Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Heat Transfer and Fluid Mechanics Institute, Meeting, 25th, University of California, Davis, Calif., June 21-23, 1976, Proceedings

Major research advances in heat transfer and fluid dynamics are outlined, with particular reference to relevant energy problems. Of significant importance are such topics as synthetic fuels in combustion, turbulence models, combustion modeling, numerical methods for interacting boundary layers, and light-scattering diagnostics for gases. The discussion covers thermal convection, two-phase flow and boiling heat transfer, turbulent flows, combustion, and aerospace heat transfer problems. Other areas discussed include compressible flows, fluid mechanics and drag, and heat exchangers. Featured topics comprise heat and salt transfer in double-diffusive systems, limits of boiling heat transfer in a liquid-filled enclosure, investigation of buoyancy-induced flow stratification in a cylindrical plenum, and digital algorithms for dynamic analysis of a heat exchanger. Individual items are announced in this issue.

Mckillop, A. A.↗

A Summary of Recent SBIR and STTR Projects in Support of Cryogenic Fluid Management Modeling

Over the last five years, NASA has invested in development of sub-models to improve the current capabilities of Computational Fluid Dynamics (CFD) codes utilized for cryogenic fluid management (CFM) predictions. The goal is for the submodels to be modular so that they can easily be implemented into NASA’s CFD codes such as ANSYS Fluent, Siemens STAR-CCM+, and Streamline Numerics Loci-Stream. These technologies are being developed through Small Business Innovative Research (SBIR) and Small Business Technology Transfer (STTR) contracts under the CFM subtopic solicitation and funded by the CFM Portfolio Project. All contracts presented include cryogenic experiments to enable model validation. A sub-grid boiling model has been developed by Combustion Research and Flow Technology Inc. and Massachusetts Institute of Technology for cryogenic line chilldown predictions and has completed Phase III. A spray chill-and-fill model for cryogenic tankage is being developed by Combustion Research and Flow Technology Inc. and University of Connecticut and is currently in Phase II. Last, film condensation modeling to support cryogenic liquefaction was progressed through a Phase I contract with Combustion Research and Flow Technology Inc. and University of Connecticut. A summary of accomplishments for each contract is presented.

cryogenics↗

Numerical Predictions of the Flow and Heat Transfer Characteristics in the Film Boiling Regime During Tube Quenching

Cryogenic fluid management plays a major role in refueling of spacecrafts while in space for NASA’s future human space exploration missions. Due to the low boiling points of cryogens, storage, transport and handling of these fluids becomes difficult and may result in inefficient operation of the space propulsion systems. For refueling applications in space, the cryogenic fluids have to be transported across different locations and hence, the transfer of cryogenic fluids through pipes become critical. The cryogenic chill-down process is characterized by different regimes of flow boiling, viz., film boiling, transition boiling and nucleate boiling. The prediction of these regimes in a single CFD framework available in the literature is challenging and the present work attempts to address this challenge by initially modeling the film boiling regime accurately and to incorporate an user-defined function for transition and nucleate boiling at a later stage. Hence, the aim of the present work is to numerically model and validate the film boiling regime of the chilldown curve for liquid nitrogen experiments available in the literature. The validations are carried out at different inlet mass fluxes to have a robust simulation methodology. A dispersed mixture model is used to predict the vapor-liquid interface dynamics with the phase change phenomena modeled using the Lee model.

line chilldown↗

Transport processes in boiling and two-phase systems, including near-critical fluids

Aspects of pool boiling are considered, taking into account nucleate boiling, the nucleate boiling mechanism, film boiling, and the transition between nucleate and film boiling. The characteristics of two-phase flow are also investigated, giving attention to two-phase flow parameters and equations, the flow pattern in two-phase flow, the pressure drop in two-phase flow, heat transfer in two-phase flow, two-phase flow dynamics, the boiling crisis in two-phase flow, the critical flow rate, the propagation of the pressure pulse and the sonic velocity in two-phase media, instrumentation for two-phase flow, and geometry and field effects on boiling and two-phase flow. Near-critical fluids are also considered.

Hsu, Y.-Y.↗

Technology of forced flow and once-through boiling: A survey

Representative boiling heat transfer and pressure drop information obtained primarily from past NASA and AEC programs is presented which is applicable to forced flow and once-through boiler systems. The forced convection boiler has a number of advantages: little possibility of flow mal-distribution; heat transfer characteristics are usually consistent; and conductances are predictable, so that higher heat fluxes may be employed with safety (which leads to more compact, lighter weight equipment). It was found that in gas-fired systems particularly, the controlling heat transfer resistance may be on the hot side, so that increased fluxes would require extended surfaces. If in a power generation system the working fluid is very expensive, a forced flow boiler can be designed especially for small holdup volume. If the fluid is temperature sensitive, the boiling side wall temperatures can be tailored to maintain maximum heat transfer rates without overheating the fluid. The forced flow and once-through configurations may be the only type which can satisfy a specific need (such as the automotive Rankine cycle power plant design having a very short time-response boiler).

