Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The operational performance of hydrogen masers in the deep space network: The performance of laboratory reference frequency standards in an operational environment

Hydrogen masers used as aids in meeting the routine frequency and time operational requirements within the 64 m antenna Deep Space Network. Both the operational syntonation (frequency synchronization) and the the clock (epoch) synchronization requirements were established through the use of specifically calibrated H-P E215061A flying clock. The sync/synt to UTC was maintained using LORAN and TV in simultaneous reception mode. The sync/synt within the 64 m net was maintained through the use of very long base interferometry. Results indicate that the hydrogen masers perform well within the required specifications.

Ward, S. C.↗

Prospects for advances in microwave atomic frequency standards

Traditional standards based on rubidium, cesium and hydrogen have been greatly refined over the past decade, such that the frequency stability of the current generation of devices is generally limited by those basic concepts on which they are based. Future advances in frequency stability will principally come from changes in the concepts on which the standards are based, and only secondarily from more careful engineering of the old concepts. The fundamental limitations in these standards are considered and the important conceptual and component advances which could have a major impact on future performance of these standards are indicated. A very promising new class of microwave standards based on ion storage techniques is examined.

Walls, F. L.↗

A high performance frequency standard and distribution system for Cassini Ka-band experiment

This paper provides an overview and update of a specialized frequency reference system for the NASA Deep Space Network (DSN) to support Ka-band radio science experiments with the Cassini spacecraft, currently orbiting Saturn. Three major components, a Hydrogen Maser, Stabilized Fiber-optic Distribution Assembly (SFODA), and 10 Kelvin Cryocooled Sapphire Oscillator (10K CSO) and frequency-lock-loop, are integrated to achieve the very high performance, ground based frequency reference at a remote antenna site located 16 km from the hydrogen maser. Typical measured Allan Deviation is 1.6 -14 1 0a't 1 second and 1.7 x 10 -15 at 1000 seconds averaging intervals. Recently two 10K CSOs have been compared in situ while operating at the remote DSN site DSS-25. The CSO references were used operationally to downconvert the Ka band downlink received from the Cassini spacecraft in a series of occultation measurements performed over a 78 day period from March to June 2005.

sapphire↗

On the accuracy of Cs beam primary frequency standards

A new and much more exact method for evaluation of the velocity distribution in 10 to the 15th power of the frequency of the clock. It seems feasible to improve the accuracy even further with better measurements. The evaluation of the C-field, however, is still limited to a few parts in 10 to the 14th power because of the uncertainties linked to the method used, and this uncertainty remains one of the major limitations of NRC's primary clocks.

Boulanger, J. S.↗

New ion trap for atomic frequency standard applications

A novel linear ion trap that permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the radio frequency (RF) confining fields has been designed and built. This new trap should store about 20 times the number of ions a conventional RF trap stores with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced.

Prestage, J. D.↗

Hydrogen Masers as Time and Frequency Standards

Track each other with 100 times more precision than cesium standards. Geographically separated hydrogen masers tracked each other for more than year to within few parts in 10 to the 15th power. Frequency offset of hydrogen-maser output from hyperfine line frequency is function of ambient magnetic field, cavity mistuning, thermal motion of atoms in cavity and collisions of atoms with walls of the cavity. If maser remains at one location some of small offsets in frequency will remain constant throughout life of maser.

