Search NASA⌕ Search

SEARCH · Search NASA

Results for “Duration and intensity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Review of Water and Climate Change Analysis in Electric Utility Integrated Resource Planning

The purpose of this paper is to examine the extent to which electric utility integrated resource plans (IRPs) evaluate the impact of water constraints on electric generation resource portfolios and the extent to which IRPs consider the impacts of climate change to generation and loads. This white paper reviewed 30 IRPs to determine best practices with respect to analyzing and reporting on potential water-based and climate change risks within the integrated resource planning process. Best practices from electric utility IRPs are identified and additional recommendations and considerations are put forth. In recent years, thermal generating facilities have experienced challenges with water availability: a shortage of cooling water, conditions in which incoming cooling water is too warm for optimal operation, and/or water discharge temperatures exceeding permit limits. S&P Global Market Intelligence recently reported on a study that identified for the year 2030, 98.2 gigawatts (GW) of coal capacity at risk due to water stress. Climate change effects on hydrological cycles may adjust the timing, temperature, and volume of water availability for thermal electric cooling and for hydropower generation, which could further exacerbate the frequency and duration of operational constraints. Climate change can also impact the timing and intensity of electric loads that utilities must serve, most notably for heating and cooling.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Single-shot complete spatiotemporal measurement of terawatt laser pulses

In this work, we demonstrate, for the first time, a single-shot, complete spatiotemporal measurement of pulses from a terawatt-scale, multi-stage-amplified, low repetition-rate laser source. The ultrashort pulse electric field, E(x,y,z,t), is spatiotemporally complex due to distortions that accrue from multiple chirped-pulse amplifiers, which requires a complete characterization. Meanwhile, the instability of the laser source introduces field profiles that vary significantly from pulse to pulse, which, together with the low repetition-rate (15 shots/hour), requires the use of a single-shot measurement technique. To accomplish the measurements, we used a wavelength-multiplexed, digital-holographic technique called Spatially and Temporally Resolved Intensity and Phase Evaluation Device: Full Information from a Single Hologram, specially tailored to measure picosecond pulses at a wavelength of about 1 μm. Specifically, individual pulses from the compact multipulse terawatt laser were measured, with up to 0.3 J per shot of energy and ~2 ps pulse durations, at 1052 nm. With these measurements, we characterized several major spatiotemporal distortions that affect the peak intensity at the laser focus, as well as the pulse-shape instability on a shot-to-shot basis. Our technique allows detailed diagnosis of laser pulses (especially high-order spatiotemporal distortions) and provides straightforward four-dimensional animations of pulse propagation to a focus.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards isolated attosecond electron bunches using ultrashort-pulse laser-solid interactions

We investigate MeV-level attosecond electron bunches from ultrashort-pulse laser-solid interactions through similarities between experimental and simulated electron energy spectra. We show measurements of the bunch duration and temporal structure from particle-in-cell simulations. The experimental observation of such bunches favors specular reflection direction when focusing the laser pulse onto a subwavelength boundary of thick overdense plasmas at grazing incidence. Particle-in-cell simulation further reveals that the attosecond duration is a result of ultra-thin (~tenth of a micron) gaps of zero electromagnetic energy density in the modulated reflected radiation, while the bunching (locally peaked electron concentration) comes from the highly-directional electron angular distribution acquired by the electrons in a grazing incidence setup. To isolate a single electron bunch, we perform simulations using 1-cycle laser pulses and analyze the effect of carrier-envelop phase with particle tracking. The duration of the electron bunch can be further decreased by increasing the laser intensity and the focal spot size, while its direction can be changed by tuning the preplasma density gradient.

