Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field and particle detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The potential of a TeV-scale muon-ion collider

We propose the development of a novel muon-proton and muon-nucleus collider facility at the TeV scale that is capable of performing precision deep inelastic scattering measurements in new regimes and providing a rich program in nuclear and particle physics. Such a facility could seed, or leverage, the development of a muon-antimuon collider and make use of the existing hadron accelerator infrastructure when sited at a facility such as Brookhaven National Laboratory, Fermilab, or CERN. Here, we discuss the possible energy and luminosity design parameters for several collider configurations, and illustrate the science potential with several studies on deep inelastic scattering kinematics, Higgs and vector boson production, top quark production, and beyond Standard Model leptoquark production. Detector design considerations and a possible road map toward development are also given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strategies and performance of the CMS silicon tracker alignment during LHC Run 2

The strategies for and the performance of the CMS silicon tracking system alignment during the 2015-2018 data-taking period of the LHC are described. The alignment procedures during and after data taking are explained. Alignment scenarios are also derived for use in the simulation of the detector response. Systematic effects, related to intrinsic symmetries of the alignment task or to external constraints, are discussed and illustrated for different scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark Photon Search at the Short-Baseline Near Detector

Neutrino physics has long been a key field in elementary particle physics, both enhancing our understanding of the Standard Model (SM) and raising new questions. Among these are the so-called "Short-Baseline Anomalies" observed by neutrino experiments, particularly the MiniBooNE experiment at Fermilab, which detected an excess of low-energy electron-like events. In recent years, beyond Standard Model (BSM) explanations have been proposed to address this anomaly, with a focus on neutrino beam-related processes. A novel interpretation involving a dark-sector explanation was recently suggested, introducing a vector portal that connects the SM and dark sectors through a new interaction mediated by a bosonic particle, the Dark Photon. This work investigates the production of dark-sector particles, specifically Dark Photons, in the Booster Neutrino Beam (BNB) at Fermilab and their potential detection at the Short-Baseline Near Detector (SBND). The BNB produces mesons which decay into Dark Photons, detectable via their decay into electron-positron pairs at SBND. By exploiting the temporal structure of the neutrino beam, we propose a method to isolate Dark Photon signals from neutrino backgrounds using time-delayed event detection. In this thesis, the sensitivity of SBND to Dark Photons is assessed using a three-year exposure, demonstrating that SBND has the potential to significantly improve current experimental constraints on Dark Photons. This analysis provides a promising avenue for future dark sector searches in neutrino experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Snowmass2021 CMB-HD White Paper

CMB-HD is a proposed millimeter-wave survey over half the sky that would be ultra-deep (0.5 uK-arcmin) and have unprecedented resolution (15 arcseconds at 150 GHz). Such a survey would answer many outstanding questions about the fundamental physics of the Universe. Major advances would be 1.) the use of gravitational lensing of the primordial microwave background to map the distribution of matter on small scales (k~10 h Mpc^(-1)), which probes dark matter particle properties. It will also allow 2.) measurements of the thermal and kinetic Sunyaev-Zel'dovich effects on small scales to map the gas density and velocity, another probe of cosmic structure. In addition, CMB-HD would allow us to cross critical thresholds: 3.) ruling out or detecting any new, light (< 0.1 eV) particles that were in thermal equilibrium with known particles in the early Universe, 4.) testing a wide class of multi-field models that could explain an epoch of inflation in the early Universe, and 5.) ruling out or detecting inflationary magnetic fields. CMB-HD would also provide world-leading constraints on 6.) axion-like particles, 7.) cosmic birefringence, 8.) the sum of the neutrino masses, and 9.) the dark energy equation of state. The CMB-HD survey would be delivered in 7.5 years of observing 20,000 square degrees of sky, using two new 30-meter-class off-axis crossed Dragone telescopes to be located at Cerro Toco in the Atacama Desert. Each telescope would field 800,000 detectors (200,000 pixels), for a total of 1.6 million detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ATLAS Fast TracKer system

