Search NASA⌕ Search

SEARCH · Search NASA

Results for “Doppler spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Some aspects of remote atmospheric sensing by laser radar

An analysis has been made of some aspects of atmospheric sensing by laser radar spectroscopy. A discussion of the laser radar equation is presented which leads to methods for obtaining atmospheric information by spectroscopic means. Calculations are presented which investigate the potential of Doppler, Raman and differential absorption techniques. It is concluded that atmospheric measurements based upon Doppler and Raman approaches are restricted to qualitative studies at the present time primarily because of the limitations imposed by existing laser sources and detectors. It is probable that these limitations will be removed in the near future and it is recommended that exploratory experiments be continued. The differential absorption method for obtaining the spatial distribution of atmospheric gases is well developed for such gases as water vapor and oxygen where the basic laser frequency lies close to the center of the particular absorption line. Further investigation is recommended in the field of laser frequency shifting. Additional information is also required on the shape of the absorption line, particular in the region where the line reflects both pressure and Doppler broadening.

Schotland, R. M.↗

Tunable semiconductor laser with two acousto-optic tunable filters in its external cavity

We report a laser with a linear external cavity containing a near-IR injection semiconductor optical amplifier as a gain element and two acousto-optic tunable filters (AOTFs) with quasi-collinear interaction of acoustic and light waves. At identical frequencies of RF signals that control the filters and ensure compensation for the Doppler frequency shift of light passing through the AOTFs, the steady-state laser emission linewidth can be reduced to about 25 MHz, which is almost three orders of magnitude smaller than that in the case of one filter (20 GHz). The position of the emission line, which remains narrow, slowly fluctuates within a spectral range about 3 GHz wide, which seems to be due to the large length of the external cavity and insufficient thermal stabilization of its components. This does not prevent us from obtaining light with a large coherence length. In emission wavelength sweep mode, the instantaneous emission linewidth increases with tuning rate, reaching 0.022 nm (8.8 GHz) at the highest tuning rate: 10{sup 4} nm s{sup −1}. In the case of automatic control over the output optical power at a level of 3 mW, the tuning range is 815 – 875 nm. Such instruments are of practical interest for optical coherence tomography, spectroscopy, optical metrology, and other application areas. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

The convective noise floor for the spectroscopic detection of low mass companions to solar type stars

The threshold mass for the unambiguous spectroscopic detection of low mass companions to solar type stars is defined here as the time when the maximum acceleration in the stellar radial velocity due to the Doppler reflex of the companion exceeds the apparent acceleration produced by changes in convection. An apparent acceleration of 11 m/s/yr in integrated sunlight was measured using near infrared Fourier transform spectroscopy. This drift in the apparent solar velocity is attributed to a lessening in the magnetic inhibition of granular convection as solar minimum approaches. The threshold mass for spectroscopic detection of companions to a one solar mass star is estimated at below one Jupiter mass.

Deming, D.↗

Diode laser saturation spectroscopy of NH3

Saturation of molecular transitions using a tuneable diode laser was demonstrated for the first time using a standing-wave cavity configuration with an f/8 beam focussed at the sample. Observed saturation effects in NH3 transitions near 888/cm include sub-Doppler (Lamb-dip) resonances at line center.

Jennings, D. E.↗

Re-evaluation of ortho-para- dependence of self pressure-broadening in the ν 1 + ν 3 band of acetylene

Optical frequency comb-referenced measurements of self pressure-broadened line profiles of the R(8) to R(13) lines in the ν 1 + ν 3 combination band of acetylene near 1.52 µ m are reported. The analysis of the data found no evidence for a previously reported systematic alternation in self pressure-broadened line widths with the nuclear spin state of the molecule. This work brought out the need for the use of an accurate line profile model and careful accounting for weak background absorptions due to hot band and lower abundance isotopomer lines. The data were adequately fit using the quadratic speed-dependent Voigt profile model, neglecting the small speed-dependent shift. Parameters describing the most probable and speed-dependent pressure-broadening, most probable shift, and the line strength were determined for each line. Detailed modeling of the results of Iwakuni et al. showed that their neglect of collisional narrowing due to the speed-dependent broadening term combined with the strongly absorbing data recorded and analyzed in transmission mode were the reasons for their results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Differential absorption lidar measurements of atmospheric water vapor using a pseudonoise code modulated AlGaAs laser