Poppendieck, H. F.↗

Combined buoyancy and flow direction effects on saturated boiling critical heat flux in liquid nitrogen

Buoyancy effects on the critical heat flux and general data trends for a liquid nitrogen internal flow system were determined by comparison of upflow and downflow data under identical test conditions. The test section had a 1.28 cm diameter flow passage and a 30.5 cm heated length which was subjected to uniform heat fluxes through resistance heating. Test conditions covered a range of pressures from 3.4 to 10.2 atm, inlet velocities from 0.23 to 3.51 m/sec, with the liquid nitrogen temperature at saturated inlet conditions. Data comparisons showed that the critical heat flux for downflow could be up to 36 percent lower than for upflow. A nonmonotonic relationship between the critical heat flux and velocity was determined for upflow but not for downflow. A limiting inlet velocity of 4.12 m/sec was determined to be the minimum velocity required to completely suppress the influence of buoyancy on the critical heat flux for this saturated inlet flow system. A correlation of this limiting fluid velocity is presented that was developed from previously published subcooled liquid nitrogen data and the saturated data of this investigation.

Papell, S. S.↗

Simulations of Cryogenic Line Chilldown with Advanced Sub-Grid Wall Boiling Models

A meso-scale model developed at MIT [2][11] for boiling processes in water was adapted for cryogens and demonstrated for chilldown of propellant transfer lines in both liquid nitrogen and hydrogen. The sub-grid boiling model accurately captures the contributions to heat transfer from the generation of bubble nuclei, growth, and interaction of the bubbles in the microlayer as well as quenching of the boiling surface following bubble departure. It was adapted for cryogenic fluids using thermodynamic scaling concepts taking into account non-dimensional pressures and temperatures that are scaled by the corresponding critical values for the fluid. The boiling model was demonstrated for line chilldown in liquid nitrogen (Darr et al. [6]). The predicted wall temperature at which quenching occurs was close to the test data while the slope of the temperature curve after quenching is initiated, showing a steeper variation than the test data. Simulations were also performed for liquid hydrogen by simulating experiments of Hartwig et al. [7]. Chilldown times in liquid hydrogen are much more rapid due to higher heat transfer in the film boiling regime and accounting for the higher turbulence levels were found to be important. Furthermore, at the much lower fluid temperatures in liquid hydrogen flows, accounting for the variable thermal properties of the solid material is critical and has a dramatic impact on the quench times. The need for additional studies to better understand the evolution of the quench front in liquid hydrogen was noted.

Computational Fluid Dynamics↗

Simulations of Cryogenic Line Chilldown with Advanced Sub-Grid Wall Boiling Models

A meso-scale model developed at MIT [2][11] for boiling processes in water was adapted for cryogens and demonstrated for chilldown of propellant transfer lines in both liquid nitrogen and hydrogen. The sub-grid boiling model accurately captures the contributions to heat transfer from the generation of bubble nuclei, growth, and interaction of the bubbles in the microlayer as well as quenching of the boiling surface following bubble departure. It was adapted for cryogenic fluids using thermodynamic scaling concepts taking into account non-dimensional pressures and temperatures that are scaled by the corresponding critical values for the fluid. The boiling model was demonstrated for line chilldown in liquid nitrogen (Darr et al. [6]). The predicted wall temperature at which quenching occurs was close to the test data while the slope of the temperature curve after quenching is initiated, showing a steeper variation than the test data. Simulations were also performed for liquid hydrogen by simulating experiments of Hartwig et al. [7]. Chilldown times in liquid hydrogen are much more rapid due to higher heat transfer in the film boiling regime and accounting for the higher turbulence levels were found to be important. Furthermore, at the much lower fluid temperatures in liquid hydrogen flows, accounting for the variable thermal properties of the solid material is critical and has a dramatic impact on the quench times. The need for additional studies to better understand the evolution of the quench front in liquid hydrogen was noted.

Computational Fluid Dynamics↗

Boiling incipience and convective boiling of neon and nitrogen

Forced convection and subcooled boiling heat transfer data for liquid nitrogen and liquid neon were obtained in support of a design study for a 30 tesla cryomagnet cooled by forced convection of liquid neon. This design precludes nucleate boiling in the flow channels as they are too small to handle vapor flow. Consequently, it was necessary to determine boiling incipience under the operating conditions of the magnet system. The cryogen data obtained over a range of system pressures, fluid flow rates, and applied heat fluxes were used to develop correlations for predicting boiling incipience and convective boiling heat transfer coefficients in uniformly heated flow channels. The accuracy of the correlating equations was then evaluated. A technique was also developed to calculate the position of boiling incipience in a uniformly heated flow channel. Comparisons made with the experimental data showed a prediction accuracy of plus or minus 15 percent

Papell, S. S.↗