Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Characterizing non-Markovian and coherent errors in quantum simulation

Quantum simulation of many-body systems, particularly using ultracold atoms and trapped ions, presents a unique form of quantum control—it is a direct implementation of a multi-qubit gate generated by the Hamiltonian. As a consequence, it also faces a unique challenge in terms of benchmarking, because the well-established gate benchmarking techniques are unsuitable for this form of quantum control. Here we show that the symmetries of the target many-body Hamiltonian can be used not only to benchmark but to characterize experimental errors in the quantum simulation. We use our results to develop protocols to characterize these errors, which can be implemented using state-of-the-art technology. We consider two forms of errors: (i) unitary errors arising out of systematic errors in the applied Hamiltonian and (ii) canonical non-Markovian errors arising out of random shot-to-shot fluctuations in the applied Hamiltonian. We show that the dynamics of the expectation value of the target Hamiltonian itself, which is ideally constant in time, can be used to characterize these errors. In the presence of errors, the expectation value of the target Hamiltonian shows a characteristic thermalization dynamics, when it satisfies the operator thermalization hypothesis (OTH). That is, an oscillation in the short time followed by relaxation to a steady-state value in the long time limit. We show that while the steady-state value can be used to characterize the coherent errors, the amplitude of the oscillations can be used to estimate the non-Markovian errors. We prove a sandwich theorem to establish a linear relation between the amplitude of the oscillations and the magnitude of the non-Markovian errors. Moreover, by varying the initial state, we show that the steady state values can be used to completely construct the generator of the coherent errors. Using these results, we develop two experimental protocols to characterize the unitary errors based on these results, one of which requires single-qubit addressing and the other one doesn't. We also develop a protocol to characterize non-Markovian errors. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements and Model Improvement: Insight into NWP Model Error Using Doppler Lidar and Other WFIP2 Measurement Systems

Abstract Doppler-lidar wind-profile measurements at three sites were used to evaluate NWP model errors from two versions of NOAA’s 3-km-grid HRRR model, to see whether updates in the latest version 4 reduced errors when compared against the original version 1. Nested (750-m grid) versions of each were also tested to see how grid spacing affected forecast skill. The measurements were part of the field phase of the Second Wind Forecasting Improvement Project (WFIP2), an 18-month deployment into central Oregon–Washington, a major wind-energy-producing region. This study focuses on errors in simulating marine intrusions, a summertime, 600–800-m-deep, regional sea-breeze flow found to generate large errors. HRRR errors proved to be complex and site dependent. The most prominent error resulted from a premature drop in modeled marine-intrusion wind speeds after local midnight, when lidar-measured winds of greater than 8 m s −1 persisted through the next morning. These large negative errors were offset at low levels by positive errors due to excessive mixing, complicating the interpretation of model “improvement,” such that the updates to the full-scale versions produced mixed results, sometimes enhancing but sometimes degrading model skill. Nesting consistently improved model performance, with version 1’s nest producing the smallest errors overall. HRRR’s ability to represent the stages of sea-breeze forcing was evaluated using radiation budget, surface-energy balance, and near-surface temperature measurements available during WFIP2. The significant site-to-site differences in model error and the complex nature of these errors mean that field-measurement campaigns having dense arrays of profiling sensors are necessary to properly diagnose and characterize model errors, as part of a systematic approach to NWP model improvement. Significance Statement Dramatic increases in NWP model skill will be required over the coming decades. This paper describes the role of major deployments of accurate profiling sensors in achieving that goal and presents an example from the Second Wind Forecast Improvement Program (WFIP2). Wind-profile data from scanning Doppler lidars were used to evaluate two versions of HRRR, the original and an updated version, and nested versions of each. This study focuses on the ability of updated HRRR versions to improve upon predicting a regional sea-breeze flow, which was found to generate large errors by the original HRRR. Updates to the full-scale HRRR versions produced mixed results, but the finer-mesh versions consistently reduced model errors.