High-harmonic generation↗

Transmission spectroscopy of CF 4 molecules in intense x-ray fields

The nonlinear interaction of x rays with matter is at the heart of understanding and controlling ultrafast molecular dynamics from an atom-specific viewpoint, providing new scientific and analytical opportunities to explore the structure and dynamics of small quantum systems. At increasingly high x-ray intensity, the sensitivity of ultrashort x-ray pulses to specific electronic states and emerging short-lived transient intermediates is of particular relevance for our understanding of fundamental multiphoton absorption processes. In this work, intense x-ray free-electron laser (XFEL) pulses at the European XFEL are combined with a gas cell and grating spectrometer for a high-intensity transmission spectroscopy study of multiphoton-induced ultrafast molecular fragmentation dynamics in CF 4 . This approach unlocks the direct intrapulse observation of transient fragments, including neutral atoms, by their characteristic absorption lines in the transmitted broadband x-ray spectrum. The dynamics with and without initially producing fluorine 𝐾-shell holes are studied by tuning the central photon energy. The absorption spectra are measured at different FEL intensities to observe nonlinear effects. Transient isolated fluorine atoms and ions are spectroscopically recorded within the ultrashort pulse duration of a few tens of femtoseconds. An isosbestic point that signifies the correlated transition between intact neutral CF 4 molecules and charged atomic fragments is observed near the fluorine 𝐾 edge. The dissociation dynamics and the multiphoton absorption-induced dynamics encoded in the spectra are theoretically interpreted. Overall, this study demonstrates the potential of high-intensity x-ray transmission spectroscopy to study ultrafast molecular dynamics with sensitivity to specific intermediate species and their electronic structure.

74 ATOMIC AND MOLECULAR PHYSICS↗

Six-photon resonant scattering of collinear laser pulses in plasma

To achieve the highest possible laser intensities with the least laser energy, shorter-wavelengths lasers are advantaged if they can be focused to spots of a few laser wavelengths and durations of several laser periods. However, the top laser pulse energies available nowadays are megajoules at near-optical wavelengths and millijoules at shorter wavelengths. Thus, to produce the highest laser intensities, what is required is an efficient spectral transfer of the huge near-optical energies to shorter wavelengths. It is proposed here that the desired spectral transfer could occur via resonant photon interactions associated with nonlinearity of mildly relativistic motions of plasma electrons in intense laser fields, specifically via the six-photon resonant scattering of collinear laser pulses in plasma. As a result, the six-photon interaction can, in fact, be the dominant resonant photon interaction to achieve collinear frequency up-conversion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluating methods to reduce duration of near-threshold fatigue crack growth rate measurements for low-alloy steels in hydrogen gas

Measurement of the near-threshold fatigue crack growth rate (da/dN) vs. stress-intensity factor range (∆K) relationship in hydrogen gas is essential for maximizing the calculated design fatigue life of high-pressure hydrogen storage vessels. However, such measurements are rarely performed, since the low cyclic loading frequencies applied in standard practice lead to prohibitively protracted test durations. The objective of this study was to demonstrate two means for reducing test durations when measuring near-threshold da/dN vs. ΔK relationships under decreasing ΔK for low-alloy pressure vessel steels in hydrogen gas: 1) imposing steeper K-gradients relative to the recommended limits in standards such as ASTM E647, and 2) increasing cyclic loading frequency relative to typical values applied during fatigue crack growth testing of low-alloy steels in hydrogen gas. Recognizing that steeper K-gradients could amplify loading-history effects, test methods employing this approach were designed to mitigate such effects by either maintaining constant K max or gradually increasing the K-gradient as the threshold was approached. Although the varying K-gradient method was vulnerable to loading-history effects in the form of plasticity-induced crack closure, particularly at lower stress ratio (R) and higher starting K max values, these effects could be compensated by applying the adjusted compliance ratio (ACR) method. Here, it was demonstrated that steeper K-gradients in concert with increased cyclic loading frequency reduced the duration of near-threshold fatigue crack growth tests in hydrogen gas by more than 99% relative to standard practices.