The ATLAS Fast TracKer (FTK) was designed to provide full tracking for the ATLAS high-level trigger by using pattern recognition based on Associative Memory (AM) chips and fitting in high-speed field programmable gate arrays. The tracks found by the FTK are based on inputs from all modules of the pixel and silicon microstrip trackers. The as-built FTK system and components are described, as is the online software used to control them while running in the ATLAS data acquisition system. Also described is the simulation of the FTK hardware and the optimization of the AM pattern banks. An optimization for long-lived particles with large impact parameter values is included. A test of the FTK system with the data playback facility that allowed the FTK to be commissioned during the shutdown between Run 2 and Run 3 of the LHC is reported. The resulting tracks from part of the FTK system covering a limited $\eta$-$\phi$ region of the detector are compared with the output from the FTK simulation. It is shown that FTK performance is in good agreement with the simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D Integrated Sensing Solutions

We will present the proposed research project to develop 3D-integrated sensors using advanced manufacturing capability for novel sensors, heterogeneously integrated with energy efficient readout circuits. The lack of precision timing in particle tracking detectors and the absence of low power, high throughput communications solutions to read them out limits progress in multiple fields of fundamental science. The aim of the project is to develop technology to enable large-scale particle detectors with 3D-integrated ASIC designs to simultaneously achieve 10 μm position resolution and 10 ps precision timing, with low-power consumption and high throughput rates. This research program leverages the unique combination of facilities and cross-disciplinary expertise of scientists and engineers at SLAC, FNAL, and LLNL and industrial partners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches

We report that large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay (0νββ) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas- or liquid-phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomena. The key challenge to extending this technology to detectors well beyond the ton scale is the acquisition of the Xe itself. We describe the motivation for extending Xe time-projection chambers to the kton scale and possible avenues for Xe acquisition that avoid existing supply chains. If acquisition of Xe in the required quantities is successful, kton-scale detectors of this type could enable a new generation of experiments, including searches for 0νββ at half-life sensitivities as long as 10 30 yr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prediction of Leakage Current and Depletion Voltage in Silicon Detectors Under Extraterrestrial Radiation Conditions

Silicon detection is a mature technology for registering the passage of charged particles. At the same time it continues to evolve toward increasing radiation tolerance as well as precision and adaptability. For these reasons it is likely to remain a critical element of detection of systems associated with extraterrestrial exploration. Silicon sensor leakage current and depletion voltage depend on the integrated fluence received by the sensor and on its thermal history during and after the irradiation process. For minimal assumptions on shielding and hence on the particle energy spectrum, and using published data on Martian ground temperature, we predict the leakage current density and the depletion voltage, as a function of time, of silicon sensors in transit to and deployed continuously on the Mars surface for a duration of up to 28 Earth-years, for several sensor geometries and a worst-case temperature scenario.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Research in particles and fields

The astrophysical aspects of cosmic and gamma rays and the radiation environment of the Earth and other planets investigated by means of energetic particle detector systems flown on spacecraft and balloons are discussed. The theory of particles and fields in space is also addressed with particular emphasis on models of Saturn's magnetic field.

Vogt, R. E.↗

Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons

In this paper, we describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including cross-connected TPC wires, space charge effects, electron attachment to impurities, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 2% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range. As an example, the proton selection efficiency is increased by 2% after detector calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of background electron emission in the LUX detector

Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of signals from electron emission processes in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper, we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. We characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying these electron backgrounds under different experimental conditions, we identified the possible mechanisms that may contribute to the electron emission. We report the observed electron event rate in LUX after background rejection, and discuss how such backgrounds can be further mitigated in ongoing and future xenon-based dark matter experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

The 3×1×1 m3 demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performance of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vertex-finding and reconstruction of contained two-track neutrino events in the MicroBooNE detector

In this work, we describe algorithms developed to isolate and accurately reconstruct two-track events that are contained within the MicroBooNE detector. This method is optimized to reconstruct two tracks of lengths longer than 5cm. This code has applications to searches for neutrino oscillations and measurements of cross sections using quasi-elastic-like charged current events. The algorithms we discuss will be applicable to all detectors running in Fermilab's Short Baseline Neutrino program (SBN), and to any future liquid argon time projection chamber (LArTPC) experiment with beam energies ~ 1 GeV. The algorithms are publicly available on a GITHUB repository. This reconstruction offers a complementary and independent alternative to the Pandora reconstruction package currently in use in LArTPC experiments, and provides similar reconstruction performance for two-track events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