Meteorology & Atmospheric Sciences↗

PCR-Induced Transitions Are the Major Source of Error in Cleaned Ultra-Deep Pyrosequencing Data

Ultra-deep pyrosequencing (UDPS) is used to identify rare sequence variants. The sequence depth is influenced by several factors including the error frequency of PCR and UDPS. This study investigated the characteristics and source of errors in raw and cleaned UDPS data. UDPS of a 167-nucleotide fragment of the HIV-1 SG3Δenv plasmid was performed on the Roche/454 platform. The plasmid was diluted to one copy, PCR amplified and subjected to bidirectional UDPS on three occasions. The dataset consisted of 47,693 UDPS reads. Raw UDPS data had an average error frequency of 0.30% per nucleotide site. Most errors were insertions and deletions in homopolymeric regions. We used a cleaning strategy that removed almost all indel errors, but had little effect on substitution errors, which reduced the error frequency to 0.056% per nucleotide. In cleaned data the error frequency was similar in homopolymeric and non-homopolymeric regions, but varied considerably across sites. These site-specific error frequencies were moderately, but still significantly, correlated between runs (r = 0.15–0.65) and between forward and reverse sequencing directions within runs (r = 0.33–0.65). Furthermore, transition errors were 48-times more common than transversion errors (0.052% vs. 0.001%; p<0.0001). Collectively the results indicate that a considerable proportion of the sequencing errors that remained after data cleaning were generated during the PCR that preceded UDPS. A majority of the sequencing errors that remained after data cleaning were introduced by PCR prior to sequencing, which means that they will be independent of platform used for next-generation sequencing. The transition vs. transversion error bias in cleaned UDPS data will influence the detection limits of rare mutations and sequence variants.

59 BASIC BIOLOGICAL SCIENCES↗

A parametric study of the impact of various error contributions on the flux distribution of a solar dish concentrator.

Dish concentrators can produce highly concentrated flux for the operation of an engine, a chemical process, or other energy converter. The high concentration allows a small aperture to control thermal losses, and permits high temperature processes at the focal point. A variety of optical errors can influence the flux pattern both at the aperture and at the absorber surface. Impacts of these errors can be lost energy (intercept losses), aperture compromise (increased size to accommodate flux), high peak fluxes (leading to part failure or life reduction), and improperly positioned flux also leading to component failure. Optical errors can include small scale facet errors ('waviness'), facet shape errors, alignment (facet pointing) errors, structural deflections, and tracking errors. The errors may be random in nature, or may be systematic. The various sources of errors are often combined in a 'root-mean-squared' process to present a single number as an 'error budget'. However, this approach ignores the fact that various errors can influence the performance in different ways, and can mislead the designer, leading to component damage in a system or poor system performance. In this paper, we model a hypothetical radial gore dish system using Sandia's CIRCE2 optical code. We evaluate the peak flux and incident power through the aperture and onto various parts of the receiver cavity. We explore the impact of different error sources on the character of the flux pattern, and demonstrate the limitations of lumping all of the errors into a single error budget.

14 SOLAR ENERGY↗

SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error

Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed without the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-789: Validation of 3DVH Accuracy On Quantifying Delivery Errors Based On Clinical Relevant DVH Metrics

