At least 163 records · Page 9

Highlights from the Postirradiation Examination of AFC-3A and AFC-3B

Highlights from the postirradiation examination of the AFC-3A and AFC-3B irradiation test are presented. Baseline non-destructive and destructive examinations of these tests have been completed at this time. Results from visual examination, neutron radiography, gamma spectrometry, dimensional inspection, fission gas release, chemical burnup analysis, and optical microscopy have been collected. All the rodlets from these irradiations appear to have performed well during irradiation. Baseline PIE has been completed on rodlets from AFC- 3A, and AFC-3B. This includes visual exams, neutron radiography, gamma spectrometry. dimensional inspection, fission gas release evaluation, optical microscopy. microhardness evaluation. and chemical analysis. The results compiled here are a sampling of the full results. Baseline PIE provides an engineering or macroscopic scale evaluation of fuel performance and prepares samples for a more detailed phenomenological study of observed performance. Advanced PIE techniques are desired to obtain microscopic elemental and structural information both in the fuel, in the cladding, and in the interface where the composition of the FCCI layer is of great interest. The AFC-3 tests do appear to have performed roughly as designed during the irradiation. The FCCI behavior of Mo alloy metallic fuel versus Zr alloy metallic fuel has been confirmed. Results from this irradiation such as the FCCI observed in AFC-3A R1 and AFC-3A R2 can be used to eliminate Mo alloys as a choice in future irradiations where ultra-high burnup is a stated goal. Annular fuels are a preferred method for many high burnup core designs. The redistribution behavior of the annular U-Zr alloys should be studied further to better understand how this might impact high burnup annular fuel performance. The thermal bonding between annular fuel and cladding should also be studied further as there appear to be localized areas of FCCI forming in both AFC-3A R4 and AFC-3B R2, while no FCCI was observed in the Zr-based Na-bonded or Mo-based low smear density Na-bonded fuel. The performance of the low smear density. solid fuels is less clear. The neutron radiography and optical microscopy cross sections suggest the fuel is not forming a radially symmetric structure which may be causing undesirable localized temperature variations. Further study both by electron microscopy and by simulation to evaluate the implications of the non-symmetric fuel form are needed to better understand whether this fuel form merits further study under irradiation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Key results from irradiation and post-irradiation examination of AGR-1 UCO Triso fuel - 18576

The AGR-1 irradiation experiment was performed as the first test of tri-structural isotropic (TRISO) fuel in the US Advanced Gas Reactor Fuel Development and Qualification Program. The experiment consisted of 72 right cylinder fuel compacts containing approximately 3 x 10{sup 5} coated fuel particles with uranium oxide/uranium carbide (UCO) fuel kernels. The fuel was irradiated in the Advanced Test Reactor for a total of 620 effective full power days. Fuel burnup ranged from 11.3 to 19.6% fissions per initial metal atom and time average, volume average irradiation temperatures of the individual compacts ranged from 955 to 1136 deg. C. This paper focuses on key results from the irradiation and post-irradiation examination, which revealed a robust fuel with excellent performance characteristics under the conditions tested and have significantly improved the understanding of UCO coated particle fuel irradiation behavior. The fuel exhibited zero TRISO coating failures (failure of all three dense coating layers) during irradiation and post-irradiation safety testing at temperatures up to 1700 deg. C. Advanced PIE methods have allowed particles with SiC coating failure that were discovered to be present in a very-low population to be isolated and meticulously examined, which has elucidated the specific causes of SiC failure in these specimens. The level of fission product release from the fuel during irradiation and post-irradiation safety testing has been studied in detail. Results indicated very low release of krypton and cesium through intact SiC and modest release of europium and strontium, while also confirming the potential for significant silver release through the coatings depending on irradiation conditions. Focused study of fission products within the coating layers of irradiated particles down to nanometer length scales has provided new insights into fission product transport through the coating layers and the role various fission products may have on coating integrity. The broader implications of these results and the application of lessons learned from AGR-1 to fuel fabrication and post-irradiation examination for subsequent fuel irradiation experiments as part of the US fuel program are also discussed. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Destructive Examination Protocol for 3013-Container-Package Storing Plutonium-Bearing Materials

