Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLAG”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A High Resolution Simulation of a Single Shock-Accelerated Particle

We report particle drag models, which capture macroviscous and pressure effects, have been developed over the years for various flow regimes to enable cost effective simulations of particle-laden flows. The relatively recent derivation by Maxey and Riley has provided an exact equation of motion for spherical particles in a flow field based on the continuum assumption. Many models that have been simplified from these equations have provided reasonable approximations; however, the sensitivity of particle-laden flows to particle drag requires a very accurate model to simulate. To develop such a model, a two-dimensional axisymmetric Navier–Stokes direct numerical simulation of a single particle in a transient, shock-driven flow field was conducted using the hydrocode FLAG. FLAGs capability to run arbitrary Lagrangian-Eulerian hydrodynamics coupled with solid mechanic models makes it an ideal code to capture the physics of the flow field around and in the particle as it is shock-accelerated—a challenging regime to study. The goal of this work is twofold: to provide a validation for FLAGs Navier–Stokes and heat diffusion solutions and to provide a rationale for recent experimental particle drag measurements.

42 ENGINEERING↗

Patient geometry-driven information retrieval for IMRT treatment plan quality control

Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D{sub 50} (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as controls. Replanning with an effort to reduce D{sub 50} was conducted on these 26 parotids. After replanning, the average reductions for D{sub 50} of the 17 flagged parotids and nine unflagged parotids were 6.6 and 1.9 Gy, respectively. These results demonstrate that the quality control method has accurately identified not only the parotids that require dose reductions but also those for which dose reductions are marginal. Originally, 11 of out the 17 flagged parotids did not meet the Radiation Therapy Oncology Group sparing goal of V(30 Gy)<50%. Replanning reduced them to three. Additionally, PTV coverage and OAR sparing of the original plans were compared to those of the replans by using pairwise Wilcoxon p test. The statistical comparisons show that replanning compromised neither PTV coverage nor OAR sparing. Conclusions: This method provides an effective quality control mechanism for evaluating the DVHs of the OARs. Adoption of such a method will advance the quality of current IMRT planning, providing better treatment plan consistency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance and Quality Control (QA/QC) of Meteorological Time Series Data for Billy Barr, East River, Colorado USA

A comprehensive Quality Assurance (QA) and Quality Control (QC) statistical framework consists of three major phases: Phase 1—Preliminary raw data sets exploration, including time formatting and combining datasets of different lengths and different time intervals; Phase 2—QA of the datasets, including detecting and flagging of duplicates, outliers, and extreme values; and Phase 3—the development of time series of a desired frequency, imputation of missing values, visualization and a final statistical summary. The time series data collected at the Billy Barr meteorological station (East River Watershed, Colorado) were analyzed. The developed statistical framework is suitable for both real-time and post-data-collection QA/QC analysis of meteorological datasets.The files that are in this data package include one excel file, converted to CSV format (Billy_Barr_raw_qaqc.csv) that contains the raw meteorological data, i.e., input data used for the QA/QC analysis. The second CSV file (Billy_Barr_1hr.csv) is the QA/QC and flagged meteorological data, i.e., output data from the QA/QC analysis. The last file (QAQC_Billy_Barr_2021-03-22.R) is a script written in R that implements the QA/QC and flagging process. The purpose of the CSV data files included in this package is to provide input and output files implemented in the R script.

54 ENVIRONMENTAL SCIENCES↗

A Numerical Simulation of a Single Shock-Accelerated Particle

Particle drag models, which capture macro viscous and pressure effects, have been developed over the years for various flow regimes to enable cost effective simulations of particle-laden flows. The relatively recent derivation by Maxey and Riley has provided an exact equation of motion for spherical particles in a flow field based on the continuum assumption. Many models that have been simplified from these equations have provided reasonable approximations; however, the sensitivity of particle-laden flows to particle drag requires a very accurate model to simulate. To develop such a model, a 2D axisymmetric Navier-Stokes direct numerical simulation of a single particle in a transient, shock-driven flow field was conducted in the hydrocode FLAG. FLAG’s capability to run arbitrary Lagrangian-Eulerian hydrodynamics coupled with solid mechanic models makes it an ideal code to capture the physics of the flow field around and in the particle as it is shock-accelerated – a challenging regime to study. The goal of this work is twofold: to provide a validation for FLAG’s Navier-Stokes and heat diffusion solutions, and to provide a rationale for recent experimental particle drag measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lightning arrestor connector lead magnesium niobate qualification pellet test procedures.

