INS–Support for Formal Cyber Security Education in Brazil–After Action Report

The adoption of digital technology into Instrumentation and Control (I&C) systems in nuclear facilities fundamentally changes the nature of these systems. Greater interconnectivity of reprogrammable, and functionally interdependent control systems has given rise to the need for computer security consideration in digital I&C Systems. The cyber security of I&C systems presents a growing risk to nuclear facilities and requires the development of educational and research tools to ensure the safety of these facilities. Currently there is a major gap in formal educational offerings on cyber security for these Operational Technology (OT) systems. To provide formal cyber security education resources, DOE’s office of International Nuclear Security (INS) partnered with the University of São Paulo (USP) to develop a training course on the cyber security of nuclear facility I&C systems using the hypothetical Nuclear Power Plant, Asherah.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BCS (Beamline Control System) v2

The software is a flexible architecture used to integrate motors, analog data, digital signals, and instruments together to control scientific experiments and collect data during an experiment. The architecture supports features needed by scientists to quickly add new hardware to an experiment and to take and view data in a meaningful way. It does not perform analysis of the data, but provides basic visualization needed to evaluate the quality of the data as well as the calibration of the system.

Cornell, Earl↗

A qualitative assessment of current CCF guidance based on a review of safety system digital implementation changes with evolving technology - 148

This paper is a summary of a study performed in support of the US Nuclear Regulatory Commission (NRC) to evaluate current policy on software common-cause failure (CCF). The study reported in this paper is one of several that contributed to the technical basis to inform NRC staff. The study first reviewed policies and assessment guidance as discussed in the Staff Requirements Memorandum to the Secretary of the Commission, Office of the NRC (SECY) 93-087, Policy, Technical, and Licensing Issues Pertaining to Evolutionary and Advanced Light Water Reactor (ALWR) Designs, and Branch Technical Position (BTP) 7-19, Guidance on Evaluation of Defense-in-Depth and Diversity in Digital Computer-Based Instrumentation and Control Systems, as well as Chapter 7, 'Instrumentation and Controls', in NUREG-0800, Standard Review Plan for Review of Safety Analysis Reports for Nuclear Power Plants. The study then examined instrumentation and controls (I and C) technology implementations in nuclear power plants in the light of current CCF guidance. The intent was to assess whether the current position on CCF remains appropriate given the evolutions in digital safety system implementations and, if gaps in the guidance were found, to provide recommendations as to how these gaps could be closed. The methodology adopted was to review the vendors' technology and software implementation processes for digital safety systems as technology evolved. The following three representative safety systems were selected to provide illustrative examples: - Eagle 21 was selected to represent vintage microprocessor-based technology used from the 1980's to mid-1990's, - TELEPERM XS (TXS) was selected to represent second generation microprocessor-based technology used from the mid-1990's to the 2000's, and - The advanced logic system (ALS) was selected to represent the latest trend of using technology based on field programmable gate arrays (FPGAs). Technology implementations were reviewed in light of the basic premise of the NRC in BTP 7-19 (Revision 6), that software-based or software-logic-based digital system development errors are a credible source of CCF and therefore are susceptible to CCF because identical copies of the software-based logic and architecture are present in redundant divisions of safety-related systems. BTP 7-19 categorizes firmware and logic developed from software-based development systems all under software. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ensuring operator reliability in digital control rooms - 102

The U.S. fleet of nuclear power plants is aging, and efforts are being made to modernize instrumentation and control systems including integration of digital human-machine interfaces (HMIs) into the control room. Automation and control technologies have advanced since original systems were installed in the plants. This presents unique opportunities and challenges in ensuring the replacements are a benefit to the operators and the overall safe and reliable operation of the plant. We discuss trends we have observed from assisting utilities in their modernization efforts. Automation and evolving control rooms come with their own host of problems that existing human factors and engineering methods fail to capture. Traditional approaches are analytical approaches to ensuring reliability. Here we discuss some of the shortfalls of these traditional approaches as plants become increasingly more complex. We suggest that ensuring reliability for modernized and next generation control room will require expanding the scope of what was traditionally considered human factors as well as exploring novel approaches and methodologies for dealing with complexity and rapidly advancing technology. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Digital Infrastructure Migration Framework Report

This document presents a full-scope Digital Infrastructure implementation and associated lifecycle support recommendations that enable a plant life of 80+ years. Specific technologies and software applications are researched, developed, selected, implemented, and then integrated by utilities to enhance safety, reliability, and economic performance such that the result provides much more than the sum of its parts. Specific selection of these technologies is driven by business case analyses which are utility, station, and unit specific.

