Search NASA⌕ Search

SEARCH · Search NASA

Results for “EYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Dose conversion coefficients for neutron exposure to the lens of the human eye

Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10{sup -9} to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absorption of wireless radiation in the child versus adult brain and eye from cell phone conversation or virtual reality

Highlights: • More cell phone radiation is absorbed by children's inner brain tissues than adults’. • Children's radiofrequency radiation exposure should be reduced. • Further research to evaluate the risks to the eye from use of VR is urgently needed. • It is biologically relevant and feasible to reduce the standards’ averaging volume. • Current methods to determine wireless device compliance should be revised. Children's brains are more susceptible to hazardous exposures, and are thought to absorb higher doses of radiation from cell phones in some regions of the brain. Globally the numbers and applications of wireless devices are increasing rapidly, but since 1997 safety testing has relied on a large, homogenous, adult male head phantom to simulate exposures; the “Standard Anthropomorphic Mannequin” (SAM) is used to estimate only whether tissue temperature will be increased by more than 1 Celsius degree in the periphery. The present work employs anatomically based modeling currently used to set standards for surgical and medical devices, that incorporates heterogeneous characteristics of age and anatomy. Modeling of a cell phone held to the ear, or of virtual reality devices in front of the eyes, reveals that young eyes and brains absorb substantially higher local radiation doses than adults’. Age-specific simulations indicate the need to apply refined methods for regulatory compliance testing; and for public education regarding manufacturers' advice to keep phones off the body, and prudent use to limit exposures, particularly to protect the young.

54 ENVIRONMENTAL SCIENCES↗

Long-Term Results and Prognostic Factors of Fractionated Strontium-90 Eye Applicator for Pterygium

Purpose: To evaluate the long-term safety, effectiveness, and prognostic factors of fractionated postoperative {beta}-irradiation. Methods and Materials: Between 1993 and 2005, 623 patients with 737 pterygium lesions were treated with a strontium-90 eye applicator after surgical excision. The median follow-up period was 60 months (range, 6.7-139.5). Of the 737 lesions, 644 were primary and 93 were recurrences after surgical removal alone. Fractionated radiotherapy (RT) to a total dose of 35 Gy in five to seven fractions was used. Results: A total of 73 local pterygium recurrences (9.9%) were noted. Of the recurrent cases, 80% were noted within 3 years after treatment. The 5- and 10-year probability of local control was 90% and 88%, respectively. The multivariate analysis for all cases demonstrated that gender, age, total radiation dose, recurrent pterygia, and interval between surgery and RT affected the overall local control rate. Late toxicities that might have been associated with strontium-90 RT included scleromalacia (scleral thinning) in nine eyes, adhesion of the eyelids in eight, cataracts in six, and scleral ulcer in five eyes. Conclusion: Fractionated strontium-90 RT to a total dose of approximately 35 Gy in five to seven fractions results in a similar local control rate as higher doses in other series, with an acceptable complication rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cortexin diffusion in human eye sclera

Investigation of the diffusion of cytamines, a typical representative of which is cortexin, is important for evaluating the drug dose, necessary to provide sufficient concentration of the preparation in the inner tissues of the eye. In the present paper, the cortexin diffusion rate in the eye sclera is measured using the methods of optical coherence tomography (OCT) and reflectance spectroscopy. The technique for determining the diffusion coefficient is based on the registration of temporal dependence of the eye sclera scattering parameters caused by partial replacement of interstitial fluid with the aqueous cortexin solution, which reduces the level of the OCT signal and decreases the reflectance of the sclera. The values of the cortexin diffusion coefficient obtained using two independent optical methods are in good agreement. (optical technologies in biophysics and medicine)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of laser UV radiation on the eye scleral tissue in patients with open-angle glaucoma

We report the results of an experimental study of the effect of short-pulse laser UV radiation on the eye scleral tissue. As samples, we used isolated flaps of the eye scleral tissue from the patients with open-angle glaucoma of the second and third stages. The impact was implemented using the radiation of an excimer XeCl laser with a wavelength of 308 nm and a laser with a wavelength tunable within from 210 to 355 nm. Depending on the problem to be solved, the energy density on the surface of the irradiated tissue varied from a fraction of mJ cm{sup –2} to 15 J cm{sup –2}. For the first time we studied the optical properties of the intraocular fluid in the UV and blue spectral range. The study of the ablation process under the action of radiation with a wavelength of 308 nm showed that the rate of material evaporation can vary within 24 % – 30 % at an energy density above 7 J cm{sup –2}, depending on the glaucoma stage and the individual features of a patient. The excitation – emission matrices of laser-induced fluorescence (LIF) of the eye scleral tissue were studied experimentally using a laser with a wavelength tuned in the range 210 – 355 nm. We found the differences in the LIF spectra caused by the excitation wavelength and the open-angle glaucoma stage. (laser medicine)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-635: Process Mapping of Eye Plaque Brachytherapy