Purpose: Detection of treatment delivery errors is important in radiation therapy. However, accurate quantification of delivery errors is also of great importance. This study aims to evaluate the 3DVH software’s ability to accurately quantify delivery errors. Methods: Three VMAT plans (prostate, H&N and brain) were randomly chosen for this study. First, we evaluated whether delivery errors could be detected by gamma evaluation. Conventional per-beam IMRT QA was performed with the ArcCHECK diode detector for the original plans and for the following modified plans: (1) induced dose difference error up to ±4.0% and (2) control point (CP) deletion (3 to 10 CPs were deleted) (3) gantry angle shift error (3 degree uniformly shift). 2D and 3D gamma evaluation were performed for all plans through SNC Patient and 3DVH, respectively. Subsequently, we investigated the accuracy of 3DVH analysis for all cases. This part evaluated, using the Eclipse TPS plans as standard, whether 3DVH accurately can model the changes in clinically relevant metrics caused by the delivery errors. Results: 2D evaluation seemed to be more sensitive to delivery errors. The average differences between ECLIPSE predicted and 3DVH results for each pair of specific DVH constraints were within 2% for all three types of error-induced treatment plans, illustrating the fact that 3DVH is fairly accurate in quantifying the delivery errors. Another interesting observation was that even though the gamma pass rates for the error plans are high, the DVHs showed significant differences between original plan and error-induced plans in both Eclipse and 3DVH analysis. Conclusion: The 3DVH software is shown to accurately quantify the error in delivered dose based on clinically relevant DVH metrics, where a conventional gamma based pre-treatment QA might not necessarily detect.

60 APPLIED LIFE SCIENCES↗

SU-F-J-208: Prompt Gamma Imaging-Based Prediction of Bragg Peak Position for Realistic Treatment Error Scenarios

Purpose: To quantify the accuracy in predicting the Bragg peak position using simulated in-room measurements of prompt gamma (PG) emissions for realistic treatment error scenarios that combine several sources of errors. Methods: Prompt gamma measurements by a knife-edge slit camera were simulated using an experimentally validated analytical simulation tool. Simulations were performed, for 143 treatment error scenarios, on an anthropomorphic phantom and a pencil beam scanning plan for nasal cavity. Three types of errors were considered: translation along each axis, rotation around each axis, and CT-calibration errors with magnitude ranging respectively, between −3 and 3 mm, −5 and 5 degrees, and between −5 and +5%. We investigated the correlation between the Bragg peak (BP) shift and the horizontal shift of PG profiles. The shifts were calculated between the planned (reference) position and the position by the error scenario. The prediction error for one spot was calculated as the absolute difference between the PG profile shift and the BP shift. Results: The PG shift was significantly and strongly correlated with the BP shift for 92% of the cases (p<0.0001, Pearson correlation coefficient R>0.8). Moderate but significant correlations were obtained for all cases that considered only CT-calibration errors and for 1 case that combined translation and CT-errors (p<0.0001, R ranged between 0.61 and 0.8). The average prediction errors for the simulated scenarios ranged between 0.08±0.07 and 1.67±1.3 mm (grand mean 0.66±0.76 mm). The prediction error was moderately correlated with the value of the BP shift (p=0, R=0.64). For the simulated scenarios the average BP shift ranged between −8±6.5 mm and 3±1.1 mm. Scenarios that considered combinations of the largest treatment errors were associated with large BP shifts. Conclusion: Simulations of in-room measurements demonstrate that prompt gamma profiles provide reliable estimation of the Bragg peak position for complex error scenarios. Yafei Xing and Luiza Bondar are funded by BEWARE grants from the Walloon Region. The work presents simulations results for a prompt gamma camera prototype developed by IBA.

60 APPLIED LIFE SCIENCES↗

SU-F-T-471: Simulated External Beam Delivery Errors Detection with a Large Area Ion Chamber Transmission Detector

