Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow Improvers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Application of computational fluid dynamics and laminar flow technology for improved performance and sonic boom reduction

A discussion is given of the many factors that affect sonic booms with particular emphasis on the application and development of improved computational fluid dynamics (CFD) codes. The benefits that accrue from interference (induced) lift, distributing lift using canard configurations, the use of wings with dihedral or anhedral and hybrid laminar flow control for drag reduction are detailed. The application of the most advanced codes to a wider variety of configurations along with improved ray-tracing codes to arrive at more accurate and, hopefully, lower sonic booms is advocated. Finally, it is speculated that when all of the latest technology is applied to the design of a supersonic transport it will be found environmentally acceptable.

Bobbitt, Percy J.↗

Improvements to a Flow Sensor for Liquid Bismuth-Fed Hall Thrusters

Recently, there has been significant interest in using bismuth metal as a propellant in Hall Thrusters [1, 2]. Bismuth offers some considerable cost, weight, and space savings over the traditional propellant--xenon. Quantifying the performance of liquid metal-fed Hall thrusters requires a very precise measure of the low propellant flow rates [1, 2]. The low flow rates (~10 mg/sec) and the temperature at which free flowing liquid bismuth exists (above 300 C) preclude the use of off-the-shelf flow sensing equipment [3]. Therefore a new type of sensor is required. The hotspot bismuth flow sensor, described in Refs. [1-5] is designed to perform a flow rate measurement by measuring the velocity at which a thermal feature moves through a flow chamber. The mass flow rate can be determined from the time of flight of the thermal peak, [4, 5]. Previous research and testing has been concerned mainly with the generation of the thermal peak and it's subsequent detection. In this paper, we present design improvements to the sensor concept; and the results of testing conducted to verify the functionality of these improvements. A ceramic material is required for the sensor body (see Fig. 1), which must allow for active heating of the bismuth flow channel to keep the propellant in a liquid state. The material must be compatible with bismuth and must be bonded to conductive elements to allow for conduction of current into the liquid metal and measurement of the temperature in the flow. The new sensor requires fabrication techniques that will allow for a very small diameter flow chamber, which is required to produce useful measurements. Testing of various materials has revealed several that are potentially compatible with liquid bismuth. Of primary concern in the fabrication and testing of a robust, working prototype, is the compatibility of the selected materials with one another. Specifically, the thermal expansion rates of the materials relative to the ceramic body cannot expand so much as to cause cracks in the body or cause the bond between parts to delaminate. Those parts that will carry the current pulse must be electrically conductive while the sensor body must be an electrical insulator. Generally, the material choices as well as the sensor design must aid to preserve the integrity of the thermal feature to obtain accurate measurements. The present aim is to also incorporate, into the sensor body, an active heating arrangement based on ceramic heater technology similar to that used in semiconductor manufacturing.

Bonds, Kevin↗

Environmental Data Flow Six Sigma Process Improvement Savings Overview

An overview of the Environmental Data Flow Six Sigma improvement project covers LANL’s environmental data processing following receipt from the analytical laboratories. The Six Sigma project identified thirty-three process improvements, many of which focused on cutting costs or reducing the time it took to deliver data to clients.

54 ENVIRONMENTAL SCIENCES↗

Turbulent transport modelling of separating and reattaching shear flows

The improvement of capabilities for computer simulation of turbulent recirculating flows was investigated. Attention has been limited to two dimensional flows and principally to statistically stationary motion. Improvement of turbulence modeling explored the treatment of the near wall sublayer and of the exterior fully turbulent region, working within the framework of turbulence closures requiring the solution of transport equations for the turbulence energy and its dissipation rate. The work on the numerical procedure, based on the Gosman-Pun program TEACH, addressed the problems of incorporating the turbulence model as well as the extension to time dependent flows, the incorporation of a third order approximation of convective transport, and the treatment of non-orthogonal boundaries.

Launder, B. E.↗

Improved particle-flow event reconstruction with scalable neural networks for current and future particle detectors

Abstract Efficient and accurate algorithms are necessary to reconstruct particles in the highly granular detectors anticipated at the High-Luminosity Large Hadron Collider and the Future Circular Collider. We study scalable machine learning models for event reconstruction in electron-positron collisions based on a full detector simulation. Particle-flow reconstruction can be formulated as a supervised learning task using tracks and calorimeter clusters. We compare a graph neural network and kernel-based transformer and demonstrate that we can avoid quadratic operations while achieving realistic reconstruction. We show that hyperparameter tuning significantly improves the performance of the models. The best graph neural network model shows improvement in the jet transverse momentum resolution by up to 50% compared to the rule-based algorithm. The resulting model is portable across Nvidia, AMD and Habana hardware. Accurate and fast machine-learning based reconstruction can significantly improve future measurements at colliders.

