Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dispatchable Solar Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Techno-Economic Analysis of Greenfield Geothermal Hybrid Power Plants using a Solar or Natural Gas Steam Topping Cycle

The relatively low generation costs associated with wind, solar photovoltaic (PV), and natural-gas power plants make it challenging for geothermal power plants to produce and sell the power that has the reliability and sustainability characteristics that are greatly needed in U.S. power markets. This is especially true for geothermal resources with low-to-medium temperatures, which results in relatively low-thermal efficiency and generation costs that are higher than those for wind, solar PV, and natural gas. This analysis evaluates solar thermal- and natural-gas combustion waste heat recovery-based topping cycle hybridization of geothermal binary power plants. This approach provides several benefits that may allow geothermal power plants to generate power at more competitive costs. First, the addition of solar thermal energy or natural-gas combustion waste heat input to a geothermal power plant provides additional heat input that can be converted to electrical power. Second, the temperature level of the heat obtained from concentrating solar collectors or natural-gas combustion exhaust is higher than that of geothermal heat, which provides opportunities for improving the efficiency of the conversion of thermal energy to electrical power. Third, the ease with which solar thermal systems integrate with energy storage and the flexibility of natural gas means power generation can occur during peak demand periods. The hybrid cycles are compared to equivalently sized, co-located, independent geothermal, concentrating solar, and/or natural-gas power plants. The hybrid cycle tends to produce slightly more power than the standalone plants combined. However, the hybrid plant Levelized Cost of Energy (LCOE) is slightly higher than the LCOE of the combined standalone power plants for each of the case study locations investigated. Using the steam-topping cycle, organic Rankine cycle (ORC)-bottoming cycle hybrid plant design to combine a solar thermal resource and low- temperature geothermal resource (<120 degrees C) leads to a hybrid plant with a lower LCOE than a standalone geothermal-only system. Thus, hybrid plants may enable the economic development of geothermal resources in locations with low geothermal resource temperatures. However, in areas with higher geothermal resource temperatures (>120 degrees C), the geothermal-only plant has a lower LCOE than the hybrid cycle and thus could be developed without the need for solar heat addition. iv A geothermal-natural-gas reciprocating engine hybrid plant was evaluated for an Elk Hills, California case study location. The Elk Hills case study analysis indicates that when the natural-gas engine operates for more than 12 hours per day the hybrid plant can produce power at an LCOE lower than a standalone geothermal plant, and comparable to that of the standalone natural-gas reciprocating engine, while also reducing the carbon intensity of the power generated relative to the standalone natural-gas engine. This may represent a scenario in which the hybrid plant provides an opportunity for the deployment of a low-temperature geothermal resource that otherwise may have an LCOE too high to develop and operate as a standalone resource, while also reducing the carbon intensity of natural-gas generation sources. A "triple-hybrid" plant that combines natural gas, solar thermal, thermal energy storage, and geothermal was also investigated. A natural-gas combustion turbine (NGCT) is added to the geothermal-solar hybrid such that the hot exhaust gas from the gas turbine provides an alternative source of heat to the steam turbine of the hybrid cycle. Analysis results suggest that the triple-hybrid plant has a significantly higher energy generation and revenue than a standalone NGCT or the original geothermal-solar hybrid. The triple-hybrid design benefits most from using a smaller solar field so that the solar energy can be dispatched at the most valuable times available. The triple-hybrid plant also has a lower LCOE than the standalone NGCT. The triple-hybrid plant was evaluated making simple assumptions about the dispatch profile of the gas cycle, and more nuanced and realistic dispatching schedules should be analyzed in future work.

15 GEOTHERMAL ENERGY↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

NREL's Resource Planning Model

The Resource Planning Model (RPM) is a capacity expansion model designed for a regional power system, such as a utility service territory, state, or balancing authority. Designed from the ground up to include nodal detail, hourly chronological dispatch, and high spatial resolution for renewable resources, recent work has focused on inclusion of storage and other flexible technologies of interest for future power systems with more variable generation (e.g., wind and solar). This slide deck gives an overview of RPM modeling methods, provides example outputs, and briefly summarizes completed analysis projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Co-simulation Framework for Community-scale Building-grid Integration [SWR-21-75]

