Search NASA⌕ Search

SEARCH · Search NASA

Results for “ENG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Next generation of extreme-resolution electron beam lithography

In top down nanofabrication research facilities around the world, the direct-write high-resolution patterning tool of choice is overwhelmingly electron beam lithography. Remarkably small features can be written in a variety of polymeric resists [V. R. Manfrinato et al., Nano Lett. 14, 4406 (2014); V. R. Manfrinato, A. Stein, L. Zhang, Y. Nam, K. G. Yager, E. A. Stach, and C. T. Black, Nano Lett. 17, 4562 (2017)]. However, this technology, which in this article the authors will refer to as conventional electron beam lithography (CEBL), is reaching its practical resolution and precision limits [V. R. Manfrinato et al., Nano Lett. 14, 4406 (2014)]. Hydrogen depassivation lithography (HDL) [J. N. Randall, J. W. Lyding, S. Schmucker, J. R. Von Ehr, J. Ballard, R. Saini, and Y. Ding, J. Vac. Sci. Technol. B 27, 2764 (2009); J. N. Randall, J. B. Ballard, J. W. Lyding, S. Schmucker, J. R. Von Ehr, R. Saini, H. Xu, and Y. Ding, Microelectron. Eng. 87, 955 (2010)] is a different version of electron beam lithography that is not limited in resolution and precision in the way that CEBL is. It uses a cold field emitter, a scanning tunneling microscope (STM) tip, to deliver a small spot of electrons on a Si (100) 2 × 1 H-passivated surface to expose a self-developing resist that is a monolayer of H adsorbed to the Si surface. Subnanometer features [S. Chen, H. Xu, K. E. J. Goh, L. Liu, and J. N. Randall, Nanotechnology 23, 275301 (2012)], and even the removal of single H atoms can be routinely accomplished [M. A. Walsh and M. C. Hersam, Annu. Rev. Phys. Chem. 60, 193 (2009)]. It is known that the H desorption process at low biases is a multielectron process [E. Foley, A. Kam, J. Lyding, and P. Avouris, Phys. Rev. Lett. 80, 1336 (1998)], but the tunneling distribution of the electrons from the STM tip to the Si surface lattice is not known. The authors have developed a simple model that demonstrates that the combination of two highly nonlinear processes creates a much higher contrast exposure mechanism than CEBL. Currently, HDL has been used almost exclusively on the Si (100) surface and has a limited number of pattern transfer techniques including Si and Ge patterned epitaxy, selective atomic layer deposition of TiO2 followed by reactive ion etching [J. B. Ballard, T. W. Sisson, J. H. G. Owen, W. R. Owen, E. Fuchs, J. Alexander, J. N. Randall, and J. R. Von Ehr, J. Vac. Sci. Technol. B 31, 06FC01 (2013)], and selective deposition of dopant atoms for quantum devices and materials [Workshop on 2D Quantum MetaMaterials held at NIST, Gaithersburg, MD, April 25–26, 2018, edited by J. Owen and W. P. Kirk]. While the throughput of HDL is very low, going parallel in a big way appears promising [J. N. Randall, J. H. G. Owen, J. Lake, R. Saini, E. Fuchs, M. Mahdavi, S. O. R. Moheimani, and B. C. Schaefer, J. Vac. Sci. Technol. B 36, 6 (2018)]. However, the most exciting aspect of HDL is its atomic-scale resolution and precision, which is key to nanoscale research. The authors see HDL emerging as the ultimate high-resolution patterning tool in top down nanofabrication research facilities.