The 3013-container-package consists of a convenience, inner and outer container and is used for long-term storage of plutonium-bearing materials. A destructive examination (DE) protocol has been developed to examine the container package visually and with microscopic aid to find any corrosion conditions that could result in the loss of the integrity of the container package over its lifetime. The DE protocol contains three main steps: initial container examination, helium (He) leak testing, and detailed imaging and analysis of the inner container closure weld region (ICCWR). The ICCWR has been determined to be bounding, defined as exhibiting worst case conditions for stress corrosion cracking (SCC) of the inner container. To assess SCC in the ICCWR, the inner container lid is cut into quarters and the weld and He-leak testing gasket are removed. Then a citric acid wash is performed to remove adherent chlorides from the ICCWR. The wash is then sent for analysis to determine the concentration of chlorides in the ICCWR. While the analysis for chloride concentration is being performed, the quarter sections are further sectioned into 1/8th subsections by cutting each section in half. These subsections are washed using nitric acid to remove corrosion products. Then each subsection is imaged using a Wide Angle 3-D Measurement System (WAMS). After analysis of microscope images for potential SCC, additional imaging can be performed, including subsurface imaging. After review, a determination is made of whether the container integrity may potentially affect the safe storage of the material.

container↗

US RERTR FUEL DEVELOPMENT POST IRRADIATION EXAMINATION RESULTS

Post irradiation examinations of irradiated RERTR plate type fuel at the Idaho National Laboratory have led to in depth characterization of fuel behavior and performance. Both destructive and non-destructive examination capabilities at the Hot Fuels Examination Facility (HFEF) as well as recent results obtained are discussed herein. New equipment as well as more advanced techniques are also being developed to further advance the investigation into the performance of the high density U-Mo fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A slice of an aluminum particle: Examining grains, strain and reactivity

The Combustion Institute Micron-scale aluminum (Al) particles are plagued by incomplete combustion that inhibits their reactivity. One approach to improving reactivity is to anneal Al particles to increase dilatational (volumetric) strain which has also been linked to increased combustion performance. While optimal annealing temperatures have been identified (roughly 300 °C), little is known about cooling rate effects on particle combustion performance. This study examines the effect of quenching after annealing Al microparticles to 100, 200 and 300 °C on intra-particle dilatational strain and reactivity. Synchrotron X-ray diffraction analysis of the particles reveals the cooling rates in the range from 0.007 to 0.38 K/s have little effect on the dilatational strain of the aluminum-core, alumina-shell particles. The annealed and quenched Al particles were then combined with a metal oxidizer (copper oxide) to examine reactivity. Flame propagation experiments follow the same trend: flame speeds are unchanged until a critical annealing temperature of 300 °C is reached and performance is maintained for each annealing temperature regardless of cooling rate. These results show that altering the mechanical properties and combustion performance of Al particles is strongly dependent on the annealing temperature and unchanged with variation in cooling rate. The contributions from elastic and plastic deformation mechanisms on strain are also considered and additional experimental results are shown on the microstructure of an Al particle. Focused ion beam milling of an Al particle to electron transparency was combined with transmission electron microscope imaging in order to examine the microstructure of the Al particles. This confirmed that the Al microparticles have a polycrystalline structure shown by grains all exceeding 100 nm in size.