Distributed energy resources (DERs), including rooftop solar, energy storage, and flexible loads, are gaining popularity as costs decline and as building owners and utilities realize their benefits. DERs can improve distribution system efficiency, help prevent the need for expensive grid upgrades, and increase the resilience of local communities. However, they can also cause difficulties in grid operations and can require controls to achieve their benefits. To address this challenge, NREL researchers have developed a community-scale solution that assesses the impacts of DERs and their control strategies on a distribution system. The framework has been shown to reduce solar photovoltaic (PV) curtailment to 0%, mitigate the adverse impact of solar variability on the distribution voltage, and provide up to 5-day critical load support during emergency events. Utilizing 5 different modules representing the feeder, buildings, home energy management systems, an aggregator, and a utility controller, NREL expects this simulation technology to play a critical role in the continued integration of DERs. According to the Energy Information Administration (EIA), solar curtailments accounted for 94% of the total energy curtailed in the California Independent System Operator (CAISO) in 2020. By enabling Independent System Operators (ISOs) and utility operators to bring solar curtailments to 0%, the electrical grid can become less dependent on fossil-fueled power generation sources. NREL's co-simulation framework contains five major components: Distribution Feeder Model: describes the distribution feeder topology using OpenDSS, including the locations of all DERs. Residential Building Model: simulates a large number of buildings at a high resolution using OCHRETM. The model is equipped to control equipment based on signals from an external module. The model includes major household appliances such as HVAC and a water heater, non-dispatchable load models, a distributed PV system, and a home battery system. Home Energy Management System: optimizes the controls for the devices in a home using foreseeTM. The control can adjust based on the user preferences including cost, comfort, and convenience. In hierarchical control scenarios, where the houses follow signals from an aggregator, the home energy management system provides a flexibility band with a range of power and follows the dispatch signals received from aggregator. Community-Level Aggregator: solves for optimal energy dispatch based on the flexibility bands received from each home and the grid service signal received from the utility controller. Utility-Level Controller: provides grid signals for voltage control using Distributed Energy Resources (DERs), such as solar systems, in the community.

Balamurugan, Sivasathya Pradha↗

India 2030 Wind and Solar Integration Study (Interim Report)

India has established several targets for renewable energy capacity growth in the coming years, most notably the target of deploying 175 gigawatts (GW) of generation capacity from wind, solar, biomass, and small hydropower by 2022, and furthering that vision with India's Nationally Determined Contribution target of 40% renewable electricity capacity (including hydro) by 2030 (GOI 2015). Given the rapid and significant changes to India's power system to help meet these targets, the objective of this interim report is to understand the operational challenges for India's power grid in 2030. The primary contribution of this report is to establish a 2030 unit commitment and dispatch model of India's grid, with hourly temporal resolution, high spatial resolution of renewable energy resources, interstate transmission constraints, and unit-level generator characteristics. Annual simulations of 2030 operations demonstrate that a 22% annual penetration of wind and solar is manageable by India's grid. Most days in the year do not show signs of stress, and 99.97% of energy is served with the plans as presented. Average coal plant load factors are 70% for the year, up from relatively low plant load factors in recent years (Patel 2018). However, the results highlight specific challenges the grid may face during a small number of high-demand periods, resulting in unserved energy. The drivers behind the unserved energy suggest that this could be avoided with better coordination in scheduling. This report is part of a broader set of analyses under the Energy Transitions Commission (ETC), which includes collaborations with The Energy and Resources Institute (TERI), Climate Policy Initiative (CPI), and a broad stakeholder community.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Methodology for Quantifying Reliability Benefits From Improved Solar Power Forecasting in Multi-Timescale Power System Operations

Solar power forecasting improvements are mainly evaluated by statistical and economic metrics, and the practical reliability benefits of these forecasting enhancements have not yet been well quantified. This paper aims to quantify reliability benefits from solar power forecasting improvements. To systematically analyze the relationship between solar power forecasting improvements and reliability performance in power system operations, an expected synthetic reliability (ESR) metric is proposed to integrate state-of-the-art independent reliability metrics. The absolute value and standard deviation of area control errors (ACE), and the North American Electric Reliability Corporation Control Performance Standard 2 (CPS2) score are calculated through the multi-timescale scheduling simulation, including the day-ahead unit commitment (DU), real-time unit commitment (RU), real-time economic dispatch (RE), automatic generation control (AGC) sub-models. The absolute area control error in energy (AACEE), CPS2 violations, CPS2 score, and standard deviation of the raw ACE are all calculated and combined as the ESR metric. Numerical simulations show that the reliability benefits of multi-timescale power system operations are significantly increased due to the improved solar power forecasts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Scientific Technical Report for "Microgrid RD&D and Testing of PIDC and PWD Systems"

