At least 163 records · Page 9

Flexible Charging to Unify the Grid and Transportation Sectors for EVs at Scale (FUSE)

Electric vehicle (EV) adoption will expand beyond light-duty vehicles charging at lower-power public locations and family residences to include medium- and heavy-duty applications with more powerful charging at public stations and private depots. The Vehicle Grid Integration (VGI) and Smart Charge Management (SCM) pillar in EVs@Scale supports multiple projects. The FUSE project is developing and evaluating enabling technologies, charging solutions, and infrastructure design approaches to investigate the intricacies and potential benefits of vehicle grid integration and the application of smart charge management to charging of electric vehicles at scale. This presentation summarizes the findings of this research in 2024.

ADVANCED PROPULSION SYSTEMS↗

Beyond Energy Efficiency: A clustering approach to embed demand flexibility into building energy benchmarking

The intermittency of carbon-free renewables and the demand changes associated with the widespread push for electrifying the transportation and building sectors provides an opportunity for buildings to go beyond energy efficiency and push towards providing demand flexibility to the electricity grid. The duality of energy efficiency and demand flexibility is necessary for success in a sustainable and reliable energy transition. Current building energy benchmarking models are limited in their ability to integrate concepts of demand flexibility and/or utilize granular smart meter data. Thus, current benchmarking methods are focused annual energy usage and fail to incorporate how the time of use of energy consumption impacts emissions in a quickly changing energy grid. Without a more comprehensive view of energy usage and associated real-time emissions, current benchmarking methods are unlikely to realize the full decarbonization potential of buildings. New emerging data streams provide an opportunity to develop a new generation of benchmarking energy models that embed dimensions of energy efficiency, grid interactivity, and demand flexibility into their analysis. In this paper, we propose a four-step method for embedding grid interactivity and demand flexibility into building benchmarking models that utilizes emerging building and time-series electricity data streams. We first engineer features to produce a mix-type dataset that encompasses many attributes of grid-interactive and efficient buildings, and then we apply K-medoids using Gower's Distance to produce peer-group clusters. We apply the method to a case study of 306 primary and secondary schools in southern California, USA. The results show that the method effectively clusters buildings by attributes of demand flexibility and energy efficiency. The clustering results reveal patterns in inefficient building operations and demand inflexibility at the building peer group level. In conclusion, the interpretation of clusters can serve as an integrated energy efficiency and demand flexibility benchmarking model and inform performance-specific policy targeting for buildings that go beyond traditional efficiency measures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building energy efficiency and load flexibility optimization using phase change materials under futuristic grid scenario

This work investigates the energy savings and load flexibility capacity of phase change material (PCM) integrated into building envelope under a future energy generation scenario, where 80% of the energy load comes from renewable sources. Using community-scale modeling, we first determine the net thermal storage required to fully manage the demand variability at a utility grid, and then using whole-building simulations we optimize operating parameters - such as PCM thickness, latent heat, interior setpoint profile, PCM distribution, and heat transfer coefficient - to determine the optimal conditions required for maximum energy reduction and load flexibility without compromising occupants' thermal comfort. The optimal PCM-integrated envelope proposed in this study can provide annual load flexibility up to 33.6% and annual energy savings up to 10.8% in a lightweight residential building located in Baltimore, MD. This study is relevant given the increasing contributions of renewable energy in the total energy generation mix, leading to a significant time-imbalance between peak energy demand and peak energy production. While thermal energy storage using PCM is a recognized technique, there is no known prior study dedicated to examining the thermal performance of PCM-integrated envelope under future energy generation scenarios. This study bridges the research gap by investigating a practical way to implement PCMs in the buildings and maximize the energy efficiency as well as load flexibility related benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal electric-distribution-grid planning considering the demand-side flexibility of thermal building systems for a test case in Singapore

The planning of district-scale electric grids, i.e., distribution grids, has traditionally relied on finding the most cost-effective design such that they are able to supply the peak loads in a district. With the advent of electric demand side flexibility (DSF), there is the opportunity to reshape peak loads such that the investment cost of the electric grid decreases in exchange for a minor increase in the operation cost. This paper formulates an optimal planning approach for the electric grid at the district scale, which incorporates the DSF from thermal building systems, e.g., heating ventilation and air-conditioning (HVAC) systems. The problem is formulated as a mixed-integer linear program (MILP) and aims at minimizing the investment cost for the grid along with the operation cost of the flexible loads. This is subjected to the fixed electricity demand and thermal comfort constraints of building occupants. To this end, linear models for the thermal comfort in the buildings and the power flow in electric grid are considered. The approach is tested on a district planning test case based in Singapore, where the results show up to 30.9 % reductions in investment cost and up to 3.7 % reduction in total annualized cost. Urban planning authorities, developers and utility companies can all benefit from the presented approach to make optimized investment decisions. For building operators, the results point to the need of adopting their control systems for DSF.

