Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Benefits Of Automated Construction And Energy Efficiency Measures In Modular Homes

This article builds on and adds to a Buildings XV publication that introduced the Transformative Efficiency and Automation in Modular Homes (TEAMH) project. The TEAMH project sought to develop a scalable solution for producing modular homes with 20-50% energy savings and similar cost relative to site-fabricated single-family home construction. A key aspect of the project was assessing the potential for labor cost reductions through automation-assisted construction using light gauge steel (LGS). To quantify the advantages of this approach, side-by-side comparisons were made between traditional wood-framed construction and automation-assisted LGS construction. This demonstration involved constructing one wood-framed wall and several LGS test walls, accompanied by a time-and-motion study. The results indicated that automation assistance could decrease construction time and associated labor costs by as much as 46%. High-performance envelope technologies for exterior insulation and air sealing were evaluated to compare modular homes with site-built homes that meet the International Energy Conservation Code (IECC). A key technology considered was vacuum insulation panels (VIPs) with fiberglass cores. Guarded hot box testing of multiple full-scale wall assemblies containing different combinations of exterior continuous insulation systems containing phenolic foam and VIPs. Testing on various full-scale wall assemblies revealed that, with LGS construction, cavity insulation had minimal impact on exterior wall performance. Omitting cavity insulation can reduce labor and material costs while streamlining manufacturing, as its installation is labor-intensive and not easily automated due to the need for precise placement around wiring and other internal components. Guarded hot box tests of multiple LGS test walls with foam and VIP-based exterior insulation systems achieved R-values of up to 31 hr-ft2-°F/Btu. Finally, building energy modeling of multiple modular home designs indicated that the upgraded envelope assemblies can yield heating energy savings of up to 50% and cooling energy savings of up to 30% compared to IECC 2018 standards.

Shrestha, Som [ORNL] (ORCID:0000000183993797)↗

MASK4 Test Campaign for Sandia WaveBot Device

This data and report details the findings from a wave tank test focused on production of useful work of a wave energy converter (WEC) device. The experimental system and test were specifically designed to validate models for power transmission throughout the WEC system. Additionally, the validity of co-design informed changes to the power take-off (PTO) were assessed and shown to provide the expected improvements in system performance. These data describe the "MASK4" wave tank test of the Sandia WaveBot device. The WaveBot device has been tested a number of times in different permutations at the US Navy's Maneuvering and Sea Keeping (MASK) basin. Each test in this series is referred to as MASK1, MASK2, etc. The WaveBot device was first tested in one degree of freedom (heave) in 2016. This MASK1 test focused primarily on system identification and modeling. After MASK1, major modifications were performed to improve the overall real-time control and measurement system, improve the heave drive train, and add surge and pitch degrees of freedom. The second set of testing, which was broken up in to two stages: MASK2A and MASK2B, focused on bench testing and closed-loop control performance as well as nonlinear modeling. MASK3 then focused on multi-input, multi-output modeling and control for maximization of electrical power. The attached report presents the results from MASK4, which focuses on detailed modeling of the power conversion chain and validation co-design principles by way of the introduction of a magnetic spring. The test log, report, and data from the MASK4 test of the WaveBot augmented with a tunable magnetic spring. Processing codes can be found at the Github link below.

16 TIDAL AND WAVE POWER↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TEAMER: Biofouling Analysis for Wave Energy Piston Design - Load Cell Data

Biofouling and corrosion are a major concern for all ocean-deployed components, especially when mechanical motion is involved. Triton has developed the concept of a biofouling mitigation seal as part of the piston sealing assembly for the Triton Wave Energy Converter (TSI-WEC). This mitigation seal has the purpose of preventing the formation of a biofilm on the inside of the piston cylinder. It is hypothesized that the prevention of a biofilm will reduce the amount of macro-biofouling that can occur in the piston assembly. The mitigation seal can also reduce the wear on the main dynamic seal, helping to maintain smooth operation and water-tightness. The cylinder is made from a thermoset composite epoxy, which is resistant to corrosion. However, no studies have researched the material's performance with biofouling. Triton placed two prototype Power Take-Off (PTO) assemblies in a PNNL biofouling tank, one with a biofouling mitigation seal and one without, allowing for an evaluation of seal effectiveness at the prevention of biofouling. In actual WEC operation, wave action would react against the piston, which would drive the linear actuator and electric generator, providing electrical power. In the test setup, this was reversed; a linear actuator was powered to drive the piston in a consistent motion within the cylinder. There are two assemblies: one has a biofouling mitigation seal, the other (control) does not. The following data encompasses a 4 month test period, with load cells being used to monitor piston friction force. Results from this testing will be used to improve seal design and material selection, mitigating risk of premature failure during open water testing and evaluation. This project is part of the TEAMER RFTS 3 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