Alstom Grid Inc’s (ALSTOM Grid) Research Design and Development (RD&D) project, “Microgrid RD&D and Testing for PIDC and PWD” was conducted in partnership with Philadelphia Industrial Development Corporation (PIDC) in its role as owner’s representative and manager of a vibrant commercial and industrial community, involving critical loads in one of the nation’s largest unregulated, non-military electric distribution systems. PIDC needed to develop solutions to address the planned considerable growth in Distributed Energy Resources (DER) Combined Heat Plan (CHP), Renewables, Distributed Generation (DG), Demand Response (DR) and Storage. In supporting the corporate objective, PIDC needed a new class of control systems for achieving enhanced energy resilience of their critical infrastructure operation during adverse conditions together with carbon emission reduction and optimization of the overall system operation economics through system energy efficiency during normal and emergency operating conditions. Additionally, PIDC anticipated the need to support a new class of commercial agreements with tenants, such as those for Urban Outfitters, for guaranteed one hundred percent (100%) grid resilience and electric power supply in case of utility outage conditions. The project was designed to address the challenges for the commercial & industrial (C&I) communities. But more importantly, the project included development of scalable and replicable solutions intended to target a multitude of the nation’s electric distribution communities. The project researched and developed a fully comprehensive prototype consisting of microgrid operation and control functions including islanding, synchronization and reconnection, protection, voltage, frequency, and power quality management, dispatch, and system resiliency. The project provided the foundation required to significantly enhance the overall national objectives set by the DOE for energy resilience, emission reduction and system energy efficiency improvement, including protection of critical infrastructure and public resources.

14 SOLAR ENERGY↗

Integrated Thermal Energy Storage and Brayton Cycle Equipment Demonstration (Integrated TESTBED) Project Design Basis

The Integrated Thermal Energy Storage and Brayton cycle Equipment Demonstration (Integrated TESTBED) project seeks to retire commercial-scale risks associated with the design, integration,and operation of a supercritical carbon dioxide (sCO2) power cycle and concentrating solar power (CSP) thermal energy storage (TES) system. This requires an understanding of commercial-scale collector system transient impacts on the TES system, the dynamics of heat exchange from theTES to the power cycle, and the control and operation of the power cycle to accommodate various dispatch strategies. In order to retire these risks, Heliogen has proposed to construct a 5 MWe CSP demonstration facility based on directly heated particle and sCO2 technology. The receivers, primary heat exchanger, and power cycle will be deployed at a full commercial scale based on Heliogen’s modular plant architecture to ensure actual system integration risks are validated during design, construction, and operation. This work summarizes the design basis for the Integrated TESTBED project demonstration facility including a design target for capacity factor to support test operations, hours of storage, particle silo arrangement, centrifugal article receivers, a diffusion bonded particle-sCO2 heat exchanger, and a 5 MWe (net) integrally geared sCO2 recompression Brayton cycle.

14 SOLAR ENERGY↗

Exploring the design space of PV-plus-battery system configurations under evolving grid conditions

In this study, we explore how the energy and capacity values of coupled systems comprising solar photovoltaic arrays and battery storage (PV-plus-battery systems) could evolve over time based on the evolution of the bulk power system. Using a price-taker model with simulated hourly energy and capacity prices projected from the present to 2050, we simulate the revenue-maximizing dispatch of a range of DC-coupled PV-plus-battery configurations in three locations in the United States. These configurations are defined by the inverter loading ratio (ILR, the ratio of the PV array capacity to the inverter capacity, which we vary from 1.4 to 2.6) and the battery-inverter ratio (BIR, the ratio of the battery power capacity to the inverter capacity, which we vary from 0.25 to 1.0). Based on each configuration's total value, we estimate the breakeven costs needed to justify each incremental increase in ILR (holding BIR constant) or BIR (holding ILR constant). We find that, in a future with low-cost renewable energy technologies, PV-plus-battery system ILRs can be economically increased to around 2.0-2.4 at a BIR of 1.0, depending on solar resource. Our results indicate that a likely evolution of PV-plus-battery system design will be increasingly greater battery power capacity to mitigate the declining PV capacity value, which will, in turn, enable increasingly higher ILRs to further increase energy value. The extent to which PV-plus-systems will be deployed with increasingly higher ILRs depends primarily on whether PV cost declines outpace declining value and increasing curtailment over time.