Troitzsch, Sebastian↗

Impact of Nuclear Power Plant Energy Storage on Grid Reliability and Generation Costs with Variable Power Generation

This report examines the impact of combining integrated energy systems (IES), specifically hydrogen-based energy-storage systems, with nuclear power plants (NPPs) on grid reliability and generation flexibility in scenarios with substantial variable-power generation from solar energy. The analysis focuses on the challenges and solutions associated with high-levels of solar energy penetration, highlighting the role of advanced energy-storage solutions and flexible-generation technologies in enhancing grid stability and reliability.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

The Role of Hydropower in the Next-Generation Grid

Hydropower can provide a low-carbon source of energy, capacity, and flexibility to the grid. The National Renewable Energy Laboratory's (NREL's) hydropower research covers multiple aspects of grid integration, including hydropower's role in grid planning, operations modeling, and reliability and resilience research.

grid integration↗

The Role of Hydropower Flexibility in Integrating Renewables in a Low-Carbon Grid

In this study, we looked at the role of hydropower flexibility in variable renewable energy (VRE) integration. Our focus was on facilities that have at least ten hours of storage, i.e., plants that are "dispatchable" and have capacity values similar to that of fossil-fired generation. For our modeling framework, we used NREL's Mid-Case/95% Carbon Reduction by 2035 standard scenario as our foundation. This zonal model is representative of the buildout of a near-zero carbon policy grid in an otherwise "business-as-usual" policy and economic environment. We chose this scenario because it aligns well with the Administration's net-zero carbon grid by 2035 goal.

13 HYDRO ENERGY↗

Scalable Hybrid Classification-Regression Solution for High-Frequency Nonintrusive Load Monitoring

Residential buildings with the ability to monitor and control their net-load (sum of load and generation) can provide valuable flexibility to power grid operators. We present a novel multiclass nonintrusive load monitoring (NILM) approach that enables effective net-load monitoring capabilities at high-frequency with minimal additional equipment and cost. The proposed machine learning based solution provides accurate multiclass state predictions while operating at a faster timescale (able to provide a prediction for each 60- Hz ac cycle used in US power grid) without relying on event-detection techniques. We also introduce an innovative hybrid classification-regression method that allows for the prediction of not only load on/off states but also individual load operating power levels. A test bed with eight residential appliances is used for validating the NILM approach. Results show that the overall method has high accuracy, good scaling and generalization properties.

feature extraction↗

Copper Electrode on Flexible Substrate by Intense Pulsed Light Sintering of Microsized Copper Particles

Metal electrodes deposited in a grid pattern onto flexible polymer substrates have been shown to be a viable alternative to replace indium tin oxide (ITO) as the transparent anode for organic photovoltaics. copper may be a better alternative in terms of cost and stability for large area low-cost solar modules, specifically on roll-to-roll platforms. These customized electrode patterns can be fabricated from copper nanoparticles through various printing techniques applicable to solution phase processing. The Intense Pulsed Light (IPL) technique has been used to sinter copper nanoparticles (~100nm) to fabricate conductive copper electrodes on flexible polymer substrates. However, compared to nanosized (~100 nm) copper particles, microsized (~2 um) copper is much cheaper. In this work, microsized (~2 um) copper is used to produce high conductive copper inks. The conductivity of the print can be adjusted through the use of surfactant. IPL sintering was optimized to obtain high conductivity copper films. In conclusion, several microscopic and electrical spectroscopic characterization techniques such as scanning electron microscopy (SEM), x-ray diffraction (XRD), 4-point probe resistivity measurements were employed to characterize the copper electrodes.

14 SOLAR ENERGY↗

Hierarchical Model-Free Transactive Control of Residential Building Loads: An Actual Deployment

The transformation of electricity systems into more sustainable configurations brought some new challenges. The uncertain, intermittent, and variable nature of renewable energy sources require a significant amount of load demand flexibility, in which grid-interactive buildings (GEBs) are important flexible assets for electricity systems. In this regard, many demand response (DR) tools have been developed to harness this demand flexibility. However, such tools are mostly simulation-based or deal with a single load, which may not be sufficient to demonstrate their effectiveness. Towards this end, this paper presents a real-world field implementation and testing of a hierarchical model-free transactive DR control approach on actual GEBs. The control implementation incorporates elements of virtual battery, game theory, and model-free control mechanisms. The proposed approach was tested using a total of five GEBs, each having three zones. The results show that the proposed approach can mostly achieve all intended objectives, including flexibility estimation, peak load reduction, power tracking, and controlling GEBs while maintaining occupants’ comfort.