Enhanced knowledge preservation for DOE DP technical component activities has recently received much attention. As part of this recent knowledge preservation effort, improved documentation of the sample preparation and electrical testing procedures for lead magnesium niobate--lead titanate (PMN/PT) qualification pellets was completed. The qualification pellets are fabricated from the same parent powders used to produce PMN/PT lightning arrestor connector (LAC) granules at HWF&T. In our report, the procedures for fired pellet surface preparation, electrode deposition, electrical testing and data recording are described. The dielectric measurements described in our report are an information only test. Technical reasons for selecting the electrode material, electrode size and geometry are presented. The electrical testing is based on measuring the dielectric constant and dissipation factor of the pellet during cooling from 280 C to 220 C. The most important data are the temperature for which the peak dielectric constant occurs (Curie Point temperature) and the peak dielectric constant magnitude. We determined that the peak dielectric constant for our procedure would be that measured at 1 kHz at the Curie Point. Both the peak dielectric constant and the Curie point parameters provide semi-quantitative information concerning the chemical and microstructural homogeneity of the parent material used for the production of PMN/PT granules for LACs. Finally, we have proposed flag limits for the dielectric data for the pellets. Specifically, if the temperature of the peak dielectric constant falls outside the range of 250 C {+-} 30 C we propose that a flag limit be imposed that will initiate communication between production agency and design agency personnel. If the peak dielectric constant measured falls outside the range 25,000 {+-} 10,000 we also propose that a flag limit be imposed.

36 MATERIALS SCIENCE↗

Populus_trichocarpa_Breeding_Population_SNPs

These data are from the manuscript “Application of Genomic Prediction in a Populus trichocarpa Breeding Program”, by Brian J. Stanton, David Macaya-Sanz, Chanaka Roshan Abeyratne, David Kainer, Kathy Haiby, Austin Himes, Carlos Gantz, Gerald A. Tuskan, and Stephen P. DiFazio. The data are based on genome resequencing to approximately 10X depth on two collections of Populus trichocarpa trees from Oregon, Washington, California, and British Columbia. The first collection consists of 293 genets collected by Poplar Innovations LLC for a breeding program. The second collection consists of 961 trees collected for the purpose of genome-wide association studies. These genets were sequenced using short, paired-end Illumina sequence reads (Chhetri et al. 2019). Reads were aligned to the P. trichocarpa ′Stettler-14′ reference (Hofmeister et al. 2020), with minor modifications to correct mis-assemblies (Zhou et al. 2020), and variants were called as per methods described in (Abeyratne et al. 2023). Identified variants were filtered using GATK’s VariantFiltration tool (DePristo et al. 2011), with filter expression flag set to “AF < 0.01 || AF > 0.99 || QD < 10.0 || ExcessHet > 20.0 || FS > 10.0 || MQ < 58.0”. SNPs with severe departures from Hardy−Weinberg expectations (exact-test p< 0.01) were also removed using vcftools --hwe flag (Danecek et al. 2011), resulting in 15,627,211 bi-allelic SNPs. The data included here consist of 141,903 high quality bi-allelic genome-wide SNPs obtained by further filtering the original SNP dataset using vcftools with flags --maf 0.05, --max-maf 0.95, --max-missing 0.95, --min-meanDP 10.75, --max-meanDP 43.00, --thin 2000. Collectively, these filtering parameters removed SNPs with 1) a minor allele frequency ≤ 0.05; 2) proportion of missing data for individual loci exceeding 5%; 3) sequencing depth more than 2X mean-depth or less than 0.5X mean-depth; or 4) a distance of

09 BIOMASS FUELS↗

Automated identification of local contamination in remote atmospheric composition time series