Fatigue threshold↗

Spectral studies of soft x-ray radiation of laser-produced plasma of various target materials in a wide spectral range

Here, the work is devoted to experimental study of soft X-ray radiation spectra of laser produced plasma in a wide spectral range 5–100 Å at the “Kamerton” facility (GPI) with pulse duration 70 ps, pulse energy 1–5 J, wavelength 0.53 microns at which the laser intensity (power flux density) of 7×10 14 – 3.5×10 15 W/cm 2 was achieved. A spectrograph was used, which had transmission diffraction gratings with a ratio of the elementary gap to the period of the structure of 0.25 and 0.41. Detection was performed on both UV-4 X-ray photo film and Fuji TR fluorescent imaging plate. Solid samples from Al, Si, Ti, Cu, Ta and W were used as targets. The ionization states of the plasma corresponding to various electron temperatures were calculated, which made it possible to estimate the electron temperature by comparison these calculation results with the experimentally obtained spectra. The estimated electron temperature, which depends on the laser pulse energy and the target material, varied within the range of 100–450 eV. To verify the correctness of the temperature estimations obtained by such comparison a numerical simulation of plasma radiation was carried out by the use of PrismSPECT computer program. It was found that the results of this simulation are in a good agreement with estimations on the base of experimentally obtained spectra. The analysis of these spectra showed that tantalum, tungsten or titanium targets are the best candidates among the tested ones for the use of laser produced plasma as a radiation source in the "water window" spectral range (23–44 Å) for applications in biology and medicine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar-Tracker Diffuse-Response Algorithm for Balancing Energy Gain and Mechanical Wear in Photovoltaic Systems

Single-axis solar tracking maximizes photovoltaic energy production under clear-sky conditions; however, its effectiveness decreases under cloudy and overcast skies, where diffuse irradiance dominates and the optimal module orientation changes. Conventional tracking algorithms either neglect sky conditions or rely on simplified diffuse-response strategies that may trigger frequent tracker repositioning under variable cloud cover, leading to increased mechanical wear with marginal energy gains. This work proposes an enhanced diffuse-response tracking algorithm that explicitly accounts for both the intensity and temporal persistence of cloudiness. By requiring overcast conditions to persist for a minimum duration before reorienting the tracker to a diffuse-stow position, the proposed approach reduces unnecessary movements while preserving the benefits of diffuse-response operation. The algorithm is evaluated through numerical simulations based on historical meteorological data and validated using field measurements on monofacial and bifacial photovoltaic strings. The results show that the proposed strategy reduces excess tracker movement from 114% to 0.16% while maintaining nearly the same energy yield. Compared to a conventional diffuse-response algorithm, the associated energy reduction is minimal (≈0.17%) relative to the ≈0.37% yield gain observed at the studied location. These findings demonstrate that incorporating cloudiness duration enables a practical compromise between energy performance and tracker durability, particularly for monofacial photovoltaic systems.

14 SOLAR ENERGY↗

Detection of Thermal Emission at Millimeter Wavelengths from Low-Earth Orbit Satellites

The detection of satellite thermal emission at millimeter wavelengths is presented using data from the 3rd-Generation receiver on the South Pole Telescope (SPT-3G). This represents the first reported detection of thermal emission from artificial satellites at millimeter wavelengths. Satellite thermal emission is shown to be detectable at high signal-to-noise on timescales as short as a few tens of milliseconds. An algorithm for downloading orbital information and tracking known satellites given observer constraints and time-ordered observatory pointing is described. Consequences for cosmological surveys and short-duration transient searches are discussed, revealing that the integrated thermal emission from all large satellites does not contribute significantly to the SPT-3G survey intensity map. Measured satellite positions are found to be discrepant from their two-line element (TLE) derived ephemerides up to several arcminutes which may present a difficulty in cross-checking or masking satellites from short-duration transient searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging electron angular distributions to assess a full-power petawatt-class laser focus