Lidar measurements using pseudonoise code modulated AlGaAs lasers are reported. Horizontal path lidar measurements were made at night to terrestrial targets at ranges of 5 and 13 km with 35 mW of average power and integration times of one second. Cloud and aerosol lidar measurements were made to thin cirrus clouds at 13 km altitude with Rayleigh (molecular) backscatter evident up to 9 km. Average transmitter power was 35 mW and measurement integration time was 20 minutes. An AlGaAs laser was used to characterize spectral properties of water vapor absorption lines at 811.617, 816.024, and 815.769 nm in a multipass absorption cell using derivative spectroscopy techniques. Frequency locking of an AlGaAs laser to a water vapor absorption line was achieved with a laser center frequency stability measured to better than one-fifth of the water vapor Doppler linewidth over several minutes. Differential absorption lidar measurements of atmospheric water vapor were made in both integrated path and range-resolved modes using an externally modulated AlGaAs laser. Mean water vapor number density was estimated from both integrated path and range-resolved DIAL measurements and agreed with measured humidity values to within 6.5 percent and 20 percent, respectively. Error sources were identified and their effects on estimates of water vapor number density calculated.

Rall, Jonathan A. R.↗

Indium Single-Ion Frequency Standard

A single laser-cooled indium ion is a promising candidate for an ultimate resolution optical time or frequency standard. It can be shown that single ions from group IIIA of the periodic table (indium, thallium, etc.) can have extremely small systematic errors. In addition to being free from Doppler, transit-time and collisional shifts, these ions are also quite insensitive to perturbations from ambient magnetic and electric fields (mainly due to the use of a J=0-0 transition for spectroscopy). Of all group IIIA ions, indium seems to be the most practical, since it is heavy enough to have a tolerable intercombination cooling transition rate and (unlike thallium) has transitions which are easily accessible with frequency multiplied continuous-wave lasers. A single indium ion standard has a potential inaccuracy of one part in 10(exp 18) for integration times of 10(exp 6) seconds. We have made substantial progress during the grant period in constructing a frequency standard based upon a single indium ion. At the beginning of the grant period, single indium ions were being successfully trapped, but the lasers and optical systems were inadequate to achieve the desired goal. We have considerably improved the stability of the dye laser used to cool the ions and locked it to a molecular resonance line, making it possible to observe stable cooling-line fluorescence from a single indium ion for reasonable periods of time, as required by the demands of precision spectroscopy. We have substantially improved the single-ion fluorescence signal with significant benefits for the detection efficiency of forbidden transitions using the 'shelving' technique. Finally, we have constructed a compact, efficient UV 'clock' laser and observed 'clock' transitions in single indium ions using this laser system. We will elaborate on these accomplishments.

Nagourney, Warren↗

Tunable diode laser optogalvanic spectroscopy of molecules

The laser optogalvanic (LOG) technique for studying molecular spectra has been extended for the first time to the infrared wavelength region. Portions of the NH3 nu-2 band at 9.5 microns and the NO2 nu-3 band at 6.2 microns have been recorded at Doppler-limited resolution using CW tunable diode lasers to probe dc electrical discharges in pure NH3 and an NO2/He gas mixture. Using adjustable electrode positions and an orthogonal geometry between the probe laser and the discharge axis, two contributions to the optogalvanic signal are identified: one which corresponds to an increase in discharge impedance and is seen only for irradiation of the negative glow region; and a second which corresponds to a decrease in discharge impedance and is seen for irradiation of all other discharge regions.

Webster, C. R.↗

An Intense Slit Discharge Source of Jet-Cooled Molecular Ions and Radicals (T(sub rot) less than 30 K)

A novel pulsed, slit supersonic discharge source is described for generating intense jet-cooled densities of radicals (greater than 10(exp 12)/cu cm) and molecular ions (greater than 10(exp 10)/cu cm) under long absorption path (80 cm), supersonically cooled conditions. The design confines the discharge region upstream of the supersonic expansion orifice to achieve efficient rotational cooling down to 30 K or less. The collisionally collimated velocity distribution in the slit discharge geometry yields sub-Doppler spectral linewidths, which for open-shell radicals reveals spin-rotation splittings and broadening due to nuclear hyperfine structure. Application of the slit source for high-resolution, direct IR laser absorption spectroscopy in discharges is demonstrated on species such as OH, H3O(+) and N2H(+).

