Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Critical target and dose and dose-rate responses for the induction of chromosomal instability by ionizing radiation

To investigate the critical target, dose response and dose-rate response for the induction of chromosomal instability by ionizing radiation, bromodeoxyuridine (BrdU)-substituted and unsubstituted GM10115 cells were exposed to a range of doses (0.1-10 Gy) and different dose rates (0.092-17.45 Gy min(-1)). The status of chromosomal stability was determined by fluorescence in situ hybridization approximately 20 generations after irradiation in clonal populations derived from single progenitor cells surviving acute exposure. Overall, nearly 700 individual clones representing over 140,000 metaphases were analyzed. In cells unsubstituted with BrdU, a dose response was found, where the probability of observing delayed chromosomal instability in any given clone was 3% per gray of X rays. For cells substituted with 25-66% BrdU, however, a dose response was observed only at low doses (<1.0 Gy); at higher doses (>1.0 Gy), the incidence of chromosomal instability leveled off. There was an increase in the frequency and complexity of chromosomal instability per unit dose compared to cells unsubstituted with BrdU. The frequency of chromosomal instability appeared to saturate around approximately 30%, an effect which occurred at much lower doses in the presence of BrdU. Changing the gamma-ray dose rate by a factor of 190 (0.092 to 17.45 Gy min(-1)) produced no significant differences in the frequency of chromosomal instability. The enhancement of chromosomal instability promoted by the presence of the BrdU argues that DNA comprises at least one of the critical targets important for the induction of this end point of genomic instability.

NASA Discipline Radiation Health↗

SU-E-T-462: Impact of the Radiochromic Film Energy Response On Dose Measurements of Low Energy Electronic Brachytherapy Sources

Purpose: We investigated the effect of the EBT3 GafChromicTM film model absorbed dose energy response when used for percent depth dose (PDD) measurements in low-energy photon beams. Methods: We measured PDDs in water from a Xoft 50 kVp source using EBT3 film, and compared them to PDD measurements acquired with a PTW-TN34013 parallel-plate ionization chamber. For the x-ray source, we simulated spectra using the EGSnrc (BEAMnrc) Monte Carlo code, and calculated Half Value Layer (HVL) at different distances from the source in water. Pieces of EBT3 film were irradiated in air and calibration curves were created in terms of air-kerma in air ((Kair)air) for different beam qualities. Pieces of EBT3 film were positioned at distances of 2–6 cm from the Xoft source in a water phantom using a custom-made holder, and irradiated at the same time. As scatter is incorporated in the measured film signal in water, measured (Kair)wat was subsequently converted into absorbed dose to water by the ratio of mass energy absorption coefficients following the AAPM TG-61 dosimetry protocol. Results: Our results show that film calibration curves obtained at beam qualities near the effective energy of the Xoft 50 kVp source in water lead to variation in absorbed dose energy dependence of the response of around 3%. However, if the calibration curve was established at MV beam quality, the error in absorbed dose could be as large as 15%. We observed agreement within 1% between PDD measurements using EBT3 film model (using a calibration curve obtained at 80 kVp, HVL=2.18 mm Al, Eeff=29.5 keV) and the parallel-plate ionization chamber. Conclusion: Accurate dose measurements using radiochromic films at low photon energies require that the radiochromic film dosimetry system be calibrated at corresponding low energies, as large absorbed dose errors are expected for calibrations performed at MV beam qualities.