Here we present a technique to assess the focal volume of petawatt-class lasers at full power. Our approach exploits quantitative measurement of the angular distribution of electrons born in the focus via ionization of rarefied gas, which are accelerated forward and ejected ponderomotively by the field. We show that a bivariate (θ,Φ) angular distribution, which was obtained with image plates, not only enables the peak intensity to be extracted, but also reflects nonideality of the focal-spot intensity distribution. In our prototype demonstration at intensities of a few ×10 19 to a few ×10 20 W/cm 2 , an f/10 optic produced a focal spot in the paraxial regime. This allows a plane-wave parametrization of the peak intensity given by tanθ c =2/a 0 (a 0 being the normalized vector potential and θ c the minimum ejection angle) to be compared with our measurements. Qualitative agreement was found using an a 0 inferred from the pulse energy, pulse duration, and focal spot distribution with a modified parametrization, tanθ c =2η/a 0 ($η=2.02^{+0.26}_{–0.22}$). This highlights the need for (i) better understanding of intensity degradation due to focal-spot distortions and (ii) more robust modeling of the ejection dynamics. Using single-shot detection of electrons, we showed that while there is significant shot-to-shot variation in the number of electrons ejected at a given angular position, the average distribution scales with the pulse energy in a way that is consistent with that seen with the image plates. Finally, we note that the asymptotic behavior as θ→0° limits the usability of angular measurement. For 800 nm, this limit is at an intensity ~10 21 W/cm 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental verification of TNSA protons and deuterons in the multi-picosecond moderate intensity regime

Ion acceleration from high intensity short pulse laser interactions is of great interest due to a number of applications, and there has been significant work carried out with laser energies up to a few 100 J with 10's of femtosecond to 1 ps pulse durations. Here, we report results from an experiment at the OMEGA EP laser, where laser energy and pulse length were varied from 100 to 1250 J and 0.7–30 ps, respectively, in the moderate (2 × 10 17 –2 × 10 18 W/cm 2 ) laser intensity regime. Ions and electrons were simultaneously measured from disk targets made of CH and CD by a Thomson parabola and a magnetic spectrometer, respectively. Measurements showed that the electron temperature, T e (MeV), has a dependence on the laser energy, E L (J), and pulse duration, τ L (ps), and its empirical scaling was found to be 0.015 × E L 0.90 τ L –0.48. The maximum proton and deuteron energies are linearly dependent on the electron temperature, (5.60 ± 0.26) × T e and (3.17 ± 0.18) × T e , respectively. A significant increase in proton numbers with the laser energy was also observed. Furthermore, the increase in the maximum proton energy and proton count with higher energy longer duration pulses presented in this article shows that such laser conditions have a great advantage for applications, such as the proton radiograph, in the moderate laser intensity regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

High-magnification Faraday rotation imaging and analysis of X-pinch implosion dynamics

An X-pinch load driven by an intense current pulse (>100 kA in ~100 ns) can result in the formation of a small radius, runaway compressional micro-pinch. A micro-pinch is characterized by a hot (>1 keV), current-driven (>100 kA), high-density plasma column (near solid density) with a small neck diameter (1–10 µm), a short axial extent (<1 mm), and a short duration (≲1 ns). With material pressures often well into the multi-Mbar regime, a micro-pinch plasma often radiates an intense, sub-ns burst of sub-keV to multi-keV x rays. A low-density coronal plasma immediately surrounding the dense plasma neck could potentially shunt current away from the neck and thus reduce the magnetic drive pressure applied to the neck. Here, to study the current distribution in the coronal plasma, a Faraday rotation imaging diagnostic (1064 nm) capable of producing simultaneous high-magnification polarimetric and interferometric images has been developed for the MAIZE facility at the University of Michigan. Designed with a variable magnification (1–10×), this diagnostic achieves a spatial resolution of ~35 µm, which is useful for resolving the ~100-μm-scale coronal plasma immediately surrounding the dense core. This system has now been used on a reduced-output MAIZE (100–200 kA, 150 ns) to assess the radial distribution of drive current immediately surrounding the dense micro-pinch neck. The total current enclosed was found to increase as a function of radius, r, from a value of ≈ 50 ± 25 kA at r ≈ 140 µm (at the edge of the dense neck) to a maximal value of ≈150 ± 75 kA for r ≥ 225 µm. This corresponds to a peak magnetic drive pressure of ≈75 ± 50 kbar at r ≈ 225 µm. The limitations of these measurements are discussed in the paper.