Anderson, David T.↗

Identification of Auger mechanisms responsible for low energy electron emission from graphene on copper using Auger-gamma coincidence spectroscopy

We have applied positron annihilation induced Auger-gamma coincidence spectroscopy to identify important mechanisms responsible for the emission of low energy electrons following the sudden creation of holes in bilayer graphene on copper substrate. The novel surface spectroscopic method measures the energy of the Doppler shifted annihilation gamma photon in coincidence with the Auger electron emitted following the relaxation of the hole created by the annihilation of a surface electron with a surface trapped positron. By extracting and theoretically modelling the annihilation gamma spectra coincident with low energy electrons, we associate majority of the intensity in the low energy (7 eV–25 eV) region of the Auger spectrum to electron emission following Auger decays of 2s holes in adsorbed oxygen and deep valence holes in graphene. We provide additional support to this conclusion by showing that most of the Auger electrons with energy less than ~ 25 eV are coincident with gamma photons with small Doppler shift (511 keV–512 keV) indicating that the primary electron whose annihilation resulted in low energy Auger electron emission had small momentum parallel to the gamma emission direction. On the other hand, majority of the Auger electrons measured in coincidence with the photons having maximum Doppler shift (515 keV–521 keV) were emitted following the decay of core holes (C 1s and O 1s). Furthermore, by selecting annihilation gamma photons coincident only with the O KVV (from surface adsorbed oxygen), C KVV (graphene), and Cu MVV (copper substrate) Auger electrons, we have also experimentally derived the energy spectrum of Doppler shifted gamma photons resulting from the annihilation of positrons with 1s electrons of O, 1s electrons of C and 3p electrons of Cu respectively. Model Doppler broadened gamma spectra produced using ab-initio calculations agree well with the experimentally derived line shapes. This demonstrates the ability of Auger-gamma coincidence method to experimentally resolve the Doppler broadened annihilation gamma spectrum from surfaces into its veiled electronic level constituents which has, heretofore, relied solely on theoretical analysis. Our results also demonstrate that the line shape of the Doppler broadened annihilation gamma peak reflect the chemical composition of the topmost atomic layer and can thus be used to characterize both external and inaccessible surfaces of porous materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray line widths and coronal heating

Preliminary results of spectroscopy and imaging of a solar active region and flare plasma in soft X-ray emission lines are presented. Observed X-ray line widths in a nonflaring active region are broader than the Doppler width corresponding to the local electron temperature. An analysis of 41 soft X-ray flares within a single active region reveals a preference for flares to occur at locations that already show enhanced X-ray emission and to favor magnetic complexity over high gradient. However, flares do not appear to be directly responsible for the heating and X-ray production of the active regions.

Acton, L. W.↗

Stable isotope laser spectroscopy

Recent advances in semiconductor laser technology have produced a reliable lightweight device ideally suited for a spacecraft high resolution molecular spectrometer. Lead-salt tunable diode lasers (TDL) emit in several spectral modes, each with a very narrow linewidth of -0.0003/cm. This spectral resolution is much narrower than typical Doppler broadened molecular linewidths in the mid-IR range. Thus it is possible to detect individual rotational lines within the vibrational band and measure their intensity, which can be used to determine gas concentration. The narrow spectral lines of any impurity gas tend to lie between the narrow lines of the gas of interest. This represents a major advantage over the accepted gas chromatograph mass spectrometer (GCMS) technique for measuring gas concentrations and isotope ratios. The careful and extensive gas purification procedures required to remove impurities for reliable GCMS measurements will not be required for an IR laser gas analysis. The infrared laser gas analysis technique is being developed to measure stable isotopic ratios of gases such as CO2, CH4, N2O, and NH3. This will eventually lead to development of instruments capable of in situ istopic measurements on planets such as Mars. The carbon (C-12, C-13) isotope ratio is indicative of the type of carbon fixation mechanisms (e.g., photosynthesis, respiration) in operation on a planet, while the nitrogen (N-14, N-15) isotope ratio can probably be used to date nitrogen-bearing Martian samples. The absorbance ratio of two adjacent lines of CO2 in the 2300/cm (4.3 micron) region of the spectrum was measured. The precision of the measurement is presently better than 1 percent and significant improvement is anticipated as rapid sweep-integration techniques and computer controlled data acquistion capabilities are incorporated.