Abstract. Atmospheric observations in remote locations offer a possibility of exploring trace gas and particle concentrations in pristine environments. However, data from remote areas are often contaminated by pollution from local sources. Detecting this contamination is thus a central and frequently encountered issue. Consequently, many different methods exist today to identify local contamination in atmospheric composition measurement time series, but no single method has been widely accepted. In this study, we present a new method to identify primary pollution in remote atmospheric datasets, e.g., from ship campaigns or stations with a low background signal compared to the contaminated signal. The pollution detection algorithm (PDA) identifies and flags periods of polluted data in five steps. The first and most important step identifies polluted periods based on the derivative (time derivative) of a concentration over time. If this derivative exceeds a given threshold, data are flagged as polluted. Further pollution identification steps are a simple concentration threshold filter, a neighboring points filter (optional), a median, and a sparse data filter (optional). The PDA only relies on the target dataset itself and is independent of ancillary datasets such as meteorological variables. All parameters of each step are adjustable so that the PDA can be “tuned” to be more or less stringent (e.g., flag more or fewer data points as contaminated). The PDA was developed and tested with a particle number concentration dataset collected during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition in the central Arctic. Using strict settings, we identified 62 % of the data as influenced by local contamination. Using a second independent particle number concentration dataset also collected during MOSAiC, we evaluated the performance of the PDA against the same dataset cleaned by visual inspection. The two methods agreed in 94 % of the cases. Additionally, the PDA was successfully applied to a trace gas dataset (CO2), also collected during MOSAiC, and to another particle number concentration dataset, collected at the high-altitude background station Jungfraujoch, Switzerland. Thus, the PDA proves to be a useful and flexible tool to identify periods affected by local contamination in atmospheric composition datasets without the need for ancillary measurements. It is best applied to data representing primary pollution. The user-friendly and open-access code enables reproducible application to a wide suite of different datasets. It is available at https://doi.org/10.5281/zenodo.5761101 (Beck et al., 2021).

54 ENVIRONMENTAL SCIENCES↗

Assessment of BSRN radiation records for the computation of monthly means

The accuracy of the Baseline Surface Radiation Network (BSRN) radiation monthly averages are assessed by investigating data gap frequency due to missing or discarded high time resolution data. The monthly statistics, especially means are considered to be important and useful values for climate research, model performance evaluations and for assessing the quality of satellite computations. The study investigates the spread in different algorithms that have been applied for the computation of monthly means from minute values. We found that a substantial fraction of the radiation fluxes observed at BSRN sites is either missing or flagged as questionable. The percentage of missing data is 4.4%, 13.0%, and 6.5% for global radiation, direct shortwave radiation, and downwelling longwave radiation, respectively. Most flagged data in the shortwave are due to nighttime instrumental noise and can reasonably be set to zero after correcting for thermal offsets in the daytime data. The paper reveals that the computation of monthly means from 1-minute observations distinctly depends on the selected method. The intra-method difference generally increases with an increasing fraction of missing data. The study demonstrates that the handling of flagged data clearly impacts on monthly mean estimates obtained with different methods. We showed that the spread of monthly shortwave fluxes are generally clearly higher than for downwelling longwave radiation. Overall, BSRN observation provide sufficient accuracy and completeness for reliable estimates of monthly mean values. However, we should aim at further increasing the data quality by reducing the data gap frequency and the number of outliers. The authors suggest using a standardized method for the computation of monthly means in order to avoid a mismatch of published monthly mean radiation fluxes from BSRN.

54 ENVIRONMENTAL SCIENCES↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

TROPoe retrievals from SGP C1

The TROPoe (formerly called AERIoe) algorithm (Turner and L&ouml;hnert 2014, 2021; Turner and Blumberg 2019) retrieves profiles of temperature and water vapor mixing ratio, together with cloud properties for a single-layer cloud (i.e., LWP, effective radius), from AERI-observed infrared radiance spectrum. The data can be used to characterize the evolution of the planetary boundary layer and boundary layer clouds. This data set was collected at the ARM SGP Central Facility (CF) during and after the MicroPulse DIAL Demonstration (MPDDEMO) field campaign. The TROPoe retrieval was run at 5-minute resolution, but retrievals can be performed at the maximum temporal resolution of the AERI instrument (order 30 s) -- if this higher temporal resolution is desired, please contact Dave Turner. This is a physical-iterative retrieval method. The retrieval of thermodynamic profiles from spectral infrared radiance observations is an ill-posed problem, and thus constraints need to be included in the retrieval algorithm to provide physically plausible results. Here, we use a climatology of radiosonde profiles collected at the ARM SGP site during the summer as our prior information in an optimal estimation framework. Surface meteorology and output from the rapid-refresh (RAP) numerical weather prediction model (above 4 km) were used as additional constraints by the retrieval. As the method uses an optimal estimation framework, a full error covariance matrix of each solution is included in the output file. The 1-sigma uncertainty of each retrieved variable, which is derived from the error covariance matrix, is included for each scientific field and is named "sigma_X", where "X" is the name of the scientific field (e.g., 'temperature'). The information content in the AERI observations, which is in the "dfs" field, on the thermodynamic profiles is primarily concentrated in the lowest 3 km or up to cloud base; the retrieved data should not be used above that level (or used with caution). There is an overall "qc_flag" field that is set when a retrieval should not be trusted. However, the logic that sets this flag did not work correctly, and it should not be used. Instead, consider all retrievals that have a value for "converged_flag" greater than 0 as valid. If you have any questions, contact Dave Turner. This is Release_2_12 of the TROPoe algorithm.

