Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY MULTIPLIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Visual evaluation of nystagmus intensity in points to diagnose vestibular dysfunction

The amplitude of nystagmus multiplied by its frequency gives a value commensurate to the velocity of slow phase. If the amplitude and the frequency during the visual observation are expressed in relative units (e.g., in points ranging from 1 to 3) the results of multiplication are used for a relative evaluation of nystagmus intensity. The relative evaluation of nystagmus intensity is used to compare the responses and, in particular, to calculate the coefficients of labyrinth asymmetry and of directional preponderance. A suggestion is made to analyze the formal results of caloric tests using a simple graphic model reflecting the left-right interactions by which the obtained coefficients are conditioned.

Levashov, M. M.↗

GaAs Schottky barrier varactor diodes for submillimeter wavelength power generation

The development of GaAs Schottky barrier diodes for frequencies well into the submillimeter wavelength range is discussed. These devices have the highest cutoff frequencies yet obtained for varactor diodes and have produced sufficient output power to drive Schottky mixers at frequencies as high as 640 GHz. The fundamental design tradeoff between cutoff frequency and capacitance modulation is explored. As the doping density is increased and the anode diameter is reduced, the dynamic cutoff frequency increases, reaching a maximum of roughly 5 THz. It is concluded that the maximum output frequency from harmonic multipliers based on standard GaAs varactor diodes will be about 1 THz.

Crowe, T. W.↗

Submillimeter Laboratory Investigations: Spectroscopy and Collisions

Currently, millimeter-wave and submillimeter-wave spectroscopy is conducted in our laboratory on several different types of spectrometers. Our standard spectrometer utilizes the output of a phase-locked klystron operating in the 40-60 GHz region, which is sent into a crossed-waveguide harmonic generator, or "multiplier". The high frequency millimeter-and submillimeter-wave radiation is transmitted via quasi-optical techniques through an absorption cell and then onto a detector, which is either an InSb hot electron bolometer cooled to 1.4 K or a Si bolometer cooled to 0.3 K. The detector response is sent to a computer for measurement and analysis. The frequency range produced and detected in this manner goes from 80 GHz to upwards of 1 THz. Spectra are normally taken with source modulation, with line frequencies typically measured to an accuracy of 50-100 kHz. Higher accuracy is available when needed. Recently, we developed a new, broad-band spectrometer in our laboratory based on a free-running backward wave oscillator (BWO) of Russian manufacture as the primary source of radiation. The so-called FASSST (fast-scan submillimeter spectroscopic technique) system uses fast-scan and optical calibration methods rather than the traditional locking techniques. The output power from the BWO is split such that 90% goes into the absorption cell while 10% is coupled to a 40-meter Fabry-Perot cavity, which yields fringe? for frequency measurement. Results from this spectrometer on the spectrum of nitric acid (HNO3) show that 100 GHz of spectral data can be obtained in 5 seconds with a measurement accuracy of 50 kHz. Currently, the frequency range of the FASSST system in our laboratory is roughly 100-700 GHz.

Herbst, Eric↗

Design and Analysis of Broad-Band Fixed-Tuned Submillimeter-Waveguide Multipliers using MMIC Style Circuit Topology

The design and analysis of varactor diode doubler, quadrupler and cascaded doubler circuits for 320 and 640 GHz have been completed. A new approach has been employed to produce a tunerless waveguide mount with a very flexible, frequency scaleable, MMIC style multiplier circuit. The concept, design, predicted performance and measurements on some of the constituent mount elements are presented.

varactor diode doubler MMIC style multiplier circu↗

A detector for high frequency modulation in auroral particle fluxes

A high time resolution electron detector has been developed for use in sounding rocket studies of the aurora. The detector is used to look for particle bunching in the range 50 kHz-10 MHz. The design uses an electron multiplier and an onboard frequency spectrum analyzer. By using the onboard analyzer, the data can be transmitted back to ground on a single 93-kHz voltage-controlled oscillator. The detector covers the 50 kHz-10 MHz range six times per second and detects modulation on the order of a new percent of the total electron flux. Spectra are presented for a flight over an auroral arc.