42 ENGINEERING↗

Directional fractal signature methods for trabecular bone texture in hand radiographs: Data from the Osteoarthritis Initiative

Purpose: To develop directional fractal signature methods for the analysis of trabecular bone (TB) texture in hand radiographs. Problems associated with the small size of hand bones and the orientation of fingers were addressed. Methods: An augmented variance orientation transform (AVOT) and a quadrant rotating grid (QRG) methods were developed. The methods calculate fractal signatures (FSs) in different directions. Unlike other methods they have the search region adjusted according to the size of bone region of interest (ROI) to be analyzed and they produce FSs defined with respect to any chosen reference direction, i.e., they work for arbitrary orientation of fingers. Five parameters at scales ranging from 2 to 14 pixels (depending on image size and method) were derived from rose plots of Hurst coefficients, i.e., FS in dominating roughness (FS{sub Sta}), vertical (FS{sub V}) and horizontal (FS{sub H}) directions, aspect ratio (StrS), and direction signatures (StdS), respectively. The accuracy in measuring surface roughness and isotropy/anisotropy was evaluated using 3600 isotropic and 800 anisotropic fractal surface images of sizes between 20 × 20 and 64 × 64 pixels. The isotropic surfaces had FDs ranging from 2.1 to 2.9 in steps of 0.1, and the anisotropic surfaces had two dominating directions of 30° and 120°. The methods were used to find differences in hand TB textures between 20 matched pairs of subjects with (cases: approximate Kellgren-Lawrence (KL) grade ≥2) and without (controls: approximate KL grade <2) radiographic hand osteoarthritis (OA). The OA Initiative public database was used and 20 × 20 pixel bone ROIs were selected on 5th distal and middle phalanges. The performance of the AVOT and QRG methods was compared against a variance orientation transform (VOT) method developed earlier [M. Wolski, P. Podsiadlo, and G. W. Stachowiak, “Directional fractal signature analysis of trabecular bone: evaluation of different methods to detect early osteoarthritis in knee radiographs,” Proc. Inst. Mech. Eng., Part H 223, 211–236 (2009)]. Results: The AVOT method correctly quantified the isotropic and anisotropic surfaces for all image sizes and scales. Values of FS{sub Sta} were significantly different (P < 0.05) between the isotropic surfaces. Using the VOT and QRG methods no differences were found at large scales for the isotropic surfaces that are smaller than 64 × 64 and 48 × 48 pixels, respectively, and at some scales for the anisotropic surfaces with size 48 × 48 pixels. Compared to controls, using the AVOT and QRG methods the authors found that OA TB textures were less rough (P < 0.05) in the dominating and horizontal directions (i.e., lower FS{sub Sta} and FS{sub H}), rougher in the vertical direction (i.e., higher FS{sub V}) and less anisotropic (i.e., higher StrS) than controls. No differences were found using the VOT method. Conclusions: The AVOT method is well suited for the analysis of bone texture in hand radiographs and it could be potentially useful for early detection and prediction of hand OA.

60 APPLIED LIFE SCIENCES↗

Experimental demonstration of passive acoustic imaging in the human skull cavity using CT-based aberration corrections

Purpose: Experimentally verify a previously described technique for performing passive acoustic imaging through an intact human skull using noninvasive, computed tomography (CT)-based aberration corrections Jones et al. [Phys. Med. Biol. 58, 4981–5005 (2013)]. Methods: A sparse hemispherical receiver array (30 cm diameter) consisting of 128 piezoceramic discs (2.5 mm diameter, 612 kHz center frequency) was used to passively listen through ex vivo human skullcaps (n = 4) to acoustic emissions from a narrow-band fixed source (1 mm diameter, 516 kHz center frequency) and from ultrasound-stimulated (5 cycle bursts, 1 Hz pulse repetition frequency, estimated in situ peak negative pressure 0.11–0.33 MPa, 306 kHz driving frequency) Definity™ microbubbles flowing through a thin-walled tube phantom. Initial in vivo feasibility testing of the method was performed. The performance of the method was assessed through comparisons to images generated without skull corrections, with invasive source-based corrections, and with water-path control images. Results: For source locations at least 25 mm from the inner skull surface, the modified reconstruction algorithm successfully restored a single focus within the skull cavity at a location within 1.25 mm from the true position of the narrow-band source. The results obtained from imaging single bubbles are in good agreement with numerical simulations of point source emitters and the authors’ previous experimental measurements using source-based skull corrections O’Reilly et al. [IEEE Trans. Biomed. Eng. 61, 1285–1294 (2014)]. In a rat model, microbubble activity was mapped through an intact human skull at pressure levels below and above the threshold for focused ultrasound-induced blood–brain barrier opening. During bursts that led to coherent bubble activity, the location of maximum intensity in images generated with CT-based skull corrections was found to deviate by less than 1 mm, on average, from the position obtained using source-based corrections. Conclusions: Taken together, these results demonstrate the feasibility of using the method to guide bubble-mediated ultrasound therapies in the brain. The technique may also have application in ultrasound-based cerebral angiography.

