Search NASA⌕ Search

SEARCH · Search NASA

Results for “Extraterrestrial Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Electron Spin Resonance (ESR) studies of returned comet nucleus samples

The most important objective of the Comet Nucleus Sample Returm Mission is to return samples which could reflect formation conditions and evolutionary processes in the early solar nebula. It is expected that the returned samples will consist of fine-grained silicate materials mixed with ices composed of simple molecules such as H2O, NH3, CH4 as well as organics and/or more complex compounds. Because of the exposure to ionizing radiation from cosmic-ray, gamma-ray, and solar wind protons at low temperature, free radicals are expected to be formed and trapped in the solid ice matrices. The kind of trapped radical species together with their concentration and thermal stability can be used as a dosimeter as well as a geothermometer to determine thermal and radiation histories as well as outgassing and other possible alternation effects since the nucleus material was formed. Since free radicals that are known to contain unpaired electrons are all paramagnetic in nature, they can be readily detected and characterized in their native form by the Electron Spin Resonance (ESR) method. In fact, ESR has been shown to be a non-destructive, highly sensitive tool for the detection and characterization of paramagnetic, ferromagnetic, and radiation damage centers in terrestrial and extraterrestrial geological samples. The potential use of ESR as an effective method in the study of returned comet nucleus samples, in particular, in the analysis of fine-grained solid state icy samples is discussed.

Tsay, Fun-Dow↗

Water in Lunar Materials

Two lines of evidence, suggest independently that materials which formed the Moon were not anhydrous: 1. Meteorites, our only sample of extraterrestrial material, contain water in varying amounts. Chondrites average about 0.25% water by weight. Carbonaceous chondrites, however, contain up to 20% water; and, although much of this water may be adsorbed atmospheric and surface water, the abundance of silicate hydrates in these objects indicates that considerable water existed in these meteorites before Earth impact. 2. The gas emission from Alphonsus observed by Kosyrev indicates that volatiles are diffusing out of the Moon. The observed emission was a C, band. Analyses of presumably juvenile gases reaching the Earth's surface show that water generally composes 95% or more of the gas. By analogy, it is suggested that water must be reaching the lunar surface. Consequently, it is reasonable to conclude that water existed in the materials which formed the Moon as well as those which formed the Earth or meteorites (or their source object). An estimate of the water content of the primordial Earth is 0.03%.

Speed, R. C.↗

Cosmic dust and space debris; Proceedings of the Topical Meetings and Workshop 6 of the 26th COSPAR Plenary Meeting, Toulouse, France, June 30-July 11, 1986

These proceedings encompass topics in the fields of extraterrestrial material samples, IRAS solar system and dust model results, and earth orbit debris. Attention is given to chemical fractionation during high velocity impact, particle deceleration and survival in multiple thin foil targets, and IRAS studies of asteroids, comets, cometary tails, the zodiacal background, and the three-dimensional modeling of interplanetary dust. Also discussed are the evolution of an earth orbit debris cloud, orbital debris due to future space activities, collision probabilities in geosynchronous orbits, and a bitelescopic survey of low altitude orbital debris.

Mcdonnell, J. A. M.↗

Miniature Instrumentation for SIPR (Subsurface Ice PRobe)

Ice coring has proved to be a valuable scientific tool for determining climate history on Earth. The goal of the SIPR project is to develop a simple extraterrestrial ice sampling method of comparable value to coring. The SIPR probe works by melting its way through glacial ice, pumping the melt water to the surface for analysis as it descends hundreds of meters. The specific geometry of the probe, along with size and power constraints, requires creative diagnostic instrumentation. A thin, vertically strung heated filament will provide continuous-level monitoring of water in down-hole containers. The filament has an appreciable temperature coefficient to resistance (TCR), so as water cools the wire, its resistance decreases. At a constant electrical current, the voltage across the filament varies linearly with water level.

