Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Disruption modelling for engineering and physics design of ST-E1 fusion power plant

Plasma disruptions represent a critical challenge for high-performance tokamak operations, as they can compromise machine integrity and reduce operational availability. Although future fusion devices essentially need to incorporate strategies to minimise disruption occurrence, complete avoidance remains unattainable. Consequently, assessing and characterising unmitigated disruption consequences is fundamental for the design and qualification of next-generation fusion power plants. This work supports the pre-conceptual design of ST-E1, a low aspect-ratio Tokamak Fusion Power Plant developed by Tokamak Energy Ltd., by presenting a comprehensive disruption modelling approach applied across different design stages. The methodology integrates both physics and engineering considerations to evaluate the impact of disruptions on machine performance and structural integrity. From an engineering perspective, several ST-E1 layout options were analysed to investigate the electromagnetic response of key components under disruption-induced loads, enabling comparison between alternative design solutions. On the physics side, a broad set of disruption scenarios was explored, scanning operational space parameters, plasma-material interactions, and associated thermal loads. Furthermore, the study examined variations in disruption behaviour arising from different reference equilibria, focusing on a range starting from Double Null to Single Null configurations, reflecting the increasing up-down asymmetry consequences. The results reveal significant contrasts in plasma dynamics and structures electromagnetic behaviour between configurations, highlighting the importance of disruption modelling in guiding design choices. These analyses have proven instrumental in shaping ST-E1 development, offering critical insights for mitigating risks and optimising future fusion power plant designs.

Borowiec, Katarzyna [ORNL] (ORCID:0000000335911739↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

The Mu2e Crystal Calorimeter [PowerPoint]

The talk describes the Mu2e experiment, including an introduction on CLFV and the experimental layout, and then covers Mu2e electromagnetic calorimeter, including components, performance and a production status.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic Simulations of Newly Designed Semiconductor Bolometers for Submillimeter Observations

In the frame of the SPICA mission, new semiconductor bolometers have been designed for the POL instrument which is directly part of the HERSCHEL/PACS legacy. These detectors are cooled down to 50 mK and are sensitive to polarization for the 100, 200 and 350 μm wavelength bands. In this paper, 3D simulations have been carried out with the COMSOL Multiphysics software to design the two suspended interlaced silicon spirals which support the orthogonal absorbers (sensitive to the two polarizations) of the POL detectors. These simulations allow to optimize the design of the absorbers and to quantify the cross-polarization. In the last part of this paper, we explain how it is possible to reach the 200 and 350 μm bands from the layout of the 100-μm detector.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Space-time development of electromagnetic and hadronic showers and perspectives for novel calorimetric techniques

The performance of hadronic calorimeters will be a key parameter at the next generation of High Energy Physics accelerators. A detector combining fine granularity with excellent timing information would prove beneficial for the reconstruction of both jets and electromagnetic particles with high energy resolution. In this work, the space and time structure of high energy showers is studied by means of a Geant4-based simulation toolkit. In particular, the relevant time scales of the different physics phenomena contributing to the energy loss are investigated. A correlation between the fluctuations of the energy deposition of high energy hadrons and the time development of the showers is observed, which allows for an event-by-event correction to be computed to improve the energy resolution of the calorimeter. Lastly, these studies are intended to set the basic requirements for the development of a new-concept, total absorption time-imaging calorimeter, which seems now within reach thanks to major technological advancements in the production of fast scintillating materials and compact photodetectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulsed-coil magnet systems for applying uniform 10–30 T fields to centimeter-scale targets on Sandia's Z facility

Sandia has successfully integrated the capability to apply uniform, high magnetic fields (10–30 T) to high energy density experiments on the Z facility. This system uses an 8-mF, 15-kV capacitor bank to drive large-bore (5 cm diameter), high-inductance (1–3 mH) multi-turn, multi-layer electromagnets that slowly magnetize the conductive targets used on Z over several milliseconds (time to peak field of 2–7 ms). This system was commissioned in February 2013 and has been used successfully to magnetize more than 30 experiments up to 10 T that have produced exciting and surprising physics results. These experiments used split-magnet topologies to maintain diagnostic lines of sight to the target. We describe the design, integration, and operation of the pulsed coil system into the challenging and harsh environment of the Z Machine. We also describe our plans and designs for achieving fields up to 20 T with a reduced-gap split-magnet configuration, and up to 30 T with a solid magnet configuration in pursuit of the Magnetized Liner Inertial Fusion concept.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of modelled imaging plates sensitivity to 1-100 keV x-rays and spatial resolution characterisation for diagnostics for the “PETawatt Aquitaine Laser”

Thanks to their high dynamic range and ability to withstand electromagnetic pulse, imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. In the framework of the development of the diagnostics for the Petawatt Aquitaine Laser facility, we present an absolute calibration and spatial resolution study of five different available types of IP (namely, MS-SR-TR-MP-ND) performed by using laser-induced K-shell X-rays emitted by a solid silver target irradiated by the laser ECLIPSE at CEntre Lasers Intenses et Applications. In addition, IP sensitivity measurements were performed with a 160 kV X-ray generator at CEA DAM DIF, where the absolute response of IP SR and TR has been calibrated to X-rays in the energy range 8-75 keV with uncertainties of about 15%. Finally, the response functions have been modeled in Monte Carlo GEANT4 simulations in order to reproduce experimental data. Simulations enable extrapolation of the IP response functions to photon energies from 1 keV to 1 GeV, of interest, e.g., for laser-driven radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NOvA Test Beam Program