47 OTHER INSTRUMENTATION↗

High-Magnification Faraday Rotation Imaging and Analysis of X-pinch Implosion Dynamics

An X-pinch load driven by an intense current pulse (>100 kA in ~100 ns) can result in the formation of a small radius, runaway compressional micro-pinch. A micro-pinch is characterized by a hot (>1 keV), current-driven (>100 kA), high-density plasma column (near solid density) with a small neck diameter (1–10 μm), a short axial extent (<1 mm), and a short duration (.1 ns). With material pressures often well into the multi-Mbar regime, a micro-pinch plasma often radiates an intense, sub-ns burst of sub-keV to multi-keV x-rays. A low-density coronal plasma immediately surrounding the dense plasma neck could potentially shunt current away from the neck and thus reduce the magnetic drive pressure applied to the neck. To study the current distribution in the coronal plasma throughout the implosion process, a Faraday rotation imaging diagnostic (1064 nm) capable of producing simultaneous high-magnification polarimetric and interferometric images has been developed for the 1-MA, 100-ns MAIZE facility at the University of Michigan. Designed with a variable magnification (1–10&times;), this diagnostic achieves a spatial resolution of approximately 35 μm, which is useful for resolving the ~100-μm-scale coronal plasma region immediately surrounding the dense core. Combined with the corresponding interferogram, which provides the radial density distribution in the low-density coronal plasma, the measured rotation can be used to diagnose the delivery of the driver current, and thus the magnetic drive pressure, to the micro-pinch plasma as it approaches minimal radius. Using this technique on MAIZE, we have measured

Dowhan, G. V.↗

The role of focusing geometry in MeV x-ray production from petawatt laser–solid interaction

Relativistic laser–plasma interactions provide a compact and flexible route to generating bright, ultrashort pulses of MeV x rays, with applications in high-energy density science, nuclear physics, and radiography. Despite extensive study of intensity scaling in laser-driven electron acceleration, the role of focusing geometry and focal-volume effects in MeV radiation production remains insufficiently understood. Here, we present experimental and kinetic simulation results from the Texas Petawatt Laser (120 J, 140 fs) in which the focusing geometry (f/3 or f/1.5) is varied, while the laser energy and pulse duration are fixed. Experimentally, the f/3 geometry produces approximately three times more MeV radiation than the f/1.5 geometry, despite its twofold lower nominal vacuum intensity. This result is based on the time-integrated radiation per unit solid angle, as measured along the diagnostic line of sight. Three-dimensional particle-in-cell simulations reproduce this trend when a modest (10s of μm) effective focal plane shift is introduced, demonstrating that relativistic laser–plasma coupling is highly sensitive to focal geometry in the presence of a preplasma. This behavior is consistent with differences in interaction length and effective intensity at the critical surface between the two configurations. The sensitivity of the tightly focused f/1.5 configuration ($z_R ≈$⁠ 5 μ m) reflects the combined influence of thermal lensing and an extended preplasma, while the f/3 geometry (⁠$z_R ≈$ 80 μ m) remains comparatively robust. These results demonstrate a breakdown of conventional intensity scaling and identify focusing geometry as a critical control parameter for MeV electron and x-ray generation at petawatt powers. Implications for laser–plasma-based radiographic facilities are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of a single protein by ultrafast X-ray diffraction