Purpose: The Integral Quality Monitor (IQM), developed by iRT Systems GmbH (Koblenz, Germany) is a large-area, linac-mounted ion chamber used to monitor photon fluence during patient treatment. Our previous work evaluated the change of the ion chamber’s response to deviations from static 1×1 cm2 and 10×10 cm2 photon beams and other characteristics integral to use in external beam detection. The aim of this work is to simulate two external beam radiation delivery errors, quantify the detection of simulated errors and evaluate the reduction in patient harm resulting from detection. Methods: Two well documented radiation oncology delivery errors were selected for simulation. The first error was recreated by modifying a wedged whole breast treatment, removing the physical wedge and calculating the planned dose with Pinnacle TPS (Philips Radiation Oncology Systems, Fitchburg, WI). The second error was recreated by modifying a static-gantry IMRT pharyngeal tonsil plan to be delivered in 3 unmodulated fractions. A radiation oncologist evaluated the dose for simulated errors and predicted morbidity and mortality commiserate with the original reported toxicity, indicating that reported errors were approximately simulated. The ion chamber signal of unmodified treatments was compared to the simulated error signal and evaluated in Pinnacle TPS again with radiation oncologist prediction of simulated patient harm. Results: Previous work established that transmission detector system measurements are stable within 0.5% standard deviation (SD). Errors causing signal change greater than 20 SD (10%) were considered detected. The whole breast and pharyngeal tonsil IMRT simulated error increased signal by 215% and 969%, respectively, indicating error detection after the first fraction and IMRT segment, respectively. Conclusion: The transmission detector system demonstrated utility in detecting clinically significant errors and reducing patient toxicity/harm in simulated external beam delivery. Future work will evaluate detection of other smaller magnitude delivery errors.

60 APPLIED LIFE SCIENCES↗

Analytic error analysis of cross section interpolation methods in nodal diffusion codes - II: Numerical results

This paper is the second part of a two-part paper that documents the numerical results for the partial derivatives model presented in part I. In this paper, we derive the error bounds for the analytical point-wise error expression and verify our bounds with numerical experiments. The point-wise error expressions make available, and bound, the sources that contribute to the total error of the interpolated cross section in terms of the Lagrange interpolation errors and the model form error. MPACT is used to generate two-group homogenized cross sections for Westinghouse's AP1000 Region 4 lattice to evaluate the accuracy of the bounds. Error bounds calculated over a grid are compared to numerical data for uni-variate and multi-variate interpolation. The point-wise error bounds of a typical case matrix - two branches in each state variable - are displayed for bi-variate interpolation in the state variables: moderator density, fuel temperature, and boron concentration. The error bounds are shown to be highly accurate compared to numerical results, and in accordance with the underlying physics. We then discuss and show how the sources of error contribute to the total error, and consider the improvement of each error source. Finally, we mention future work such as propagating our cross section error bounds through a reactivity calculation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A posteriori error estimators for the discrete ordinates approximation of the one-speed neutron transport equation

When calculating numerical solutions of the neutron transport equation it is important to have a measure of the accuracy of the solution. As the true solution is generally not known, a suitable estimation of the error must be made. The steady state transport equation possesses discretization errors in all its independent variables: angle, energy and space. In this work only spatial discretization errors are considered. An exact transport solution, in which the degree of regularity of the exact flux across the singular characteristic is controlled, is manufactured to determine the numerical solutions true discretization error. This solution is then projected onto a Legendre polynomial space in order to form an exact solution on the same basis space as the numerical solution, Discontinuous Galerkin Finite Element Method (DGFEM), to enable computation of the true error. Over a series of test problems the true error is compared to the error estimated by: Ragusa and Wang (RW), residual source (LER) and cell discontinuity estimators (JD). The validity and accuracy of the considered estimators are primarily assessed by considering the effectivity index and global L2 norm of the error. In general RW excels at approximating the true error distribution but usually under-estimates its magnitude; the LER estimator emulates the true error distribution but frequently over-estimates the magnitude of the true error; the JD estimator poorly captures the true error distribution and generally under-estimates the error about singular characteristics but over-estimates it elsewhere. (authors)

97 MATHEMATICS AND COMPUTING↗

Quality Assurance Analysis of a Large Multicenter Practice: Does Increased Complexity of Intensity-Modulated Radiotherapy Lead to Increased Error Frequency?