Purpose: To apply a risk-based assessment and analysis technique (AAPM TG 100) to eye plaque brachytherapy treatment of ocular melanoma. Methods: The role and responsibility of personnel involved in the eye plaque brachytherapy is defined for retinal specialist, radiation oncologist, nurse and medical physicist. The entire procedure was examined carefully. First, major processes were identified and then details for each major process were followed. Results: Seventy-one total potential modes were identified. Eight major processes (corresponding detailed number of modes) are patient consultation (2 modes), pretreatment tumor localization (11), treatment planning (13), seed ordering and calibration (10), eye plaque assembly (10), implantation (11), removal (11), and deconstruction (3), respectively. Half of the total modes (36 modes) are related to physicist while physicist is not involved in processes such as during the actual procedure of suturing and removing the plaque. Conclusion: Not only can failure modes arise from physicist-related procedures such as treatment planning and source activity calibration, but it can also exist in more clinical procedures by other medical staff. The improvement of the accurate communication for non-physicist-related clinical procedures could potentially be an approach to prevent human errors. More rigorous physics double check would reduce the error for physicist-related procedures. Eventually, based on this detailed process map, failure mode and effect analysis (FMEA) will identify top tiers of modes by ranking all possible modes with risk priority number (RPN). For those high risk modes, fault tree analysis (FTA) will provide possible preventive action plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Trans -Acting Protein Effect Causes Severe Eye Malformation in the Mp Mouse

Mp is an irradiation-induced mouse mutation associated with microphthalmia, micropinna and hind limb syndactyly. We show that Mp is caused by a 660 kb balanced inversion on chromosome 18 producing reciprocal 3-prime gene fusion events involving Fbn2 and Isoc1. The Isoc1-Fbn2 fusion gene (Isoc1 Mp ) mRNA has a frameshift and early stop codon resulting in nonsense mediated decay. Homozygous deletions of Isoc1 do not support a significant developmental role for this gene. The Fbn2-Isoc1 fusion gene (Fbn2 Mp ) predicted protein consists of the N-terminal Fibrillin-2 (amino acids 1–2646, exons 1– 62) lacking the C-terminal furin-cleavage site with a short out-of-frame extension encoded by the final exon of Isoc1. The Mp limb phenotype is consistent with that reported in Fbn2 null embryos. However, severe eye malformations, a defining feature of Mp, are not seen in Fbn2 null animals. Fibrillin-2 Mp forms large fibrillar structures within the rough endoplasmic reticulum (rER) associated with an unfolded protein response and quantitative mass spectrometry shows a generalised defect in protein secretion in conditioned media from mutant cells. In the embryonic eye Fbn2 is expressed within the peripheral ciliary margin (CM). Mp embryos show reduced canonical Wnt-signalling in the CM – known to be essential for ciliary body development - and show subsequent aplasia of CM-derived structures. We propose that the Mp ‘‘worse-than-null’’ eye phenotype plausibly results from a failure in normal trafficking of proteins that are co-expressed with Fbn2 within the CM. The prediction of similar trans-acting protein effects will be an important challenge in the medical interpretation of human mutations from whole exome sequencing.

