Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault Injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology

The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. Furthermore this has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

DOE 10658 Project Sensitivity-Driven Wide Area Protection (SWAP) Coordination Tools for IBRs

Utilities have seen a rapid increase in solar, wind, and battery energy storage systems that interconnect to their electric system through inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well-known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protects the inverter’s sensitive power electronics devices from damage from conditions such as overcurrent. This results in a low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufacturers and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of focusing on one issue, this report looks broadly at all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspectives from different utility SMEs via questionnaire, the report summarizes the gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

A general software reliability process simulation technique

The structure and rationale of the generalized software reliability process, together with the design and implementation of a computer program that simulates this process are described. Given assumed parameters of a particular project, the users of this program are able to generate simulated status timelines of work products, numbers of injected anomalies, and the progress of testing, fault isolation, repair, validation, and retest. Such timelines are useful in comparison with actual timeline data, for validating the project input parameters, and for providing data for researchers in reliability prediction modeling.

Tausworthe, Robert C.↗

NASA systems autonomy demonstration project: Advanced automation demonstration of Space Station Freedom thermal control system

The NASA Systems Autonomy Demonstration Project (SADP) was initiated in response to Congressional interest in Space station automation technology demonstration. The SADP is a joint cooperative effort between Ames Research Center (ARC) and Johnson Space Center (JSC) to demonstrate advanced automation technology feasibility using the Space Station Freedom Thermal Control System (TCS) test bed. A model-based expert system and its operator interface were developed by knowledge engineers, AI researchers, and human factors researchers at ARC working with the domain experts and system integration engineers at JSC. Its target application is a prototype heat acquisition and transport subsystem of a space station TCS. The demonstration is scheduled to be conducted at JSC in August, 1989. The demonstration will consist of a detailed test of the ability of the Thermal Expert System to conduct real time normal operations (start-up, set point changes, shut-down) and to conduct fault detection, isolation, and recovery (FDIR) on the test article. The FDIR will be conducted by injecting ten component level failures that will manifest themselves as seven different system level faults. Here, the SADP goals, are described as well as the Thermal Control Expert System that has been developed for demonstration.

Dominick, Jeffrey↗

Modeling, Detection, and Disambiguation of Sensor Faults for Aerospace Applications

Sensor faults continue to be a major hurdle for systems health management to reach its full potential. At the same time, few recorded instances of sensor faults exist. It is equally difficult to seed particular sensor faults. Therefore, research is underway to better understand the different fault modes seen in sensors and to model the faults. The fault models can then be used in simulated sensor fault scenarios to ensure that algorithms can distinguish between sensor faults and system faults. The paper illustrates the work with data collected from an electro-mechanical actuator in an aerospace setting, equipped with temperature, vibration, current, and position sensors. The most common sensor faults, such as bias, drift, scaling, and dropout were simulated and injected into the experimental data, with the goal of making these simulations as realistic as feasible. A neural network based classifier was then created and tested on both experimental data and the more challenging randomized data sequences. Additional studies were also conducted to determine sensitivity of detection and disambiguation efficacy to severity of fault conditions.

Balaban, Edward↗

Lightning Pin Injection Testing on MOSFETS

Lightning transients were pin-injected into metal-oxide-semiconductor field-effect transistors (MOSFETs) to induce fault modes. This report documents the test process and results, and provides a basis for subsequent lightning tests. MOSFETs may be present in DC-DC power supplies and electromechanical actuator circuits that may be used on board aircraft. Results show that unprotected MOSFET Gates are susceptible to failure, even when installed in systems in well-shielded and partial-shielded locations. MOSFET Drains and Sources are significantly less susceptible. Device impedance decreased (current increased) after every failure. Such a failure mode may lead to cascading failures, as the damaged MOSFET may allow excessive current to flow through other circuitry. Preliminary assessments on a MOSFET subjected to 20-stroke pin-injection testing demonstrate that Breakdown Voltage, Leakage Current and Threshold Voltage characteristics show damage, while the device continues to meet manufacturer performance specifications. The purpose of this research is to develop validated tools, technologies, and techniques for automated detection, diagnosis and prognosis that enable mitigation of adverse events during flight, such as from lightning transients; and to understand the interplay between lightning-induced surges and aging (i.e. humidity, vibration thermal stress, etc.) on component degradation.