36 MATERIALS SCIENCE↗

Environmental cadmium and lead exposures and age-related macular degeneration in U.S. adults: The National Health and Nutrition Examination Survey 2005 to 2008

Age-related macular degeneration (AMD) is a complex disease resulting from the interplay of genetic predisposition and environmental exposures, and has been linked to oxidative stress and inflammatory mechanisms. Lead and cadmium can accumulate in human retinal tissues and may damage the retina through oxidative stress, and may thereby play a role in the development of AMD. We examined associations between blood lead, blood cadmium, and urinary cadmium concentrations and the presence of AMD in 5390 participants aged 40 years and older with blood lead and blood cadmium measures and a subsample of 1548 with urinary cadmium measures in the 2005–2008 National Health and Nutrition Examination Surveys. AMD was identified by grading retinal photographs with a modification of the Wisconsin Age-Related Maculopathy Grading System. The weighted prevalence of AMD was 6.6% (n=426). Controlling for age, gender, race/ethnicity, education and body mass index, adults in the highest blood cadmium quartile had higher odds of AMD compared to the lowest quartile (odds ratio [OR], 1.56; 95% CI, 1.02–2.40), with a significant trend across quartiles (p-trend=0.02). After further adjustment for pack-years of cigarette smoking, estimates were somewhat attenuated (OR, 1.43; 95% CI, 0.91–2.27; p-trend=0.08). Similar associations were found with urinary cadmium. The association between urinary cadmium and AMD was stronger in non-Hispanic whites (NHW) than in non-Hispanic blacks (NHB) (OR, 3.31; 95% CI, 1.37–8.01 for levels above versus below the median among NHW; OR,1.45; 95% CI, 0.40–5.32 for levels above versus below the median among NHB; p-interaction=0.03). We found no association between blood lead levels and AMD. Higher cadmium body burden may increase risk of AMD, particularly among non-Hispanic white individuals; however, additional studies are needed before firm conclusions can be drawn. - Highlights: • We examined the association of cadmium and lead with age-related macular degeneration (AMD) in U.S. adults. • Cadmium in both blood and urine was borderline significantly associated with the risk of AMD. • Blood lead was not associated with the risk of AMD. • The association between urine cadmium and AMD was stronger in whites than in blacks.

54 ENVIRONMENTAL SCIENCES↗

Exposure to polychlorinated biphenyls and the thyroid gland – examining and discussing possible longitudinal health effects in humans

Background: Many previous studies have dealt with the effect of polychlorinated biphenyls (PCBs) on the thyroid gland, but their findings are inconsistent. One problem of these studies has been their use of cross-sectional designs. Objectives: The aim of the current study is to investigate longitudinal effects of PCBs on the thyroid gland, focusing on: morphological changes in thyroid tissue (i.e. thyroid volume), changes in thyroid hormones and in thyroid antibodies. Methods: A total of 122 individuals (M{sub age}=44.7) were examined over a period of four years (t{sup 1} until t{sup 4}). Medical history was collected via interviews, an ultrasound examination was performed and blood samples were taken to determine plasma PCB levels, thyroid stimulating hormone (TSH), free triiodthyronine (fT3), free thyroxine (fT4), thyroid peroxidase antibodies (TPOab), thyreoglobulin antibodies (TGab) and thyroid-stimulating hormone receptor antibodies (TSHRab). Rank correlation coefficients and mixed effect models were performed controlling for age and total lipids. Results: There were negative correlations between higher chlorinated biphenyls and fT3, cross-sectionally as well as longitudinally. We also found an interaction effect of higher-chlorinated PCBs over time for fT4 as well as TSHRab. In case of high exposure, a decrease in fT4 and an increase in TSHRab level were found over time. In regards to the other variables, our findings yielded no clear results in the examined time period. Conclusion: This is the first study to shows a PCB-related effect on fT3, fT4 and TSHRab over a four year period. The data also suggest that morphological and antibody findings remain inconsistent and do not allow for unambiguous interpretation. - Highlights: • This is a longitudinal study which includes data from four cross sections. • Higher-chlorinated biphenyls are negatively correlated with fT3. • There are interactions of time and higher-chlorinated biphenyls to TSHRab and fT4. • There is an interaction of time and dioxin-like polychlorinated biphenyls to fT4. • No consistent effects were found for thyroid volume, TSH, TPOab and TGab.