42 ENGINEERING↗

Test based reliability assessment method for a safety critical software in reactor protection system - 284

Digitalization of the instrumentation and control systems in nuclear power plant entails some new features which do not exist in analog systems. When the new features are applied in safety critical systems, the risk stemming from them should be quantified properly to assure the reliability of the entire power plant. Among the new features, software is considered as the most important factor because it can cause common cause failure to many redundant systems. Therefore, in this work, a test based reliability assessment method for a safety-critical software is developed. An output of a software is determined by not only inputs but also the internal state of the software at the time. In the case of safety critical software developed for usage in nuclear power plant, it is possible to directly investigate probable internal states thanks to detailed design specification and programing features, and the probable inputs also can be identified based on the physical linearity of each process parameter and hardware characteristics related to data acquisition. In this work, a development method for practical exhaustive test case consisting of investigation of internal state and probable input sets to a specific internal state are suggested. In addition to this, software logic simulator for execution of software logic test and the reliability quantification method based on the test result are developed. The feasibility of the suggested method is demonstrated via a case study. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mitsubishi experience on digital I and C and modernization

Digital systems are being applied to instrumentation and control (I and C) systems, including safety and non-safety systems, to accommodate obsolescence of existing analog devices or to obtain the benefits of digital I and C systems in new nuclear power plants as well as existing plants. This paper presents the Mitsubishi experience of digital I and C application and modernization. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The JET upgraded toroidal Alfvén Eigenmode Diagnostic System

The Alfvén Eigenmode Active Diagnostic system (AEAD) has undergone a major upgrade and redesign to provide a state-of-the-art excitation and real-time detection system for JET. The new system consists of individual 4 kW amplifiers allowing for increased current, separate excitation and real time control of relative phasing between antenna currents. The amplifiers have a frequency range of 10–1000 kHz, divided into various frequency bands by external matching filters. Due to the varying transmission line impedance throughout the frequency range, the amplifiers were designed with a very high resilience to reflected power. The existing amplifier control electronics have been replaced with a digital control system incorporating a National Instruments platform and Field Programmable Gate Array (FPGA) modules for frequency, gain and phase control with a frequency and phase resolution of less than 1 kHz and 1 degree respectively. Complementing the digital control system is the Protection and Control System, which utilizes Field Programmable Analog Arrays (FPAAs) and an array of electronic devices to monitor and control the AEAD. New capabilities such as independent antenna current/phase control, allow for improved excitation control, better definition of antenna spectrum combined with enhanced system reliability. This paper will review the new AEAD system, its unique capabilities and improvements over the previous diagnostic system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Future Vision for Instrumentation, Information and Control Modernization

A Future Vision of a transformed nuclear plant operating model based on an integrated digital environment has been developed as part of the Advanced Instrumentation, Information, and Control (II&C) research pathway, under the Light Water Reactor (LWR) Sustainability Program. This is a research and development program sponsored by the U.S. Department of Energy (DOE), performed in close collaboration with the nuclear utility industry, to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. II&C has been identified as a potential life-limiting issue for the domestic LWR fleet in addressing the reliability and aging concerns of the legacy systems in service today. The Future Vision is based on a digital architecture that encompasses all aspects of plant operations and support, integrating plant systems, plant work processes, and plant workers in a seamless digital environment to enhance nuclear safety, increase productivity, and improve overall plant performance. Pilot projects are being conducted as the means for industry to gain confidence in these new technologies for use in nuclear plant work activities. The pilot projects introduce new digital technologies into the nuclear plant operating environment at host operating plants to demonstrate and validate them for production usage. In turn, the pilot project technologies serve as the stepping stones to the eventual seamless digital environment as described in the Future Vision. Initial project results confirm that the technologies can address provide substantial efficiency and human performance benefits while resolving the reliability and aging concerns.