Becker, J. F.↗

Acoustic Steady-State Excitation Spatial Spectroscopy (ASSESS)

Safely launching and landing spacecraft, especially reusable spacecraft, requires detailed inspections of the launch vehicle to identify potential manufacturing and service-induced flaws. As an automated full-structure ultrasonic scanning technology, Acoustic Steady-State Excitation Spatial Spectroscopy (ASSESS) can rapidly and non-intrusively detect a wide variety of defects in applications where identifying subtle flaws is paramount. ASSESS is a non-destructive evaluation technology that leverages continuous excitation and laser Doppler vibrometry to make fast, high-quality inspections at stand-off distances. The ASSESS technology has undergone extensive laboratory testing and several field tests specific to oil and gas and additive manufacturing applications. We seek a commercialization partner to fund aerospace application-specific R&D and product development through a Cooperative Research and Development Agreement (CRADA).

42 ENGINEERING↗

Passive remote sensing of stratospheric and mesospheric winds

A passive infrared sensor for remote sounding of the wind field in the stratosphere and mesosphere from near earth orbital spacecraft is described. The sensor utilizes gas correlation spectroscopy and electrooptic phase-modulation techniques to measure winds in the 20-120 km altitude range, temperature, and atmospheric species concentrations. The operation of the sensor is examined. The sensitivity of the sensor is small Doppler shifts in an observed spectrum and the performance of the instrument were evaluated using laboratory simulation and numerical modeling. The data reveal that the sensor's wind measurements should have an accuracy better than 5 m/s and a spatial resolution of 5 km vertical by 150 km horizontal.

Mccleese, D. J.↗

Utilizing Quantum Cascade Lasers for Ultranarrow Velocity Resolution and Quantum-State Selectivity in Molecular Beam Scattering and Spectroscopy

Here, we demonstrate the capability of a narrow linewidth quantum cascade laser (QCL) to selectively excite a very narrow velocity range of nitric oxide (σ ≤ 7(3) m/s) with a pure ro-vibrational quantum state. By implementing a counter-propagating geometry, the molecules are selectively excited according to the Doppler shift of the ro-vibrational transition frequency such that the velocity width associated with the excited molecules depends only on the QCL linewidth. We demonstrate a velocity distribution limited by the effective linewidth of our free-running QCL (Γ = 3.2 MHz). Our development provides a cost-effective, flexible approach to resolve quantum-state selective chemical dynamics with excellent velocity resolution in a wide variety of molecules with infrared-active transitions. This technique has been formulated to provide ultrahigh collisional energy resolution in molecular beams to delineate final quantum-state product pairs in studies of molecular collisions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting Local Material Thickness from Steady-State Ultrasonic Wavefield Measurements Using a Convolutional Neural Network

Acoustic steady-state excitation spatial spectroscopy (ASSESS) is a full-field, ultrasonic non-destructive evaluation (NDE) technique used to locate and characterize defects in plate-like structures. ASSESS generates a steady-state, single-tone ultrasonic excitation in a structure and a scanning laser Doppler Vibrometer (LDV) measures the resulting full-field surface velocity response. Traditional processing techniques for ASSESS data rely on wavenumber domain analysis. This paper presents the alternative use of a convolutional neural network (CNN), trained using simulated ASSESS data, to predict the local plate thickness at every pixel in the wavefield measurement directly. The defect detection accuracy of CNN-based thickness predictions are shown to improve for defects of greater size, and for defects with higher thickness reductions. The CNN demonstrates the ability to predict thickness accurately in regions where Lamb wave dispersion relations are complex or unknown, such as near the boundaries of a test specimen, so long as the CNN is trained on data that accounts for these regions. The CNN also shows generalizability to ASSESS experimental data, despite an entirely simulated training dataset.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combustion Zone Characterization of GO2/GH2 Rocket Using Laser-Induced Fluorescence of OH

A series of studies were undertaken to measure various parameters such as velocity, species concentration, and temperature downstream of a shear coaxial injector in an optically accessible uni-element rocket chamber. Techniques applied include: laser Doppler velocimetry (LDV) for velocity; laser light scattering (LLS) for flow visualization and estimating mixture fraction and density; laser induced fluorescence (LIF) of hydroxyl radials (OH) to determine the characteristics and extent of the reaction zone; and Raman spectroscopy to measure major species concentration and temperature.

Moser, M. D.↗