Ward, S. C.↗

Frequency standards based on ultracold atoms in tests of general relativity, navigation and gravimetry

Research and development in the field of optical clocks based on ultracold atoms and ions have enabled the relative uncertainty in frequency to be reduced down to a few parts in 10{sup 18}. The use of novel, precise frequency comparison methods opens up new possibilities for basic research (sensitive tests of general relativity, a search for a drift of fundamental constants and a search for ‘dark matter’) as well as for state-of-the-art navigation and gravimetry. We discuss the key methods that are used in creating precision clocks (including transportable clocks) based on ultracold atoms and ions and the feasibility of using them in resolving current relativistic gravimetry issues. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Blackbody radiation shift in the {sup 87}Rb frequency standard

The operation of atomic clocks is generally carried out at room temperature, whereas the definition of the second refers to the clock transition in an atom at absolute zero. This implies that the clock transition frequency should be corrected in practice for the effect of finite temperature, of which the leading contributor is the blackbody radiation (BBR) shift. Experimental measurements of the BBR shifts are difficult. In this work, we have calculated the blackbody radiation shift of the ground-state hyperfine microwave transition in {sup 87}Rb using the relativistic all-order method and carried out a detailed evaluation of the accuracy of our final value. Particular care is taken to accurately account for the contributions from highly excited states. Our predicted value for the Stark coefficient, k{sub S}=-1.240(4)x10{sup -10} Hz/(V/m){sup 2}, is three times more accurate than the previous calculation [E. J. Angstman, V. A. Dzuba, and V. V. Flambaum, Phys. Rev. A 74, 023405 (2006)].

74 ATOMIC AND MOLECULAR PHYSICS↗

Frequency shifts in a rubidium frequency standard due to coupling to another standard

Highly reliable timing system, such as used on board satellites, may incorporate a hot standby atomic clock besides the active one. RF couplings between them may affect the performance of the active clock. The effect of such couplings between two rubidium atomic clocks was investigated, and it was found that they will add an oscillatory term to the Allan Variance of the active clock, degrading its frequency stability, and that under certain circumstances they may also shift the active clock's operating frequency. These two effects are discussed in detail, and the level of isolation required to render them negligible is established.

Jaduszliwer, Bernardo↗

New ion trap for frequency standard applications

A novel linear ion trap was designed, which permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. This new trap should store about 20 times the number of ions as a conventional RF trap with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced.

Prestage, J. D.↗

Linear ion trap for second-order Doppler shift reduction in frequency standard applications

The authors have designed and are presently testing a novel linear ion trap that permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. This new trap should store about 20 times the number of ions as a conventional RF trap with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced. The authors have succeeded in trapping mercury ions and xenon ions in the presence of helium buffer gas. Trap times as long as 2000 s have been measured.

Prestage, John D.↗

Studies on Temperature Dependence of Rubidium Lamp for Atomic Frequency Standard

Rb lamp is a very critical component of the Rb atomic clock's Physics Package. The Rb lamp's performance is very sensitive to temperature and its stability. In this paper we discuss the behaviors of Rb Lamp with temperature. The Rb lamp exciter power and temperature of Rb bulb are very important parameters in controlling the performance of the Rb Lamp. It is observed that at temperatures beyond 110 deg. C, the lamp mode changes from the ring to red mode resulting in abnormal broadening of emission lines and self reversal. The results of our studies on spectral analysis of Rb lamp under various operating conditions are reported in the paper.

74 ATOMIC AND MOLECULAR PHYSICS↗

Study of the parameters of a single-frequency laser for pumping cesium frequency standards

A model for calculating the parameters of a laser diode with an external fibre cavity containing a fibre Bragg grating (FBG) is presented. It is shown that by using this model, it is possible to obtain single-mode lasing by neglecting the spectral burning of carriers. The regions of the laser-diode current and temperature and the FBG temperature in which the laser can be tuned to the D{sub 2} line of cesium are determined experimentally. (lasers and amplifiers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectral characteristics of a laser emitter designed for pumping and detecting a reference quantum transition of a caesium frequency standard

Experimental and calculated spectral characteristics of a diode laser with a Bragg grating soldered on a thermoelectric cooler are presented. A model of the laser is developed, which takes into account the pressure arising after soldering the Bragg grating on the thermoelectric cooler, as well as temperature and dispersion. Theoretical and experimental spectral characteristics of the laser are compared and their satisfactory agreement is shown. (control of radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