99 GENERAL AND MISCELLANEOUS↗

A Qualitative Assessment of Current CCF Guidance Based on a Review of Safety System Digital Implementation Changes with Evolving Technology

The US Nuclear Regulatory Commission (NRC) is initiating a new rulemaking project to develop a digital system common-cause failure (CCF) rule. This rulemaking will review and modify or affirm the NRC's current digital system CCF policy as discussed in the Staff Requirements Memorandum to the Secretary of the Commission, Office of the NRC (SECY) 93-087, Policy, Technical, and Licensing Issues Pertaining to Evolutionary and Advanced Light Water Reactor (ALWR) Designs, and Branch Technical Position (BTP) 7-19, Guidance on Evaluation of Defense-in-Depth and Diversity in Digital Computer-Based Instrumentation and Control Systems, as well as Chapter 7, Instrumentation and Controls, in NRC Regulatory Guide (NUREG)-0800, Standard Review Plan for Review of Safety Analysis Reports for Nuclear Power Plants (ML033580677). The Oak Ridge National Laboratory (ORNL) is providing technical support to the NRC staff on the CCF rulemaking, and this report is one of several providing the technical basis to inform NRC staff members. For the task described in this report, ORNL examined instrumentation and controls (I&C) technology implementations in nuclear power plants in the light of current CCF guidance. The intent was to assess whether the current position on CCF is adequate given the evolutions in digital safety system implementations and, if gaps in the guidance were found, to provide recommendations as to how these gaps could be closed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of quantitative methods for reliability testing of a nuclear power plant digital rod position indication diagnostic system - 391

Obsolescence, aging, reliability, and performance issues are driving nuclear facilities to replace conventional analog Instrumentation and Control (I and C) systems with digital technologies. In addition, the designs of the next generation of nuclear reactors, including Small Modular Reactors (SMRs), will incorporate digital I and C for most, if not all, of their safety and non-safety related functions. As part of an on-going research and development (R and D) effort under the auspices of the U.S. Department of Energy (DOE), Analysis and Measurement Services Corporation (AMS) is developing a platform to provide automated testing of digital I and C systems and create a standard method of evaluation for reliability assessments. This hands-on R and D effort has produced a Software Reliability Tester (SRT), which is a set of software and hardware tools designed to automate the testing of digital I and C systems to measure and quantify how well the systems perform under normal operating conditions and in the presence of faults. Furthermore, the SRT provides the foundation for a practical tool to automate verification and validation (V and V) activities and reduce the amount of testing time of digital I and C systems. When combined with its capabilities of integrating both reliability and fault tolerance quantification, the SRT can be used to ensure that digital I and C implementations are both safe and cost-effective for the nuclear industry. This paper describes the application of the SRT to perform V and V of a new Digital Rod Position Indication (DRPI) diagnostic system. The DRPI diagnostic system is a digital system that monitors the rod address and rod position data bus voltages of typical DRPI systems in nuclear power plants to detect and diagnose faults. For this application, the SRT was configured to exercise the inputs of the DRPI diagnostic system, and test cases were generated for common system faults such as address and data bit errors, bus voltage, and timing problems. These test cases were applied by the SRT hardware as voltage inputs to the DRPI diagnostic system and the outputs were compared to expected values generated by a model of the DRPI diagnostic system. Included in the paper is a description of the overall design of the SRT including the hardware and software architectures. Methodologies for automating test cases are also described. V and V using the SRT demonstrates the benefits of automated testing and qualification to provide a quantitative assessment of reliability and cost effective implementation of digital I and C in existing and next generation nuclear power plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Digital data acquisition and preliminary instrumentation study for the F-16 laminar flow control vehicle