NOvA is a long-baseline off-axis beam neutrino experiment at Fermilab and Ash River, Minnesota. By measuring νμ \nu_\mu disappearance and νe \nu_e appearance at the 14 kiloton NOvA Far Detector, the experiment is addressing outstanding questions in neutrino physics, including the neutrino mass hierarchy and existence of leptonic CP violation. The NOvA Test Beam program, under deployment at the Fermilab Test Beam Facility, will use a scaled-down NOvA detector to sample beams of tagged electrons, muons, pions, and protons in the momentum range of 0.3 to 2 GeV/c. It will further the NOvA physics reach by precisely measuring the detector's muon energy scale and electromagnetic and hadronic response, and provide real data for detailed studies of particle identification techniques. Ongoing efforts on beamline instrumentation, data acquisition, simulation, momentum reconstruction and particle identification are presented. Implications for the neutrino oscillation measurements are discussed.

Huang, Junting [Texas U.]↗

Demonstration of the stabilization technique for nonplanar optical resonant cavities utilizing polarization

Based on our previously developed scheme to stabilize nonplanar optical resonant cavities utilizing polarization caused by a geometric phase in electromagnetic waves traveling along a twisted path, we report an application of the technique for a cavity installed in the Accelerator Test Facility, a 1.3-GeV electron beam accelerator at KEK, in which photons are generated by laser-Compton scattering. We successfully achieved a power enhancement of 1200 with 1.4% fluctuation, which means that the optical path length of the cavity has been controlled with a precision of 14 pm under an accelerator environment. In addition, polarization switching utilizing a geometric phase of the nonplanar cavity was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First-Order Individual Gas Sensors as Next Generation Reliable Analytical Instruments

It is conventionally expected that the performance of existing gas sensors may degrade in the field compared to laboratory conditions because (i) a sensor may lose its accuracy in the presence of chemical interferences and (ii) variations of ambient conditions over time may induce sensor-response fluctuations (i.e., drift). Breaking this status quo in poor sensor performance requires understanding the origins of design principles of existing sensors and bringing new principles to sensor designs. Existing gas sensors are single-output (e.g., resistance, electrical current, light intensity, etc.) sensors, also known as zero-order sensors (Karl Booksh and Bruce R. Kowalski, Analytical Chemistry, DOI: 10.1021/ac00087a718). Any zero-order sensor is undesirably affected by variable chemical background and sensor drift that cannot be distinguished from the response to an analyte. To address these limitations, we are developing multivariable gas sensors with independent responses, which are first-order analytical instruments. Here, we demonstrate self-correction against drift in two types of first-order gas sensors that operate in different portions of the electromagnetic spectrum. Our radiofrequency sensors utilize dielectric excitation of semiconducting metal oxide materials on the shoulder of their dielectric relaxation peak and achieve self-correction of the baseline drift by operation at several frequencies. Our photonic sensors utilize nanostructured sensing materials inspired by Morpho butterflies and achieve self-correction of the baseline drift by operation at several wavelengths. These principles of self-correction for drift effects in first-order sensors open opportunities for diverse emerging monitoring applications that cannot afford frequent periodic maintenance that is typical of traditional analytical instruments.

Potyrailo, Radislav A.↗

Performance and characterization of the prototype nm-scale spatial resolution scanning multilayer Laue lenses microscope

Synchrotron based x-ray microscopy established itself as a prominent tool for noninvasive investigations in many areas of science and technology. Many facilities around the world routinely achieve sub-micrometer resolution with a few instruments capable of imaging with the spatial resolution better than 100 nm. With an ongoing effort to push the 2D/3D resolution down to 10 nm in the hard x-ray regime both fabrication of the nano-focusing optics and stability of a microscope become extremely challenging. In this work we present our approach to overcome technical challenges on the path towards high spatial resolution hard x-ray microscopy and demonstrate the performance of a scanning fluorescence microscope equipped with the multilayer Laue lenses focusing optics.

36 MATERIALS SCIENCE↗

Development of a cross-polarization scattering system for the measurement of internal magnetic fluctuations in the DIII-D tokamak

The design and performance of a new cross-polarization scattering (CPS) system for the localized measurement of internal magnetic fluctuations is presented. CPS is a process whereby magnetic fluctuations scatter incident electromagnetic radiation into a perpendicular polarization which is subsequently detected. A new CPS design that incorporates a unique scattering geometry was laboratory tested, optimized, and installed on the DIII-D tokamak. Plasma tests of signal-to-noise, polarization purity, and frequency response indicate proper functioning of the system. CPS data show interesting features related to internal MHD perturbations known as sawteeth that are not observed on density fluctuations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

London Penetration Depth Measurements Using Tunnel Diode Resonators

The London penetration depth λ is the basic length scale for electromagnetic behavior in a superconductor. Precise measurements of λ as a function of temperature, field and impurity scattering have been instrumental in revealing the nature of the order parameter and pairing interactions in a variety of superconductors discovered over the past decades. Here we recount our development of the tunnel-diode resonator technique to measure λ as function of temperature and field in small single crystal samples. Furthermore, we discuss the principles and applications of this technique to study unconventional superconductivity in the copper oxides and other materials such as iron-based superconductors. The technique has now been employed by several groups world-wide as a precision measurement tool for the exploration of new superconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