61 RADIATION PROTECTION AND DOSIMETRY↗

A two dimensional silicon detectors array for quality assurance in stereotactic radiotherapy: MagicPlate-512

Purpose: Silicon diode arrays are commonly implemented in radiation therapy quality assurance applications as they have a number of advantages including: real time operation (compared to the film) and high spatial resolution, large dynamic range and small size (compared to ionizing chambers). Most diode arrays have detector pitch that is too coarse for routine use in small field applications. The goal of this work is to characterize the two-dimensional monolithic silicon diode array named “MagicPlate-512” (MP512) designed for QA in stereotactic body radiation therapy (SBRT) and stereotactic radio surgery (SRS). Methods: MP512 is a silicon monolithic detector manufactured on ap-type substrate. An array contains of 512 pixels with size 0.5 × 0.5 mm{sup 2} and pitch 2 mm with an overall dimension of 52 × 52 mm{sup 2}. The MP512 monolithic detector is wire bonded on a printed circuit board 0.5 mm thick and covered by a thin layer of raisin to preserve the silicon detector from moisture and chemical contamination and to protect the bonding wires. Characterization of the silicon monolithic diode array response was performed, and included pixels response uniformity, dose linearity, percent depth dose, output factor, and beam profiling for beam sizes relevant to SBRT and SRS and depth dose response in comparison with ionization chamber. Results: MP512 shows a good dose linearity (R{sup 2} = 0.998) and repeatability within 0.2%. The measured depth dose response for field size of 10 × 10 cm{sup 2} agreed to within 1.3%, when compared to a CC13 ionization chamber for depths in PMMA up to 30 cm. The output factor of a 6 MV Varian 2100EX medical linac beam measured by MP512 at the isocenter agrees to within 2% when compared to PTW diamond, Scanditronix point EDD-2 diode and MOSkin detectors for field sizes down to 1 × 1 cm{sup 2}. An over response of 4% was observed for square beam size smaller than 1 cm when compared to EBT3 films, while the beam profiles (FWHM) of MP512 match to within 2% the data measured by radiochromic film. Conclusions: The response of the 2D detector array, MP512, has been evaluated. The properties of the array demonstrated suitability for use as in phantom dosimeter for QA in SRS and SBRT. Although MP512 matches film measurements down to 1 × 1 cm{sup 2} well, it showed a discrepancy of 4% in the determination of output factors of beams smaller than 0.5 × 0.5 cm{sup 2} due to the field perturbation generated by the large amount of silicon surrounding the central diode. MP512 is highly capable of measuring beam size (FWHM) and has a discrepancy of less than 1.3% when compared to EBT3 film. A reduction in the detector pitch to less than 2 mm would improve the penumbra reconstruction accuracy at the cost readout electronics complexity.

07 ISOTOPE AND RADIATION SOURCES↗

Understanding how molecular hydrogen impacts the total dose and dose rate response of linear bipolar circuits

Recent Enhanced Low Dose Rate Sensitivity (ELDRS) investigations carried out by RLP Research, Arizona State University (ASU) and Jet Propulsion Laboratory (JPL) have shown significant differences in the degradation of bipolar micro-circuits with total dose in the presence of molecular hydrogen (H2) in packages. This has a significant impact on radiation hardness assurance and opens up opportunities to improve device performance. The general objectives of this program are to: 1. Determine the extent to which hydrogen contamination affects the total dose and dose rate response of linear bipolar circuits; 2. Develop a model that will enable the prediction of high dose rate (HDR) and low dose rate (LDR) response asymptotes and transition dose rates as a function of total dose, temperature, pressurized hydrogen, defect precursors, and other process dependent variables; 3. Explore the possibility of an accelerated hardness assurance method and possible hardening approaches; and 4. Extend the work to other technologies that have total dose response affected by hydrogen contamination.In this document, we xperimentally demonstrate with test transistors and circuits that hydrogen is correlated with ELDRS in bipolar linear circuits. We show that the amount of hydrogen determines: 1) the total dose response versus dose rate and 2) the transition dose rates between the high and low dose rate responses. The experimental results are supported with a steady state drift/diffusion analytical model as well as modeling calculations using COMSOL Multiphysics.