Ely, Jay J.↗

IBR Black Model Lessons Learned (C45)

Blackbox modelling for SC analysis is a possible solution. Accuracy can be acceptable even without having vendor control diagrams. Blackbox modelling is not as user friendly as a generic model. Is an NDA required to share a vendor Blackbox model for SC analysis? Difference in VRT detection and injection logics. Angle rotation is not addressed. Current limitation logic during unbalanced faults is not clear.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SMART – A Comprehensive Research and Development Program to Demonstrate Application of Machine Learning for Supporting CCS Deployment

Presentation material for a paper presented at the GHGT-17 conference, Calgary, Canada, October 20-24, 2024. The objective of the US Department of Energy’s SMART Initiative, i.e., Science-informed Machine Learning (ML) for Accelerating Real-Time Decisions in Subsurface Applications, is to showcase how the utilization of ML can significantly improve efficiency and effectiveness of field-scale commercial carbon storage operations. This paper will present the results from the current phase of SMART (field deployment) for demonstrating the applicability of ML-based tools and workflows for: (a) virtual learning during the pre-injection permitting phase, (b) advanced storage reservoir imaging to better characterize fractures and faults, and (c) dynamic storage reservoir modelling and optimization to inform operational decision making and visualization of system evolution.

CO2 geologic storage↗

In-flight demonstration of hybrid GPS/Loran RAIM

A receiver autonomous integrity monitoring (RAIM) scheme has been implemented in a real time, prototype hybrid GPS/LORAN receiver. A four-channel GPS receiver and an eight-channel LORAN-C receiver are used to obtain raw GPS and LORAN pseudorange measurements. The measurement data is sent to a microcomputer for position and integrity determination. Navigation data is presented to the pilot on a standard course deviation indicator with a data renewal rate of up to one update per second. Provisions are made to simulate signal malfunctions in real time by injecting step or ramp failures in the pseudorange measurements. A least-squares fault detection algorithm is presented for the detection of slowly growing measurement errors. The performance of the hybrid GPS/LORAN receiver has been demonstrated through actual flight tests. One of the flight tests is summarized in the paper.

Van Graas, Frank↗

SMART – A Comprehensive Research and Development Program to Demonstrate Application of Machine Learning for Supporting CCS Deployment

The objective of the US Department of Energy’s SMART Initiative, i.e., Science-informed Machine Learning (ML) for Accelerating Real-Time Decisions in Subsurface Applications, is to showcase how the utilization of ML can significantly improve efficiency and effectiveness of field-scale commercial carbon storage operations. This paper will present the results from the current phase of SMART (field deployment) for demonstrating the applicability of ML-based tools and workflows for: (a) virtual learning during the pre-injection permitting phase, (b) advanced storage reservoir imaging to better characterize fractures and faults, and (c) dynamic storage reservoir modelling and optimization to inform operational decision making and visualization of system evolution.

Siriwardane, Hema↗

Machine Learning Approaches to Predicting Induced Seismicity and Imaging Geothermal Reservoir Properties

