Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy consumption forecasting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

1999 Puget Sound Household Travel Survey

The 1999 Puget Sound Household Travel Survey was conducted between July and November. NuStats Research and Consulting conducted the survey on behalf of the Puget Sound Regional Council. The purpose of the study was to provide data to continue developing and refining the Regional Travel Demand Forecasting Model, as well as to provide a better understanding of travel behavior in the Puget Sound region. The study area consists of King, Kitsap, Pierce, and Snohomish counties. The resultant dataset will be used to fulfill the model's functions of estimating trip generation and distribution, mode choice, and assignments. The study had household members 16 years old or older keep track of travel for a 48-hour period. A total of 9,028 households were recruited to participate in the study. Of these, 6,000 households (66.5%) completed travel diaries, and the information was retrieved from all household members regardless of age. An “attitude” survey about transportation and land use issues was also mailed to household members 16 years old or older.

1Hz data↗

2007 Chicago Regional Household Travel Inventory

To provide data for developing and refining travel demand forecast models, the 2007 Regional Household Travel Inventory studied the demographic and travel behavior characteristics of residents in the greater Chicago area. It included households in eight counties in Illinois and three in Indiana. The Chicago Metropolitan Agency for Planning conducted the study in coordination with the Illinois Department of Transportation, the Northwestern Indiana Regional Planning Commission, and the Indiana Department of Transportation. Travel and activity information for all household members (regardless of age) was collected during a randomly assigned 24- or 48-hour period. It relied on the willingness of households to provide detailed information about their members and vehicles, and to record all travel and associated activity during the collection period. This study also featured a subsample of households collecting data via in-vehicle and wearable global positioning system devices.

1Hz data↗

2001 Atlanta Household Travel Survey

The 2001 Atlanta Household Travel Survey collected demographic, socioeconomic, and travel information on work and non-work travel behavior for a 48-hour travel period. The study was conducted on behalf of the Atlanta Regional Commission, and it is an essential element in the transportation planning and modeling efforts for the 13-county Atlanta region. The main objective of the study was to produce data that could be used to develop and calibrate travel demand models for use in travel forecasting, land use planning, and air quality planning to improve the transportation system. The second component in the survey was the deployment of an electronic travel diary with person-based GPS and an accelerometer to collect health and activity information. Travel data includes trip generation, trip distribution, and modal choice. The survey recruited a total of 12,184 households to participate in the study. Of these, 8,069 households (66%) completed travel. The 8,069 households, when weighted, represent 21,323 persons, 14,449 vehicles, and 126,127 places visited from April 2001 through April 2002. This dataset is part of the Metropolitan Travel Survey Archive, which includes travel surveys from numerous public agencies across the United States and is archived by the Transportation Secure Data Center to ensure their continued public availability.

1Hz data↗

A novel probabilistic regression model for electrical peak demand estimate of commercial and manufacturing buildings

Due to the high cost of electricity in commercial and industrial sectors, demand forecast models have gained increasing attention. However, there are two unresolved issues: (1) Models are not adaptable when exposed to previously unknown data (2) The value of regression methods vs. state-of-the-art machine learning models has not been made apparent before. This study’s goal is to develop probabilistic demand estimation models. Herein, we propose a probabilistic Bayesian regression framework that can not only estimate future demands with high accuracy but also be updated once new information is available. By applying the proposed algorithm to two real-world case studies (commercial and manufacturing), we show a 40.3% and 30.8% improvement in terms of mean absolute error for the two cases. Moreover, the proposed technique outperforms powerful machine learning approaches, including support vector machine by 10.39%, random forest by 6.17%, and multilayer perceptron by 9.14% in terms of mean absolute percentage error.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Improving Coal-Fired Plant Performance Through Integrated Predictive and Condition-Based Monitoring Tools

The project demonstrated the ability to improve boiler performance and reliability through the integrated use of condition-based monitoring (CBM) and predictions of the impacts of coal quality on boiler operations at a full-scale coal-fired power plant. The advanced tool developed actively monitors and manages coal quality and overall boiler conditions that maximizes availability and maintains generating capacity while reducing cost. The tool is used to forecast and alert plant operators and engineers about poor boiler conditions which may occur as a result of incoming coal and/or current power plant operating conditions. The Combustion System Performance Indices (CSPI) and CoalTracker (CT) programs predicts fireside performance of the plant including slagging, fouling, erosion, slag flow, strength development (sintering/densification), and slag layer thickness based on the composition of delivered coal. CT program is tailored for each plant and is used to track the coal from the point of delivery to the burner. The most successful application of the CSPI-CT has been at plants where the coal composition is determined through the use of a full stream elemental analyzers based on prompt gamma neutron analysis (PGNAA). The CSPI-CT program information is used by coal procurement, coal mining and plant operations personnel to select and blend coal properties for the best plant performance.

