deployment in the field.

Detector design and construction technologies and ↗

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

3x3 array module of 8×8×32 mm 3 position-sensitive virtual frisch-grid CdZnTe detectors for imaging and spectroscopy of cosmic gamma-rays

Here, we evaluated the performance of the 3x3 array of 32-mm long position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors read out by the IDEAS GDS-100 data acquisition system. The array is a mechanically solid module designed for integration into a large effective area gamma-ray telescope proposed for imaging and spectroscopy of cosmic gamma-rays. The array employs the bar-shaped 8x8x32 mm 3 CZT crystals which recently became available from Redlen Technologies, Inc. and Kromek-eV Group PLC at affordable costs. The waveform sampling IDE3421 application-specific integrated circuit (ASIC), developed by the University of Michigan and IDEAS for CZT pixel detectors, was adapted to capture the signals from the array's VFG detectors. We showed good spectral performance of the Redlen detectors with an energy resolution of <1% FWHM at 662 keV and slightly poorer performance of the Kromek-eV detectors with a resolution of <2% measured at a reduced temperature of 13 °C. By testing the same detectors as single devices using hybrid charge-sensitive preamplifiers, we demonstrated improved energy resolutions at a normal temperature of ~25°C: <1% and 1.3-1.7%, respectively. However, the Kromek-eV detectors did not perform as well as the Redlen ones. We explained this by the space charge formation (polarization) decreasing the electric field and the electron drift times. The polarization was likely caused by the high injections of holes from the anode contacts. The absence of polarization in Redlen detectors suggested that the quality of the contacts might have played a role in this case.

47 OTHER INSTRUMENTATION↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MeV-scale performance of water-based and pure liquid scintillator detectors

This paper presents studies of the performance of water-based liquid scintillators (WbLS) in both 1-kt and 50-kt detectors. In this work, performance is evaluated in comparison to both pure water Cherenkov detectors and a nominal model for pure scintillator detectors. Performance metrics include energy, vertex, and angular resolution, along with a metric for the ability to separate the Cherenkov from the scintillation signal as being representative of various particle identification capabilities that depend on the Cherenkov/scintillation ratio. We also modify the time profile of scintillation light to study the same performance metrics as a function of rise and decay time. We go on to interpret these results in terms of their impact on certain physics goals, such as solar neutrinos and the search for Majorana neutrinos. This work supports and validates previous results, and the assumptions made therein, and serves as a significant stepping stone to complete detector design studies by using a more detailed detector model and full reconstruction, with a primarily data-driven optical model, and fewer model assumptions. With this model, a high-coverage 50-kt detector achieves better than 10 (1)% precision on the flux of neutrinos from the Carbon-Nitrogen-Oxygen cycle with a water-based liquid scintillator (pure LS) target in five years of data taking. A 1-kt LS detector, with a conservative 50% fiducial volume of 0.5 kt, can achieve better than 5% detection. A liquid scintillator detector has sensitivity into the normal hierarchy region for Majorana neutrinos with half-life sensitivity of $T^{0νββ}_{1/2}$ > 1.4 × 10 28 years at 90% C.L. for 10 years of data taking with a Te-loaded target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic Detector Development for SuperCDMS

The dark matter (DM) problem is currently one of the most pressing issues facing physics. This thesis presents some of my work and contributions to the detectors employed by the Super Cryogenic Dark Matter Search (SuperCDMS), one of the many experiments currently investigating DM. First, we present an overview of astrophysical and cosmological observations to give insight into our current understanding of DM and its role in the universe. Some potential particle DM candidates are also discussed. Then we describe the SuperCDMS experiment and relevant detector technologies. We go into particular detail in discussing the phonon sensors, deriving the relationships that define their fundamental working principles and describing their practical deployment. We also discuss the main noise contributions to the phonon sensors which can limit experimental sensitivity. We then present some work related to reconstruction of event position in the detectors, including new analysis techniques and a n ovel cryogenic calibration source mover we have developed and tested. We also present tests of improving experimental scalability by increasing individual detector masses using the largest-diameter cryogenic Si detectors yet operated. We present first experimental results from the novel use of $(n,\gamma)$ processes to calibrate the low energy nuclear recoil energy scale. This work is essential to understand how DM-nuclear interactions will manifest in semiconductor detectors. We also take a short look at the newest, most sensitive detectors currently operated by SuperCDMS and discuss how they are allowing new insights into critical physics processes in all SuperCDMS detectors. Finally, we demonstrate how some of the various improvements discussed in this work can improve the experimental reach of the next generation of SuperCDMS at SNOLAB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near Detector Selection for Neutral Current Disappearance Search at the Short-Baseline Neutrino Program