Preliminary studies have shown that maintenance of laminar flow through active boundary-layer control is viable. Current research activity at NASA Langley and NASA Dryden is utilizing the F-16XL-1 research vehicle fitted with a laminar-flow suction glove that is connected to a vacuum manifold in order to create and control laminar flow at supersonic flight speeds. This experimental program has been designed to establish the feasibility of obtaining laminar flow at supersonic speeds with highly swept wing and to provide data for computational fluid dynamics (CFD) code calibration. Flight experiments conducted as supersonic speeds have indicated that it is possible to achieve laminar flow under controlled suction at flight Mach numbers greater than 1. Currently this glove is fitted with a series of pressure belts and flush mounted hot film sensors for the purpose of determining the pressure distributions and the extent of laminar flow region past the stagnation point. The present mode of data acquisition relies on out-dated on board multi-channel FM analogue tape recorder system. At the end of each flight, the analogue data is digitized through a long laborious process and then analyzed. It is proposed to replace this outdated system with an on board state-of-the-art digital data acquisition system capable of a through put rate of up to 1 MegaHertz. The purpose of this study was three-fold: (1) to develop a simple algorithm for acquiring data via 2 analogue-to-digital convertor boards simultaneously (total of 32 channels); (2) to interface hot-film/wire anemometry instrumentation with a PCAT type computer; and (3) to characterize the frequency response of a flush mounted film sensor. A brief description of each of the above tasks along with recommendations are given.

Ostowari, Cyrus↗

Investigation on experimental techniques to detect, locate and quantify gear noise in helicopter transmissions

A robotic system to automate the detection, location, and quantification of gear noise using acoustic intensity measurement techniques has been successfully developed. Major system components fabricated under this grant include an instrumentation robot arm, a robot digital control unit and system software. A commercial, desktop computer, spectrum analyzer and two microphone probe complete the equipment required for the Robotic Acoustic Intensity Measurement System (RAIMS). Large-scale acoustic studies of gear noise in helicopter transmissions cannot be performed accurately and reliably using presently available instrumentation and techniques. Operator safety is a major concern in certain gear noise studies due to the operating environment. The man-hours needed to document a noise field in situ is another shortcoming of present techniques. RAIMS was designed to reduce the labor and hazard in collecting data and to improve the accuracy and repeatability of characterizing the acoustic field by automating the measurement process. Using RAIMS a system operator can remotely control the instrumentation robot to scan surface areas and volumes generating acoustic intensity information using the two microphone technique. Acoustic intensity studies requiring hours of scan time can be performed automatically without operator assistance. During a scan sequence, the acoustic intensity probe is positioned by the robot and acoustic intensity data is collected, processed, and stored.

Flanagan, P. M.↗

Adaptive-Control Experiments On A Large Flexible Structure

Antennalike flexible structure built for research in advanced technology including suppression of vibrations and control of initial deflections. Structure instrumented with sensors and actuators connected to digital electronic control system, programmed with control algorithms to be tested. Particular attention in this research focused on direct model-reference adaptive-control algorithm based on command generator tracker theory. Built to exhibit multiple vibrational modes, low modal frequencies, and low structural damping. Made three-dimensional so complicated interactions among components of structure and control system investigated.

Ih, Che-Hang C.↗

Report on the "Symposium on Advancements in Simulating Neutron Scattering Instruments and Experiments"

An international group of researchers gathered for the “Symposium on Advancements in Simulating Neutron Scattering Instruments and Experiments” at Oak Ridge National Laboratory (ORNL) on October 29- 30, 2024. The symposium highlighted state-of-the-art advancements in neutron scattering instrument simulations and the development of digital twins for scattering instruments. This document summarizes the recurring themes from the 19 talks and discussions. A key focus was on the role of neutronics simulations in the design, analysis, and performance optimization of neutron instruments. Presentations featured the most widely used software packages, such as McStas, McVine, Vitess, and MCNP. Another major theme addressed the analysis and interpretation of experimental neutron data, where materials models and simulations play a critical role. Talks on relevant software tools, including NCrystal, OCLimax, and Paradyse, were delivered by their respective developers. During the symposium, both talks and breakout sessions explored strategies to enhance the interplay between neutronics simulations and materials models. A key question emerged: How can we develop a RealTime Explainable Digital Twin of a neutron scattering experiment? Discussions include the idea that the Digital Twin concept has implications for instrument control and testing. Through this symposium, we gained valuable insights into the challenges and requirements for developing a Real-Time Explainable Digital Twin of a neutron scattering experiment. The discussions and presentations paved the way for future innovations in this rapidly advancing field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of human machine interface (HMI) for digital control rooms in nuclear power plants - 119