01 COAL, LIGNITE, AND PEAT↗

Hierarchical Model-Free Transactive Control of Building Loads to Support Grid Services

Residential buildings consume 4.4 quads of electricity annually, approximately 37% of the total electricity consumption in the United States. This represents a vast resource that can be used for demand management and other ancillary services. This project aims to develop a robust, scalable hierarchical transactional control mechanism incorporating elements of model-free control (MFC) and game theory to harness buildings to provide ancillary services to the grid. This approach is being taken to address the challenges of incorporating traditional transactional control schemes into existing buildings. The challenges include small individual building sizes requiring aggregation of many buildings, unpredictable energy usage that makes model identification difficult, and satisfying the sensitive occupant comfort constraints. In the proposed approach, by separating the control mechanism into two layers above and below the load aggregator, MFC can be used below the aggregator to modulate flexible building loads in response to pricing signals with guaranteed performance. This allows the burden of identifying an accurate model of the system to be shifted to the above-aggregator layer, where fluctuations in individual building usage have less impact on predicted building system behavior. Game theory concepts can then be used to determine pricing curves and control signals among regional aggregators. Managing this control in a game-theoretic approach will allow us to build in financial incentives that increase customer engagement. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable on small, embedded devices. In a broader sense, developing a strategy capable of effectively incorporating residential and small commercial buildings will allow greater throughput of existing and emerging grid services in addition to future transactive energy grid management methods. Using MFC within a hierarchical control architecture will allow the shifting of existing forecasting challenges to an aggregate level, where dynamics are slower and more predictable. This will enable a smooth interface between the grid services requests of utilities and the reliable control required by participating buildings. MFC, which supports distributed control architecture, permits a scalable solution that can be deployed to neighborhood-size systems as well as individual buildings. This project focuses on three objectives: (1) developing the mathematical framework, algorithm toolkit, and software toolset of the two-layer transactive control testbed; (2) developing a scalable solution for application over many residential and small-size commercial buildings with sparse distributed communication; and (3) field testing and implementation on hardware of the control strategies developed in the previous two objectives. The research and development activities are focused and designed to be impactful within the relevant 2025 targets timeframe. An open-source control framework for exploiting variability and dispatchability of building loads will be delivered as the outcome of the project. This capability enables greater participation of loads in electricity markets and ancillary services that are both useful for the utility and financially beneficial for building owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Machine Learning Derived Dynamic Operating Reserve Requirements in High-Renewable Power Systems

Accurately forecasting wind and solar power output poses challenges for deeply decarbonized electricity systems. Grid operators must commit resources to provide reserves to ensure reliable operations in the face of forecast errors, a process which can increase fuel consumption and emissions. We apply neural network-based machine learning to expand the usefulness of median point forecast data by creating probabilistic distributions of short-term uncertainty in demand, wind, and solar forecasts that adapt to prevailing grid conditions. Machine learning derived estimates of forecast errors compare favorably to estimates based on incumbent methods. Reserves derived from machine learning are usually smaller than values derived using incumbent methods, which enables fuel savings during most hours. Machine learning reserves are generally larger than incumbent reserves during times of higher forecast error, potentially improving system reliability. Performance is tested using multi-stage production simulation modeling of the California Independent System Operator (CAISO) system. Machine learning reserves provide production cost and greenhouse gas (GHG) emission reductions of approximately 0.3% relative to historical 2019 requirements. Savings in the 2030 timeframe are highly dependent on battery storage capacity. At lower levels of battery capacity, savings of 0.4% from machine learning reserves are shown. Significant quantities of battery storage are expected to be added to meet California's resource adequacy needs and GHG reduction targets. Addition of these batteries saturate reserve needs and results in minimal within-hour balancing costs in 2030.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

Data-driven building energy modeling with feature selection and active learning for data predictive control

