Search NASA⌕ Search

SEARCH · Search NASA

Results for “ERROR SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Quantitative assessment of fitting errors associated with streak camera noise in Thomson scattering data analysis

Thomson scattering measurements in high energy density experiments are often recorded using optical streak cameras. In the low-signal regime, noise introduced by the streak camera can become an important and sometimes the dominant source of measurement uncertainty. In this paper, we present a formal method of accounting for the presence of streak camera noise in our measurements. We present a phenomenological description of the noise generation mechanisms and present a statistical model that may be used to construct the covariance matrix associated with a given measurement. This model is benchmarked against simulations of streak camera images. We demonstrate how this covariance may then be used to weight fitting of the data and provide quantitative assessments of the uncertainty in the fitting parameters determined by the best fit to the data and build confidence in the ability to make statistically significant measurements in the low-signal regime, where spatial correlations in the noise become apparent. These methods will have general applicability to other measurements made using optical streak cameras.

47 OTHER INSTRUMENTATION↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

EXPRES. II. Searching for Planets around Active Stars: A Case Study of HD 101501

By controlling instrumental errors to below 10 cm s{sup −1}, the EXtreme PREcision Spectrograph (EXPRES) allows for a more insightful study of photospheric velocities that can mask weak Keplerian signals. Gaussian processes (GP) have become a standard tool for modeling correlated noise in radial velocity data sets. While GPs are constrained and motivated by physical properties of the star, in some cases they are still flexible enough to absorb unresolved Keplerian signals. We apply GP regression to EXPRES radial velocity measurements of the 3.5 Gyr old chromospherically active Sun-like star, HD 101501. We obtain tight constraints on the stellar rotation period and the evolution of spot distributions using 28 seasons of ground-based photometry, as well as recent Transiting Exoplanet Survey Satellite data. Light-curve inversion was carried out on both photometry data sets to reveal the spot distribution and spot evolution timescales on the star. We find that the >5 m s{sup −1} rms radial velocity variations in HD 101501 are well modeled with a GP stellar activity model without planets, yielding a residual rms scatter of 45 cm s{sup −1}. We carry out simulations, injecting and recovering signals with the GP framework, to demonstrate that high-cadence observations are required to use GPs most efficiently to detect low-mass planets around active stars like HD 101501. Sparse sampling prevents GPs from learning the correlated noise structure and can allow it to absorb prospective Keplerian signals. We quantify the moderate to high-cadence monitoring that provides the necessary information to disentangle photospheric features using GPs and to detect planets around active stars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing time integration for accurate recovery of shockwave interface location in radiography

We present simulations and experiments of time integrated radiographic imaging of a moving 1D shock wave front and a quantitative method for determining the statistical error in locating the shock front as a function of integration time and noise in the radiograph. We discuss the trade-off between increasing motion blur, which leads to decreased shock front location certainty, and increasing signal-to-noise, which leads to improved image quality with increasing integration time. We find an optimum integration time between a short integration time, where noise limits the error, and a long integration time, where motion blurring limits the error. This methodology can be used to tune experimental configurations to obtain the highest quality radiograph for a given experimental configuration.

Bremsstrahlung↗

Stochastic Optimization and Uncertainty Quantification of Natrium-based Nuclear-Renewable Energy Systems for Flexible Power Applications in Deregulated Markets

Rapid integration of variable renewable energy sources (VRES) has made modeling and stochastic optimization of hybrid energy systems crucial for studying their long-term performance and viability. However, most studies have focused on just historical data, which may be unreliable for capturing short-term fluctuations, rare events, and long-term patterns of energy demand, price, and the variability of renewable energy sources. For this study, optimal synthetic time series models were developed using Wasserstein distance. The models were validated by comparing the key statistical measures against those of the historical data. They were then used to optimize the integrated Natrium-style advanced energy systems and their long-term (30 years) economics. The stochastic model performs bi-level optimization to find the optimal sizes for the balance of plant and thermal energy storage, while also optimizing energy dispatch to achieve the maximum net present value. In studies of two deregulated markets (California ISO and the Electric Reliability Council of Texas), the integrated Natrium-style system performed better in CAISO than in ERCOT, given higher and more consistent electricity prices during peak-demand periods. The potentially enlarged cost associated with the variable operation and maintenance of the TES system also plays a significant role in driving the system sizing, thus its impacts on the system are investigated in detail through comparison against a baseline case. The study also finds that the bi-level optimization results based on stochastic gradient descent closely match the grid search results. The uncertainty quantification of the stochastic signals provides further NPV-related insights and probability distributions for the case studies. The normal standard error of the mean of NPV for the case with and without TES VOM for CAISO were found to be 7.73M (plus-minus sign) 1.09M USD and 104.99M (plus-minus sign) 1.25M USD, respectively based on a 95% confidence. Given the relatively small NPV variance based on 150 samples, the analysis affords the most robust possible prediction of the techno-economic performance of the integrated Natrium-style energy systems.