60 APPLIED LIFE SCIENCES↗

The Target-Matrix Optimization Paradigm for High-Order Meshes

Here, we describe a framework for controlling and improving the quality of high-order finite element meshes based on extensions of the Target-Matrix Optimization Paradigm (TMOP) of [P. Knupp, Eng. Comput., 28 (2012), pp. 419--429]. This approach allows high-order applications to have a very precise control over local mesh quality, while still improving the mesh globally. We address the adaption of various TMOP components to the settings of general isoparametric element mappings, including the mesh quality metric in 2D and 3D, the selection of sample points and the solution of the resulting mesh optimization problem. We also investigate additional practical concerns, such as tangential relaxation and restricting the deviation from the original mesh. The benefits of the new high-order TMOP algorithms are illustrated on a number of test problems and examples from a high-order arbitrary Lagrangian--Eulerian (ALE) application [BLAST: High-order curvilinear finite elements for shock hydrodynamics, http://www.llnl.gov/CASC/blast]. Our implementation is freely available in an open-source library form [MFEM: Modular parallel finite element methods library, http://mfem.org].

97 MATHEMATICS AND COMPUTING↗

Single-neutron adding on $^{34}$S

For this work, single-neutron adding data was collected in order to determine the distribution of the single-neutron strength of the 0ƒ 7/2 , 1p 3/2 , 1p 1/2 and 0ƒ 5/2 orbitals outside of Z = 16, N = 18, 34 S. The 34 S(d,p) 35 S reaction has been measured at 8 MeV/u to investigate cross sections to excited states in 35 S. Outgoing proton yields and momenta were analyzed by the Super-Enge Split-Pole Spectrograph in conjunction with the CeBrA demonstrator located at the John D. Fox Laboratory at Florida State University. Angular distributions were compared with Distorted Wave Born Approximation calculations in order to extract single-neutron spectroscopic overlaps. Spectroscopic overlaps and strengths were determined for states in S up through 6 MeV in excitation energy. Each orbital was observed to have fragmented strength where a single level carried the majority. The single-neutron centroids of the 0ƒ 7/2 , 1p 3/2 , 1p 1/2 and 0ƒ 5/2 orbitals were determined to be 2360$^{+90}_{-40}$ keV, 3280$^{+80}_{-50}$ keV, 4780$^{+60}_{-40}$ keV, and ≳7500 keV, respectively. A previous discrepancy in the literature with respect to the distribution of the neutron 1p 1/2 strength was resolved. The integration of the normalized spectroscopic strengths, up to 5.1 MeV in excitation energy, revealed fully-vacant occupancies for the 0ƒ 7/2 , 1p 3/2 , and 1p 1/2 orbitals, as expected. The spacing in the single-neutron energies highlighted a reduction in the traditional N = 28 shell-gap, relative to both the 1p spin-orbit energy difference (N = 32) and the lower limit on the N = 34 shell spacing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hypernuclear spectroscopy with electron beam at JLab Hall C