The analog control systems of traditional Nuclear Power Plants (NPPs) are being replaced by digital systems due to the fact that analog Instrumentation and Control (I and C) systems are becoming obsolete and such technology is no longer supported by manufacturers. The purpose of this study is to jointly evaluate the performance of an operator with a Human Machine Interface (HMI) in a NPP digital control room ensuring the efficiency and the safety of the NPP. The validity and the accuracy of the operators' actions are the primary goals that have to be preserved through the emergence of the HMI based in digital systems. The transition from analog to digital control systems leads to a more advanced support of the NPP; Video Display Units (VDUs) are used for monitoring the state of the NPP while alarm systems help for directing attention. The operators, in order to monitor information from the different VDUs, have to switch attention between different screens (alarms systems and control systems). Therefore, a well-established HMI is a significant challenge to the overall operation of the NPP, that actually helps the operators to learn from the available information in detecting possible anomalies and making the right decisions, to ensure safety, and in parallel to diminish the human error. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reliability Assessment of Safety-Critical Network Communication in a Digitalized Nuclear Power Plant

In analog instrumentation and control (I and C) systems for nuclear power plants (NPPs), most connections are comprised of hardwired point-to-point types. Since they are based on analog technologies, they are fragile to noise and require analog-to-digital conversion time. Therefore, many NPPs have adopted communication network for the exchange of safety-critical data between programmable logic controllers (PLCs) in digital I and C systems to effectively accommodate a huge number of field controllers. However, the primary issue of digital network communication in a safety-critical system involves potential hazards, such as partial or total loss of communication between PLCs, which may result in a failure of safety critical signal generation when it is needed. Therefore, the probability that a safety-critical system in digitalized NPP becomes unsafe due to a network failure must be evaluated to quantify the risk of digital I and C system. In Korea, the Engineered Safety Feature-Component Control System (ESF-CCS) was developed as one of the digital safety-critical system in Advanced Power Reactor- 1400 (APR-1400). The function of a digital engineered safety feature (ESF) actuation system and field actuator controllers of conventional NPPs are performed by the ESF-CCS. In this system, safety-critical network, High Reliable- Safety Data Network (HR-SDN), was employed for the safety-critical data transmission from group controllers (GCs) to loop controllers (LCs). In this study, a framework for assessing the reliability of a HR-SDN network communication between GCs and LCs in the ESF-CCS in addition to a fault-tree model for ESF components considering network failure between GCs and LCs were developed to assess the plant risk effect of a newly developed digitalized ESF-CCS. Based on the case studies and cut set analysis, the risk effect of network failure on plant risk and the important risk contributors of network failure were quantitatively addressed. A framework for identifying the potential hazardous states of network communication in the ESFCCS was proposed. In addition, a fault-tree model for network communication failure was developed to estimate the risk effects of network failure between the GCs and LCs on ESF-CCS signal failure. The developed fault-tree model was then applied to several case studies. The fault-tree model of ESF-CCS signal failure for ESF components required for various mitigation actions regarding NPP DBAs was designed by considering the identified hazardous states of network failure that would result in a failure to provide input signals to the corresponding LC. As a sensitivity study, three case studies were performed based on the periodic test methods for hardware components in HR-SDN module and their test intervals in this study. The quantitative results for three case studies demonstrated that the probability of overall network communication failure, which was calculated as the sum of the failure probability associated with each failure cause, contributed up to 1.58% on the Small-LOCA CD frequency. The results also revealed the important basic events related to network failure in the case studies which included CCF of hardware and software in HR-SDN module. This study is expected to provide insight into the development of the fault-tree model for the network failure in digital I and C system and into the quantification of the risk effect of network failure for safety-critical data transmission in NPPs. As a further study, the risk effects of network failure in the ESF-CCS on the plant risk can be estimated in a more detailed manner by analyzing the failure modes and causes in a sub-component level and the fault detection coverage of the fault tolerance techniques for network failure implemented in ESF-CCS after the detailed configuration of ESF-CCS is decided. In terms of the failure of manual ESF actuation, the relationship among the human action failures must be investigated to consider multiple human error condition since ESF-CCS provides multiple manual actuation to assure the diversity of the system. Since the conventional HEP method cannot accommodate the multiple conditions in a fault tree, condition-based human reliability assessment (CBHRA) method or the dynamic human reliability modeling approach can be applied to include a complex relationship among the automated safety signal generation and the human operator's manual actuation, avoiding the optimistic estimation of HEP of the human action failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