The idea of using ultrashort X-ray pulses to obtain images of single proteins frozen in time has fascinated and inspired many. It was one of the arguments for building X-ray free-electron lasers. According to theory, the extremely intense pulses provide sufficient signal to dispense with using crystals as an amplifier, and the ultrashort pulse duration permits capturing the diffraction data before the sample inevitably explodes. This was first demonstrated on biological samples a decade ago on the giant mimivirus. Since then, a large collaboration has been pushing the limit of the smallest sample that can be imaged. The ability to capture snapshots on the timescale of atomic vibrations, while keeping the sample at room temperature, may allow probing the entire conformational phase space of macromolecules. Here we show the first observation of an X-ray diffraction pattern from a single protein, that of Escherichia coli GroEL which at 14 nm in diameter is the smallest biological sample ever imaged by X-rays, and demonstrate that the concept of diffraction before destruction extends to single proteins. From the pattern, it is possible to determine the approximate orientation of the protein. Our experiment demonstrates the feasibility of ultrafast imaging of single proteins, opening the way to single-molecule time-resolved studies on the femtosecond timescale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of Control of Laser-Plasma Instabilities in the Laboratory Using STUD Pulses (Spike Trains of Uneven Duration and Delay)

The success of laser Driven Inertial Fusion Technology (LaDrIFT) hinges on controlling laser-plasma instabilities (LPI) for effective and non-deleterious energy coupling, together with the control of implosion hydrodynamic instabilities (IHI) for target integrity. Conventional approaches ignore LPI and focus on IHI. LPI control suggests the use of low intensities, short wavelengths, and thus the slow implosions of thinner shells, while IHI control calls for thicker shells, fast implosions and thus at higher laser intensities and ablation pressures. These contradicting requirements severely restrict LaDrIFT design space, flexibility and scalability. This program demonstrates, with theoretical designs and their preliminary experimental realizations, that STUD pulses (Spike Trains of Uneven Duration and Delay) can control LPI in high-energy-density (HED) laser-created plasmas and explore this physics for the first time with high repetition (rep) rate lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of picosecond coherent anti-Stokes Raman spectra for gas-phase diagnostics

We present a hybrid frequency- and time-domain solution, applicable to the case of picosecond coherent anti-Stokes Raman scattering (CARS), for gas-phase diagnostics. A solution has been derived based on both physical arguments and four-wave mixing equations for picosecond CARS, with pulse durations that are comparable to the dephasing time scale for gas-phase Raman coherence—a regime where commonly employed solutions for impulsive (femtosecond) or cw (nanosecond) pump/Stokes forcing are not strictly valid. We present the ps-CARS spectrum in the form of incoherent sums of CARS intensity spectra, calculated from the fundamental solution for impulsive pump/Stokes Raman preparation. The solution was examined for temperatures from 1000–3000 K, for four plausible experimental configurations, with laser pulse durations of 50–150 ps, and probe pulse delays from −20 to 240 ps. Approximations based on cw and impulsive pump/Stokes preparation to fit picosecond CARS spectra at atmospheric pressure were examined and the relative thermometric accuracy and computational cost of these approximations were quantified for the case of a zero nonresonant CARS contribution, and a nonresonant susceptibility equal to 10% of the Raman-resonant value at the N 2 bandhead. The nanosecond CARS approximation can result in large fitting errors when the probe pulse time delay is less than the probe pulse duration. Errors as large as 10–20% are observed in the fit temperatures for a zero picosecond probe pulse delay, when the nonresonant background is neglected, largely due to an inability of the time-independent cw model to capture transient frequency spread dephasing effects at the Q -branch bandhead. The inclusion of a nonresonant background results in 40–60% thermometry errors with a nanosecond model at a zero-probe delay. Time-dependent impulsive calculations used for femtosecond CARS better approximate the structure of the N 2 bandhead, reducing temperature fitting errors to 5–10% at a short probe pulse delay. The impulsive approximation results in errors up to 10% at intermediate probe pulse delays, where the coherence of the pump and probe pulses leads to multiple terms in the picosecond CARS solution. Both approximations improve as the probe pulse delay exceeds the probe duration. The nanosecond approximation results in a 2–3% error, while the impulsive model results in differences of less than 1% in some cases. Fits to experimental data obtained using short, ∼60ps pulses at a zero probe time delay and longer 100 ps pulses at a substantial 200 ps delay are presented with accuracies of 1–3% in the fit temperature.

Kearney, Sean P.↗