Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distribution Grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Harnessing distributed GPU computing for generalizable graph convolutional networks in power grid reliability assessments

Although machine learning (ML) has emerged as a powerful tool for rapidly assessing grid contingencies, prior studies have largely considered a static grid topology in their analyses. This limits their application, since they need to be re-trained for every new topology. Here, this paper explores the development of generalizable graph convolutional network (GCN) models by pre-training them across a range of grid topologies and contingency types. We found that a GCN model with auto-regressive moving average (ARMA) layers with a line graph representation of the grid offered the best predictive performance in predicting voltage magnitudes (VM) and voltage angles (VA). We introduced the concept of phantom nodes to consider disparate grid topologies with a varying number of nodes and lines. For pre-training the GCN ARMA model across a variety of topologies, distributed graphics processing unit (GPU) computing afforded us significant training scalability. The predictive performance of this model on grid topologies that were part of the training data is substantially better than the direct current (DC) approximation. Although direct application of the pre-trained model to topologies that are not part of the grid is not particularly satisfactory, fine-tuning with small amounts of data from a specific topology of interest significantly improves predictive performance. In general, this paper highlights the feasibility of training large-scale GNN models to assess the reliability of power grids by considering a wide variety of grid topologies and contingency types. With the advent of foundational models in ML and the exponential increase in GPU computing clusters, generalizable ML models will significantly enhance how utilities manage power systems and make decisions in real-time or near-real-time.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Unlocking load growth at the grid edge: Practices for managing, recovering, and allocating distribution system investments

Utilities and utility regulators are preparing to make significant investments in the electricity distribution system driven by expected load growth in coming years and decades. Regulators will be tasked with vetting investment proposals and implementing cost recovery and allocation mechanisms. In particular, state regulators are anticipating the need to make proactive distribution system investments, building the capability to serve new load in advance of demand. This report focuses on load growth from homes and businesses that adopt electric vehicles and heat pump heating technologies. Through a review of legislation and regulatory dockets in a subset of states, we provide insights into emerging utility and regulatory practices to recover and allocate costs of electrification-driven distribution system investments necessary to accommodate these technologies. Our review focused on utility electrification programs, line extension policies, and proactive investments. Our report is largely descriptive, offering detailed information about approaches different state commissions and utilities have implemented to inform future decision-making.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A moment-conserving discontinuous Galerkin representation of the relativistic Maxwellian distribution

Kinetic simulations of relativistic gases and plasmas are critical for understanding diverse astrophysical and terrestrial systems, but the accurate construction of the relativistic Maxwellian, the Maxwell–Jüttner distribution, on a discrete simulation grid is challenging. Difficulties arise from the finite velocity bounds of the domain, which may not capture the entire distribution function, as well as errors introduced by projecting the function onto a discrete grid. Here, we present a novel scheme for iteratively correcting the moments of the projected distribution applicable to all grid-based discretizations of the relativistic kinetic equation. In addition, we describe how to compute the needed nonlinear quantities, such as Lorentz boost factors, in a discontinuous Galerkin scheme through a combination of numerical quadrature and weak operations. The resulting method accurately captures the distribution function and ensures that the moments match the desired values to machine precision.

astrophysical plasmas↗

Plug-in Electric Vehicle Charging Response Characterization for Grid Integration: Implications for Smart Charge Management

The rapid expansion of plug-in electric vehicles (PEVs) has created a unique challenge for electrical grids due to their significant power demand. At the same time, PEVs also create a unique opportunity to ease their own burden on the power grid, as they create a growing fleet of distributed energy resources capable of providing grid services such as demand response, frequency regulation, and renewable balancing. For aggregators and grid operators to effectively integrate PEVs into grid management, it is essential to first understand and characterize how they would respond in such situations. This study examines 25 models of PEVs across 25 makes, spanning model years from 2013 to 2025, to characterize their responses to the basic controls used in vehicle-grid integration (VGI): stopping, starting, and modulating the charge rate. Each vehicle was tested in a controlled laboratory setting to evaluate its performance in response to varying the maximum allowable current via the SAE J1772 control pilot signal, as well as its response to wake-up commands outlined in SAE J1772. Results show measurable differences across vehicle makes in the accuracy, latency, and precision with which PEVs respond to changes in ampacity, as well as varying sleep and wake-up behavior. The test results show that all vehicles respond to changes in ampacity, though with varying accuracy, precision, latency, and resolution. Wake-up behavior also differs across makes and models. These findings indicate that effective grid integration strategies must account for these differences. The results provide a foundation for understanding current vehicle behavior and advancing smart-charging methods while also highlighting the need for further testing, broader standardization, and manufacturer collaboration to ensure the successful integration of PEVs into the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Impact of High-Order Harmonic Generation in Electrical Distribution Systems