Pease, Ron↗

Technical Note: Response measurement for select radiation detectors in magnetic fields

Purpose: Dose response to applied magnetic fields for ion chambers and solid state detectors has been investigated previously for the anticipated use in linear accelerator–magnetic resonance devices. In this investigation, the authors present the measured response of selected radiation detectors when the magnetic field is applied in the same direction as the radiation beam, i.e., a longitudinal magnetic field, to verify previous simulation only data. Methods: The dose response of a PR06C ion chamber, PTW60003 diamond detector, and IBA PFD diode detector is measured in a longitudinal magnetic field. The detectors are irradiated with buildup caps and their long axes either parallel or perpendicular to the incident photon beam. In each case, the magnetic field dose response is reported as the ratio of detector signals with to that without an applied longitudinal magnetic field. The magnetic field dose response for each unique orientation as a function of magnetic field strength was then compared to the previous simulation only studies. Results: The measured dose response of each detector in longitudinal magnetic fields shows no discernable response up to near 0.21 T. This result was expected and matches the previously published simulation only results, showing no appreciable dose response with magnetic field. Conclusions: Low field longitudinal magnetic fields have been shown to have little or no effect on the dose response of the detectors investigated and further lend credibility to previous simulation only studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early Brain Response to Low-Dose Radiation Exposure Involves Molecular Networks and Pathways Associated with Cognitive Functions, Advanced Aging and Alzheimer's Disease

Understanding the cognitive and behavioral consequences of brain exposures to low-dose ionizing radiation has broad relevance for health risks from medical radiation diagnostic procedures, radiotherapy, environmental nuclear contamination, as well as earth orbit and space missions. Analyses of transcriptome profiles of murine brain tissue after whole-body radiation showed that low-dose exposures (10 cGy) induced genes not affected by high dose (2 Gy), and low-dose genes were associated with unique pathways and functions. The low-dose response had two major components: pathways that are consistently seen across tissues, and pathways that were brain tissue specific. Low-dose genes clustered into a saturated network (p < 10{sup -53}) containing mostly down-regulated genes involving ion channels, long-term potentiation and depression, vascular damage, etc. We identified 9 neural signaling pathways that showed a high degree of concordance in their transcriptional response in mouse brain tissue after low-dose radiation, in the aging human brain (unirradiated), and in brain tissue from patients with Alzheimer's disease. Mice exposed to high-dose radiation did not show these effects and associations. Our findings indicate that the molecular response of the mouse brain within a few hours after low-dose irradiation involves the down-regulation of neural pathways associated with cognitive dysfunctions that are also down regulated in normal human aging and Alzheimer's disease.

59 BASIC BIOLOGICAL SCIENCES↗

SU-F-T-259: GPR Tables for the Estimation of Mid-Plane Dose Using EPID

Purpose: To develop a simple method for estimating the mid-plane dose (MPD) of a patient using Electronic Portal imaging Device (EPID). Methods: A Varian TrueBeam with aSi100 EPID was used in this study. The EPID images were acquired for a 30 cm × 30 cm homogeneous slab phantom and a 30 cm diameter 20 cm thick cylindrical phantom in the continuous dosimetry mode. The acquired EPID images in XIM format were imported into in-house MATLAB program for the data analysis. First, the dosimetric characteristics of EPID were studied for dose-response linearity, dose-rate dependence, and field size dependence. Next, the average pixels values of the EPID images were correlated with the MPD measured by an ionisation chamber for various thicknesses of the slab phantom (8 cm – 30 cm) and for various square field sizes (3×3 cm{sup 2} – 25×25 cm{sup 2} at the isocenter). Look-up tables called as GPR tables were then generated for both SSD and SAD setup by taking the ratio of MPD measured by the ionisation chamber and the corresponding EPID pixel values. The accuracy of the GPR tables was evaluated by varying the field size, phantom thickness, and wedge angles with the slab and cylindrical phantoms. Results: The dose response of EPID was linear from 20 MU to 300 MU. The EPID response for different dose rates from 40 MU/min to 600 MU/min was within ±1%. The difference in the doses from the GPR tables and the doses measured by the ionization chambers were within 2% for slab phantoms, and 3% for the cylindrical phantom for various field sizes, phantom thickness, and wedge angles. Conclusion: GPR tables are a ready reckoner for in-vivo dosimetry and it can be used to quickly estimate the MPD value from the EPID images with an accuracy of ±3% for common clinical treatment. project work funded by Union for International cancer control(UICC) under ICRETT fellowship.