Ostmo, Karl P.↗

Silica Aerogel Captures Cosmic Dust Intact

The mesostructure of silica aerogel resembles stings of grapes, ranging in size from 10 to 100 angstrom. This fine mesostructure transmits nearly 90 percent of incident light in the visible, while providing sufficiently gentle dissipation of the kinetric energy of hypervelocity cosmic dust particles to permit their intact capture. We introduced silica aerogel in 1987 as capture medium to take advantage of its low density, fine mesostruicture and most importantly, its transparency, allowing optical location of captured micron sized particles.

aerogel comets cosmic dust extraterrestrial sample↗

The Chemical Evolution of Cosmic Carbon: Laboratory Studies with the COSmIC Facility

Cosmic dust plays an essential role in our understanding of the chemical and physical evolution of the universe. Our understanding of cosmic dust relies on a combination of astronomical observations (either remote or on extraterrestrial dust samples), astrophysical modeling and laboratory studies of realistic analogs of cosmic dust grains. The COSmIC facility was developed at NASA Ames to study the evolution of cosmic carbon from circumstellar outflows to interstellar clouds to planetary atmospheres in the laboratory [1]. COSmIC stands for “Cosmic Simulation Chamber” and is dedicated to the study of neutral and ionized molecules and grain particles under the low temperature and density conditions that are required to simulate space environments. COSmIC integrates a variety of instruments that allow generating, processing, and monitoring simulated space conditions in the laboratory. It is composed of a Pulsed Discharge Nozzle (PDN) expansion that generates a plasma in a free supersonic jet expansion, coupled to high-sensitivity, complementary in situ diagnostic tools used for the detection and characterization of the species present in the expansion: Cavity Ring Down Spectroscopy (CRDS) and fluorescence spectroscopy systems for photonic detection and an orthogonal Reflectron Time-Of-Flight Mass Spectrometer (oReTOF-MS) for mass detection. Recent advances achieved in laboratory astrophysics using COSmIC’s laboratory data in synergy with observational data will be presented. These results include the formation of dust grains and aerosols from gas-phase molecular precursors in environments as varied as circumstellar outflows of late AGB stars [2] and planetary atmospheres [3] and the evolution of our understanding of the diffuse interstellar bands (DIBs) with applications to the ESO Diffuse Interstellar Bands Large Exploration Survey (EDIBLES [4, 5]). Plans for future laboratory developments and techniques to study the evolution of cosmic carbon molecules and grains (including NIR-MIR CRDS, laser induced fluorescence (LIF) and incandescence (LII)) will also be addressed as well as their astronomical applications.

Salama, F.↗

Space Weathering of Genesis Mission Solar-wind Collectors with Inferences for Weathering on Airless Bodies

Samples from the Genesis Solar Wind Sample Return (NASA Discovery 5) are a unique opportunity to study the initial stages of space weathering, i.e., the physical and chemical effects of solar-wind irradiation. Arrays of collectors containing multiple materials were each exposed to a different solar-wind regime (fast, slow, bulk, or coronal mass ejection) at the L1 point for long durations (years). Materials exposed to the solar wind included metals, semiconductors, and insulators. Although the time of exposure was obviously short relative to samples having extraterrestrial origins, optical properties, surface chemical properties, and matrix structure have changed in many collectors due to exposure to solar wind. The thickness of amorphous zones, where present, appears to correspond with the depth of the peak of the solar-wind H distribution in each regime. Damage from high-energy particles was negligible because the collectors were 700 μm or less in thickness and shielded from the back by the spacecraft. Micrometeorite impacts and sputtering were also negligible because of the short exposure times. Our current results are preliminary: We hope future workers will extend this study both to support Genesis characterization efforts and to further understand space-weathering processes on a geologic timescale.

space weathering↗

An Integrated Tool for System Analysis of Sample Return Vehicles

The next important step in space exploration is the return of sample materials from extraterrestrial locations to Earth for analysis. Most mission concepts that return sample material to Earth share one common element: an Earth entry vehicle. The analysis and design of entry vehicles is multidisciplinary in nature, requiring the application of mass sizing, flight mechanics, aerodynamics, aerothermodynamics, thermal analysis, structural analysis, and impact analysis tools. Integration of a multidisciplinary problem is a challenging task; the execution process and data transfer among disciplines should be automated and consistent. This paper describes an integrated analysis tool for the design and sizing of an Earth entry vehicle. The current tool includes the following disciplines: mass sizing, flight mechanics, aerodynamics, aerothermodynamics, and impact analysis tools. Python and Java languages are used for integration. Results are presented and compared with the results from previous studies.