59 BASIC BIOLOGICAL SCIENCES↗

Image processing for improved eye-tracking accuracy

Video cameras provide a simple, noninvasive method for monitoring a subject's eye movements. An important concept is that of the resolution of the system, which is the smallest eye movement that can be reliably detected. While hardware systems are available that estimate direction of gaze in real-time from a video image of the pupil, such systems must limit image processing to attain real-time performance and are limited to a resolution of about 10 arc minutes. Two ways to improve resolution are discussed. The first is to improve the image processing algorithms that are used to derive an estimate. Off-line analysis of the data can improve resolution by at least one order of magnitude for images of the pupil. A second avenue by which to improve resolution is to increase the optical gain of the imaging setup (i.e., the amount of image motion produced by a given eye rotation). Ophthalmoscopic imaging of retinal blood vessels provides increased optical gain and improved immunity to small head movements but requires a highly sensitive camera. The large number of images involved in a typical experiment imposes great demands on the storage, handling, and processing of data. A major bottleneck had been the real-time digitization and storage of large amounts of video imagery, but recent developments in video compression hardware have made this problem tractable at a reasonable cost. Images of both the retina and the pupil can be analyzed successfully using a basic toolbox of image-processing routines (filtering, correlation, thresholding, etc.), which are, for the most part, well suited to implementation on vectorizing supercomputers.

NASA Discipline Space Human Factors↗

Use of a genetic algorithm for the analysis of eye movements from the linear vestibulo-ocular reflex

It is common in vestibular and oculomotor testing to use a single-frequency (sine) or combination of frequencies [sum-of-sines (SOS)] stimulus for head or target motion. The resulting eye movements typically contain a smooth tracking component, which follows the stimulus, in which are interspersed rapid eye movements (saccades or fast phases). The parameters of the smooth tracking--the amplitude and phase of each component frequency--are of interest; many methods have been devised that attempt to identify and remove the fast eye movements from the smooth. We describe a new approach to this problem, tailored to both single-frequency and sum-of-sines stimulation of the human linear vestibulo-ocular reflex. An approximate derivative is used to identify fast movements, which are then omitted from further analysis. The remaining points form a series of smooth tracking segments. A genetic algorithm is used to fit these segments together to form a smooth (but disconnected) wave form, by iteratively removing biases due to the missing fast phases. A genetic algorithm is an iterative optimization procedure; it provides a basis for extending this approach to more complex stimulus-response situations. In the SOS case, the genetic algorithm estimates the amplitude and phase values of the component frequencies as well as removing biases.

Non-NASA Center↗

Tracking with the mind's eye

The two components of voluntary tracking eye-movements in primates, pursuit and saccades, are generally viewed as relatively independent oculomotor subsystems that move the eyes in different ways using independent visual information. Although saccades have long been known to be guided by visual processes related to perception and cognition, only recently have psychophysical and physiological studies provided compelling evidence that pursuit is also guided by such higher-order visual processes, rather than by the raw retinal stimulus. Pursuit and saccades also do not appear to be entirely independent anatomical systems, but involve overlapping neural mechanisms that might be important for coordinating these two types of eye movement during the tracking of a selected visual object. Given that the recovery of objects from real-world images is inherently ambiguous, guiding both pursuit and saccades with perception could represent an explicit strategy for ensuring that these two motor actions are driven by a single visual interpretation.

NASA Discipline Neuroscience↗

Spatial coding of eye movements relative to perceived earth and head orientations during static roll tilt

This purpose of this study was to examine the spatial coding of eye movements during static roll tilt (up to +/-45 degrees) relative to perceived earth and head orientations. Binocular videographic recordings obtained in darkness from eight subjects allowed us to quantify the mean deviations in gaze trajectories along both horizontal and vertical coordinates relative to the true earth and head orientations. We found that both variability and curvature of gaze trajectories increased with roll tilt. The trajectories of eye movements made along the perceived earth-horizontal (PEH) were more accurate than movements along the perceived head-horizontal (PHH). The trajectories of both PEH and PHH saccades tended to deviate in the same direction as the head tilt. The deviations in gaze trajectories along the perceived earth-vertical (PEV) and perceived head-vertical (PHV) were both similar to the PHH orientation, except that saccades along the PEV deviated in the opposite direction relative to the head tilt. The magnitude of deviations along the PEV, PHH, and PHV corresponded to perceptual overestimations of roll tilt obtained from verbal reports. Both PEV gaze trajectories and perceptual estimates of tilt orientation were different following clockwise rather than counterclockwise tilt rotation; however, the PEH gaze trajectories were less affected by the direction of tilt rotation. Our results suggest that errors in gaze trajectories along PEV and perceived head orientations increase during roll tilt in a similar way to perceptual errors of tilt orientation. Although PEH and PEV gaze trajectories became nonorthogonal during roll tilt, we conclude that the spatial coding of eye movements during roll tilt is overall more accurate for the perceived earth reference frame than for the perceived head reference frame.