Hypernuclear spectroscopy with electron beam at JLab Hall C has been studied since 2000. The first experiment, JLab E89-009, used Short Orbit Spectrometer (SOS) as a kaon arm and a split-pole type spectrometer (ENGE) as an electron arm. E89-009 employed zero-degree tagging method, which tags scattered electrons at zero-degree and the kaon arm also covered zero-degree. This method obtains maximum yield of hypernuclei but sufferers from high rate background of electrons from bremsstrahlung and positrons from pair-creation. Nevertheless, this experiment demonstrated the possibility of the (e,e' K{sup +}) reaction for hypernuclear spectroscopy by obtaining a hypernuclear mass spectrum with an energy resolution of better than 1 MeV (FWHM) [1][2]. However, poor signal to noise ratio and poor statistics requires us to improve the experimental setup. Therefore, E01-011 experiment was proposed based on the success of the JLab E01-011 experiment. Improvements of E01-011 from E09-009 can be summarized as: 1. Employed newly constructed high resolution kaon spectrometer (HKS) as a kaon arm. 2. Employed so-called 'tilt-method' for the electron arm. With the newly constructed HKS, having 2-10-4 momentum resolution, we expect an energy resolution of 400 keV (FWHM). The 'tilt-method' means the electron arm is tilted vertically to the splitter dispersive plane to avoid background electrons from bremsstrahlung and moeller scattering. The setup allowed us to use up to a few tens beam. The experiment was performed in 2005 and final result will be shown shortly. The third experiment, JLab E05-115 experiment was proposed as a natural extension of E01-011 experiment and will be performed in 2009. Improvements of experimental setup are, 1. Employed newly constructed high resolution electron spectrometer (HES) as a electron arm, 2. Employed a new charge-separation magnet (Splitter), fully customized for hypernuclear experiment at Hall C. With the third generation experimental setup, we can study variety of targets up to medium-heavy ones such as {sup 52}Cr. This talk mainly focuses on the current status of the E05-115 experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spherical nanoindentation stress-strain analysis, Version 1

Nanoindentation is a tool that allows the mechanical response of a variety of materials at the nano to micron length scale to be measured. Recent advances in spherical nanoindentation techniques have allowed for a more reliable and meaningful characterization of the mechanical response from nanoindentation experiments in the form on an indentation stress-strain curve. This code base, Spin, is written in MATLAB (The Mathworks, Inc.) and based on the analysis protocols developed by S.R. Kalidindi and S. Pathak [1, 2]. The inputs include the displacement, load, harmonic contact stiffness, harmonic displacement, and harmonic load from spherical nanoindentation tests in the form of an Excel (Microsoft) spreadsheet. The outputs include indentation stress-strain curves and indentation properties as well their variance due to the uncertainty of the zero-point correction in the form of MATLAB data (.mat) and figures (.png). [1] S. Pathak, S.R. Kalidindi. Spherical nanoindentation stress–strain curves, Mater. Sci. Eng R-Rep 91 (2015). [2] S.R. Kalidindi, S. Pathak. Determination of the effective zero-point and the extraction of spherical nanoindentation stress-strain curves, Acta Materialia 56 (2008) 3523-3532.

Weaver, JordanS.↗

Safety-Related Instrumentation and Control Upgrade Pilot Project: NUREG- 0711 Process Development, Planning and Analysis Activities, and Lessons Learned

Constellation Energy and the United States Department of Energy (DOE) have established a public/private partnership to implement a pilot digital upgrade to replace legacy analog, safety-related reactor protection and emergency safety feature actuation systems (RPS/ESFAS) with modern digital systems. This effort is occurring at Constellation’s Limerick Generating Station. This project is being performed in accordance with industry processes that have been adapted to better support digital upgrades. These processes include IP-ENG-001, Standard Design Process, NISP-EN-04, Standard Digital Engineering Process and Electric Power Research Institute Report 3002011816, Digital Engineering Guide. The Light Water Reactor Sustainability (LWRS) Program at the Idaho National Laboratory (INL) has been supporting this effort. Latest INL HFE efforts in support of this project have focused on definition and implementation of the Human Factors Engineering (HFE) Program in support of Constellation design and related licensing efforts. This paper presents the development execution of the HFE Program through completion of the Planning and Analysis Phase as defined by NUREG-0711 as well as HFE lessons learned.