54 ENVIRONMENTAL SCIENCES↗

Examining Margin Reduction and Its Impact on Dose Distribution for Prostate Cancer Patients Undergoing Daily Cone-Beam Computed Tomography

Purpose: To examine the dosimetric impact of margin reduction and quantify residual error after three-dimensional (3D) image registration using daily cone-beam computed tomography (CBCT) for prostate cancer patients. Methods and Materials: One hundred forty CBCTs from 5 prostate cancer patients were examined. Two intensity-modulated radiotherapy plans were generated on CT simulation on the basis of two planning target volume (PTV) margins: 10 mm all around the prostate and seminal vesicles except 6 mm posteriorly (10/6) and 5 mm all around except 3 mm posteriorly (5/3). Daily CBCT using the Varian On-Board Imaging System was acquired. The 10/6 and 5/3 simulation plans were overlaid onto each CBCT, and each CBCT plan was calculated. To examine residual error, PlanCT/CBCT intensity-based 3D image registration was performed for prostate localization using center of mass and maximal border displacement. Results: Prostate coverage was within 2% between the 10/6 and 5/3 plans. Seminal vesicle coverage was reduced with the 5/3 plan compared with the 10/6 plan, with coverage difference within 7%. The 5/3 plan allowed 30-50% sparing of bladder and rectal high-dose regions. For residual error quantification, center of mass data show that 99%, 93%, and 96% of observations fall within 3 mm in the left-right, anterior-posterior, and superior-inferior directions, respectively. Maximal border displacement observations range from 79% to 99%, within 5 mm for all directions. Conclusion: Cone-beam CT dosimetrically validated a 10/6 margin when soft-tissue localization is not used. Intensity-based 3D image registration has the potential to improve target localization and to provide guidelines for margin definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scanning electron microscopy examination of a Fast Flux Test Facility irradiated U-10Zr fuel cross section clad with HT-9

Observations from a scanning electron microscopy examination of irradiated U-10Zr fuel are presented. The sample studied had a local burnup of 5.7 atom percent and a local inner cladding temperature of 615°C. This examination by electron microscopy has concentrated on producing data relevant to facilitating a better understanding of Zr redistribution in irradiated U-10Zr fuel and on a better understanding of the complex microstructure present in fuel cladding chemical interaction (FCCI) layers. The presented zirconium redistribution data supplements the existing literature by providing a data set at these particular local conditions. In addition to FCCI layers that are readily visible in optical microscopy, this examination has revealed lanthanide degradation of the cladding by what appears to be a grain boundary facilitated pathway. Precipitates of fission produced Pd-lanthanide compounds were observed in the fuel. Furthermore, precipitated regions with elevated Mo and elevated W content were also observed in the HT-9 cladding of this sample.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An integrated approach to examine fuel-cladding chemical interaction in HT9/U-10Zr metallic fast reactor fuels: Coupling machine learning with electron microscopy and local mechanical properties analysis

The metallic U-Zr nuclear fuel alloy has garnered renewed interest as a promising candidate for next-generation sodium-cooled fast reactors. Recent studies and technology assessments have identified several areas requiring improvements, enhanced knowledge, and reliable data to strengthen the U-Zr fuel design basis for qualification and commercial applications. One of the most challenging phenomena impacting this fuel system’s performance is fuel-cladding chemical interaction (FCCI). This work aimed to harvest FCCI data by examining selected HT9/U-10Zr (wt. %) fuel samples of prototypic full-length fuel pins through an integrated approach. This approach integrated scanning electron microscopy (SEM) microstructure characterization with localized mechanical properties examination to deepen understanding of FCCI phenomenon in HT9/U-10Zr fuel system. Particularly, this study focused on MFF fuel pins irradiated at Fast Flux Test Facility (FFTF), which aimed to qualify metallic fuel as a driver fuel for FFTF and to assess its viability for larger-scale fast reactors. Electron microscopy provided high confidence in detecting and distinguishing the different FCCI layers, while small-scale mechanical testing (SSMT) probed the mechanical properties of these layers. SEM examination of a MFF-2 pin 192167, with a time averaged inner cladding temperature (TICT) slightly over 500°C, revealed minimal cladding-side FCCI (cladding wastage). In contrast, significantly thicker cladding wastage comprising two distinct sublayers was observed in samples from the thermally hot MFF-3 pin 193045 and MFF-5 pin 195011 where the TICT ranged from 610-635°C. SSMT indicated complete embrittlement in the sublayer adjacent to the fuel and a tendency toward embrittlement in the other sublayer. Additionally, a new machine learning method was developed, validated, and used to quantify cladding wastage thickness. The machine learning method reliably predicted the wastage thickness across various fuel pins and sample cross-sections. Furthermore, the available cladding wastage data from HT9/U-10Zr fuel system demonstrated a strong temperature dependency. However, the dataset remains small, and ongoing research activities are essential to further understand the FCCI phenomenon and develop a reliable FCCI model for enhanced fuel performance simulation under various conditions.

