Fully quantum algorithm for mesoscale fluid simulations with application to partial differential equations

Fluid flow simulations marshal our most powerful computational resources. In many cases, even this is not enough. Quantum computers provide an opportunity to speed up traditional algorithms for flow simulations. We show that lattice-based mesoscale numerical methods can be executed as efficient quantum algorithms due to their statistical features. This approach revises a quantum algorithm for lattice gas automata to reduce classical computations and state preparation at every time step. For this, the algorithm approximates the qubit relative phases and subtracts them at the end of each time step. Phases are evaluated using the iterative phase estimation algorithm and subtracted using single-qubit rotation phase gates. Further, this method optimizes the quantum resource required and makes it more appropriate for near-term quantum hardware. We also demonstrate how the checkerboard deficiency that the D1Q2 scheme presents can be resolved using the D1Q3 scheme. The algorithm is validated by simulating two canonical partial differential equations: the diffusion and Burgers' equations on different quantum simulators. We find good agreement between quantum simulations and classical solutions for the presented algorithm.

97 MATHEMATICS AND COMPUTING↗

Efficient data-driven models for prediction and optimization of geothermal power plant operations

Increasing the capacity of geothermal energy as a renewable resource calls for development and deployment of efficient control and optimization technologies for geothermal power plants. A data-driven prediction and optimization model is presented as a cost-effective and efficient alternative to physics-based approach. The model predicts power output and operational cost by propagating the influence of control and disturbance variables within an artificial neural network (ANN). Numerical experiments with simulated and field data from a real geothermal power plant are first used to demonstrate the prediction performance of the ANN model. The model is then adopted to maximize the net predicted power production by automatically adjusting the working fluid circulation rate. The optimization performance of the model in evaluated using a thermodynamic flowsheet simulation model. The workflow is applied to model and control the effect of ambient temperature on an air-cooled binary cycle power plant, which is complex and costly to perform using a physics-based predictive model. As a result, the performance of the method is demonstrated by applying it to both simulated and field datasets from a binary cycle geothermal power plant.

15 GEOTHERMAL ENERGY↗

Evaporative chilling systems and methods using a selective transfer membrane

Compact membrane evaporative chillers, methods for cooling a process fluid (e.g., air) using a compact membrane evaporative chiller, and air conditioning systems and methods that include a compact membrane evaporative chiller are disclosed herein. Compact membrane evaporative chillers as disclosed herein can advantageously reduce or eliminate power consumption needed to circulate a working fluid.

Johnson, Brian↗

Two-Fluid and Discrete Element Modeling of a Parallel Plate Fluidized Bed Heat Exchanger for Concentrating Solar Power

A novel high-temperature particle solar receiver is developed using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a fluidized bed at the lower section, leaving the system from the bottom at a constant flowrate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built by collaborators at the Colorado School of Mines and their data are used for model validation. In this experimental setup, near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using the discrete element method and a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A new continuum conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2 K.

concentrating solar power↗

Superfluid effective field theory for dark matter direct detection

We develop an effective field theory (EFT) framework for superfluid 4 He to model the interactions among quasiparticles, helium atoms and probe particles. Our effective field theory approach brings together symmetry arguments and power-counting and matches to classical fluid dynamics. We then present the decay and scattering rates for the relevant processes involving quasiparticles and helium atoms. The presented EFT framework and results can be used to understand the dynamics of thermalization in the superfluid, and can be further applied to sub-GeV dark matter direct detection with superfluid 4 He.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature Homogeneity under Selective and Localized Microwave Heating in Structured Flow Reactors

Selective heating of different phases of multiphase systems via microwaves can result in energy savings and suppression of side reactions. However, materials properties and operating conditions that maximize temperature gradients are poorly understood. Here we utilize computational fluid dynamics (CFD) computations and temperature measurements in structured flow reactors (monoliths) in a monomodal microwave cavity to assess the temperature difference between the walls and the fluid and develop a simple lumped model to estimate when temperature gradients exist. We also explore the material’s thermal and electrical properties of structured reactors for isothermal catalyst conditions. We propose that CFD simulations can be used as a nonintrusive, predictive tool of temperature homogeneity. Importantly, we demonstrate that localized heating in the bed under several conditions rather than selective heating is responsible for the selectivity enhancement. Furthermore, our results indicate that structured beds made of high thermal conductivity materials avoid arcing and enable temperature homogeneity and low electrical conductivity materials allow microwaves to penetrate the domain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ALLOY SELECTION AND C-276 CODE DESIGN VALUE EXTENSION FOR ADVANCED MOLTEN SALT TECHNOLOGY TEST FACILITIES EXPERIMENTATION

