A varistor technique to reduce the hazards of electrostatics to electroexplosive devices
Inherent to the design and construction of electroexplosive devices is a vulnerability to inadvertent initiation from electrostatic discharges. The small spacing (approx. 1 mm) between the bridgewire circuits and the body and between bridgewire circuits afford easy breakdown paths for electrostatic voltages. In some cases where metallic component pyrotechnic materials are loaded onto the bridgewire circuits the susceptability to inadvertant initiation is increased. An approach to solving this problem is reported based on the application of a new varistor (nonlinear resistor) material. Certain formulations of metal oxides normally have electrically nonconductive characteristics. However, at selective potentials they become conductive. By proper design and incorporation into electroexplosive devices a variety of breakdown potentials can be achieved. The breakdown potential of the varistor element can be adjusted to meet the requirements of the particular electroexplosive device. The varistor element can also be incorporated in an area isolated from the explosive or pyrotechnic material. Adaptation of this technique to a specific electroexplosive device and the resulting test data are presented.