25 ENERGY STORAGE↗

Electron shelving of a superconducting artificial atom

Interfacing long-lived qubits with propagating photons is a fundamental challenge in quantum technology. Cavity and circuit quantum electrodynamics (cQED) architectures rely on an off-resonant cavity, which blocks the qubit emission and enables a quantum non-demolition (QND) dispersive readout. However, no such buffer mode is necessary for controlling a large class of three-level systems that combine a metastable qubit transition with a bright cycling transition, using the electron shelving effect. Here we demonstrate shelving of a circuit atom, fluxonium, placed inside a microwave waveguide. With no cavity modes in the setup, the qubit coherence time exceeds 50 μs, and the cycling transition’s radiative lifetime is under 100 ns. By detecting a homodyne fluorescence signal from the cycling transition, we implement a QND readout of the qubit and account for readout errors using a minimal optical pumping model. Our result establishes a resource-efficient (cavityless) alternative to cQED for controlling superconducting qubits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lensing without borders – I. A blind comparison of the amplitude of galaxy–galaxy lensing between independent imaging surveys

ABSTRACT Lensing without borders is a cross-survey collaboration created to assess the consistency of galaxy–galaxy lensing signals (ΔΣ) across different data sets and to carry out end-to-end tests of systematic errors. We perform a blind comparison of the amplitude of ΔΣ using lens samples from BOSS and six independent lensing surveys. We find good agreement between empirically estimated and reported systematic errors which agree to better than 2.3σ in four lens bins and three radial ranges. For lenses with zL > 0.43 and considering statistical errors, we detect a 3–4σ correlation between lensing amplitude and survey depth. This correlation could arise from the increasing impact at higher redshift of unrecognized galaxy blends on shear calibration and imperfections in photometric redshift calibration. At zL > 0.54, amplitudes may additionally correlate with foreground stellar density. The amplitude of these trends is within survey-defined systematic error budgets that are designed to include known shear and redshift calibration uncertainty. Using a fully empirical and conservative method, we do not find evidence for large unknown systematics. Systematic errors greater than 15 per cent (25 per cent) ruled out in three lens bins at 68 per cent (95 per cent) confidence at z < 0.54. Differences with respect to predictions based on clustering are observed to be at the 20–30 per cent level. Our results therefore suggest that lensing systematics alone are unlikely to fully explain the ‘lensing is low’ effect at z < 0.54. This analysis demonstrates the power of cross-survey comparisons and provides a promising path for identifying and reducing systematics in future lensing analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

The stellar parameters and elemental abundances from low-resolution spectra – I. 1.2 million giants from LAMOST DR8

As a typical data-driven method, deep learning becomes a natural choice for analysing astronomical data. In this study, we built a deep convolutional neural network (NN) to estimate basic stellar parameters $T\rm {_{eff}}$, log g , metallicity ([M/H] and [Fe/H]) and [α/M] along with nine individual elemental abundances ([C/Fe], [N/Fe], [O/Fe], [Mg/Fe], [Al/Fe], [Si/Fe], [Ca/Fe], [Mn/Fe], and [Ni/Fe]). The NN is trained using common stars between the APOGEE survey and the LAMOST survey. We used low-resolution spectra from LAMOST survey as input, and measurements from APOGEE as labels. For stellar spectra with the signal-to-noise ratio in g band larger than 10 in the test set, the mean absolute error (MAE) is 29 K for $T\rm {_{eff}}$, 0.07 dex for log g , 0.03 dex for both [Fe/H] and [M/H], and 0.02 dex for [α/M]. The MAE of most elements is between 0.02 and 0.04 dex. The trained NN was applied to 1210 145 giants, including sub-giants, from LAMOST DR8 within the range of stellar parameters 3500 K < $T\rm {_{eff}}$ < 5500 K, 0.0 dex < log g < 4.0 dex, −2.5 dex < [Fe/H] < 0.5 dex. The distribution of our results in the chemical spaces is highly consistent with APOGEE labels and stellar parameters show consistency with external high-resolution measurements from GALAH. The results in this study allow us to further studies based on LAMOST data and deepen our understanding of the accretion and evolution history of the Milky Way. The electronic version of the value added catalog is available at http://www.lamost.org/dr8/v1.1/doc/vac.