Various short baseline neutrino experiments observe anomalies that challenge the three-flavor neutrino oscillation model, consistent with a hypothetical “sterile” neutrino that does not interact via the weak force. This poster presents a near detector event selection at the Short-Baseline Near Detector (SBND), developed for the first search for neutral current (NC) disappearance at short-baseline experiments. NC disappearance provides ``smoking gun” insight into the sterile neutrino question because NC interactions are equally sensitive to all three active neutrinos, meaning any change in the NC interaction rate between near and far detectors cannot be explained by oscillations among known flavor states. This analysis focuses on the NC1p topology, the most common NC interaction type at the Short-Baseline Neutrino (SBN) Program. NC topologies are inherently challenging due to their low light yield and the absence of an outgoing charged lepton, which complicates identification and leads to poor energy reconstruction as the outgoing neutrino carries away a large portion of the neutrino’s initial energy. This work presents an NC1p event selection at the near detector, highlighting SBND’s impressive detector capabilities, including trigger efficiency studies. Combined with a novel kinematic energy reconstruction technique leveraging the detector’s outstanding hadronic detail, this analysis establishes a robust near detector foundation to target an NC disappearance measurement consistent with the 3$+$1 sterile neutrino model. This SBND selection will soon be combined with the far detector to conduct an NC disappearance search, providing unique insight and complementary information to traditional charged current searches and advancing the SBN Program’s goal to resolve the sterile neutrino question, including 3$+$1 searches and beyond.

Nicole Pallat, Nicole Pallat [Minnesota U.] (ORCID↗

Future Advances in Photon-Based Neutrino Detectors: A SNOWMASS White Paper

We discuss here new, enabling technologies for future photon-based neutrino detectors. These technologies touch nearly every aspect of such detectors: new scintillating materials, new methods of loading isotopes, new photon sensors and collectors, new approaches to simulation and analysis, and new front-end electronics and DAQ ideas. Of particular interest are technologies that enable broad physics programs in hybrid Cherenkov/scintillation detectors, such as slow fluors, water-based liquid scintillator, and spectral sorting of photons. Several new large-scale detector ideas are also discussed, including hybrid detectors like Theia, ArTEMIS, and generic slow-fluor detectors, as well as the very different SLIPs and LiquidO approaches to instrumenting photon-based detectors. A program of demonstrators for future detectors, including ANNIE, Eos, and NuDOT are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light and Dark in Liquid Argon Time Projection Chamber Neutrino Detectors

Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors have emerged as a detector technology poised to perform measurements of neutrino interactions with unprecedented precision and as a result answer some of the largest open questions in neutrino physics in the coming decade. This thesis describes methods developed to tackle the computational challenges faced as LArTPC detectors increase in scale and complexity moving towards the multi-kiloton DUNE detectors. These include a new, approximated, model that enables rapid simulation of scintillation light in very large scale detectors, as well as the first demonstration of running the LArSoft software framework on a high performance computer. The high precision of LArTPC detectors designed for next-generation neutrino measurements enables them to also search for Beyond the Standard Model physics produced in high-energy proton--fixed-target collisions in neutrino beams. This thesis presents searches for two dark-sector models performed with the ArgoNeuT experiment: Heavy Neutral Leptons and Heavy QCD Axions. Between them, these models can provide solutions for various unresolved puzzles including neutrino mass generation, the baryon asymmetry of the universe, dark matter and the strong CP problem. In both cases, the dark-sector particles could be produced in the NuMI neutrino beam and can then decay to a pair of oppositely charged muons observable in ArgoNeuT and the downstream MINOS near detector. Both measurements required the development of novel experimental selection techniques and enabled new constraints to be set on the existence of these particles in previously unexplored parameter-space. These searches are both the first of their kind in LArTPC neutrino detectors and pave the way for searches at future neutrino facilities.Date of Award31 Dec 2022Original languageEnglishAwarding InstitutionThe University of ManchesterSupervisorStefan Soldner-Rembold (Supervisor) & Justin Evans (Supervisor)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗

Performance of the ATLAS RPC detector and Level-1 muon barrel trigger at √(s)=13 TeV

The ATLAS experiment at the Large Hadron Collider (LHC) employs a trigger system consisting of a first-level hardware trigger (L1) and a software-based high-level trigger. The L1 muon trigger system selects muon candidates, assigns them to the correct LHC bunch crossing and classifies them into one of six transverse-momentum threshold classes. The L1 muon trigger system uses resistive-plate chambers (RPCs) to generate the muon-induced trigger signals in the central (barrel) region of the ATLAS detector. The ATLAS RPCs are arranged in six concentric layers and operate in a toroidal magnetic field with a bending power of 1.5 to 5.5 Tm. The RPC detector consists of about 3700 gas volumes with a total surface area of more than 4000 m2. This paper reports on the performance of the RPC detector and L1 muon barrel trigger using 60.8 fb-1 of proton-proton collision data recorded by the ATLAS experiment in 2018 at a centre-of-mass energy of 13 TeV. Detector and trigger performance are studied using Z boson decays into a muon pair. Measurements of the RPC detector response, efficiency, and time resolution are reported. Measurements of the L1 muon barrel trigger efficiencies and rates are presented, along with measurements of the properties of the selected sample of muon candidates. Measurements of the RPC currents, counting rates and mean avalanche charge are performed using zero-bias collisions. Finally, RPC detector response and efficiency are studied at different high voltage and front-end discriminator threshold settings in order to extrapolate detector response to the higher luminosity expected for the High Luminosity LHC.

47 OTHER INSTRUMENTATION↗

A Custom Low-Noise Silicon Photodiode Detector Designed for Use With X-Ray Capillary Optics

We present the first results of a custom low-noise silicon photodiode detector designed for use with X-ray capillary optics. This system is intended to perform as a smaller, lighter, and low-powered alternative to currently existing X-ray telescope technologies. The detector has an active area with a diameter of 100 μm, and its small size leads to a low capacitance of well under 1 pF and a leakage current of 1 pA or less at the depletion voltage. We tested the detector with both a discrete preamp and an ultralow-noise front-end application-specific integrated circuit (ASIC). The front-end ASIC, developed at Brookhaven National Laboratory, was designed for low-capacitance detectors but had not been previously tested with a detector. Here, we discuss the detector design, the experimental setup, and the resulting detector performance. Using radioactive laboratory sources, we measure a full-width at half-maximum (FWHM) of 211 ± 8 eV at 5.9 keV with the ASIC and are able to set the threshold as low as 0.6 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Massive, Position-Resolving, High-Energy-Resolution Detector for Non-Accelerator Cosmic and Intensity Frontier Particle Physics

We proposed to take the first steps in the development of a detector that promises energy resolution of tens of eV FWHM combined with robust nuclear-recoil discrimination and high fidelity, mm-precision position reconstruction for applications in non-accelerator particle physics at the Cosmic and Intensity Frontiers. The detector would obtain these excellent resolutions by sensing athermal phonons produced by particle interactions in crystalline, dielectric targets using a sensitive, highly multiplexable superconducting phonon sensor, the kinetic inductance detector (KID). This detector would be applicable to: the search for low-mass particle dark matter candidates with masses below 5~GeV via direct detection of scattering of dark matter particles with terrestrial nuclei; detection of coherent elastic neutrino-nucleus scattering to test for new physics such as a non-standard value of the weak nuclear charge, non-standard neutrino interactions (perhaps driven by a neutrino magnetic moment), or the existence of sterile neutrinos; and, searches for neutrinoless double-beta decay. During the funding period, we demonstrated scaling up of the detector concept from a 22-mm by 22-mm by 1-mm, 1-g prototype with 0.9~keV FWHM energy resolution to a 75-mm diameter by 1-mm, 9-g prototype while improving the inferred energy resolution to 0.7~keV~FWHM. In the process, we solved many problems associated with scaling device fabrication to large wafers and vastly reduced the fraction of the surface occupied by inactive but energy-absorbing metal. We also demonstrated a new technique that substantially simplifies the process of characterizing a new detector. These results provide a good foundation for future work scaling up the design to 4-mm thickness substrates and improving the resolution to reach 0.035~keV~FWHM, yielding a detector with compelling potential for the above applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