99 GENERAL AND MISCELLANEOUS↗

Effect of slope errors on the performance of mirrors for x-ray free electron laser applications

In this work we point out that slope errors play only a minor role in the performance of a certain class of x-ray optics for X-ray Free Electron Laser (XFEL) applications. Using physical optics propagation simulations and the formalism of Church and Takacs [Opt. Eng. 34, 353 (1995)], we show that diffraction limited optics commonly found at XFEL facilities posses a critical spatial wavelength that makes them less sensitive to slope errors, and more sensitive to height error. Given the number of XFELs currently operating or under construction across the world, we hope that this simple observation will help to correctly define specifications for x-ray optics to be deployed at XFELs, possibly reducing the budget and the timeframe needed to complete the optical manufacturing and metrology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technical Report-Rare Earth Element Concentrations in Wyoming's Produced Waters

This study is a joint effort by the University of Wyoming (UW), the UW Engineering Department (UW-ENG), and Idaho National Laboratories (INL) and the United States Geological Survey (USGS) to describe rare earth element concentrations in oil and gas produced waters. In this work we present the Rare Earth Element (REE) and trace metal character of produced water in several oil and gas fields and three coal fired power stations.

15 GEOTHERMAL ENERGY↗

Triton Field Trials Changes in Habitat 360-degree Underwater Videos

This dataset contains the underwater 360-degree video files recorded with a Boxfish 360 camera in La Jolla, CA, near a gravity base anchor of the CalWave xWave wave energy converter in December 2021 over three days, at dawn, noon, and dusk. It was generated to test the ability of using this type of camera mounted on an aluminum frame as a video lander to monitor the artificial reef effect of marine energy devices and associated seafloor structures. The Boxfish 360 is made of 3 cameras each recording its own set of videos. The videos are MOV files that can be viewed individually with any video reader but need to be stitched together to create the 360-degree footage. This dataset contains all the raw video files collected at dawn, noon and dusk on 11/30/2021, 12/01/2021 and 12/02/2021, for about 1h each time. This dataset is associated with the journal manuscript below (linked in resources): Hemery, L.G.; Mackereth, K.F.; Gunn, C.M.; Pablo, E.B. Use of a 360-Degree Underwater Camera to Characterize Artificial Reef and Fish Aggregating Effects around Marine Energy Devices. J. Mar. Sci. Eng. 2022, 10, 555. https://doi.org/10.3390/jmse10050555

16 TIDAL AND WAVE POWER↗

Optimization of a cyclone using MFIX and Nodeworks

Video depicting the optimization process of a cyclone on NETL's chemical looping reactor (CLR) using MFIX and Nodeworks. MFIX is used to model the cyclone using PIC. Nodeworks is then used to generate proposed geometry changes using a Latin hypercube. Each design is simulated, with an objective value being computed based on the cyclone efficiency and pressure drop. A Gaussian Process surrogate model is then constructed from the objective values. This surrogate model is then used by a differential evolution optimization algorithm to identify the optimal cyclone design. Details published here: Weber, J., Fullmer, W., Gel, A., and Musser, J. (February 4, 2020). "Optimization of a Cyclone Using Multiphase Flow Computational Fluid Dynamics." ASME. J. Fluids Eng. March 2020; 142(3): 031111. https://doi.org/10.1115/1.4045952 OSTI: https://www.osti.gov/pages/servlets/purl/1763893

cyclone↗

Simple intrinsic defects in GaAs: numerical supplement

This Report presents numerical tables summarizing properties of intrinsic defects in gallium arsenide, GaAs, as computed by density functional theory. This Report serves as a numerical supplement to the results published in: P.A. Schultz and O.A. von Lilienfeld, 'Simple intrinsic defects in GaAs', Modelling Simul. Mater. Sci Eng., Vol. 17, 084007 (2009), and intended for use as reference tables for a defect physics package in device models. The numerical results for density functional theory calculations of properties of simple intrinsic defects in gallium arsenide are presented.