Three gaps impede the development of cost-effective and accurate data-driven building energy modeling/models (DBEM) for energy forecasting and predictive control strategies. Gap 1: data bias is common in building operation data, but this topic is hardly studied in DBEM; Gap 2: high data dimensionality is common in DBEM, but a systematic and scalable methodology is lacking to solve the problem; Gap 3: the interactions between data bias and high dimensionality have not been systematically studied for DBEM and predictive control in buildings. In this work, to address the three gaps mentioned above, we develop a framework that integrates active learning and feature selection for DBEM used for whole building data predictive control (or DPC, which is a branch of model predictive control). The framework provides a systematic methodology and automatic workflow that starts with raw data from building automation systems to the establishment of data-driven energy models for DPC controllers. The developed strategies and framework are evaluated in a virtual testbed based on EnergyPlus and BCVTB. Improved performance and reduced computational complexity are observed from the DBEM built with the developed framework, as well as the DPC controller based on that DBEM, indicating the effectiveness of the developed framework.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE↗

Occupant Preference-Aware Load Scheduling for Resilient Communities

The load scheduling of resilient communities in the islanded mode is subject to many uncertainties such as weather forecast errors and occupant behavior stochasticity. To date, it remains unclear how occupant preferences affect the effectiveness of the load scheduling of resilient communities. This paper proposes an occupant thermal preference-aware load scheduler for resilient communities operating in the islanded mode. First, key resilience indicators are selected to quantify its impacts on the load scheduling of a resilient community. A deterministic model predictive control-based load scheduling framework is adopted as the baseline. Then, a chance-constrained controller is proposed to address the occupant-induced uncertainty in room temperature setpoints. Finally, the chance-constrained controller is compared with the deterministic controller on a virtual community testbed based on a real-world net-zero energy community in Florida, U.S. Results have shown that the proposed chance-constrained controller performs better in terms of serving occupants’ thermal preference and the required battery sizes compared to the deterministic controller with the presence of the assumed stochastic occupant behavior. This work indicates that it is necessary to consider the stochasticity of the occupant behavior when designing optimal load schedulers for resilient communities.

Wang, Jing↗

Assessing Effects of Climate Change on Legacy Waste at the Enewetak Atoll

The Republic of the Marshall Islands (RMI) is in the central Pacific Ocean ~4,500 km west of Hawaii. The Enewetak Atoll, located in the northwest part of the RMI, was the site for 43 nuclear weapon tests between 1948 and 1958. Fallout and deposition from the tests contaminated the island surfaces, lagoon waters and sediment, and nearby ocean waters at the atoll. In the 1970s, a cleanup effort collected radioactive waste and placed it in the Cactus Crater on Runit Island (also called the Runit Dome). In December 2021, Congress directed the U.S. Department of Energy to study the impacts of climate change on the Runit Dome nuclear waste disposal site. Pacific Northwest National Laboratory (PNNL) assembled a multidisciplinary team of climate scientists, ocean modelers, environmental scientists, and health physicists to assess the likely effects of remaining radionuclides at the Enewetak Atoll. PNNL’s approach focused on effects of tropical cyclones that were postulated to mobilize and transport contaminated lagoon sediments and result in human and biota exposure. PNNL’s study estimated (1) the radionuclide source term, (2) the effects of climate change on severe storms, (3) mobilization and transport of radionuclides, and (4) radiation dose to humans and biota. Radionuclides in the lagoon and/or ocean waters of the Enewetak Atoll were characterized by the U.S. Atomic Energy Commission (AEC) in 1972, Woods Hole Oceanographic Institution in 2015, and Lawrence Livermore National Laboratory in 2018. The RMI Nationwide Radiological Study was conducted in the early 1990s for radionuclides remaining in island soils. The 1972 AEC survey remains the most comprehensive source of radionuclide data on lagoon sediments. Climate change modeling at a regional scale in the central Pacific Ocean is limited. PNNL climate scientists simulated severe historical storms postulated to occur both in a recent climate (2015) and in the future (2090) using the Advanced Research Weather Research and Forecasting (WRF-ARW) model, employing a pseudo-global-warming technique. A postulated complete, future failure of the Runit Dome was also considered. PNNL developed a high-resolution regional ocean hydrodynamics model covering the entire RMI extended economic zone using the Finite Volume Coastal Ocean Model (FVCOM). The FVCOM model was run using global reanalysis data for current climate and WRF-ARW simulation for the future climate. PNNL also developed a radionuclide fate and transport model using the FVCOM Integrated Compartment Model (FVCOM-ICM) to simulate the current and future mobilization and transport of radionuclides sorbed to lagoon sediments and the exchange of radionuclides between the water and sediment. FVCOM-ICM-predicted radionuclide concentrations were then used to estimate radiation dose to humans and biota at all islands of the Enewetak Atoll. Under current climate conditions, annual radiation exposures for the southern islands including Enewetak (Fred) and Medren (Elmer) were below the current U.S. standards. Radiation doses were somewhat elevated starting at Runit Island northward and westward to Enjebi Island (Janet). The islands in the northwest quadrant, particularly Bokoluo (Alice) and Bokombako (Belle), remain relatively contaminated. The islands in the southwestern quadrant have low contamination. The highest contribution to radiation doses comes from consumption of locally grown foods. Two radionuclides, 90Sr and 137Cs, contributed the greatest fraction for most terrestrial foods. In current climate conditions, the storms temporarily increased radionuclide concentrations in the lagoon waters, increasing the radiation dose slightly. In future conditions, doses are expected to be smaller, primarily because of the radioactive decay of the shorter-lived radioisotopes of 90Sr and 137Cs. This could make all islands in the far northwest of the atoll – except Bokombako (Belle) and perhaps Bokoluo (Alice) – suitable for residency. For the f