This project developed machine learning (ML) methods, lab data sets, and field data to advance geothermal exploration and geothermal energy production. The work had three focus areas. One involved the development of ML methods to use microearthquakes (MEQs) for imaging geothermal reservoir properties and improving subsurface characterization – most importantly the evolution of permeability within the evolving reservoir. This part of the work included development of ML approaches for automated MEQ location, focal mechanism determination and identification of earthquake precursors. The second area focused on using MEQ signals generated by geothermal exploration and production to predict the relationship between fluid injection and seismicity. Here, we extended to reservoir scale our success in using ML to predict laboratory earthquakes and fault zone stress state. The third focus area was on lab experiments. Here, we developed new ML models for lab earthquake prediction and identification of precursors to failure to improve earthquake forecasting and early warning in geothermal settings. Major outcomes of our work include ML models that learn from MEQ signals during geothermal exploration and production to predict induced seismicity. MEQs occur naturally in connection with drilling and energy production. We developed ML methods to use the seismic waves from these events to characterize the elastic, hydraulic and poromechanical properties of reservoirs. Our work illuminated fracture geometry and the evolution of fracture permeability by incorporating seismic coda wave analysis and ML methods to relate fluid injection and seismicity. We significantly expanded laboratory earthquake prediction to include methods that use both passive measurements of microearthquakes within the lab fault zones and also active source acoustic measurements of fault zone elastic properties. These methods can now predict fault zone stress state, time to failure and the magnitude of lab earthquakes. Our work showed that repetitive stick- slip failure events during frictional sliding (the lab equivalent of earthquakes) are preceded by a cascade of micro-failure events that radiate energy in a manner that foretells unstable failure – manifest as laboratory MEQs. We documented a mapping between fracture properties and statistical attributes of elastic radiation. We extended existing works to geothermal reservoir scale and developed ML methods to determine reservoir permeability, fracture properties, and their evolution during geothermal energy production. An attractive feature of ML algorithms is their ability to handle big datasets and reveal patterns and correlations that may remain invisible to conventional analyses. Our work connected data from field, laboratory and intermediate scales to study permeability, stress, strength, fracture stiffness and geometry. At the field scale we used data from the Newberry Volcano field site, UtahFORGE, EGS Collab, and also the Bedretto underground research lab in Switzerland. These data sets are bridging the gap between the lab scale, theory, and reservoir scale. Our work produced plain language summaries to improve public understanding of DOE research. We also developed openly distributed ML and seismicity datasets for use by all researchers and we published connections between induced seismicity in geothermal areas and reservoir properties including permeability, fracture properties, and stress state. Our models are designed for the large data sets of induced seismicity typically associated with geothermal sites. We produced labeled event catalogs and used them on geothermal data to assess how ML can facilitate geothermal production and exploration. All datasets are available on the GDR Productivity: The project produced 32 publications in peer reviewed journals (two are in review). It supported the work of 6 PhD students, 40 conference presentations, 6 keynote talks at national meetings, and mentoring and professional development for 4 postdoctoral fellows.

15 GEOTHERMAL ENERGY↗

Analog-digital simulation of transient-induced logic errors and upset susceptibility of an advanced control system

A simulation study is described which predicts the susceptibility of an advanced control system to electrical transients resulting in logic errors, latched errors, error propagation, and digital upset. The system is based on a custom-designed microprocessor and it incorporates fault-tolerant techniques. The system under test and the method to perform the transient injection experiment are described. Results for 2100 transient injections are analyzed and classified according to charge level, type of error, and location of injection.

Carreno, Victor A.↗

MRCI Subtask 2.2: Precambrian Basement Structure, Faulting, and Stress Final Technical Summary Report

Subtask 2.2 was largely focused on compiling information about the Precambrian basement rock that underlies the MRCI region. Understanding the nature and extent of the basement rock is important in order to mitigate certain risks associated with CO2 injection. For example, this information will provide a resource for defining areas where a storage reservoir is in direct contact with the Precambrian or indirectly via a fault. Also, an understanding of the stress field in addition to fault orientations will help determine which faults may be subject to reactivation under increased pore pressures.

Battelle,CCS,CCUS,Carbon storage,MRCI,Midwest Regi↗

An experimental study of fault propagation in a jet-engine controller

An experimental analysis of the impact of transient faults on a microprocessor-based jet engine controller, used in the Boeing 747 and 757 aircrafts is described. A hierarchical simulation environment which allows the injection of transients during run-time and the tracing of their impact is described. Verification of the accuracy of this approach is also provided. A determination of the probability that a transient results in latch, pin or functional errors is made. Given a transient fault, there is approximately an 80 percent chance that there is no impact on the chip. An empirical model to depict the process of error exploration and degeneration in the target system is derived. The model shows that, if no latch errors occur within eight clock cycles, no significant damage is likely to happen. Thus, the overall impact of a transient is well contained. A state transition model is also derived from the measured data, to describe the error propagation characteristics within the chip, and to quantify the impact of transients on the external environment. The model is used to identify and isolate the critical fault propagation paths, the module most sensitive to fault propagation and the module with the highest potential of causing external pin errors.

Choi, Gwan Seung↗