Spiger, R. J.↗

Frequency analysis of 4- to 6-keV electrons associated with an auroral arc

The high time resolution (HTR) experiment considered consists of four sections, including electrostatic deflection plates, electron multiplier, preamplifier-integrator, and frequency analyzer. Electrons in the energy range from 4 to 6 keV electrons are selected by the deflection system, after which they are detected, multiplied, and passed to the charge sensitive preamplifier. The charge pulses are amplified and integrated, and the resulting voltage pulse series is fed to the frequency analyzer. The experiment is essentially a flux detector, so that estimates of the input flux can be made from the mean value of the output spectrum. The results obtained with the HTR in a rocket flight on March 14, 1974, are discussed. The lack of modulation noticed in the high-frequency range indicates that there is insufficient wave energy available in the vicinity of the rocket to produce a wave-particle interaction which the HTR is able to observe. This finding is consistent with the stabilization of the plasma by the low flux of energetic electrons.

Murphree, J. S.↗

Current saturation in submillimeter wave varactors

In semiconductor devices the speed of electrons cannot exceed certain limits. This phenomenon will affect varactor multipliers as well as other high frequency devices where the RF current through the active part of the device is primarily displacement current. Hence, 'saturation' of the varactor output power is expected at some point. This phenomenon is discussed in some detail and shown to severely deteriorate the multiplier performance at higher frequencies. Single barrier varactors should have an advantage over GaAs Schottky diode varactors because they can be fabricated on InAs and stacked in a series array, allowing for lower current densities and higher power handling.

Kollberg, Erik L.↗

Spectral analysis of oscillation instabilities in frequency standards

Phase and frequency fluctuations, inherent in oscillators used as frequency standards, are measured over spectral frequency range of 1 Hz to 5 kHz. Basic measurement system consists of electromechanical phase-locked loop that extracts phase and frequency fluctuations and error multiplier that extends threshold sensitivity.

Lippincott, S.↗

Two-carrier command modulation system

Two carriers transmit two high-power signals from single transmitter, each phase-modulated by subcarrier which, in turn, is modulated by data bits; switching between two carriers is alternated at high rate. Resulting composite signal is multiplied up to desired frequency and used to drive power amplifier which feeds transmitting antenna.

Easterling, M. F.↗

The Upper Atmosphere Research Satellite microwave limb sounder instrument

The microwave limb sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) is the first satellite experiment using limb sounding techniques at microwave frequencies. Primary measurement objectives are stratospheric ClO, O3, H2O, temperature, and pressure. Measurements are of thermal emission: all are performed simultaneously and continuously and are not degraded by ice clouds or volcanic aerosols. The instrument has a 1.6-m mechanically scanning antenna system and contains heterodyne radiometers in spectral bands centred near 63, 183, and 205 GHz. The radiometers operate at ambient temperature and use Schottky-diode mixers with local oscillators derived from phase-locked Gunn oscillators. Frequency tripling by varactor multipliers generates the 183- and 205-GHz local oscillators, and quasi-optical techniques inject these into the mixers. Six 15-channel filter banks spectrally resolve stratospheric thermal emission lines and produce an output spectrum every 2 s. Thermal stability is sufficient for 'total power' measurements which do not require fast chopping. Radiometric calibration, consisting of measurements of cold space and an internal target, is performed every 65-s limb scan. Instrument in-orbit performance has been excellent, and all objectives are being met.