Data for Post-Access Report: Tidal Energy Resource Characterization and Model Validation via the Assessment of Cost-effective Spatially Distributed Current Measurements from microFloat Swarms

This project evaluated how high-resolution, spatially distributed field data can be used to refine and validate site-scale hydrodynamic simulations of tidal channels. Use of such spatially-distributed field observations or site-scale hydrodynamic simulations will be needed for producing accurate predictions of tidal energy production over larger arrays of tidal turbines. The data contained in this archive includes field observations of water velocity from a series of short surveys in Agate Pass taken on August 20th, 2020 using station-keeping ADCP (acoustic doppler current profiler) measurements, drifting downward-looking ADCPs, and microFloats, gathered by researchers at APL-UW under a previous project. It also includes high-resolution hydrodynamic model runs for the site during that time generated under TEAMER support. An explanatory file (.pdf format) describes the survey and field data structure. Processed data is stored in .mat format. Survey summary: start time, number of floats, water level. microFloat data: - Cleaned data for each float in survey, - Time series of position (lat., lon.), depth (relative to surface), and horizontal velocity (u, v) Drifting ADCP data: - Cleaned data for each drifting ADCP in survey - Time series of position (lat., lon.), sample depth (relative to surface), and observed water velocity (u,v,w) Stationary ADCP data: - Cleaned data for each station-keeping data set in survey - Time series of position (lat., lon.), sample depth (relative to surface), and observed water velocity (u,v,w) FVCOM (Finite Volume Coastal Ocean Model) model outputs: Water level and velocity, as well as derived variables (e.g., power density) from the final refined model simulations for the Agate Pass subdomain. Contained in NetCDF and ASCII files for the duration of August 18th and 20th 2020 field surveys. Additional scripts for processing the data and generating the figures in the report are included.

16 TIDAL AND WAVE POWER↗

Initial validation of ALFRED: A Monte Carlo code built on Geant4 for TREAT energy deposition

Predicting the energy deposited in the specimen during an experiment in the Transient Reactor Test (TREAT) Facility is a complex problem due to the nature of the transients occurring in the reactor. In addition, the many particles contributing to energy deposition have different behavior in time and space. ALFRED, a new Geant4 based code, is developed to transport and simulate each particle generated in the core. This code is verified against OpenMC (Open Monte Carlo) on the Godiva benchmark and a simple TREAT model. Next, the energy deposition in TREAT is calculated: 181.05 ± 0.01 MeV for the “instantaneous” energy deposition (which accounts for the energy deposited within 1 s after neutron emission) in fuel and 189.90 ± 0.01 MeV for the total energy deposition in fuel. We discuss these results in this paper with previous calculations and experimental evaluations. This work demonstrates ALFRED’s potential as a high-fidelity tool for computing the spatial and temporal energy deposition in TREAT paving the way for a better understanding of the energy coupling factors in TREAT.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hawaii Wave Surge Energy Converter (HAWSEC) OSU O.H. Hinsdale Basin