36 - MATERIALS SCIENCE↗

Application of petrographic examination techniques to the assessment of fire-damaged concrete and masonry structures

The number of building fires has doubled over the last 50 years. There has never been a greater need for structures to be assessed for fire damage to ensure safety and enable appropriate repairs to be planned. Fortunately, even after a severe fire, concrete and masonry structures are generally capable of being repaired rather than demolished. By allowing direct examination of microcracking and mineralogical changes, petrographic examination has become widely used to determine the depth of fire damage for reinforced concrete elements. Petrographic examination can also be applied to fire-damaged masonry structures built of materials such as stone, brick and mortar. Petrography can ensure accurate detection of damaged geomaterials, which provides cost savings during building repair and increased safety reassurance. This paper comprises a review of the role of petrography in fire damage assessments, drawing on a range of actual fire damage investigations.

36 MATERIALS SCIENCE↗

A comprehensive examination of the optical morphologies of 719 isolated galaxies in the AMIGA sample

Abstract Using images from Sloan Digital Sky Survey Data Release 8, we have re-examined the morphology of 719 galaxies from the Analysis of the interstellar Medium in Isolated GAlaxies (AMIGA) project, a sample consisting of the most isolated galaxies that have yet been identified. The goal is to further improve the classifications of these galaxies by examining them in the context of the Comprehensive de Vaucouleurs revised Hubble-Sandage (CVRHS) system, which includes recognition of features that go beyond the original de Vaucouleurs point of view. Our results confirm previous findings that isolated galaxies are found across the complete revised Hubble sequence, with intermediate- to late-type (Sb-Sc) spirals being relatively more common. Elmegreen Arm Classifications are also presented, and show that more than 50 per cent of the 514 spirals in the sample for which an arm class (AC) could be judged are grand design (AC 8,9,12). The visual bar fraction for the sample is ≈50 per cent, but only 16 per cent are classified as strongly barred (SB). The dominant family classification is SA (non-barred), the dominant inner variety classification is (s) (pure spiral), and the dominant outer variety classification is no outer ring, pseudo-ring, or lens. The Kolmogorov–Smirnov test is used to check for potential biases in the morphological interpretations, and for any possible relation between rings, bars, and ACs with local environment and far-infrared excess. The connection between morphology and stellar mass is also examined for a subset of the sample.

Buta, Ronald J.↗

A method of estimating conceptus doses resulting from multidetector CT examinations during all stages of gestation

Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low-dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulating women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals. Results: The results consist of Monte Carlo-generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free-in-air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations. Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made using the method developed in the current study.