NASA Discipline Neuroscience↗

Eye movements and motion perception induced by off-vertical axis rotation (OVAR) at small angles of tilt after spaceflight

The nystagmus and motion perception of two astronauts were recorded during Earth-vertical axis rotation and during off-vertical axis rotation (OVAR) before and after 7 days of spaceflight. Postflight, the peak velocity and duration of per- and postrotatory nystagmus during velocity steps about the Earth-vertical axis were the same as preflight values. During OVAR at constant velocity (45/s, tilt angles successively 5, 10, and 15 degrees), the mean horizontal slow-phase eye velocity (bias), produced by the 'velocity storage mechanism' in the vestibular system, and the peak-to-peak amplitude (modulation) in horizontal eye velocity and position, generated from the output of otolith afferents, were also the same before as after flight. There were, however, changes in the vertical eve position and in the perceived body motion during OVAR. The angle of the perceived body path described as a cone was larger in both astronauts postflight. One astronaut experienced either a large cone angle with its axis upright, or a smaller cone angle with its axis tilted backwards, accompanied by an upward vertical eye drift. These results suggest an increase in the sensitivity of the otolithic system after spaceflight and a longer period of readaptation to Earth's gravity for otolith-induced responses than for canal-induced responses. Our data support the hypothesis that just after spaceflight the CNS generally interprets changes in the otolith signals to be due to translation rather than to tilt.

manned↗

Three dimensional eye movements of squirrel monkeys following postrotatory tilt

Three-dimensional squirrel monkey eye movements were recorded during and immediately following rotation around an earth-vertical yaw axis (160 degrees/s steady state, 100 degrees/s2 acceleration and deceleration). To study interactions between the horizontal angular vestibulo-ocular reflex (VOR) and head orientation, postrotatory VOR alignment was changed relative to gravity by tilting the head out of the horizontal plane (pitch or roll tilt between 15 degrees and 90 degrees) immediately after cessation of motion. Results showed that in addition to post rotatory horizontal nystagmus, vertical nystagmus followed tilts to the left or right (roll), and torsional nystagmus followed forward or backward (pitch) tilts. When the time course and spatial orientation of eye velocity were considered in three dimensions, the axis of eye rotation always shifted toward alignment with gravity, and the postrotatory horizontal VOR decay was accelerated by the tilts. These phenomena may reflect a neural process that resolves the sensory conflict induced by this postrotatory tilt paradigm.

NASA Program Space Physiology and Countermeasures↗

An information maximization model of eye movements

We propose a sequential information maximization model as a general strategy for programming eye movements. The model reconstructs high-resolution visual information from a sequence of fixations, taking into account the fall-off in resolution from the fovea to the periphery. From this framework we get a simple rule for predicting fixation sequences: after each fixation, fixate next at the location that minimizes uncertainty (maximizes information) about the stimulus. By comparing our model performance to human eye movement data and to predictions from a saliency and random model, we demonstrate that our model is best at predicting fixation locations. Modeling additional biological constraints will improve the prediction of fixation sequences. Our results suggest that information maximization is a useful principle for programming eye movements.

NASA Discipline Neuroscience↗

Selenium Preferentially Accumulates in the Eye Lens Following Embryonic Exposure: A Confocal X-ray Fluorescence Imaging Study

Maternal transfer of elevated selenium (Se) to offspring is an important route of Se exposure for fish in the natural environment. However, there is a lack of information on the tissue specific spatial distribution and speciation of Se in the early developmental stages of fish, which provide important information about Se toxicokinetics. The effect of maternal transfer of Se was studied by feeding adult zebrafish a Se-elevated or a control diet followed by collection of larvae from both groups. Novel confocal synchrotron-based techniques were used to investigate Se within intact preserved larvae. Confocal X-ray fluorescence imaging was used to compare Se distributions within specific planes of an intact larva from each of the two groups. The elevated Se treatment showed substantially higher Se levels than the control; Se preferentially accumulated to highest levels in the eye lens, with lower levels in the retina, yolk and other tissues. Confocal X-ray absorption spectroscopy was used to determine that the speciation of Se within the eye lens of the intact larva was a selenomethionine-like species. Preferential accumulation of Se in the eye lens may suggest a direct cause-and-effect relationship between exposure to elevated Se and Se-induced ocular impairments reported previously. This study illustrates the effectiveness of confocal X-ray fluorescence methods for investigating trace element distribution and speciation in intact biological specimens