60 APPLIED LIFE SCIENCES↗

Simulation and Application of Bayesian Dose Uncertainty Modeling for Low-Boom Community Noise Surveys

In dose-response modeling, failing to account for dose uncertainty can cause artificial flattening of the estimated slope of the dose-response curve. Previous analyses of NASA sonic boom community noise survey data utilized a Bayesian multilevel logistic regression model, which did not account for dose uncertainty. The current work extends the model to account for either classical or Berkson dose uncertainty. The extended model is applied to two simulated dose-response datasets to illustrate conditions under which the dose uncertainty term does and does not correct for the artificial flattening introduced by dose uncertainty. Finally, the extended model is applied to two previous NASA sonic boom community noise surveys. The resulting dose-response curve slope for the average participant is 5 to 10% steeper, but the difference in the noise dose that elicits a 5% highly annoyed response is small (less than 1 dB). The difference remains insignificant when producing population summary dose-response curves. Commentary is included on applicability to future X-59 low-boom community noise survey data modeling and analysis.

X-59↗

Chromosome aberrations among atomic-bomb survivors exposed in utero: updated analysis accounting for revised radiation doses and smoking

A previous study of peripheral blood lymphocyte translocations around age 40 among atomic-bomb survivors exposed in utero revealed no overall association with radiation dose—despite a clear association between translocations and dose among their mothers—but the data suggested an increase at doses below 100 mGy with a definite peak. That analysis of the in utero-exposed survivors did not adjust for their subsequent smoking behavior, an established cause of chromosomal aberrations, or their subsequent exposures to medical irradiation, a potential mediator. In addition, atomic-bomb survivor radiation dose estimates have subsequently been updated and refined. We therefore re-estimated the dose response using the latest DS02R1 dose estimates and adjusting for smoking as well as for city and proximal–distal location at the time of exposure to the atomic bomb. Sex of the survivor, mother’s age around the time of conception, and approximate trimester of gestation at the time of exposure were also considered as explanatory variables and modifiers. Precision of the estimated dose response was slightly lower due to greater variability near zero in the updated dose estimates, but there was little change in evidence of a low-dose increase and still no suggestion of an overall increase across the entire dose range. Adjustment for smoking behavior led to a decline in background number of translocations (the dose–response intercept), but smoking did not interact with dose overall (across the entire dose range). Adjustment for medical irradiation did not alter the association between dose and translocation frequency. Sex, mother’s age, and trimester were not associated with number of translocations, nor did they interact with dose overall. Interactions with dose in the low-dose range could not be evaluated because of numerical instability.

59 BASIC BIOLOGICAL SCIENCES↗

WE-AB-BRA-02: Development of Biomechanical Models to Describe Dose-Volume Response to Liver Stereotactic Body Radiation Therapy (SBRT) Patients

Purpose: Previous studies have shown that radiotherapy treatment for liver metastases causes marked liver hypertrophy in areas receiving low dose and atrophy/fibrosis in areas receiving high dose. The purpose of this work is to develop and evaluate a biomechanical model-based dose-response model to describe these liver responses to SBRT. Methods: In this retrospective study, a biomechanical model-based deformable registration algorithm, Morfeus, was expanded to include dose-based boundary conditions. Liver and tumor volumes were contoured on the planning images and CT/MR images three months post-RT and converted to finite element models. A thermal expansion-based relationship correlating the delivered dose and volume response was generated from 22 patients previously treated. This coefficient, combined with the planned dose, was applied as an additional boundary condition to describe the volumetric response of the liver of an additional cohort of metastatic liver patients treated with SBRT. The accuracy of the model was evaluated based on overall volumetric liver comparisons and the target registration error (TRE) using the average deviations in positions of identified vascular bifurcations on each set of registered images, with a target accuracy of the 2.5mm isotropic dose grid (vector dimension 4.3mm). Results: The thermal expansion coefficient models the volumetric change of the liver to within 3%. The accuracy of Morfeus with dose-expansion boundary conditions a TRE of 5.7±2.8mm compared to 11.2±3.7mm using rigid registration and 8.9±0.28mm using Morfeus with only spatial boundary conditions. Conclusion: A biomechanical model has been developed to describe the volumetric and spatial response of the liver to SBRT. This work will enable the improvement of correlating functional imaging with delivered dose, the mapping of the delivered dose from one treatment onto the planning images for a subsequent treatment, and will further provide information to assist with the biological characterization of patients’ response to radiation.