74 ATOMIC AND MOLECULAR PHYSICS↗

PINS-3X Operations

Idaho National Laboratory’s (INL’s) Portable Isotopic Neutron Spectroscopy System (PINS) non-intrusively identifies the chemical fill of munitions and sealed containers. The PINS-3X variant of the system is used to identify explosives and uses a deuterium-tritium (DT) electronic neutron generator (ENG) as the neutron source. Use of the system, including possession and use of the neutron generator and shipment of the system components requires compliance with a number of regulations. This report outlines some of these requirements as well as some of the requirements in using the system outside of INL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Techniques for Nuclear Systems - Theory Lectures

These are lecture notes for a Monte Carlo class given at the University of New Mexico. The following topics are covered: course information; nuclear eng. review & MC; random numbers and sampling; computational geometry; collision physics; tallies and statistics; eigenvalue calculations I; eigenvalue calculations II; eigenvalue calculations III; variance reduction; parallel Monte Carlo; parameter studies; fission matrix and higher eigenmodes; doppler broadening; Monte Carlo depletion; HTGR modeling; coupled MC and T/H calculations; fission energy deposition. Solving particle transport problems with the Monte Carlo method is simple - just simulate the particle behavior. The devil is in the details, however. These lectures provide a balanced approach to the theory and practice of Monte Carlo simulation codes. The first lectures provide an overview of Monte Carlo simulation methods, covering the transport equation, random sampling, computational geometry, collision physics, and statistics. The next lectures focus on the state-of-the-art in Monte Carlo criticality simulations, covering the theory of eigenvalue calculations, convergence analysis, dominance ratio calculations, bias in Keff and tallies, bias in uncertainties, a case study of a realistic calculation, and Wielandt acceleration techniques. The remaining lectures cover advanced topics, including HTGR modeling and stochastic geometry, temperature dependence, fission energy deposition, depletion calculations, parallel calculations, and parameter studies. This portion of the class focuses on using MCNP to perform criticality calculations for reactor physics and criticality safety applications. It is an intermediate level class, intended for those with at least some familiarity with MCNP. Class examples provide hands-on experience at running the code, plotting both geometry and results, and understanding the code output. The class includes lectures & hands-on computer use for a variety of Monte Carlo calculations. Beginning MCNP users are encouraged to review LA-UR-09-00380, "Criticality Calculations with MCNP: A Primer (3nd Edition)" (available at http:// mcnp.lanl.gov under "Reference Collection") prior to the class. No Monte Carlo class can be complete without having students write their own simple Monte Carlo routines for basic random sampling, use of the random number generator, and simplified particle transport simulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Standard High Solids Vessel Design De-inventory Simulant Qualification

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is working to develop a Standard High Solids Vessel Design (SHSVD) process vessel. To support testing of this new design, WTP engineering staff requested that a Newtonian simulant be developed that would represent the de-inventory (residual high-density tank solids cleanout) process. Its basis and target characteristics are defined in 24590-WTP-ES-ENG-16-021 and implemented through PNNL Test Plan TP-WTPSP-132 Rev. 1.0. This document describes the de-inventory Newtonian carrier fluid (DNCF) simulant composition that will satisfy the basis requirement to mimic the density (1.18 g/mL ± 0.1 g/mL) and viscosity (2.8 cP ± 0.5 cP) of 5 M NaOH at 25 °C.1 The simulant viscosity changes significantly with temperature. Therefore, various solution compositions may be required, dependent on the test stand process temperature range, to meet these requirements. Table ES.1 provides DNCF compositions at selected temperatures that will meet the density and viscosity specifications as well as the temperature range at which the solution will meet the acceptable viscosity tolerance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Filter Aerosol Measurements for ARM