14 SOLAR ENERGY↗

County-level assessment of behind-the-meter solar and storage to mitigate long duration power interruptions for residential customers

Customer concerns over electric system resilience could drive early adoption of behind-the-meter solar-plus-storage (BTM PVESS), especially as wildfire, hurricane, and other climate-driven risks to electric grids become more pronounced. However, the resilience benefits of BTM PVESS are poorly understood, especially for residential customers, owing to lack of data and methodological challenges, making it difficult to forecast adoption trends. In this paper, we develop a methodology to model the performance of BTM PVESS in providing backup power across a wide range of customer types, geography / climate conditions, and long duration power interruption scenarios, considering both whole-building backup and backup of specific critical loads. We combine novel, disaggregated end-use load profiles across the continental United States with temporally and geospatially aligned solar generation estimates. We then implement a PVESS dispatch algorithm to calculate the amount of load served during interruptions. We find that PVESS with 10 kWh of storage can meet a limited set of critical loads in most United States counties during any month of the year, though this capability drops to meeting only 86% of critical load, averaged across all counties and months, when heating and cooling are considered critical. Backup performance is lowest in winter months where electric heat is common (southeast and northwest U.S.) and in summer months in places with large cooling loads (southwest and southeast U.S.). Winter backup performance varies by roughly 20% depending on infiltration rates, while summer performance varies by close to 15% depending on the efficiency of the central air-conditioning system. Differences in temperature set-points in Harris County correspond to a 40% range in winter backup performance and a 20% range in summer performance. Economic calculations show that a customer’s resilience value of PVESS must be high to motivate adoption of these systems.

14 SOLAR ENERGY↗

Stochastic Models, Indices & Optimization Algorithms for Pricing & Hedging Reliability Risks in Modern Power Grids: Data Plan - Princeton

We collected and cleaned the synthetic grid data produced by NREL for the Texas and New York synthetic grids. We developed a high dimensional joint stochastic model for load at the zone level, and solar and wind power productions at the asset level, capturing the spatial and temporal dependencies between all the variables, and demonstrated how such a model could be fitted to historical data. We designed and implemented a simulation engine which can produce Monte Carlo scenarios for the hourly day-ahead values of load, and solar and wind power productions at the spatial and temporal resolutions of the historical data used to fit the model. Finally we developed an open-source Python package which can, from an input grid model, efficiently use forecasts and large numbers of Monte Carlo scenarios to provide unit commitment and economic dispatch for each of these scenarios. The high dimensional stochastic model and the subsequent Monte Carlo simulation engine were implemented in the package PGscen and the corresponding UC and ED optimization programs in the package Vatic.

14 SOLAR ENERGY↗

Separating Nuclear Reactors from the Power Block with Heat Storage: A New Power Plant Design Paradigm

The Massachusetts Institute of Technology (MIT), Idaho National Laboratory (INL) and the Electric Power Research Institute (EPRI) conducted a workshop on Separating Nuclear Reactors from the Power Block with Heat Storage: A New Power Plant Design Paradigm. The workshop was held as three webinars (July 29, August 12 and August 26, 2020). These proceedings include this abstract, an executive summary, the main report and presentations. There are two reasons to consider a new design paradigm. First, the market is changing with (1) the addition of variable wind and solar that results in highly volatile electricity prices and (2) the goal of a low-carbon economy that requires (a) economic dispatchable electricity that is now provided by natural gas turbines in the United States and (b) heat for industry and commerce. Second, nuclear plant requirements have changed in the last 50 years suggesting that a lower-cost plant layout may be to separate the nuclear island from the power block with a clear separation of the nuclear island with nuclear requirements and the power block built to industrial standards.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Decarbonization of the Electric Power Sector and Implications for Low-Cost Hydrogen Production from Water Electrolysis

Increasing development of wind and solar generation in the power sector can create economic opportunities for the deployment of water electrolyzers that produce hydrogen. Temporal variation in the marginal cost of energy in future decarbonized grids can make it favorable for electrolyzers to dispatchably ramp hydrogen production up and down in response to low- and high-cost times. Using this strategy, low-cost hydrogen production is enabled by electrolyzers that are low-capital cost and tolerant to frequent on/off cycling. Ramping down hydrogen production to a designated turndown ratio can avoid performance degradation caused by on/off cycling by not shutting the electrolyzer completely off. This comes with a slight cost penalty which can be minimized if the turndown ratio is low (i.e., the system ramps down hydrogen production to close to zero). These results suggest that electrolyzers integrated into future power systems are likely to benefit from the ability to ramp operation up and down quickly and operate in a standby mode. This analysis forms a basis for comparative tradeoffs between electrolyzer capital cost, operating strategy, and system durability and demonstrates the importance of considering all three factors in technoeconomic analysis.

capital cost↗

Optimal Complementarity Analysis of Potential Floating Solar Co-Located With Existing Hydropower Assets Across the Contiguous United States