60 APPLIED LIFE SCIENCES↗

Effect of Radiotherapy Volume and Dose on Secondary Cancer Risk in Stage I Testicular Seminoma

Purpose: To estimate and compare the secondary cancer risk (SCR) due to para-aortic (PA), dogleg field (DLF), or extensive field (EF) radiotherapy (RT) at different dose levels for Stage I testicular seminoma. Methods and Materials: The organ equivalent dose concept with a linear, plateau, and linear-exponential dose-response model was applied to the dose distributions to estimate the SCR. The dose distributions were calculated in a voxel-based anthropomorphic phantom. Three different three-dimensional plans were computed: PA, DLF, and EF. The plans were calculated with 6-MV photons and two opposed fields, using 20 Gy in 10 fractions. Results: The estimated cumulative SCR for a 75-year-old patient treated with PA-RT at age 35 was 23.3% (linear model), 20.9% (plateau model), and 20.8% (linear-exponential model) compared with 19.8% for the general population. Dependent on the model, PA-RT compared with DLF-RT reduced the SCR by 48-63% or 64-69% when normalized to EF-RT. For PA-RT, the linear dose-response model predicted a decrease of 45% in the SCR, using 20 Gy instead of 30 Gy; the linear-exponential dose-response model predicted no change in SCR. Conclusion: Our model suggested that the SCR after PA-RT for Stage I testicular seminoma is reduced by approximately one-half to two-thirds compared with DLF-RT, independent of the dose-response model. The SCR is expected to be equal or lower with 20 Gy than with 30 Gy. In the absence of mature patient data, the organ equivalent dose concept offers the best potential method of estimating the SCR when discussing treatment options with patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-264: Preliminary Results On New Optically Stimulated Luminescent Materials for Proton Therapy Dosimetry

Purpose: The objective of this work is to test the premise that luminescence materials with less under-response to proton beams can be identified by testing their dose response to low-LET radiation. The goal is to develop new Optically Stimulated Luminescence (OSL) materials with improved response for proton therapy dosimetry. Methods: We first measured the dose response of new OSL materials, synthesized in our laboratory, to low-LET radiation (beta rays from a {sup 90}Sr/{sup 90}Y source) and selected two materials having different OSL saturation characteristics and good dosimetric properties, namely MgB4O7:Ce,Li and MgO:Li. Commercial Al2O3:C was also used for comparison. These materials were then irradiated at several depths along a pristine proton beam. The luminescence responses of the materials, relative to the entrance response, were compared with the depth dose profile measured by a multiple-layer ion chamber. Results: The OSL signals of MgB4O7:Ce,Li and MgO:Li were characterized for signal stability, dose response, and response to a clinical proton beam. The materials were also compared with the commercial Al2O3:C. The signals from both MgB4O7:Ce,Li and MgO:Li were relatively stable after a one day delay following irradiation. The low-LET dose response of the materials showed that, over the dose range investigated (up to ∼800 Gy), MgB4O7:Ce,Li did not saturate, whereas MgO:Li and Al2O3:C saturated at doses of ∼100 Gy. MgB4O7:Ce,Li showed less underresponse to proton beams than MgO:Li and Al2O3:C. Conclusion: In general the material with the highest saturation doses for low-LET radiation (MgB4O7:Ce,Li) showed the least under-response to proton beams, which suggests that it may be possible to develop better OSL materials for proton dosimetry if the dose response can be controlled during synthesis. Nevertheless, the degree in which the response to proton beams can be controlled remains to be determined. The research is funded by the Oklahoma Center for the Advancement of Science and Technology (OCAST), project number HR12-055.