Samareh, Jamshid A.↗

Enantioselective Three-Dimensional High-Performance Liquid Chromatographic Determination of Amino Acids in the Hayabusa2 Returned Samples from the Asteroid Ryugu

The chirality of amino acids in extraterrestrial materials may provide an insight into the origin of the essential L-enantiopure amino acids in the terrestrial biosphere. In 2020, the Hayabusa2 mission succeeded in bringing back surface materials from the C-type asteroid (162173) Ryugu to the Earth. Amino acids were one of the targeted organic molecules to be studied in the Ryugu samples. To analyze the various structural isomers of amino acids, which were expected to be present, from the limited amount of the returned samples, the development of a highly-sensitive and selective analytical method was necessary. In the present study, a three-dimensional high-performance liquid chromatography (3D-HPLC) system has been developed for the enantioselective determination of five proteinogenic and three non-proteinogenic amino acids in the Ryugu samples, in which amino acids in the sample were separated by reversed-phase, anion-exchange and enantioselective columns after the fluorescence derivatization with 4-fluoro-7-nitro-2,1,3-benzoxadiozole. The applicability of the analytical system to the extraterrestrial samples was evaluated by analyzing several types of carbonaceous meteorites before applying the system to the Ryugu samples. In the analysis of the Ryugu samples, all of the target amino acids were successfully determined quantitatively. Non-proteinogenic amino acids including 2-amino-n-butyric acid, isovaline and norvaline, rarely present in the terrestrial environment, were found as almost racemic mixtures with 47.1 to 55.2%L.

Amino acids↗

Fossil Signatures Using Elemental Abundance Distributions and Bayesian Probabilistic Classification

Elemental abundances (C6, N7, O8, Na11, Mg12, Al3, P15, S16, Cl17, K19, Ca20, Ti22, Mn25, Fe26, and Ni28) were obtained for a set of terrestrial fossils and the rock matrix surrounding them. Principal Component Analysis extracted five factors accounting for the 92.5% of the data variance, i.e. information content, of the elemental abundance data. Hierarchical Cluster Analysis provided unsupervised sample classification distinguishing fossil from matrix samples on the basis of either raw abundances or PCA input that agreed strongly with visual classification. A stochastic, non-linear Artificial Neural Network produced a Bayesian probability of correct sample classification. The results provide a quantitative probabilistic methodology for discriminating terrestrial fossils from the surrounding rock matrix using chemical information. To demonstrate the applicability of these techniques to the assessment of meteoritic samples or in situ extraterrestrial exploration, we present preliminary data on samples of the Orgueil meteorite. In both systems an elemental signature produces target classification decisions remarkably consistent with morphological classification by a human expert using only structural (visual) information. We discuss the possibility of implementing a complexity analysis metric capable of automating certain image analysis and pattern recognition abilities of the human eye using low magnification optical microscopy images and discuss the extension of this technique across multiple scales.

Hoover, Richard B.↗

Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip

There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given in the Science Instruments.

Mora, Maria F.↗

Mars Sample Return: Considerations for the Curation of Astromaterials from a Restricted Planet

The joint NASA/ESA Mars Sample Return (MSR) campaign is underway. The Perseverance Rover has already collected a returnable sample suite currently cached at Three Forks and the pairs to these samples are stored on the Rover with more compelling samples planned to be collected. The MSR collection would represent the most geologically diverse astromaterial collection ever returned and should provide information on topics ranging from Martian geological and biological history to Martian environmental hazards and in situ resource utilization to support potential human exploration. Although Jezero Crater and the surrounding area are not Mars special regions, the scientific opinion is that Mars as a whole is of significant interest to the process of chemical evolution and/or the origin of life. Therefore, due to possibility, however remote, that the samples could contain extraterrestrial life, MSR is classified as a Category V: Restricted Earth Return mission by the NASA Planetary Protection Office. As a result of this classification, a MSR Sample Receiving Facility (SRF) must not only provide a pristine environment to ensure samples are protected from terrestrial contamination for scientific investigations, but it must also provide high-containment to isolate the samples from Earth’s biosphere until the samples are deemed safe for release and/or sterilized.

Mars Sample Return↗

The Venus Atmospheric Sample Return (VATMOS-SR) Mission Concept

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small space- craft mission concept that would return several gas samples from the upper atmosphere of Venus (< 110 km) to Earth for scientific analysis. This could be the first sample return mission for an extraterrestrial atmosphere and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and ac- quire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen (e.g. trajectory shown in Fig. 1).

direct simulation Monte Carlo↗