Physics↗

Improved Depiction Of Measured Flow Fields

Measurement-monitor-surface (MMS) procedure makes possible to apply, to measurements of flow fields, interactive computer-graphical techniques processing simulated flow-field data into mach-number contours and other pictures of selected aspects of flows. Developed to satisfy need for improved method of analyzing flow data obtained by two-dimensional laser anemometry in low-aspect-ratio, transonic, axial-flow fan rotor in turbomachine.

Miles, Jeffrey H.↗

Stereolithographic Fabrication of a Flow Cell For Improved Neurochemical Sensor Testing

The human brain remains a mystery to researchers. Scientists at Lawrence Livermore National Laboratory (LLNL) have developed highly sensitive and flexible multimodal multielectrode arrays (MEAs) with the potential to be both powerful diagnostic and therapeutic tools when dealing with neurological ailments such as Alzheimers, Parkinson’s, Post Traumatic Stress Disorder, and Traumatic Brain Injuries. These MEAs include biosensors in addition to electrodes for electrical stimulation and recording. The transition from the traditional rigid neural probes to the flexible MEAs has led LLNL researchers on the search for alternative testing and characterization methods for flexible devices in vitro. The rigid devices have been shown to be more abrasive and damaging to the brain when implanted, but due to their rigidity – are more robust and resilient to noise artifacts in in vitro testing. The flexible MEAs, similar in size and flexibility to a human hair, cause much less damage in the brain but have had a difficult time maintaining their integrity and collecting data without high-levels of noise due to the formation of inertial eddies (due to increased turbulent flow) moving the flexible MEA during in vitro testing. The goal of this project was to design a fluidic cell to allow for a more constant electrochemical testing & characterization of biosensors on these flexible MEAs. Design and fabrication of the fluidic cell was through the use of CAD software and a stereolithography printer using clear photopolymer resin (appropriate for biomedical use and quality resolution). Flow cells facilitate analyte delivery to biosensor surfaces in a more constant and controlled fashion, allowing for –in this case –a better electrodeposition of thin-film Platinum-Iridium (Pt-Ir) on MEAs of 16 Platinum disc electrodes 50µm in diameter. Platinum-Iridium alloy electrodes have been widely used in biomedical and industrial applications. Iridium adds mechanical stiffness to platinum. PtIr is a FDA approved electrode material for human implantable devices.

36 MATERIALS SCIENCE↗

Methods for improved resolution of flow electrophoresis cells

First method involves remote adjusting of zeta potential. Second approach sandwiches two conducting metal plates between opposite cell walls and thin insulating layer. Third method forces buffer to flow in direction opposite particle streams.

Mccreight, L. R.↗

Improved axisymmetric potential flow computer program

Basic method of calculating potential flow has been refined to increase accuracy of results and to reduce computational time. Program calculates low speed flows about or within bodies of axially symmetric shape. Solid body, inlet, and purely internal flow problems can be solved.

Hess, J. L.↗

Vortical flow management for improved configuration aerodynamics: Recent experiences

Recent progress in vortex-control applications for alleviating the adverse consequences of three dimensional separation and vortical interactions on slender body/swept wing configurations is reported. Examples include helical separation trip to alleviate the side force due to forebody vortex asymmetry; hinged strakes to avoid vortex breakdown effects; compartmentation of swept leading edge separation to delay the pitch-up instability; under wing vortex trip and vortex trip and vortex flaps for drag reduction at high lift; and an apex-flap trimmer to fully utilize the lift capability of trailing-edge flaps for take off and landing of delta wings. Experimental results on generic wind-tunnel models are presented to illustrate the vortex-management concepts involved and to indicate their potential for enhancing the subsonic aerodynamics of supersonic-cruise type vehicles.

Rao, D. M.↗

Digital image velocimetry

Digital image velocimetry is proposed for the measurement of the instantaneous velocity fields of time dependent flows. This technique improves the flow measurement by eliminating some of the restrictions on existing optical methods (i.e., laser speckle velocimetry and particle image velocimetry). Among these restrictions are the limited dynamic range of the velocity measurement, directional ambiguity of the velocity vector, and the difficulty of a real-time capability. The present technique greatly enhances the dynamic range of the velocity measurement and unequivocally determines the direction of the velocity vector.