Purpose: Error reduction is an important concern in clinical medicine. Intensity-modulated radiotherapy (IMRT) is an important advancement in radiation oncology that increases the complexity of treatment, potentially increasing the error risk. We studied the frequency and severity of errors in a large multicenter practice to ascertain the impact of quality improvement interventions over time, IMRT, and type of practice. Methods and Materials: We analyzed prospective data from three academic and 16 community practice sites with 24,775 courses of radiotherapy (9,210 IMRT courses and 15,565 non-IMRT) between January 2006 and December 2009. All IMRT treatment was performed using one centralized dose planning center for all sites. Results: We prospectively identified various errors or potential errors in 0.14 % vs. 0.40 % of the IMRT vs. non-IMRT courses (13/9,210 vs. 62/15,565, p = 0.0004) and excluding potential errors: 0.03 % for IMRT vs. 0.21% for non-IMRT. We developed the Clinical Radiotherapy Error Severity Scale (CRESS) to classify error severity from 1 to 10, with 1 to 3 for potential or completely correctable errors, 4 to 5 for dose variations <5%, and 6 to 10 for dose variations >5%. Multivariate analyses of CRESS values, severity >4, and any error (including potential) correlated significantly reduced errors with IMRT (p = 0.0001-0.0024) but found no significant difference between the academic and community practice sites and no change in error frequency over time despite implementation of 39 system-wide policy changes by the centralized quality improvement committee. Conclusions: Despite the increase in complexity with IMRT compared with conventional radiotherapy, it can be delivered with reduced error frequency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compiler-Directed Soft Error Detection and Recovery to Avoid DUE and SDC via Tail-DMR

This article presents Clover, a compiler-directed soft error detection and recovery scheme for lightweight soft error resilience. The compiler carefully generates soft-error-tolerant code based on idempotent processing without explicit checkpoints. During program execution, Clover relies on a small number of acoustic wave detectors deployed in the processor to identify soft errors by sensing the wave made by a particle strike. To cope with DUEs (detected unrecoverable errors) caused by the sensing latency of error detection, Clover leverages a novel selective instruction duplication technique called tail-DMR (dual modular redundancy) that provides a region-level error containment. Once a soft error is detected by either the sensors or the tail-DMR, Clover takes care of the error as in the case of exception handling. To recover from the error, Clover simply redirects program control to the beginning of the code region where the error is detected. The experimental results demonstrate that the average runtime overhead is only 26%, which is a 75% reduction compared to that of the state-of-the-art soft error resilience technique. In addition, this article evaluates an alternative technique called tail-wait, comparing it to Clover. According to the evaluation with the different processor configurations and the various error detection latencies, Clover turns out to be a superior technique, achieving 1.06 to 3.49× speedup over the tail-wait.

Computer Science↗

Coping with silent and fail-stop errors at scale by combining replication and checkpointing

This paper provides a model and an analytical study of replication as a technique to cope with silent errors, as well as a mixture of both silent and fail-stop errors on large-scale platforms. Compared with fail-stop errors that are immediately detected when they occur, silent errors require a detection mechanism. To detect silent errors, many application-specific techniques are available, either based on algorithms (e.g., ABFT), invariant preservation or data analytics, but replication remains the most transparent and least intrusive technique. We explore the right level (duplication, triplication or more) of replication for two frameworks: (i) when the platform is subject to only silent errors, and (ii) when the platform is subject to both silent and fail-stop errors. A higher level of replication is more expensive in terms of resource usage but enables to tolerate more errors and to even correct some errors, hence there is a trade-off to be found. Replication is combined with checkpointing and comes with two flavors: process replication and group replication. Process replication applies to message-passing applications with communicating processes. Each process is replicated, and the platform is composed of process pairs, or triplets. Group replication applies to black-box applications, whose parallel execution is replicated several times. The platform is partitioned into two halves (or three thirds). In both scenarios, results are compared before each checkpoint, which is taken only when both results (duplication) or two out of three results (triplication) coincide. Otherwise, one or more silent errors have been detected, and the application rolls back to the last checkpoint, as well as when fail-stop errors have struck. We provide a detailed analytical study for all of these scenarios, with formulas to decide, for each scenario, the optimal parameters as a function of the error rate, checkpoint cost, and platform size. We also report a set of extensive simulation results that nicely corroborates the analytical model.