Barath, F. T.↗

The 13th Technology of Deep Space One - Abstract

On October 24th, 1998, the Deep Space One (DS-1) spacecraft launched aboard a Delta II rocket as the first step towards the bold task of testing and validating 12 new technologies for future missions. This launch also represented yet another thrilling event; namely, the successful test and validation of a 13th heretofore undisclosed technology: model-based code-generation of the spacecraft's system-level fault-protection (FP) software from behavioral state diagrams and structural models.In this paper, we describe the process we used to leverage model-based code generation from state diagrams and structural specifications to better respond to the evolving requirements and scope of DS- I's system-level fault-protection design, development, test and operation. The evolution of the high-level design and the low-level changes in the flight software architecture and interfaces contributed to multiplying the number and frequency of fault-protection software releases thereby creating a multitude of software integration issues. To address the resulting software integration issues, we broadened the scope of code -eneration to other forms of model- based analysis techniques more traditionally associated with first-principle's reasoning about physical models. Additionally, we describe our in-flight launch and initial acquisition experience.

Rouquette, Nicolas↗

Method and apparatus for quadriphase-shift-key and linear phase modulation

A submultiple of an S-band transmitter output frequency was divided equally between a linear phase modulation branch and a QPSK modulation branch. The linear modulation branch includes a multiplier to increase the carrier frequency to a level which, when combined with the carrier in the QPSK branch in an up-converter (utilizing a mixer at the input followed by a bandpass filter), produces the transmitter output frequency. This allows the QPSK modulator to operate at one-eighth of the output frequency where repeatable and precisely controlled modulation can be easily achieved. This also allows linear phase modulation at one-eighth the output frequency where low modulator deviation and good linearity can be easily maintained.

Hermesmeyer, C. E.↗

Theoretical and simulated performance for a novel frequency estimation technique

A low complexity, open-loop, discrete-time, delay-multiply-average (DMA) technique for estimating the frequency offset for digitally modulated MPSK signals is investigated. A nonlinearity is used to remove the MPSK modulation and generate the carrier component to be extracted. Theoretical and simulated performance results are presented and compared to the Cramer-Rao lower bound (CRLB) for the variance of the frequency estimation error. For all signal-to-noise ratios (SNR's) above threshold, it is shown that the CRLB can essentially be achieved with linear complexity.

Crozier, Stewart N.↗

A High Efficiency Multiple-Anode 260-340 GHz Frequency Tripler

We report on the fabrication at the Jet Propulsion Laboratory of a fixed-tuned split-block waveguide balanced frequency tripler working in the 260-340 GHz band. This tripler will be the first stage of a x3x3x3 multiplier chain to 2.7 THz (the last stages of which are being fabricated at JPL) and is therefore optimized for high power operation. The multiplier features six GaAs Schottky planar diodes in a balanced configuration integrated on a GaAs membrane. Special attention was put on splitting the input power as evenly as possible among the diodes in order to ensure that no diode is overdriven. Preliminary RF tests indicate that the multiplier covers the expected bandwidth and that the efficiency is in the range 1.5-7.5 % with 100 mW of input power.

local oscillators↗

Optical Sidebands Multiplier

Optical sidebands have been generated with relative frequency tens to hundreds of GHz by using optical sidebands that are generated in a cascade process in high-quality optical resonators with Kerr nonlinearity, such as whispering gallery mode (WGM) resonators. For this purpose, the WGM resonator needs to be optically pumped at two frequencies matching its resonances. These two optical components can be one or several free spectral ranges (FSRs), equal to approximately 12 GHz, in this example, apart from each other, and can be easily derived from a monochromatic pump with an ordinary EOM (electro-optic modulation) operating at half the FSR frequency. With sufficient nonlinearity, an optical cascade process will convert the two pump frequencies into a comb-like structure extending many FSRs around the carrier frequency. This has a demonstratively efficient frequency conversion of this type with only a few milliwatt optical pump power. The concept of using Kerr nonlinearity in a resonator for non-degenerate wave mixing has been discussed before, but it was a common belief that this was a weak process requiring very high peak powers to be observable. It was not thought possible for this approach to compete with electro-optical modulators in CW applications, especially those at lower optical powers. By using the high-Q WGM resonators, the effective Kerr nonlinearity can be made so high that, using even weak seeding bands available from a conventional EOM, one can effectively multiply the optical sidebands, extending them into an otherwise inaccessible frequency range.

Strekalov, Dmitry V.↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