54 ENVIRONMENTAL SCIENCES↗

Inexpensive programmable clock for a 12-bit computer

An inexpensive programmable clock was built for a digital PDP-12 computer. The instruction list includes skip on flag; clear the flag, clear the clock, and stop the clock; and preset the counter with the contents of the accumulator and start the clock. The clock counts at a rate determined by an external oscillator and causes an interrupt and sets a flag when a 12-bit overflow occurs. An overflow can occur after 1 to 4096 counts. The clock can be built for a total parts cost of less than $100 including power supply and I/O connector. Slight modification can be made to permit its use on larger machines (16 bit, 24 bit, etc.) and logic level shifting can be made to make it compatible with any computer.

Vrancik, J. E.↗

Memory-based parallel data output controller

A memory-based parallel data output controller employs associative memories and memory mapping to decommutate multiple channels of telemetry data. The output controller contains a random access memory (RAM) which has at least as many address locations as there are channels. A word counter addresses the RAM which provides as it outputs an encoded peripheral device number and a MSB/LSB-first flag. The encoded device number and a bit counter address a second RAM which contains START and STOP flags to pick out the required bits from the specified word number. The LSB/MSB, START and STOP flags, along with the serial input digital data go to a control block which selectively fills a shift register used to drive the parallel data output bus.

Stattel, R. J.↗

Southern Durchmusterung (Schoenfeld 1886): Documentation for the machine-readable version

The machine-readable version of the catalog, as it is currently being distributed from the Astronomical Data Center, is described. The Southern Durchmusterung (SD) was computerized at the Centre de Donnees Astronomiques de Strasbourg and at the Astronomical Data Center at the National Space Science Data Center, NASA/Goddard Space Flight Center. Corrigenda listed in the original SD volume and published by Kuenster and Sticker were incorporated into the machine file. In addition, one star indicated to be missing in a published list, and later verified, is flagged so that it can be omitted from computer plotted charts if desired. Stars deleted in the various errata lists were similarly flagged, while those with revised data are flagged and listed in a separate table. This catalog covers the zones -02 to -23 degrees; zones +89 to -01 degrees (the Bonner Durchmusterung) are included in a separate catalog available in machine-readable form.

Warren, Wayne H., Jr.↗

Bonner Durchmusterung (Argelander 1859-1862): Documentation for the machine-readable version

The machine-readable version of the catalog, as it is currently being distributed from the Astronomical Data Center, is described. The entire Bonner Durchmusterung (BD) was computerized through the collaborative efforts of the Centre de Donnees Astronomiques de Strasbourg, l'Observatoire de Nice, and the Astronomical Data Center at the NASA/Goddard Space Flight Center. All corrigenda published in the original BD volumes were incorporated into the machine file, along with changes published following the 1903 edition. In addition, stars indicated to be missing in published lists and verified by various techniques are flagged so that they can be omitted from computer plotted charts if desired. Stars deleted in the various errata lists were similarly flagged, while those with revised data are flagged and listed in a separate table.

Warren, Wayne H., Jr.↗

Telecommunications end-to-end systems monitoring on TOPEX/Poseidon: Tools and techniques

The TOPEX/Poseidon Project Satellite Performance Analysis Team's (SPAT) roles and responsibilities have grown to include functions that are typically performed by other teams on JPL Flight Projects. In particular, SPAT Telecommunication's role has expanded beyond the nominal function of monitoring, assessing, characterizing, and trending the spacecraft (S/C) RF/Telecom subsystem to one of End-to-End Information Systems (EEIS) monitoring. This has been accomplished by taking advantage of the spacecraft and ground data system structures and protocols. By processing both the received spacecraft telemetry minor frame ground generated CRC flags and NASCOM block poly error flags, bit error rates (BER) for each link segment can be determined. This provides the capability to characterize the separate link segments, determine science data recovery, and perform fault/anomaly detection and isolation. By monitoring and managing the links, TOPEX has successfully recovered approximately 99.9 percent of the science data with an integrity (BER) of better than 1 x 10(exp 8). This paper presents the algorithms used to process the above flags and the techniques used for EEIS monitoring.