Checkpointing↗

A Comprehensive Quality Assurance Program for Personnel and Procedures in Radiation Oncology: Value of Voluntary Error Reporting and Checklists

Purpose: This report describes the value of a voluntary error reporting system and the impact of a series of quality assurance (QA) measures including checklists and timeouts on reported error rates in patients receiving radiation therapy. Methods and Materials: A voluntary error reporting system was instituted with the goal of recording errors, analyzing their clinical impact, and guiding the implementation of targeted QA measures. In response to errors committed in relation to treatment of the wrong patient, wrong treatment site, and wrong dose, a novel initiative involving the use of checklists and timeouts for all staff was implemented. The impact of these and other QA initiatives was analyzed. Results: From 2001 to 2011, a total of 256 errors in 139 patients after 284,810 external radiation treatments (0.09% per treatment) were recorded in our voluntary error database. The incidence of errors related to patient/tumor site, treatment planning/data transfer, and patient setup/treatment delivery was 9%, 40.2%, and 50.8%, respectively. The compliance rate for the checklists and timeouts initiative was 97% (P<.001). These and other QA measures resulted in a significant reduction in many categories of errors. The introduction of checklists and timeouts has been successful in eliminating errors related to wrong patient, wrong site, and wrong dose. Conclusions: A comprehensive QA program that regularly monitors staff compliance together with a robust voluntary error reporting system can reduce or eliminate errors that could result in serious patient injury. We recommend the adoption of these relatively simple QA initiatives including the use of checklists and timeouts for all staff to improve the safety of patients undergoing radiation therapy in the modern era.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose variations caused by setup errors in intracranial stereotactic radiotherapy: A PRESAGE study

Stereotactic radiotherapy (SRT) requires tight margins around the tumor, thus producing a steep dose gradient between the tumor and the surrounding healthy tissue. Any setup errors might become clinically significant. To date, no study has been performed to evaluate the dosimetric variations caused by setup errors with a 3-dimensional dosimeter, the PRESAGE. This research aimed to evaluate the potential effect that setup errors have on the dose distribution of intracranial SRT. Computed tomography (CT) simulation of a CIRS radiosurgery head phantom was performed with 1.25-mm slice thickness. An ideal treatment plan was generated using Brainlab iPlan. A PRESAGE was made for every treatment with and without errors. A prescan using the optical CT scanner was carried out. Before treatment, the phantom was imaged using Brainlab ExacTrac. Actual radiotherapy treatments with and without errors were carried out with the Novalis treatment machine. Postscan was performed with an optical CT scanner to analyze the dose irradiation. The dose variation between treatments with and without errors was determined using a 3-dimensional gamma analysis. Errors are clinically insignificant when the passing ratio of the gamma analysis is 95% and above. Errors were clinically significant when the setup errors exceeded a 0.7-mm translation and a 0.5° rotation. The results showed that a 3-mm translation shift in the superior-inferior (SI), right-left (RL), and anterior-posterior (AP) directions and 2° couch rotation produced a passing ratio of 53.1%. Translational and rotational errors of 1.5 mm and 1°, respectively, generated a passing ratio of 62.2%. Translation shift of 0.7 mm in the directions of SI, RL, and AP and a 0.5° couch rotation produced a passing ratio of 96.2%. Preventing the occurrences of setup errors in intracranial SRT treatment is extremely important as errors greater than 0.7 mm and 0.5° alter the dose distribution. The geometrical displacements affect dose delivery to the tumor and the surrounding normal tissues.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automated contouring error detection based on supervised geometric attribute distribution models for radiation therapy: A general strategy