The modern power grid has seen a rise in the integration of non-linear loads, presenting a significant concern for operators. These loads introduce unwanted harmonics, leading to potential issues such as overheating and improper functioning of circuit breakers. In pursuing a more sustainable grid, the adoption of electric vehicles (EVs) and photovoltaic (PV) systems in residential networks has increased. Understanding and examining the effects of high-order harmonic frequencies beyond $1.5$ kHz is crucial to understanding their impact on the operation and planning of electrical distribution systems under varying nonlinear loading conditions. This study investigates a diverse set of critical power electronic loads within a household modeled using PSCAD/EMTdc, analyzing their unique harmonic spectra. This information is utilized to run the time-series harmonic analysis program in OpenDSS on a modified IEEE 34 bus test system model. The impact of high-order harmonics is quantified using metrics that evaluate total harmonic distortion (THD), transformer harmonic-driven eddy current loss component, and propagation of harmonics from the source to the substation transformer.

Peerzada, Aaqib A. [BATTELLE (PACIFIC NW LAB)]↗

Enabling DER visibility using a distributed dissemination network

The electrical grid is currently undergoing a series of rapid transformational changes that have resulted in the introduction of new actors and operational schemes that have fragmented the data and control planes. To help address the issue, this paper describes the implementation of a sensor-oriented, distributed data dissemination network that seeks to eliminate data silos. The implementation is based on the DGSS architecture previously described in [1]. The developed product seeks to facilitate the seamless integration of multi-operator, multi-origin, multi-domain sensor data by using a distributed systems approach. The proposed solution decouples the sensor’s data streams from the application-specific infrastructure and migrates them into a software-defined databus that can be configured to suit the end application’s demands. To further validate DGSS capabilities, a DER oriented use case has been developed.

Sensor Dissemination Networks, Enhanced DER visibi↗

Transmission and Distribution Coordination

This webinar explores planning the future grid and interconnected energy system while examining balancing generation (G), transmission (T), distribution (D), & customer (C) resources all while also increasingly capturing engineering details in planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Regional Inertia Estimation Using Actual Event Measurements: Florida Case

As inverter-based resources’ integration in power grids increases, their uneven distribution across the electrical network leads to the formation of local regions that are weakly coupled to the larger interconnection. This signifies the necessity of regional frequency dynamics investigation and analyzing various inertia metrics. This paper presents a practical methodology for estimating regional rate-of-change of frequency (RoCoF) using actual event recordings, which is then used to evaluate regional inertia. Florida (FL) is selected as the region of interest due to its distinct regional frequency dynamics and the rising levels of solar generation. We identify and analyze confirmed events from 2017 to 2024 that occurred in FL. The results indicate that FL contributes about 14% to the total inertia of the US Eastern Interconnection, which approximately matches its share of generation capacity. Results also highlight seasonal fluctuations in energy generation, which play a significant role in influencing inertia and thus the RoCoF levels. This emphasizes the importance of estimating regional inertia to enhance grid operations for a future that focuses on distributed generation.