07 ISOTOPE AND RADIATION SOURCES↗

Low-Dose Hypersensitive Response for Residual pATM and γH2AX Foci in Normal Fibroblasts of Cancer Patients

To define the dose–response relationship for initial and residual pATM and γH2AX foci and temporal response of pATM foci in fibroblasts of 4 hyper-radiosensitivity (HRS)-positive cancer patients and 8 HRS-negative cancer patients and answer the question regarding the role of DNA double-strand break (DSB) recognition and repair in the mechanism of HRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiotherapy After Prostatectomy: Is the Evidence for Dose Escalation out There?

Purpose: To study the effective doses of radiotherapy (RT) after prostatectomy in search for evidence of a dose-response. Methods and Materials: Original and available data from published studies of adjuvant and salvage RT after prostatectomy were analyzed in the context of biochemical tumor control probability (TCP) dose-response curves. Comparisons were made with dose-escalation studies of radical RT for localized disease. Arguments based on a microscopic vs. macroscopic disease dose-response relationships were used to interpret the clinical data. Results: The tumor control rates after salvage RT were consistent with the TCP dose-response curve of radical RT, suggesting the presence of macroscopic-equivalent disease among salvage patients. For radical RT, the dose to achieve 50% biochemical tumor control was 65.9 Gy (95% confidence interval [CI], 64.8-66.8) and the Slope{sub 50} was 2.6%/Gy (95% CI, 2.3-3.0). For salvage RT, the corresponding values were 66.8 Gy (95% CI, 65.1-68.4) and 3.8%/Gy (95% CI, 2.5-7.6). For a comparable TCP, the dose for adjuvant RT was {approx}6 Gy lower, consistent with one-tenth the burden of local disease. The present doses for adjuvant or salvage RT in the range of 60-70 Gy appear to be still on the steep part of the TCP dose-response curve. Conclusions: The effective doses and dose-response relation observed with RT after prostatectomy are consistent with the presence of macroscopic-equivalent disease for salvage patients and about a tenth of the residual disease for adjuvant patients. Greater doses would potentially achieve significantly greater disease-free control rates. A randomized trial with 250 patients comparing 64 vs. 70 Gy for salvage RT or 60 vs. 66 Gy for adjuvant RT would be capable of addressing this issue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams

Purpose: This work investigates the energy response and dose-response curve determinations for XR-QA2 radiochromic film dosimetry system used for synchrotron radiation work and for quality assurance in diagnostic radiology, in the range of effective energies 18–46.5 keV. Methods: Pieces of XR-QA2 films were irradiated, in a plane transverse to the beam axis, with a monochromatic beam of energy in the range 18–40 keV at the ELETTRA synchrotron radiation facility (Trieste, Italy) and with a polychromatic beam from a laboratory x-ray tube operated at 80, 100, and 120 kV. The film calibration curve was expressed as air kerma (measured free-in-air with an ionization chamber) versus the net optical reflectance change (netΔR) derived from the red channel of the RGB scanned film image. Four functional relationships (rational, linear exponential, power, and logarithm) were tested to evaluate the best curve for fitting the calibration data. The adequacy of the various fitting functions was tested by using the uncertainty analysis and by assessing the average of the absolute air kerma error calculated as the difference between calculated and delivered air kerma. The sensitivity of the film was evaluated as the ratio of the change in net reflectance to the corresponding air kerma. Results: The sensitivity of XR-QA2 films increased in the energy range 18–39 keV, with a maximum variation of about 170%, and decreased in the energy range 38–46.5 keV. The present results confirmed and extended previous findings by this and other groups, as regards the dose response of the radiochromic film XR-QA2 to monochromatic and polychromatic x-ray beams, respectively. Conclusions: The XR-QA2 radiochromic film response showed a strong dependence on beam energy for both monochromatic and polychromatic beams in the range of half value layer values from 0.55 to 6.1 mm Al and corresponding effective energies from 18 to 46.5 keV. In this range, the film response varied by 170%, from a minimum sensitivity of 0.0127 to a maximum sensitivity of 0.0219 at 10 mGy air kerma in air. The more suitable function for air kerma calibration of the XR-QA2 radiochromic film was the power function. A significant batch-to-batch variation, up to 55%, in film response at 120 kV (46.5 keV effective energy) was observed in comparison with published data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancement of phototropic response to a range of light doses in Triticum aestivum coleoptiles in clinostat-simulated microgravity