Purpose: One of the most critical steps in radiation therapy treatment is accurate tumor and critical organ-at-risk (OAR) contouring. Both manual and automated contouring processes are prone to errors and to a large degree of inter- and intraobserver variability. These are often due to the limitations of imaging techniques in visualizing human anatomy as well as to inherent anatomical variability among individuals. Physicians/physicists have to reverify all the radiation therapy contours of every patient before using them for treatment planning, which is tedious, laborious, and still not an error-free process. In this study, the authors developed a general strategy based on novel geometric attribute distribution (GAD) models to automatically detect radiation therapy OAR contouring errors and facilitate the current clinical workflow. Methods: Considering the radiation therapy structures’ geometric attributes (centroid, volume, and shape), the spatial relationship of neighboring structures, as well as anatomical similarity of individual contours among patients, the authors established GAD models to characterize the interstructural centroid and volume variations, and the intrastructural shape variations of each individual structure. The GAD models are scalable and deformable, and constrained by their respective principal attribute variations calculated from training sets with verified OAR contours. A new iterative weighted GAD model-fitting algorithm was developed for contouring error detection. Receiver operating characteristic (ROC) analysis was employed in a unique way to optimize the model parameters to satisfy clinical requirements. A total of forty-four head-and-neck patient cases, each of which includes nine critical OAR contours, were utilized to demonstrate the proposed strategy. Twenty-nine out of these forty-four patient cases were utilized to train the inter- and intrastructural GAD models. These training data and the remaining fifteen testing data sets were separately employed to test the effectiveness of the proposed contouring error detection strategy. Results: An evaluation tool was implemented to illustrate how the proposed strategy automatically detects the radiation therapy contouring errors for a given patient and provides 3D graphical visualization of error detection results as well. The contouring error detection results were achieved with an average sensitivity of 0.954/0.906 and an average specificity of 0.901/0.909 on the centroid/volume related contouring errors of all the tested samples. As for the detection results on structural shape related contouring errors, an average sensitivity of 0.816 and an average specificity of 0.94 on all the tested samples were obtained. The promising results indicated the feasibility of the proposed strategy for the detection of contouring errors with low false detection rate. Conclusions: The proposed strategy can reliably identify contouring errors based upon inter- and intrastructural constraints derived from clinically approved contours. It holds great potential for improving the radiation therapy workflow. ROC and box plot analyses allow for analytically tuning of the system parameters to satisfy clinical requirements. Future work will focus on the improvement of strategy reliability by utilizing more training sets and additional geometric attribute constraints.

60 APPLIED LIFE SCIENCES↗

TU-G-BRD-08: In-Vivo EPID Dosimetry: Quantifying the Detectability of Four Classes of Errors

Purpose: EPID dosimetry is an emerging method for treatment verification and QA. Given that the in-vivo EPID technique is in clinical use at some centers, we investigate the sensitivity and specificity for detecting different classes of errors. We assess the impact of these errors using dose volume histogram endpoints. Though data exist for EPID dosimetry performed pre-treatment, this is the first study quantifying its effectiveness when used during patient treatment (in-vivo). Methods: We analyzed 17 patients; EPID images of the exit dose were acquired and used to reconstruct the planar dose at isocenter. This dose was compared to the TPS dose using a 3%/3mm gamma criteria. To simulate errors, modifications were made to treatment plans using four possible classes of error: 1) patient misalignment, 2) changes in patient body habitus, 3) machine output changes and 4) MLC misalignments. Each error was applied with varying magnitudes. To assess the detectability of the error, the area under a ROC curve (AUC) was analyzed. The AUC was compared to changes in D99 of the PTV introduced by the simulated error. Results: For systematic changes in the MLC leaves, changes in the machine output and patient habitus, the AUC varied from 0.78–0.97 scaling with the magnitude of the error. The optimal gamma threshold as determined by the ROC curve varied between 84–92%. There was little diagnostic power in detecting random MLC leaf errors and patient shifts (AUC 0.52–0.74). Some errors with weak detectability had large changes in D99. Conclusion: These data demonstrate the ability of EPID-based in-vivo dosimetry in detecting variations in patient habitus and errors related to machine parameters such as systematic MLC misalignments and machine output changes. There was no correlation found between the detectability of the error using the gamma pass rate, ROC analysis and the impact on the dose volume histogram. Funded by grant R18HS022244 from AHRQ.

60 APPLIED LIFE SCIENCES↗