The following information and metadata applies to both the Phase I (Hydrodynamics) and Phase II (Full System Power Take-Off) zip folders which contain testing data from the OSU (Oregon State University) O.H. Hinsdale Wave Research Laboratory, from both OSU and the University of Hawaii at Manoa (UH). See zip folders provided further below in the downloads section. For experimental data of the full system, including PTO, see Phase II dataset. There are two main directories in each Phases's zip folder: "OSU_data" and "UH_data". The "OSU_data" directory contains data collected from their DAQ (data acquisition system), which includes all wave gauge observations, as well as body motions derived from their Qualisys motion tracking system. The organization of the directory follows OSU's convention. Detailed information on the instrument setup can be found under "OSU_data/docs/setup/instm_locations". The experiments conducted are documented in the "OSU_data/docs/daq_logs", which provides the trial number to the corresponding data located under "OSU_data/data" in several formats (e.g., ".mat" and ".txt"). Inside the trial directory, data is provided for each of the instruments defined in "OSU_data/docs/setup/instm_locations". The "UH_data" directory contains data collected from their DAQ. The data is stored in a ".tdms" file format. There are free plug-ins for Microsoft Excel and MathWorks MATLAB to read the ".tdms" format. Below are a few links providing methods to read in the data, but a Google search should identify alternatives sources if these no longer exist (valid as of January 2024): Excel: http://www.ni.com/example/27944/en/ MATLAB: https://www.mathworks.com/matlabcentral/fileexchange/30023-tdms-reader The Excel plugin is recommend to get a quick overview of the data. The UH data is organized by directory name, in which the sub-directories for each experiment contains a directory whose name defines the wave height and period for the experimental data within. For example, a directory name "H02_T0275" corresponds to an experiment with wave height 0.1m and a period of 2.75s. For random wave data, the gamma value is also included in the directory name. For example, a directory name "H02_T0225_G18" corresponds to an experiment with a significant wave height of 0.2m, a peak period of 2.25s, and a gamma value of 1.8, with each spectra being a TMA spectrum. For the free decay experiments, the directory name is defined by the initial angular displacement. For example, a directory name "ang05_run01" corresponds to an experiment with an initial angular displacement of 5 degrees. There is a dataset in the UH data for each corresponding experiment defined in the OSU DAQ logs. The ".tdms" data is output from the DAQ at fixed intervals. Therefore, if multiple files are contained within the folder, the data will need to be stitched together. Within the UH dataset, there are two input channels from the OSU DAQ providing a random square wave signal for time synchronization ("ENV-WHT-0010") and a high/low signal ("ENV-WHT-0012") to identify when the wave maker is active (+5V). The UH data is logged as a collection of channel outputs. Channels not in use for the OSU testing (either Phase I or Phase II) are marked "nan" below. If the sensor is disconnected, it will record noise throughout the experiment. Below are the channel definitions in terms of what they measure: GPS Time = time CYL-POS-0001 = position between flap and fixed reference CYL-LCA-0001 = force between flap and hydraulic cylinder REC-LPT-0001 = nan REC-HPT-0001 = nan REC-HPT-0002 = nan REC-HPT-0003 = nan HHT-HPT-0001 = pressure at exhaust ("head" only) REC-FQC-0001 = nan REC-FQC-0002 = nan HHT-FQC-0001 = flow at exhaust ("head" only) ENV-WHT-0001 = nan ENV-WHT-0002 = nan ENV-WHT-0003 = nan ENV-WHT-0010 = random signal from OSU DAQ ENV-WHT-0012 = high/low signal from OSU DAQ Also included is a calibration curve to convert the string pot data to flap pi...

16 TIDAL AND WAVE POWER↗

Fast solvers for tokamak fluid models with PETSc

Multigrid (MG) is widely recognized as a highly effective solver for the model problem, the Laplacian, but textbook MG fails on most problems of interest. MG methods have been applied to complex, real-world applications with careful consideration of the physical model and discretization. In this work we develop the first step in applying MG methods to science and engineering relevant magnetohydrodynamics (MHD) tokamak models in the M3D-C1 (https://m3dc1.pppl.gov) fusion energy science code. The semi-implicit time integrator in M3D-C1 is composed of many linear solves. The implicit advance of the momentum equation is the most challenging and is the focus of this work. The current production solver in M3D-C1 is a block Jacobi (BJ) preconditioner within a Krylov solver, where blocks group degrees of freedom on planes of constant toroidal coordinate. BJ convergence degrades as the number of planes increases due to the spectral properties of the matrix preconditioned with BJ. The partially magnetic field-aligned, regular toroidal grid structure in M3D-C1 is amenable to semi-coarsening geometric MG in the toroidal direction. This paper develops such a solver and demonstrates competitive performance on a runaway electron model of a SPARC (https://cfs.energy/technology/sparc) disruption, and superior robustness on a stellarator model on which the BJ solver fails to converge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CalWave - TEAMER UMaine 2021 Tank Testing

This is the data submission to the teamer report for RFTS1 during which tank testing at UMaine W2 tank occurred. This submission includes the relevant information and recorded data of CalWave's UMaine wave tank testing conducted under TEAMER Request for Support Round 1. During the testing CalWave assessed an autonomous control approach for changing PTO gain parameters based on "on board" sea state detection. The data submitted includes an overview of normalized PTO gains based on sea state values and for a set of 8 relevant sea states the WEC motion. All data was collected on CalWave's SCADA system and UMaine's motion tracking system. The data submitted suffices the creation of figures as shown in the PDF report submitted alongside the data and the submission includes excel sheets (parameter gains), MATLAB structures (absorber motion), and the mentioned PDF report.