Amasyali, Kadir↗

Modeling the Impact of Flexible CHP on the Future Electric Grid In California

Combined heat and power (CHP) systems provide electricity and process heat at more than 4,400 industrial and commercial facilities across the United States. Typically fueled with natural gas, a CHP system combines a prime mover (such as a reciprocating engine) with a generator and heat recovery equipment, allowing operation at very high efficiencies (65–85%). Traditionally, CHP systems have been configured to serve local electrical and thermal loads at the sites where they are deployed. Units are sized to ensure a high capacity factor for the equipment, and the electricity generated tends to be used on site. CHP units in the United States already generate over 12% of the nation’s electricity. However, CHP’s potential benefits could be much greater if power generated could be used beyond the site, because the analysis was performed under the assumption that sites could use all the thermal output. Analysis of a few key sectors confirmed that this assumption is valid (for more information, see Appendix E). Those benefits could include improved grid reliability and resilience, as well as lower-cost options for providing energy and other grid services. The potential benefits also align well with grid modernization objectives, as shown in Combined heat and power (CHP) systems provide electricity and process heat at more than 4,400 industrial and commercial facilities across the United States., and greater electrification of loads, driven by carbon reduction priorities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enabling Grid-Aware Market Participation of Aggregate Flexible Resources

Increasing integration of distributed energy resources (DERs) within distribution feeders provides unprecedented flexibility at the distribution-transmission interconnection. With the new FERC 2222 order, DER aggregations are allowed to participate in energy market. To enable market participation, these virtual power plants need to provide their generation cost curves. This paper proposes efficient optimization formulations and solution approaches for the characterization of hourly as well as multi-time-step generation cost curves for a distribution system with high penetration of DERs. Network and DER constraints are taken into account when deriving these cost curves, and they enable active distribution systems to bid into the electricity market. The problems of deriving linear and quadratic cost curves are formulated as robust optimization problems and tractable reformulation/solution algorithm are developed to facilitate efficient calculations. The proposed formulations and solution algorithm are validated on a realistic test feeder with high penetration of flexible resources.

aggregated distributed energy resources↗

Machine-Learning-Driven, Site-Specific Weather Forecasting for Grid-Interactive Efficient Buildings: Preprint

Emerging grid-interactive efficient buildings (GEBs) have great potential to provide much-needed demand flexibility to electric grids while fulfilling their own control targets by co-optimizing smart appliances, solar photovoltaics, electric vehicles, and energy storage at buildings. To enable the optimal operation of GEBs, site-specific weather information—such as temperature, solar irradiance, relative humidity, and wind speed—is crucial; however, this information is generally unavailable or expensive to obtain. This paper develops advanced machine learning methods to provide precise weather forecasts for individual building sites using readily available weather station data. Support vector regression and artificial neural networks have been employed to learn the spatiotemporal correlations between the weather conditions at nearby weather stations and the individual building site. The proposed site-specific weather forecasting methods have been validated using 1-year actual weather measurement data collected in the Denver metro area. Results show that the developed machine-learning-driven methods can accurately forecast the temperature at the target building site 1 hour ahead with mean absolute error less than 0.72°C and a 48% improvement over the persistence method. Site-specific weather forecasts will improve the understanding of the microclimate effect and its impact on building energy consumption. This information will drive efficiency upgrades and adjustments of building control strategies to improve energy savings and increase flexibility in building loads.

30 DIRECT ENERGY CONVERSION↗

The flexibility gap: Socioeconomic and geographical factors driving residential flexibility

Residential consumers are moving to the center of electricity systems and their flexibility is seen as a key resource to integrate renewable energy sources and support the grid. However, residential flexibility capacities are not homogeneous, as they depend on household appliances, comfort patterns, occupancy, and climate conditions. In this work, we calculate the technical flexibility capacities of 45 consumer types in mainland Spain, organised according to income and regional criteria. We show that flexibility gaps exist at both regional and socioeconomic (income) levels with flexibility differences of up to 10 times more capacity between the household groups from the lowest to the highest capacities. These geographical and socioeconomic gaps in flexibility can lead to distortions in national markets and have the potential to exclude citizens from the provision of flexibility services. Our results show in quantitative terms that a consumer-centered approach without considering correcting measures nor these gaps in drafting energy policies may lead to increasing inequality levels in the residential sector. Under an economic competitive paradigm, households with lower income levels or located in regions with lower flexibility potential may be excluded from the provision of flexibility to the detriment of households with larger potential, raising justice concerns in a flexibility-based energy transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geographically Distributed Co-Simulation for the Interplay of Integrated Energy Systems and Power Grid

The increased penetration of renewable generation induces unbalanced demand-supply on a power grid, while integrated energy systems (IES) can provide high part-load efficiency and high flexibility to support grid resilience. To study the transients and improve dynamic operability, it’s important to investigate the interplay between IES and power grid concurrently using real-time co-simulation approaches. In this presentation, we showed the previous co-simulation test between NETL and INL and discussed how this co-simulation can be beneficial for both IES and power grid research. In addition, we gave an overview about the SuperLab2.0 project, which was a federated national platform to address future power grid challenges. (Virtual presentation to the MILLENNIUM CLEAN and SUSTAINABLE POWER workshop 2025).

Co-simulation↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