Prasad, Rajiv↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

2011 Atlanta, Georgia, Regional Travel Survey

The 2011 Regional Travel Survey collected trip data from households across 20 counties in and around Atlanta, Georgia, to improve regional travel demand forecasts. The survey was conducted by PTV NuStats, GeoStats, and PG Americas Inc. on behalf of the Atlanta Regional Commission. The goal was to collect trip data from a minimum of 10,000 households with a subsample of 1,000 households providing global positioning system (GPS) data. The GPS add-on consisted of two sample groups. The first sample group was provided with GPS devices to install in their personal vehicles (797 vehicles) to collect the speed and location of a vehicle during an assigned study period. The second sample group (1,653 participants) was provided with a wearable GPS device to collect the speed and location of an individual during an assigned study period. People participating in the wearable add-on part of the study were chosen because their travel diaries reported use of public transit in day-to-day travel. Each GPS participant was grouped into either the spring phase (March to May 2011) or the fall phase (July to September 2011), and data were recorded for a maximum of seven days for vehicle units and three days for wearable units.

1Hz data↗

City-Scale Building Anthropogenic Heating during Heat Waves

More frequent and longer duration heat waves have been observed worldwide and are recognized as a serious threat to human health and the stability of electrical grids. Past studies have identified a positive feedback between heat waves and urban heat island effects. Anthropogenic heat emissions from buildings have a crucial impact on the urban environment, and hence it is critical to understand the interactive effects of urban microclimate and building heat emissions in terms of the urban energy balance. Here we developed a coupled-simulation approach to quantify these effects, mapping urban environmental data generated by the mesoscale Weather Research and Forecasting (WRF) coupled to Urban Canopy Model (UCM) to urban building energy models (UBEM). We conducted a case study in the city of Los Angeles, California, during a five-day heat wave event in September 2009. We analyzed the surge in city-scale building heat emission and energy use during the extreme heat event. We first simulated the urban microclimate at a high resolution (500 m by 500 m) using WRF-UCM. We then generated grid-level building heat emission profiles and aggregated them using prototype building energy models informed by spatially disaggregated urban land use and urban building density data. The spatial patterns of anthropogenic heat discharge from the building sector were analyzed, and the quantitative relationship with weather conditions and urban land-use dynamics were assessed at the grid level. The simulation results indicate that the dispersion of anthropogenic heat from urban buildings to the urban environment increases by up to 20% on average and varies significantly, both in time and space, during the heat wave event. The heat dispersion from the air-conditioning heat rejection contributes most (86.5%) of the total waste heat from the buildings to the urban environment. We also found that the waste heat discharge in inland, dense urban districts is more sensitive to extreme events than it is in coastal or suburban areas. The generated anthropogenic heat profiles can be used in urban microclimate models to provide a more accurate estimation of urban air temperature rises during heat waves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