Choudhury, Sanjukta↗

Measuring the elastic wave velocity in the lens of the eye as a function of intraocular pressure using optical coherent elastography

The dependence of the elastic properties of the eye lens on the intraocular pressure is investigated in porcine eyes ex vivo. To measure the stiffness of the lens, the method of dynamic optical coherent elastography is used, in which the propagation velocity of surface elastic waves in the lens is measured using phase-sensitive optical coherent tomography. Measurement data show an increase in Young’s modulus of the lens by ∼30% with an increase in intraocular pressure from 10 to 40 mm Hg. This result allows us to conclude that the effect of intraocular pressure on the rigidity of the lens is less significant than on the rigidity of other eye tissues, such as the cornea and sclera. The method of optical coherent elastography makes it possible to measure the elastic properties of the lens without removing it from the eyeball and has considerable potential for clinical use. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo dosimetry for {sup 125}I and {sup 103}Pd eye plaque brachytherapy with various seed models

Purpose: Dose distributions are calculated for various models of {sup 125}I and {sup 103}Pd seeds in the standardized plaques of the Collaborative Ocular Melanoma Study (COMS). The sensitivity to seed model of dose distributions and dose distributions relative to TG-43 are investigated. Methods: Monte Carlo simulations are carried out with the EGSnrc user-code BrachyDose. Brachytherapy seeds and eye plaques are fully modeled. Simulations of one seed in the central slot of a 20 mm Modulay (gold alloy) plaque backing with and without the Silastic (silicone polymer) insert and of a 16 mm fully loaded Modulay/Silastic plaque are performed. Dose distributions are compared to those calculated under TG-43 assumptions, i.e., ignoring the effects of the plaque backing and insert and interseed attenuation. Three-dimensional dose distributions for different {sup 125}I and {sup 103}Pd seed models are compared via depth-dose curves, isodose contours, and tabulation of doses at points of interest in the eye. Results are compared to those of our recent BrachyDose study for COMS plaques containing model 6711 ({sup 125}I) or 200 ({sup 103}Pd) seeds [R. M. Thomson et al., Med. Phys. 35, 5530-5543 (2008)]. Results: Along the central axis of a plaque containing one seed, variations of less than 1% are seen in the effect of the Modulay backing alone for different seed models; for the Modulay/Silastic combination, variations are 2%. For a 16 mm plaque fully loaded with {sup 125}I ({sup 103}Pd) seeds, dose decreases relative to TG-43 doses are 11%-12% (19%-20%) and 14%-15% (20%) at distances of 0.5 and 1 cm from the inner sclera along the plaque's central axis, respectively. For the same prescription dose, doses at points of interest vary by up to 8% with seed model. Doses to critical normal structures are lower for all {sup 103}Pd seed models than for {sup 125}I with the possible exception of the sclera adjacent to the plaque; scleral doses vary with seed model and are not always higher for {sup 103}Pd than for {sup 125}I. Conclusions: Dose decreases relative to doses calculated under TG-43 assumptions vary slightly with seed model (for each radionuclide). Dose distributions are sensitive to seed model; however, variations are generally no larger than the magnitudes of other systematic uncertainties in eye plaque therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Eye tracking and gating system for proton therapy of orbital tumors

Purpose: A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. Methods: We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, Austin, TX). To measure the pixel spacing of an image consistently, four different calibration modes such as the point-detection, the edge-detection, the line-measurement, and the manual measurement mode were suggested and used. After these methods were applied to proton therapy, gating was performed, and radiation dose distributions were evaluated. Results: Moving phantom verification measurements resulted in errors of less than 0.1 mm for given ranges of translation. Dosimetric evaluation of the beam-gating system versus nongated treatment delivery with a moving phantom shows that while there was only 0.83 mm growth in lateral penumbra for gated radiotherapy, there was 4.95 mm growth in lateral penumbra in case of nongated exposure. The analysis from clinical results suggests that the average of eye movements depends distinctively on each patient by showing 0.44 mm, 0.45 mm, and 0.86 mm for three patients, respectively. Conclusions: The developed automatic eye-tracking based beam-gating system enabled us to perform high-precision proton radiotherapy of orbital tumors.

60 APPLIED LIFE SCIENCES↗