Molten halide salts are being considered as working fluids for nuclear and concentrated solar power applications. High temperature molten fluoride and chloride salts are known to preferentially attack and deplete Cr in alloys, which leads to the use of high-Ni lower-Cr alloys in test facilities for advanced Molten Salt Technology. Alloys 600 and C-276 are two commercially available Ni alloys that have moderate Cr contents and are qualified to the maximum temperature of 649°C and 677°C (1,200°F and 1,251°F), respectively, in the Boiler and Pressure Vessel Code. Both alloys have good corrosion resistance to acids, are resistant to stress-corrosion cracking, and have long track records of use in the chemical industry. Comparatively, Alloy C-276 has a similar Cr content but much higher allowable stresses for temperatures greater than 600°C (1,112°F). Therefore, it has been considered as a structural material for test facilities that require operations at 700°C (1,292°F) or greater to develop high-temperature Molten Salt Technology. To meet the requirements, the current code design values were extended based on some experimental data. Analysis showed that above current Codified maximum temperature, strength of the alloy is mainly controlled by creep rupture life under the average stress, although the Sc creep rate criterion is close to the Favg.Savg rupture criterion. This paper presents the intended test facilities and the design requirements, alloy selection considerations, literature review, data analysis, and proposed allowable stress extension based on some creep test data for C-276 at temperatures greater than 677°C (1,251°F). Further research activities are also briefly mentioned.

Ren, Weiju↗

The ASD Scorpius Accelerator at the NNSS. Recruitment Slides for the University of Nevada, Reno [Slides]

The Scorpius Accelerator: Supports the maintenance of the US nuclear stockpile, helps the US not return to nuclear testing, is one of four diagnostics being installed 963 feet below ground, probes subcritical implosions of nuclear material, and supports the validation of LANL and LLNL computer codes. We are searching engineers and scientists with experienced in: Mechanical Engineering, Electrical Engineering, Pulsed Power, Plasma Physics, Controls, Diagnostics, and Fluids and pressure systems.

42 ENGINEERING↗

DPE Techno-Economic Analyses

This National Energy Technology Laboratory (NETL) report presents the results of an extensive set of techno-economic analyses for several open-cycle coal fuel oxy-fired direct power extraction (DPE) concepts. These power cycles make use of a conducting plasma accelerated through a magnetic field to generate direct current directly without the need for moving parts. Similar to gas turbines, the efficiency of the power cycle increases with increasing working fluid temperature and typically, plasma temperatures are much higher than the inlet temperature of even the most advanced gas turbine available today, affording the opportunity for very high cycle efficiencies. Most of the study uses high-fidelity models to assess a coal-fueled oxy-combustion DPE system with an AUSC steam bottoming cycle. Two baseline configurations were explored, one with relatively conservative operating point parameters and another with relatively aggressive operating point parameters. Additional analysis on the high-fidelity models as well as reduced order models were performed to analyze the cost and performance potential more thoroughly for the baseline systems and to compare their performance to two alternate open-cycle DPE systems.

30 DIRECT ENERGY CONVERSION↗

Ultra efficient turbo-compression cooling systems

Aspects of the present disclosure include a system for turbo-compression cooling. The system may be aboard a marine vessel. The system includes a power cycle and a cooling cycle. The power cycle includes a first working fluid, a waste heat boiler configured to evaporate the working fluid, a turbine, and a condenser. The condenser condenses the working fluid to a saturated or subcooled liquid. The cooling cycle includes a second working fluid, a first compressor configured to increase the pressure of the second working fluid, a condenser configured to condense the second working fluid to a saturated or subcooled liquid after exiting the first compressor, an expansion valve, and an evaporator. The turbine and first compressor are coupled one to the other. The waste heat boiler receives waste heat from engine jacket water and lubricating oil from a ship service generator. The evaporator cools water in a shipboard cooling loop.

Bandhauer, Todd M.↗

Self-powered Heating: Efficiency Analysis

Conventional fuel-fired heating devices such as furnaces, boilers, and water heaters have fuel efficiency less than 100% on the basis of higher heating value. They also require electricity from the electric grid to power parasitic loads such as blowers, pumps, fans, and ignitors. The primary energy efficiency of the device accounts for both fuel used on-site and primary energy used off-site to produce electric power used by the device. This work compares conventional fuel-fired heating devices to two types of self-powered devices. A self-powered device (SPD) integrates a power cycle onboard to eliminate consumption of grid electricity. We assume that all heat rejected by the onboard power cycle is added to the process fluid, so that, compared with a conventional device, the same amount of heat is provided to the process fluid and the same amount of fuel is consumed, but grid electricity consumption is eliminated. The first SPD type is the basic one: exactly the electricity required is generated. The second type considered is the SPD with heat pump (SPD-HP), in which the power cycle generates more electricity than needed for parasitic loads, and the excess electricity is used to power a heat pump. The heat pump extracts additional heat from the ambient to boost efficiency. Both SPD and SPD-HP self-consume all the generated electricity, in contrast to combined heat and power (CHP) systems that export electricity. In this work, equations are derived to express the efficiency of three classes of heating devices: conventional (consuming grid electricity), self-powered (consuming no grid electricity), and self-powered with heat pump. The efficiency of each is derived as a function of up to six factors: (1) the fraction of combustion heat captured, (2) the rate of parasitic power consumption, (3) the fraction of electric energy dissipated as useful heat, (4) the power cycle conversion efficiency, (5) the grid efficiency, when applicable, and (6) the heat pump COP, when applicable. Scenarios are identified in which it is possible to achieve efficiency greater than 100% on a higher heating value basis. Plausible configurations using existing technology options are outlined.