79 ASTRONOMY AND ASTROPHYSICS↗

Hyper Suprime-Cam Year 3 results: Cosmology from cosmic shear two-point correlation functions

Here, we perform a blinded cosmology analysis with cosmic shear two-point correlation functions measured from more than 25 million galaxies in the Hyper Suprime-Cam three-year shear catalog in four tomographic redshift bins ranging from 0.3 to 1.5. After conservative masking and galaxy selection, the survey covers 416 deg 2 of the northern sky with an effective galaxy number density of 15 arcmin –2 over the four redshift bins. The 2PCFs adopted for cosmology analysis are measured in the angular range; 7.1 <θ/arcmin < 56.6 for ξ + and 31.2 < θ/arcmin < 248 for ξ – , with a total signal-to-noise ratio of 26.6. We apply a conservative, wide, flat prior on the photometric redshift errors on the last two tomographic bins, and the relative magnitudes of the cosmic shear amplitude across four redshift bins allow us to calibrate the photometric redshift errors. With this flat prior on redshift errors, we find Ω m = 0.25⁢6$^{+0.056}_{–0.044}$ and S 8 ≡ σ 8 ⁢$\sqrt{Ω_{m}/0.3}$ = 0.76⁢9$^{+0.031}_{–0.034}$ (both 68% C.I.) for a flat Λ cold dark matter cosmology. We find, after unblinding, that our constraint on S 8 is consistent with the Fourier space cosmic shear and the 3 × 2 pt analyses on the same HSC dataset. We carefully study the potential systematics from astrophysical and systematic model uncertainties in our fiducial analysis using synthetic data, and report no biases (including projection bias in the posterior space) greater than 0.5σ in the estimation of S 8 . Our analysis hints that the mean redshifts of the two highest tomographic bins are higher than initially estimated. In addition, a number of consistency tests are conducted to assess the robustness of our analysis. Comparing our result with Planck-2018 cosmic microwave background observations, we find a ~2σ tension for the Λ ⁢CDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]↗

Wave Measurements Using Multi-Frame Processing of Marine Radar Data

Marine radars have proven to be useful for measuring ocean waves, but the accuracy of the measurements is limited by several factors including the look-angle dependence of the radar signals as well as noise in the radar data. The look-angle dependence introduces a systematic error or bias in the measurements, and noise causes a random error. This paper describes a method of combining data from multiple radar frames that is optimal in the sense of minimizing the error for a set of biased measurements with random additive noise. The results are shown experimentally to increase the correlation of the radar estimates with buoy measurements.

47 OTHER INSTRUMENTATION↗

DETAIL Component Scaling and Methodology Comparison

The purpose of this study was to develop a process to convert input signals from one facility into another by reflecting geometric and environmental settings. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is a research facility in development. Its aim is to emulate the daily interactions among power production industry systems and receive real-time data from those systems as inputs. To convert signals and ensure that the temporal sequences and magnitudes reflect laboratory settings, the ability to scale and project data is essential. To demonstrate this ability, Dynamical System Scaling (DSS) and Hierarchical Two-Tiered Scaling (H2TS) (methodologies that enable systems to scale and project or extrapolate data sets to desired environments while conserving the observed behavior based on first principles) were applied to DETAIL’s thermocline thermal storage system in the Thermal Energy Distribution System (TEDS) facility and solid-oxide electrolysis cell in the High Temperature Hydrogen Electrolysis (HTHE) facility. Both thermocline and electrolysis cell systems were successfully scaled, and test cases were conducted to generate a doubly accelerated energy charge and discharge in reference to past experimental data from the facilities. The research results represented a case for the thermocline system that required signals to be accelerated without altering the stored energy. To enhance the quality of the accelerated data, error propagation analyses were conducted on DSS post-processing terms to determine the consequences of raw-data-associated errors.

08 HYDROGEN↗

PIP-II LLRF Master Oscillator and Precision Reference Line- Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase synchronization throughout the accelerator. Temperature-induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the master oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods support repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago; Fermilab]↗

A signal compensation based cascaded PI control for an industrial heat exchange system

Since the characteristics of the industrial heat exchange system (HES) are drastically affected by variations of the steam pressure, ambient temperature and water quality, it is difficult for the classical cascade PI control system to meet the desirable control objectives. Therefore, in this paper, a deterministic linear model with unmodeled dynamics is used to describe the dynamic characteristics of the HES. It should be noted that the unmodeled dynamics at the previously sampled instant can be calculated using actual measurements and that the tracking error, which includes effects of the rate of changes of unmodeled dynamics on the controlled model, can be accurately determined. An additional compensating signal is obtained with the feedforward control together with a one-step optimal control law. Consequently, the cascade PI control strategy with the signal compensation is established. Furthermore, the simulation and industrial application show that the proposed method can effectively improve the performance of the cascade PI control system, especially when the unmodeled dynamics is subjected to unknown variations.