16 TIDAL AND WAVE POWER↗

Unique Building Identifier (UBID): Public Sector Implementation Guide

Buildings generate data throughout their lifecycle – about ownership & taxation, usage, zoning, code compliance, energy use, and retrofits. State and local governments collect this data after it flows through growing networks of people and systems. But collecting data is only half the battle; what’s really needed is information – the actionable insights that lead to successful policy outcomes.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Codes and Ordinances for Clean Energy: Highland Park Pathways to Power [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "A" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2023 National Offshore Wind data set (NOW-23)

The 2023 National Offshore Wind data set (NOW-23) is the latest wind resource data set for offshore regions in the United States, which supersedes, for its offshore component, the Wind Integration National Dataset (WIND) Toolkit, which was published about a decade ago and is currently one of the primary resources for stakeholders conducting wind resource assessments in the continental United States. The NOW-23 data set was produced using the Weather Research and Forecasting Model (WRF) version 4.2.1. A regional approach was used: for each offshore region, the WRF setup was selected based on validation against available observations. The WRF model was initialized with the European Centre for Medium Range Weather Forecasts 5 Reanalysis (ERA-5) data set, using a 6-hour refresh rate. The model is configured with an initial horizontal grid spacing of 6 km and an internal nested domain that refined the spatial resolution to 2 km. The model is run with 61 vertical levels, with 12 levels in the lower 300m of the atmosphere, stretching from 5 m to 45 m in height. The MYNN planetary boundary layer and surface layer schemes were used the North Atlantic, Mid Atlantic, Great Lakes, Hawaii, and North Pacific regions. On the other hand, using the YSU planetary boundary layer and MM5 surface layer schemes resulted in a better skill in the South Atlantic, Gulf of Mexico, and South Pacific regions. A more detailed description of the WRF model setup can be found in the WRF namelist files linked at the bottom of this page. For all regions, the NOW-23 data set coverage starts on January 1, 2000. For Hawaii and the North Pacific regions, NOW-23 goes until December 31, 2019. For the South Pacific region, the model goes until 31 December, 2022. For all other regions, the model covers until December 31, 2020. Outputs are available at 5 minute resolution, and for all regions we have also included output files at hourly resolution. The NOW-23 data are provided here as HDF5 files. Examples of how to use the HSDS Service to Access the NOW-23 files are linked below. A list of the variables included in the NOW-23 files is also linked below. No filters have been applied to the raw WRF output.

Array↗

A Conversation on Standard 90.1-2019

This article presents a roundtable discussion of the new edition of ASHRAE Standard 90.1-2019 Energy Standard for Buildings Except Low-Rise Residential Buildings. It discusses updates to the standard, challenges overcome, and thoughts about the trajectory of future versions of the standard. Contributors include leading members of the Standard 90.1 development committee.

ASHRAE Standard 90.1, ASHRAE, Energy Code↗

Developing a Composite Vacuum Insulated Panel (VIP) Insulation/Vinyl Siding Composite Technology for Retrofitting Residential Walls

This paper reports on a project that has attempted to seize on an opportunity to take a giant leap forward in commercializing a technology that would address a key opportunity to achieve energy savings in the existing residential housing stock. It is typically very difficult to increase the R-value of the walls in existing residential housing as doing so from the inside is disruptive and there have not been good solutions to increase thermal envelope performance from the exterior through adding continuous insulation due to the additional work required to fit existing architectural features to the new wall thickness and to reclad the façade. A high thermal resistivity or R-value per inch product that can be used in these applications offers an excellent solution.This paper summarizes a three-year research project to a produce vacuum insulated panel (VIP)/vinyl siding that would have sufficient R-value to meet the continuous insulation requirements of the 2018 International Energy Conservation Code (IECC, 2018) in all climate zones and has a much thinner profile that will facilitate its application to existing residential homes without the need for expensive retrimming of the architectural details. The paper will supply information on the development of the technology, its thermal modelling, testing, voice of user sessions to solicit input from architects, designers, manufacturers, contractors, and installers, and a techno-economic analysis to gauge its competitiveness with existing product options.