Gluesenkamp, Kyle↗

Optimization of Fairing Geometry for ORPC Modular RivGen Power System: Cooperative Research and Development (Final Report)

The work will optimize the hydrodynamic performance and flow augmentation of Ocean Renewable Power Company's (ORPC) modular fairing for their cross-flow marine hydrokinetic (MHK) turbine, using a computational fluid dynamics study. The influence of the fairing cross-sectional shape and rotor-fairing spacing will be assessed, to maximize power production and minimize structural loads.

16 TIDAL AND WAVE POWER↗

Waste heat recovery system and control

A waste heat recovery (WHR) system that can be utilized in internal combustion engine systems includes at least two circuits, one having a low pressure working fluid and another having a high pressure working fluid. Each circuit can include heat exchangers to allow the working fluid to absorb heat form one or more heat source fluids associated with the engine. The system can also include an expander configured to receive the working fluid from the at least two circuits, and generating mechanical power. The system also can include a condenser, a sub cooler, and at least one working fluid pump to pump the working fluid in the at least two circuits. The cooling system also includes a controller that can receive temperature and pressure values from various locations in the WHR system and control at least the flow rates of the working fluids in the at least two circuits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High temperature synthesis for power production and storage

A reservoir for containing a fluid includes a cylindrical wall sized to engage a shaft bored into ground, a bottom end cap fixed to a lower end of the cylindrical wall and a top end cap fixed to an upper end of the cylindrical wall. The top end cap is concave such that the top end cap extends below a top end of the cylindrical wall. The bottom end cap, the top end cap, and the cylindrical wall define a subterranean chamber. A plug made of a composite material is on the top end cap, with a lower face disposed on the concave top end cap and a peripheral face engaging the shaft. At least one pressure port extends downwardly into the shaft and through the plug and the top end cap, defining a fluid path to the subterranean chamber.

Lovegrove, Keith↗

Comparison of Thermal Management Approaches for Integrated Traction Drives in Electric Vehicles

The continuous push to increase power densities of electric vehicle (EV) traction drive systems necessitates combining electric motor and power electronics into one unit. A single, compact traction drive unit with fewer interconnecting components also facilitates fast, automated assembly of electric vehicles, driving production costs down and enabling wider adoption of EVs. There are a number of challenges associated with the integration of power electronics with the electric machine, including thermal management of the combined traction drive system. However, one important benefit of integration from the thermal management system perspective is the potential for using a single fluid loop instead of two separate cooling systems for the electric machine and the power electronics/inverter. This paper reviews several integration approaches and, employing finite element analysis (FEA), compares thermal management solutions for the combined electric machine and power electronics systems. Namely, three different scenarios are modeled: (1) independent component (motor and power electronics) cooling, which is compared to the combined cooling system approach for (2) radially and (3) axially integrated power electronics modules into the motor enclosure. Temperature distributions for selected thermal loads and thermal resistances from the key heat-generating components to the cooling fluid are compared for each scenario.

47 OTHER INSTRUMENTATION↗

Foreword: Special Section on Multiphysics Aspects of Power Electronics Packaging - Power Die, Power Module, and Converter Level - Part 1

Power electronics are increasingly being used to condition electricity for a wide array of applications, such as transportation (on land, air, and water), data centers, radio frequency, directed energy, wind, solar, and grid-tied applications. To increase power density, performance, efficiency, and reliability and reduce cost, innovations and developments are needed in the multiphysics packaging of power electronics at a die, module, and converter level. This includes fundamental research and development related to emerging high-voltage, high-temperature, and high-switching-frequency power electronics; packaging materials; thermal materials and interfaces; fluid-based thermal management technologies; reliability; condition monitoring; and prognostics. To address these important aspects, this Special Section on Multiphysics Aspects of Power Electronics Packaging includes several articles to be published in two parts. More details are given below on the articles included in the first part.

condition monitoring↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Hypothesis of Hot Tank Failure

Work has begun on a Design Basis Document / Owner’s Technical Specification for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. A principal topic of recent interest is the failures of the hot salt tanks in central receiver projects. The paper outlines a hypothesis for the source of the failures, and discusses a range of possible solutions.

14 SOLAR ENERGY↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