Cho, Y.-C.↗

Improved visualization of flow field measurements

A capability was developed that makes it possible to apply to measured flow field data the visualization tools developed to display numerical solutions for computational fluid dynamic problems. The measurement monitor surface (MMS) procedure was applied to the analysis of flow field measurements within a low aspect ratio transonic axial flow fan rotor obtained with 2-D laser anemometry. The procedure generates input for the visualization tools developed to display numerical solutions for computational fluid dynamics problems. The relative Mach number contour plots obtained by this method resemble the conventional contour plots obtained by more traditional methods. The results show that the MMS procedure can be used to generate input for the multidimensional processing and analysis tools developed for data from numerical flow field simulations. They show that an experimenter can apply the MMS procedure to his data and then use an interactive graphics program to display scalar quantities like the Mach number by profiles, carpet plots, contour lines, and surfaces using various colors. Also, flow directionality can be shown by display of vector fields and particle traces.

Miles, Jeffrey Hilton↗

Improved visualization of flow field measurements

A capability is proposed that makes it feasible to apply to measured flow field data the visualization tools developed to display numerical solutions for computational fluid dynamic problems. The measurement monitor surface (MMS) methodology was used for the analysis of flow field measurements within a low-aspect-ratio transonic axial-flow fan rotor acquired with two-dimensional laser anemometry. It is shown that the MMS method may be utilized to generate input for the multidimensional processing and analytical tools developed for numerical flow field simulation data. Thus an experimenter utilizing an interactive graphics program could illustrate scalar quantities such as Mach number by profiles, contour lines, carpet plots, and surfaces employing various color intensities. Also, flow directionality can be shown by the display of vector fields and particle traces.

Miles, Jeffrey Hilton↗

On improvement of air flow in wind tunnels

The most important aerodynamical qualities that should be aimed at in wind tunnel design, are as follows: 1) constant and parallel direction of flow; 2) uniform velocity across all sections; 3) absence of turbulent motion; 4) constant velocity of flow. The above-mentioned qualities are all realized in a high degree in the Gottingen type of wind tunnel, with a parallel portion before the working section, the cross section of which is steadily reduced. It is shown in what follows, that the system can be applied to other wind tunnels, such as the N.P.L. or Eiffel type.

JOURNAL↗

Improved in-flow acoustic sensor

An acoustic sensor for measuring acoustic waves contained in fluid flowing over the sensor is described. The acoustic sensor reduces any unwanted self-noise associated with the flowing fluid by providing a nose cone having proper aerodynamic properties and by positioning the diaphragm of a microphone of the sensor at a location where any unwanted noise is at a relatively low level. The nose cone has a rounded, blunt or even sharp tip, neither of which creates any major disturbances in the flowing fluid which it intercepts.

Allen, Christopher S.↗

Development and application of a 3D Cartesian grid Euler method

This report describes recent progress in the development and application of 3D Cartesian grid generation and Euler flow solution techniques. Improvements to flow field grid generation algorithms, geometry representations, and geometry refinement criteria are presented, including details of a procedure for correctly identifying and resolving extremely thin surface features. An initial implementation of automatic flow field refinement is also presented. Results for several 3D multi-component configurations are provided and discussed.

Melton, John E.↗

Modernization and Activation of the NASA Ames 11- by 11-Foot Transonic Wind Tunnel

The Unitary Plan Wind Tunnel (UPWT) was modernized to improve performance, capability, productivity, and reliability. Automation systems were installed in all three UPWT tunnel legs and the Auxiliaries facility. Major improvements were made to the four control rooms, model support systems, main drive motors, and main drive speed control. Pressure vessel repairs and refurbishment to the electrical distribution system were also completed. Significant changes were made to improve test section flow quality in the 11-by 11-Foot Transonic leg. After the completion of the construction phase of the project, acceptance and checkout testing was performed to demonstrate the capabilities of the modernized facility. A pneumatic test of the tunnel circuit was performed to verify the structural integrity of the pressure vessel before wind-on operations. Test section turbulence, flow angularity, and acoustic parameters were measured throughout the tunnel envelope to determine the effects of the tunnel flow quality improvements. The new control system processes were thoroughly checked during wind-off and wind-on operations. Manual subsystem modes and automated supervisory modes of tunnel operation were validated. The aerodynamic and structural performance of both the new composite compressor rotor blades and the old aluminum rotor blades was measured. The entire subsonic and supersonic envelope of the 11-by 11-Foot Transonic leg was defined up to the maximum total pressure.

Kmak, Frank J.↗