61 RADIATION PROTECTION AND DOSIMETRY↗

Organ doses, effective doses, and risk indices in adult CT: Comparison of four types of reference phantoms across different examination protocols

Purpose: Radiation exposure from computed tomography (CT) to the public has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. Currently, various computational anthropomorphic phantoms are used to assess radiation dose by different research groups. It is desirable to better understand how the dose results are affected by different choices of phantoms. In this study, the authors assessed the uncertainties in CT dose and risk estimation associated with different types of computational phantoms for a selected group of representative CT protocols. Methods: Routinely used CT examinations were categorized into ten body and three neurological examination categories. Organ doses, effective doses, risk indices, and conversion coefficients to effective dose and risk index (k and q factors, respectively) were estimated for these examinations for a clinical CT system (LightSpeed VCT, GE Healthcare). Four methods were used, each employing a different type of reference phantoms. The first and second methods employed a Monte Carlo program previously developed and validated in our laboratory. In the first method, the reference male and female extended cardiac-torso (XCAT) phantoms were used, which were initially created from the Visible Human data and later adjusted to match organ masses defined in ICRP publication 89. In the second method, the reference male and female phantoms described in ICRP publication 110 were used, which were initially developed from tomographic data of two patients and later modified to match ICRP 89 organ masses. The third method employed a commercial dosimetry spreadsheet (ImPACT group, London, England) with its own hermaphrodite stylized phantom. In the fourth method, another widely used dosimetry spreadsheet (CT-Expo, Medizinische Hochschule, Hannover, Germany) was employed together with its associated male and female stylized phantoms. Results: For fully irradiated organs, average coefficients of variation (COV) ranged from 0.07 to 0.22 across the four male phantoms and from 0.06 to 0.18 across the four female phantoms; for partially irradiated organs, average COV ranged from 0.13 to 0.30 across the four male phantoms and from 0.15 to 0.30 across the four female phantoms. Doses to the testes, breasts, and esophagus showed large variations between phantoms. COV for gender-averaged effective dose and k factor ranged from 0.03 to 0.23 and from 0.06 to 0.30, respectively. COV for male risk index and q factor ranged from 0.06 to 0.30 and from 0.05 to 0.36, respectively; COV for female risk index and q factor ranged from 0.06 to 0.49 and from 0.07 to 0.54, respectively. Conclusions: Despite closely matched organ mass, total body weight, and height, large differences in organ dose exist due to variation in organ location, spatial distribution, and dose approximation method. Dose differences for fully irradiated radiosensitive organs were much smaller than those for partially irradiated organs. Weighted dosimetry quantities including effective dose, male risk indices, k factors, and male q factors agreed well across phantoms. The female risk indices and q factors varied considerably across phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Occupational and patient exposure as well as image quality for full spine examinations with the EOS imaging system

Purpose: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. Methods: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectors and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). Results: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. Conclusions: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-104: An Examination of Dose in the Buildup and Build-Down Regions

Purpose: To examine dose in the buildup and build-down regions and compare measurements made with various models and dosimeters Methods: Dose was examined in a 30×30cm {sup 2} phantom of water-equivalent plastic with 10cm of backscatter for various field sizes. Examination was performed with radiochromic film and optically-stimulated-luminescent-dosimeter (OSLD) chips, and compared against a plane-parallel chamber with a correction factor applied to approximate the response of an extrapolation chamber. For the build-down region, a correction factor to account for table absorption and chamber orientation in the posterior-anterior direction was applied. The measurement depths used for the film were halfway through their sensitive volumes, and a polynomial best fit curve was used to determine the dose to their surfaces. This chamber was also compared with the dose expected in a clinical kernel-based computer model, and a clinical Boltzmann-transport-equation-based (BTE) computer model. The two models were also compared against each other for cases with air gaps in the buildup region. Results: Within 3mm, all dosimeters and models agreed with the chamber within 10% for all field sizes. At the entrance surface, film differed in comparison with the chamber from +90% to +15%, the BTE-model by +140 to +3%, and the kernel-based model by +20% to −25%, decreasing with increasing field size. At the exit surface, film differed in comparison with the chamber from −10% to −15%, the BTE-model by −53% to −50%, the kernel-based model by −55% to −57%, mostly independent of field size. Conclusion: The largest differences compared with the chamber were found at the surface for all field sizes. Differences decreased with increasing field size and increasing depth in phantom. Air gaps in the buildup region cause dose buildup to occur again post-gap, but the effect decreases with increasing phantom thickness prior to the gap.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-04: Patient Eye-Lens Dose Reduction in Routine Brain CT Examinations Using Organ-Based Tube Current Modulation and In-Plane Bismuth Shielding

