Identifying Potential Sub-Synchronous Oscillations Using Impedance Scan Approach: Preprint

This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.

control interactions↗

Two-Way Coupled CFD/DEM Simulation of Electromagnetic Heating in a Fluidized Bed Reactor - Extended Abstract

A set of tools has been developed to couple a multiphase reacting computational fluid dynamics solver (MFIX) with two computational electromagnetic solvers (COMSOL and Elmer). In contrast to several recent investigations, which calculate a single static EM field prior to the CFD calculation, in the present work the electromagnetic field is periodically updated during the simulation. This enables the EM field and associated EM heating predictions to reflect the effects of evolving material properties (temperature, composition, size etc.) and the evolving distribution of material in the system. The present work uses effective medium theory (EMT) for the electromagnetic field calculations since the goal is to apply the tool for industrial scale reacting systems. Predictions using MFIX/COMSOL and MFIX/Elmer are compared to in bed thermocouple measurements from a fluidized bed experiment and recent simulation predictions and recent experiments performed at NETL. The NETL experiments also include packed bed operating conditions. Coupled MFIX/COMSOL simulations at these conditions are compared with similar simulations using only COMSOL to measure errors due to the solver coupling approach.

CFD↗

Two-Way Coupled CFD/DEM Simulation of Electromagnetic Heating in a Fluidized Bed Reactor

A set of tools has been developed to couple a multiphase reacting computational fluid dynamics solver (MFIX) with two computational electromagnetic solvers (COMSOL and Elmer). In contrast to several recent investigations, which calculate a single static EM field prior to the CFD calculation, in the present work the electromagnetic field is periodically updated during the simulation. This enables the EM field and associated EM heating predictions to reflect the effects of evolving material properties (temperature, composition, size etc.) and the evolving distribution of material in the system. The present work uses effective medium theory (EMT) for the electromagnetic field calculations since the goal is to apply the tool for industrial scale reacting systems. Predictions using MFIX/COMSOL and MFIX/Elmer are compared to in bed thermocouple measurements from a fluidized bed experiment and recent simulation predictions and recent experiments performed at NETL. The NETL experiments also include packed bed operating conditions. Coupled MFIX/COMSOL simulations at these conditions are compared with similar simulations using only COMSOL to measure errors due to the solver coupling approach.

CFD↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.