42 ENGINEERING↗

Dynamic signal recovery in distribution grids using compressive lossy measurements

Distribution system state estimation requires reliable aggregation of the measured data. However, the large volume of the measured data imposes a significant stress on the underlying communication infrastructure. With the challenges associated with measurement availability, current distribution systems are typically unobservable. To cope with the unobservability issue, compressive sensing theory allows us to recover system state information from a small number of measurements provided the states of the distribution system exhibit sparsity. In this paper, we evaluate the robustness of an updated Kalman filtered modified compressive sensing (KF-ModCS) technique that dynamically estimates the grid states using a small fraction of measured data. In practice, measurements used for sparsity based state estimation may also be intermittent due to communication network induced losses. Further, to understand the effect of packet losses on KF-ModCS, we provide an upper bound for the expected variances of the state estimation error for a given rate of information loss. This upper bound is further improved if the support set of the sparse signal that characterizes the state dynamics does not change over time and/or the reduced model is observable. Simulations based on two practical data sets collected from actual customers in a distribution grid validate the theoretical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applying Linear Optics from Closed Orbits Modulation for finding beam-based alignment of harmonic sextupoles

A fast and accurate beam-based alignment (BBA) method for harmonic sextupoles has been devel oped at NSLS-II using Linear Optics from Closed Orbit Modulation (LOCOM). The approach excites the beam with simultaneous sine-wave signals at two fast correctors, chosen with an appropriate phase advance to span the full betatron phase space. This strategy suppresses systematic errors from hysteresis, while additional errors from orbit drift and power-supply calibration are minimized by the short measurement time (a few minutes) and reliance solely on beam-based current-to-field conver sion of the sextupoles, with hysteresis explicitly included. Simulations indicate that Linear Optics from Closed Orbits (LOCO) combined with 0.5 mm local orbit bumps can resolve relative sextupole field offsets (∆k₂) with precision better than 10% of k₂, reflecting to beam-based alignment (BBA) accuracy finer than 50 µm. Moreover, employing machine-learning-optimized local orbit bumps en hances sextupole-induced quadrupole signals in a deterministic manner and maintains orbit stability under large sextupole strength variations (±40%). The proposed method is experimentally validated through proof-of-principle measurements at NSLS-II, demonstrating its potential as a fast, precise, and robust tool for harmonic sextupole alignment.

43 PARTICLE ACCELERATORS↗

μ⋆ masses: weak-lensing calibration of the Dark Energy Survey Year 1 redMaPPer clusters using stellar masses

ABSTRACT We present the weak-lensing mass calibration of the stellar-mass-based μ⋆ mass proxy for redMaPPer galaxy clusters in the Dark Energy Survey Year 1. For the first time, we are able to perform a calibration of μ⋆ at high redshifts, z > 0.33. In a blinded analysis, we use ∼6000 clusters split into 12 subsets spanning the ranges 0.1 ≤ z < 0.65 and μ⋆ up to ${\sim} 5.5 \times 10^{13} \, \mathrm{M}_{\odot }$, and infer the average masses of these subsets through modelling of their stacked weak-lensing signal. In our model, we account for the following sources of systematic uncertainty: shear measurement and photometric redshift errors, miscentring, cluster-member contamination of the source sample, deviations from the Navarro–Frenk–White halo profile, halo triaxiality, and projection effects. We use the inferred masses to estimate the joint mass–μ⋆–z scaling relation given by $\langle M_{200c} | \mu _{\star },z \rangle = M_0 (\mu _{\star }/5.16\times 10^{12} \, \mathrm{M_{\odot }})^{F_{\mu _{\star }}} ((1+z)/1.35)^{G_z}$. We find $M_0= (1.14 \pm 0.07) \times 10^{14} \, \mathrm{M_{\odot }}$ with $F_{\mu _{\star }}= 0.76 \pm 0.06$ and Gz = −1.14 ± 0.37. We discuss the use of μ⋆ as a complementary mass proxy to the well-studied richness λ for: (i) exploring the regimes of low z, λ < 20 and high λ, z ∼ 1; and (ii) testing systematics such as projection effects for applications in cluster cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of a frequency-dependent phase shift in chirped Raman lasers for atom gravimeters

Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. Here, we directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.

Xu, Yaoyao [Huazhong Univ. of Science and Technolo↗