Purpose: The purpose of this study is to assess eye-lens dose for patients who underwent brain CT examinations using two dose reduction Methods: organ-based tube current modulation (OBTCM) and in-plane bismuth shielding method. Methods: This study received institutional review board approval; written informed consent to participate was obtained from all patients. Ninety patients who underwent the routine brain CT examination were randomly assigned to three groups, ie. routine, OBTCM, and bismuth shield. The OBTCM technique reduced the tube current when the X-ray tube rotates in front of patients’ eye-lens region. The patients in the bismuth shield group were covered one-ply bismuth shield in the eyes’ region. Eye-lens doses were measured using TLD-100H chips and the total effective doses were calculated using CT-Expo according to the CT scanning parameters. The surface doses for patients at off-center positions were assessed to evaluate the off-centering effect. Results: Phantom measurements indicates that OBTCM technique could reduced by 26% to 28% of the surface dose to the eye lens, and increased by 25% of the surface dose at the opposed incident direction at the angle of 180°. Patients’ eye-lens doses were reduced 16.9% and 30.5% dose of bismuth shield scan and OBTCM scan, respectively compared to the routine scan. The eye-lens doses were apparently increased when the table position was lower than isocenter. Conclusion: Reducing the dose to the radiosensitive organs, such as eye lens, during routine brain CT examinations could lower the radiation risks. The OBTCM technique and in-plane bismuth shielding could be used to reduce the eye-lens dose. The eye-lens dose could be effectively reduced using OBTCM scan without interfering the diagnostic image quality. Patient position relative the CT gantry also affects the dose level of the eye lens. This study was supported by the grants from the Ministry of Science and Technology of Taiwan (MOST103-2314-B-182-009-MY2), and Chang Gung Memorial Hospital (CMRPD1C0682)

60 APPLIED LIFE SCIENCES↗

SU-F-P-45: Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms

Purpose: Iterative reconstruction (IR) algorithms have been adopted by medical centers in the past several years. IR has a potential to substantially reduce patient dose while maintaining or improving image quality. This study characterizes dose reductions in clinical settings for CT examinations using IR. Methods: We retrospectively analyzed dose information from patients who underwent abdomen/pelvis CT examinations with and without contrast media in multiple locations of our Healthcare system. A total of 743 patients scanned with ASIR on 64 slice GE lightspeed VCTs at three sites, and 30 patients scanned with SAFIRE on a Siemens 128 slice Definition Flash in one site was retrieved. For comparison, patient data (n=291) from a GE scanner and patient data (n=61) from two Siemens scanners where filtered back-projection (FBP) was used was collected retrospectively. 30% and 10% ASIR, and SAFIRE Level 2 was used. CTDIvol, Dose-length-product (DLP), weight and height from all patients was recorded. Body mass index (BMI) was calculated accordingly. To convert CTDIvol to SSDE, AP and lateral dimensions at the mid-liver level was measured for each patient. Results: Compared with FBP, 30% ASIR reduces dose by 44.1% (SSDE: 12.19mGy vs. 21.83mGy), while 10% ASIR reduced dose by 20.6% (SSDE 17.32mGy vs. 21.83). Use of SAFIRE reduced dose by 61.4% (SSDE: 8.77mGy vs. 22.7mGy). The geometric mean for patients scanned with ASIR was larger than for patients scanned with FBP (geometric mean is 297.48 mmm vs. 284.76 mm). The same trend was observed for the Siemens scanner where SAFIRE was used (geometric mean: 316 mm with SAFIRE vs. 239 mm with FBP). Patient size differences suggest that further dose reduction is possible. Conclusion: Our data confirmed that in clinical practice IR can significantly reduce dose to patients who undergo CT examinations, while meeting diagnostic requirements for image quality.

60 APPLIED LIFE SCIENCES↗