Dulal, Saurav [University of Tennessee, Knoxville ↗

Defining a Platform Approach and Market Participation: Data Driven Business Models for Solid State Transformer-Based Synthetic Inertia and Voltage Stability Controls (CRADA Final Report, Project 1, Mod 1)

The primary objective of this project is to determine the incremental value created with the medium voltage solid-state transformer (MV SST) technology to different stakeholders in view of the updated DER grid regulations. This includes studying the benefits of the MV SST technology in a range of use cases for EV and DER penetration including (1) “corridor charging” for EVs and (2) solar plus storage (FERC 2222). The potential customers of this technology include utilities for EV charging, DER installers who must meet utility interconnection requirements, balancing authorities, and DER aggregators. The traditional transformers on the grid could be a limiting factor for the EV-grid integration as the distribution transformers were not designed to handle the dynamic and fluctuating EV charging loads. Thus, the issues such as voltage fluctuations, increased losses and reduced efficiency [1] can negatively impact the grid operation. To address these challenges, transformers with flexibility and adaptability become imperative to meet the evolving energy demands. In this regard, the concept of Medium Voltage Solid-State Transformers.

14 SOLAR ENERGY↗

Work With Us to Advance Cybersecurity for the Current and Future Grid

The energy sector is undergoing rapid change. Advanced technologies and controls, digitally connected devices, and a mix of generation sources offer increased energy reliability and security, reduced energy costs, and enhanced grid operations. But they can also carry physical and cybersecurity risks that are not yet fully understood. With deep expertise in advanced energy technologies, the National Laboratory of the Rockies is examining the cybersecurity implications of evolving systems and developing cutting-edge tools, novel approaches, and innovative research capabilities to address sector-wide challenges. Together with our partners, we are working to achieve a more secure, defensible, and reliable grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Visibility-enhanced model-free deep reinforcement learning algorithm for voltage control in realistic distribution systems using smart inverters

Increasing integration of distributed solar photovoltaic (PV) into distribution networks could result in adverse effects on grid operation. Traditional model-based control algorithms require accurate model information that is difficult to acquire and thus are challenging to implement in practice. Here, this paper proposes a surrogate model-enabled grid visibility scheme to empower deep reinforcement learning (DRL) approach for distribution network voltage regulation using PV inverters with minimal system knowledge. In contrast to existing DRL methods, this paper presents and corroborates the adverse impact of missing load information on DRL performance and, based on this finding, proposes a surrogate model methodology to impute load information utilizing observable data. Additionally, a multi-fidelity neural network is utilized to construct the DRL training environment, chosen for its efficient data utilization and enhanced robustness to data uncertainty. The feasibility and effectiveness of the proposed algorithm are assessed by considering DRL testing across varying degrees of observable load information and diverse training environments on a realistic power system.

14 SOLAR ENERGY↗

Economic Evaluation of Modernization Expenditures for Electric Utility Distribution Systems: A Guide for Utility Regulators

Cost-effectiveness evaluation of potential grid modernization solutions is integral to integrated distribution system planning (IDSP). This report synthesizes and updates prior cost-effectiveness approaches identified by the U.S. Department of Energy for grid modernization investments, incorporating multi-objective decision-making. The structure of the report follows the IDSP process, from identifying objectives and priorities to prioritizing grid solutions. The report details two methods for conducting initial cost-effectiveness screening of individual and interdependent grid components: (1) Lowest Reasonable Cost and (2) Benefit-Cost Analysis. Drawing on solutions that passed the initial cost-effectiveness screen, the utility prioritizes grid solutions based on policy objectives and priorities, regulatory compliance, operational efficiencies, and other factors to develop a portfolio of distribution solutions. The utility uses multi-objective decision-making to assess each proposed expenditure against each objective and respective metric. The utility applies a weighting factor, reflecting the priority ranking of the objective, to the total numerical “score” based on the contribution of the proposed solution to addressing each objective. Ultimately, the utility ranks each expenditure from highest to lowest priority using the final score for each solution as well as its cost. The report includes examples of emerging best practices for states and utilities and a cost-effectiveness process checklist.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Electric Vehicle Charging and Discharging Strategies Under DER Compensation Programs: Preprint