The U.S. is expected to double its rate of renewable capacity from 2024 to 2030. However, the stochastic nature of renewable energy poses challenges to the operation and reliability of our power grid. The combined generation from renewable energy sources, with dispatchable sources (such as hydropower) operating as a hybrid energy plant, could mitigate this variability. In this paper, the complementarity analysis of selected U.S. reservoirs with existing hydropower assets (EHAs) and potential floating photovoltaics (FPVs) is conducted for the continuous U.S. (CONUS). The optimal FPV capacity for each site is determined by minimizing the variability of the combined output, while adhering to the FPV potential. Our results indicate that over 50% of the analyzed reservoirs achieve a stability coefficient exceeding 0.5, leading to a less-variable output after optimization. Finally, we analyze the complementary hydro-FPV hybrid reservoirs by considering both the Pearson correlation coefficient and the stability coefficient on daily, monthly, and yearly scales. Summaries are included of locations of theoretical FPVs co-located with hydropower plants that exhibit high complementarity based on the selected metrics.

13 - HYDRO ENERGY↗

Thermodynamically Stable, Plasmonic Transition Metal Oxide Nanoparticle Solar Selective Absorbers towards 95% Optical-to-Thermal Conversion Efficiency at 750 °C

Generation 3 (Gen) concentrating solar power (CSP) systems requires a high operation temperature ≥750°C to increase the power-cycle efficiency towards ≥50%. However, such a high operation temperature poses a notable challenge to high temperature materials. On the receiver side, a critical challenge is the lack of solar selective absorbers that demonstrate both high optical-to-thermal energy conversion efficiency η therm approaching 95% and long-term thermal stability at >750°C in air. Existing solar absorbers either have limited η therm ≤89% or deteriorate significantly within 500 h at 750°C; some of these also require costly vacuum deposition for stringent thickness control. Therefore, it is highly desirable to simultaneously achieve η therm ~95% AND high thermal stability at 750°C for future generations of CSP receivers. This project has investigated and developed low-cost, highly scalable spray-coated transition metal oxide nanoparticle (NP) pigmented solar selective coatings on various types of Inconel alloy tube sections that are thermodynamically stable at 750-800°C in air, maintaining η therm >94.3%(93.2%) under a solar concentration ratio of C=1000 after 60 simulated day-night cycles at 750ºC (800ºC) (1 cycle=12 h at 750 or 800°C and 12h ramping down to 25°C). We have also coated up to 48 inches long receiver tubes for preliminary solar testing under Norwich Technology’s parabolic trough systems, demonstrating notably improved performance in solar heating compared to benchmark Pyromark 2500 coatings. Two key innovations have been developed in this project: (1) We achieved an unprecedented high thermal efficiency >94% by optimizing the d-band optical absorption spectra of transition metal ions, engineering their valences and stoichiometry; (2) We were able to maintain or even slightly increase the efficiency when operating at 750°C in air by engineering the interdiffusion of transition metal ions between the coating and the Inconel substrate to our advantage. Featuring high-temperature solar spectral selectivity and thermodynamic stability in air, as well as low-cost, highly scalable solution-chemical synthesis and spray coating techniques, this innovation in solar selective absorber technology alone accounts for nearly 40% of the targeted reduction in the levelized cost of electricity (LCOE) from the receiver, thermal energy storage, and operation & maintenance combined by 2030, as proposed by the U.S. Department of Energy. For a 110 MWe CSP power plant, this LCOE reduction from the solar selective coating alone transfers to ~$\$ $1.9 M increase in annual profit based on a sales price of 10¢/kWh (or an annual sale of $50 M/year). The high solar absorptance (~98%) NP pigment materials developed in this project are equally applicable to volumetric receivers either as a coating or as bigger ceramic microspheres after sintering, potentially benefiting Gen3 falling particle CSP technologies. All these contributions facilitate the larger scale deployment of CSP systems with energy storage capability to address the intermittency issue of solar energy towards dispatchable solar electricity, bridging the temporal gap between peak solar electricity production and peak electricity consumption. The collaboration with Norwich Technologies and Brayton Energy in this project will also facilitate the future commercialization of this new solar selective coating technology developed in this SIPS project.

14 SOLAR ENERGY↗

Heat Storage Coupled to Generation IV Reactors for Variable Electricity from Base-load Reactors: Workshop Proceedings. Changing markets, technology, nuclear-renewables integration and synergisms with solar thermal power systems

Electricity markets are changing because of (1) the addition of wind and solar that creates volatile electricity prices including times of zero-priced electricity and (2) the goal of a low-carbon world that requires replacing fossil fuels that provide (a) energy, (b) stored energy, and (c) dispatchable energy. Wind and solar provide energy but not the other two other energy functions that are provided fossil fuels. Nuclear energy with heat storage can provide all three functions and thus replace fossil fuels.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