Calanche, Bruno J.↗

Space Architecture: Building The Future

There's been a good deal of flag-waving over the last five years about technology-or rather, a certain terror of technology that underlies almost all recent talk of the global avant-garde. Don't be fooled: the cool, clinical praise of the cyborg and the virtual realm is no more than critical bravado. It's an existential machismo in the world of semiotics which forces the contemporary philosopher to ante up, to get theoretically comfortable with an anti-sensual world of possibilities to which we all respond-let's be frank-with profound discomfort. Does this flag-waving about media, Y2K, robotics and biotechnology serve to cover a pervasive, cross-cultural mesh of fear? Or are we waving our surrender to a process we ourselves have set in motion? Let's look at the medium of a flag-the image and its underlying message.

Adams, Constance↗

Atmospheric Boundary Layer Wind Data During the Period January 1, 1998 Through January 21, 1999 at the Dallas-Fort Worth Airport: Data and Processing - Volume 2

The NASA Langley Research Center's Aircraft Vortex Spacing System (AVOSS) requires accurate winds and turbulence to determine aircraft wake vortex behavior near the ground. Volume 1 described the wind input and quality analysis process. This volume documents the data available during the period January 1998 through January 1999 and the partitioning and concatenation of files for time of day, turbulence, non duplication, cross wind profile quality and ceiling and visibility. It provides the resultant filtered files for the first three partitions as well as identification of ceiling/visibility conditions when they were below 5000 feet and 5 miles respectively. It also includes the wind profile quality flags to permit automatic selection of files for AVOSS application using selected ceiling/visibility and wind profile quality values and flags (or no flags).

Zak, J. Allen↗

Photosynthetic capacity and dry mass partitioning in dwarf and semi-dwarf wheat (Triticum aestivum L.)

Efficient use of space and high yields are critical for long-term food production aboard the International Space Station. The selection of a full dwarf wheat (less than 30 cm tall) with high photosynthetic and yield potential is a necessary prerequisite for growing wheat in the controlled, volume-limited environments available aboard long-term spaceflight missions. This study evaluated the photosynthetic capacity and carbon partitioning of a full-dwarf wheat cultivar, Super Dwarf, which is routinely used in spaceflight studies aboard U.S. space shuttle and NASA/Mir missions and made comparisons with other dwarf and semi-dwarf wheat cultivars utilized in other ground-based studies in plant space biology. Photosynthetic capacity of the flag leaf in two dwarf (Super Dwarf, BB-19), and three semi-dwarf (Veery-10, Yecora Rojo, IBWSN 199) wheat cultivars (Triticum aestivum L.) was assessed by measuring: net maximum photosynthetic rate, RuBP carboxylation efficiency, chlorophyll concentration and flag leaf area. Dry mass partitioning of carbohydrates to the leaves, sheaths, stems and ear was also assessed. Plants were grown under controlled environmental conditions in three replicate studies: slightly enriched CO2 (370 micromoles mol-1), high photosynthetic photon flux (1000 micromoles m-2 s-1; 58 mol m-2 d-1) for a 16 h photoperiod, 22/15 degrees C day/night temperatures, ample nutrients and water provided by one-half strength Hoagland's nutrient solution (Hoagland and Arnon, 1950). Photosynthetic capacity of the flag leaf was determined at anthesis using net CO2 exchange rate versus internal CO2 concentration curves measured under saturating light (2000 micromoles m-2 s-1) and CO2 (1000 micromoles mol-1). Dwarf wheat cultivars had greater photosynthetic capacities than the taller semi-dwarfs, they averaged 20% higher maximum net photosynthetic rates compared to the taller semi-dwarfs, but these higher rates occurred only at anthesis, had slightly greater carboxylation efficiencies and significantly increased chlorophyll concentrations per unit leaf area. The reduced-height wheat had significantly less dry mass fraction in the stem but greater dry mass partitioned to the ear than the taller semi-dwarfs (Yecora rojo, IBWSN-199). Studies with detached heads confirm that the head is a significant sink in the shorter wheat cultivars.

Non-NASA Center↗