The adoption of electric vehicles (EVs) is becoming increasingly popular because of environmental concerns, the greater availability of models, and increased cost-competitiveness with gas vehicles. Because EVs have both charging and discharging capabilities, they provide great potential to help electric utilities with grid operation. When the grid demand is high, EVs can discharge to the grid to reduce the peak load, and vice versa; therefore, electric utilities have designed different policies to encourage EV charging station operators to charge or discharge at certain time periods. The New York State Public Service Commission established the Value of Distributed Energy Resources (VDER), or the Value Stack, to compensate for energy created by distributed energy resources, including EVs. This paper presents an optimization-based approach to identify the "golden hours" and "golden spots," i.e., the effective time periods and geographic locations for EV charging station operators to charge or discharge under the VDER program that can provide them the highest benefit. The proposed methodology can be applied to other compensation mechanisms and distribution systems as well. By working with industry partner NineDot Energy, realistic charging station information is used in this study, and the proposed approach is tested on a distribution feeder. The results from this study can help electric utilities and EV charging station operators determine the ideal charging/discharging time and the ideal locations for the charging station(s) in their distribution systems to achieve maximized benefit.

electric vehicle↗

Autonomous Grid Support Functionality in Variable-Speed Drive-Based End-Use Loads

High penetration of inverter-based resources into power systems causes lower inertia, and it becomes more challenging to maintain grid stability during contingency events. While conventional demand response and shedding at the load side suffer from slow response, impact by unavailability, and issues from communication, variable-speed drives (VSDs) are becoming strong candidates for fast frequency response (FFR) thanks to their fast response and reduced user impact from variable power adjustment capability. In this letter, we propose an autonomous frequency support control method for a residential refrigerator with a VSD, a promising target small end-use load for FFR. We analyze the effect of the proposed controller on grid stability, and we verify the performance through laboratory experiments with a commercially available refrigerator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability Analysis of Power Systems with High Penetration of State-of-the-Art Inverter Technologies

With the increasing level of inverter-based resources (IBRs) in modern power systems, this paper presents a small-signal stability analysis for power systems comprising synchronous generators (SGs) and IBRs. Four types of inverter controls are considered: two grid-following (GFL) controls, with or without grid support functions; droop-based grid-forming (GFM) controls; and virtual oscillator control-based GFM. We also analyze the impact of STATCOM and synchronous condensers on system stability to assess their role in the energy mix transition. With the small-signal dynamic behavior of the major technologies modeled, this paper provides stringent stability assessments using the IEEE 39-bus benchmark system modified to simulate future power systems. The exhaustive test cases allow for (a) assessing the impacts of different types and controls of generation and supplementary grid assets, as well as system inertia and line impedance on grid stability, and (b) elucidating pathways for the stabilization of IBR-dominated power systems. The analysis also indicates that future power systems can be stabilized with only a fraction of the total generation as voltage sources without SGs or significant system inertia if they are well distributed. This study provides insights into future power system operations with a high level of IBRs that can also be used for planning and operation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Vertical Federated Machine Learning Against Adversarial Threats on Wide-Area Control System: Preprint

Federated machine learning (FL) is gaining significant popularity to develop cybersecurity solutions in power grids because of its advanced capability to support decentralized data handing at local devices, its privacy preservation, and its low-bandwidth requirement. However, the evolving adversarial machine learning (AML) threats raise significant concerns for the cybersecurity of FL architectures. The FL-based split neural network (SplitNN) achieves high performance through the decentralized training of local neural network models while preserving data privacy across multiple entities. In this paper, we propose a methodology for evaluating the performance of a vertical FLbased anomaly detector against different types of AML attacks, including denial-of-service attacks, adversarial data injection attacks, and replay attacks on the trained local models deployed in the grid network. For a case study, we consider the modified IEEE 13-bus system, and we develop SplitNN-based binary and multiclass classification models to detect, locate, and identify different types of data integrity attacks on the volt-watt control with two pooling layers: maximum pooling and AvgPool. Our experimental results, computed through performance metrics, reveal that the severity of these AML attacks varies with the integrated pooling mechanism, the type of classification model, and the nature of the cyberattack. Further, the AML attacks negatively impacted the prediction time per sample for the pretrained SplitNN during the online testing.

adversarial threats↗