The phototropic dose-response relationship has been determined for Triticum aestivum cv. Broom coleoptiles growing on a purpose-built clinostat apparatus providing gravity compensation by rotation about a horizontal axis at 2 rev min-1. These data are compared with data sets obtained with the clinostat axis vertical and stationary, as a 1 g control, and rotating vertically to examine clinostat effects other than gravity compensation. Triticum at 1 g follows the well-established pattern of other cereal coleoptiles with a first positive curvature at low doses, followed by an indifferent response region, and a second positive response at progressively increasing doses. However, these response regions lie at higher dose levels than reported for Avena. There is no significant difference between the responses observed with the clinostat axis vertical in the rotating and stationary modes, but gravity compensation by horizontal rotation increases the magnitude of first and second positive curvatures some threefold at 100 min after stimulation. The indifferent response is replaced by a significant curvature towards the light source, but remains apparent as a reduced curvature response at these dose levels.

Non-NASA Center↗

The Susceptibility of Juvenile American Shad to Rapid Decompression and Fluid Shear Exposure Associated with Simulated Hydroturbine Passage

Throughout many areas of their native range, American shad (Alosa sapidissima) and other Alosine populations are in decline. Though several conditions have influenced these declines, hydropower facilities have had significant negative effects on American shad populations. Hydropower facilities expose ocean-migrating American shad to physical stressors during passage through hydropower facilities, including strike, rapid decompression, and fluid shear. In this laboratory-based study, juvenile American shad were exposed separately to rapid decompression and fluid shear to determine their susceptibility to these stressors and develop dose–response models. These dose–response relationships can help guide the development and/or operation of hydropower turbines and facilities to reduce the negative effects to American shad. Relative to other species, juvenile American shad have a high susceptibility to both rapid decompression and fluid shear. Reducing or preventing exposure to these stressors at hydropower facilities may be a potential method to assist in the effort to restore American shad populations.

13 HYDRO ENERGY↗

Non-Target Effect for Chromosome Aberrations in Human Lymphocytes and Fibroblasts After Exposure to Very Low Doses of High LET Radiation

The relationship between biological effects and low doses of absorbed radiation is still uncertain, especially for high LET radiation exposure. Estimates of risks from low-dose and low-dose-rates are often extrapolated using data from Japanese atomic bomb survivor with either linear or linear quadratic models of fit. In this study, chromosome aberrations were measured in human peripheral blood lymphocytes and normal skin fibroblasts cells after exposure to very low dose (.01 - 0.2 Gy) of 170 MeV/u Si-28-ions or 600 MeV/u Fe-56-ions. Chromosomes were analyzed using the whole chromosome fluorescence in situ hybridization (FISH) technique during the first cell division after irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving >2 breaks in 2 or more chromosomes). The curves for doses above 0.1 Gy were more than one ion traverses a cell showed linear dose responses. However, for doses less than 0.1 Gy, Si-28-ions showed no dose response, suggesting a non-targeted effect when less than one ion traversal occurs. Additional findings for Fe-56 will be discussed.

Hada, Megumi↗