Desjarlais, Andre Omer↗

Developing a Composite Vacuum Insulated Panel (VIP) Insulation/Vinyl Siding Composite Technology for Retrofitting Residential Walls

This paper reports on a project that has attempted to seize on an opportunity to take a giant leap forward in commercializing a technology that would address a key opportunity to achieve energy savings in the existing residential housing stock. It is typically very difficult to increase the R-value of the walls in existing residential housing as doing so from the inside is disruptive and there have not been good solutions to increase thermal envelope performance from the exterior through adding continuous insulation due to the additional work required to fit existing architectural features to the new wall thickness and to reclad the facade. A high thermal resistivity or R-value per inch product that can be used in these applications offers an excellent solution. This paper summarizes a three-year research project to a produce vacuum insulated panel (VIP)/vinyl siding that would have sufficient R-value to meet the continuous insulation requirements of the 2018 International Energy Conservation Code (IECC, 2018) in all climate zones and has a much thinner profile that will facilitate its application to existing residential homes without the need for expensive retrimming of the architectural details. The paper will supply information on the development of the technology, its thermal modelling, testing, voice of user sessions to solicit input from architects, designers, manufacturers, contractors, and installers, and a techno-economic analysis to gauge its competitiveness with existing product options.

Desjarlais, Andre↗

Modeling Efforts to Gain Insight into Historical Leak Events from the Single-Shell Tank A-105 in the Hanford 241-A Tank Farm - 20113

The 241-A Tank Farm is a single-shell tank (SST) farm constructed to store process waste from Hanford nuclear operations. Millions of gallons of nuclear waste were stored in the 241-A Tank Farm SSTs and some of the SSTs leaked in the past. In addition, spills and pipeline leaks during transfers and storage and intentional discharges to cribs and trenches resulted in releasing waste to the ground. Tank liner leaks are referred to as 'leaks' and all other discharges to the soil are referred to as 'releases.' Liquid waste that could be removed by pumping has been removed from all of the SSTs to reduce the potential for future leaks. The most significant historical leak event in 241-A Tank Farm occurred in 1965 when tank A-105 experienced a pressurized steam event. This event resulted in damage to the inner steel liner flooring of A-105, which was separated from the sidewalls over part of its circumference and buckled up to 2.5 m, vertically. During this event up to 7,570 L of contaminated liquid may have leaked to the adjacent soil. This leak occurred under extreme temperature and pressure conditions. Modeling efforts to better understand the nature and extent of historical leaks from subsurface SSTs that were used to store highly radioactive, self-boiling liquid wastes at 241-A Tank Farm have recently been undertaken. These efforts have compiled the available historical information to support a preliminary non-isothermal, multiphase flow and chemical transport modeling effort to re-create the conditions under which the leaks occurred and to formulate a conceptual model as to the extent and distribution of leaked radioactive contaminants in the adjacent soil material. The focus of this work was on developing an understanding of the key features, processes and bounding conditions related to tank A-105 leak events that occurred in the 1960's. The activities include estimation of leak composition, non-isothermal multiphase flow and transport modeling, and geochemical modeling. The STOMP{sup C} Water-Air-Energy modeling code was utilized to implement the three-dimensional representation of the subsurface tank and the surrounding flow field. Once constructed, the model was used to evaluate the conceptual understanding of leaks originating from different parts of the tank under the elevated temperature boundary conditions that were imposed by surrounding tanks at the time of the historical leaks. The chemical evolution of the liquid waste was also evaluated as it leaked from the tank under transient pressure and temperature gradients. The results of the preliminary evaluation suggested the presence of a heat-pipe effect beneath tank A-105 in which water vapor at an elevated temperature is driven away from the base of the tank to a position where water vapor cools, condenses and is then drawn back toward the tank by the strong capillary attraction of the dry soil. A non-sorbing contaminant (Tc-99) was introduced into this flow field to better understand the potential distribution patterns of leaked contaminants that may have occurred during the historical leak events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