The goal of this study was to determine the best filter media for use in ARM PSAPs following the manufacturer discontinuation of the current filter media. The study comprised by multiple experiments to assess four potential replacement filter medium relative to the Pallflex E-70, which is being discontinued, and is documented in ARM ServiceNow under ENG0003846. The experiments laid out in the document ‘180504 Filter Aerosol Measurements for ARM.docx’ and several subsequent tests suggest that the Pallflex Emfab media is the best candidate for ongoing ARM filter-based absorbance measurements. Other media were ruled out based on particle-capture efficiency for small particles. In tests with Nigrosin, EMFAB exceeded all other media. Tests were done measuring reported absorbance for all media in Particle Soot Absorption Photometers (PSAPs) operated in parallel sampling under several conditions: ambient air, 3 sizes of black-dyed PSL (Poly Styrene Latex) spheres, and Nigrosin particles. These tests indicate a different factor of reported absorbance for each media relative to the original Pallflex E70 filter. The factor for the Azumi media was consistent with unpublished work by Ogren (NOAA). The tests described here were not exhaustive and were complicated by time-varying differences among the PSAPs used. However, it is concluded that they are sufficient to justify ARM switching to Emfab filter media for future ARM PSAP measurements. The remaining store of E70 will be reserved to quantitatively characterize differences between Emfab and E70 (and Azumi?) in both laboratory and field side-by-side tests as put forth in a succeeding ENG. This future work will empirically identify correction factors applicable to Emfab and quantify the uncertainty in comparing the historical E70 measurements with ongoing Emfab measurements. Comparison of PSAP measurements with an independent absolute ‘reference’ for aerosol absorbance, i.e., PhotoThermal Interferometry or difference measurements of Cavity Attenuated Phase Shift extinction (CAPS) minus Nephelometry scattering would be valuable but exceed the scope of ARM Infrastructure. While the characterization of correction factors is required for maintaining and improving accuracy in future absorption measurements, it was beyond the scope of the current study.

54 ENVIRONMENTAL SCIENCES↗

Filter Aerosol Measurements for ARM

The goal of this study was to determine the best filter media for use in Atmospheric Radiation Measurement (ARM) particle soot absorption photometers (PSAPs) following the manufacturer discontinuation of the current filter media. The study comprised multiple experiments to assess four potential replacement filter medium relative to the Pallflex E-70, which is being discontinued, and is documented in ARM’s ServiceNow system under ENG0003846. The experiments laid out in the document ‘180504 Filter Aerosol Measurements for ARM.docx’ and several subsequent tests suggest that the Pallflex Emfab media is the best candidate for ongoing ARM filter-based absorbance measurements. Other media were ruled out based on particle capture efficiency for small particles. In tests with Nigrosin, Emfab exceeded all other media. Tests were done measuring reported absorbance for all media in PSAPs operated in parallel sampling under several conditions: ambient air, three sizes of black-dyed PSL (polystyrene latex) spheres, and Nigrosin particles. These tests indicate a different factor of reported absorbance for each media relative to the original Pallflex E70 filter. The factor for the Azumi media was consistent with unpublished work by Ogren (National Oceanic and Atmospheric Administration [NOAA]). The tests described here were not exhaustive and were complicated by time-varying differences among the PSAPs used. However, it is concluded that they are sufficient to justify ARM switching to Emfab filter media for future ARM PSAP measurements. The remaining store of E70 will be reserved to quantitatively characterize differences between Emfab and E70 (and Azumi?) in both laboratory and field side-by-side tests as put forth in a succeeding ENG. This future work will empirically identify correction factors applicable to Emfab and quantify the uncertainty in comparing the historical E70 measurements with ongoing Emfab measurements. Comparison of PSAP measurements with an independent absolute ‘reference’ for aerosol absorbance, i.e., photo thermal interferometry or difference measurements of cavity attenuated phase shift extinction (CAPS) minus nephelometry scattering, would be valuable but exceed the scope of ARM Infrastructure. While the characterization of correction factors is required for maintaining and improving accuracy in future absorption measurements, it was beyond the scope of the current study.

aerosol observing system↗