Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Stable Laser-Driven Electron Beams from a Steady-State-Flow Gas Cell

Quasi-monoenergetic, laser-driven electron beams of up to {approx}200 MeV in energy have been generated from steady-state-flow gas cells [1]. These beams are emitted within a low-divergence cone of 2.1{+-}0.5 mrad FWHM and feature unparalleled shot-to-shot stability in energy (2.5% rms), pointing direction (1.4 mrad rms) and charge (16% rms) owing to a highly reproducible plasma-density profile within the laser-plasma-interaction volume. Laser-wakefield acceleration (LWFA) in gas cells of this type constitutes a simple and reliable source of relativistic electrons with well defined properties, which should allow for applications such as the production of extreme-ultraviolet undulator radiation in the near future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Versatile plug flow catalytic cell for in situ transmission/fluorescence x-ray absorption fine structure measurements

A novel flow-through catalytic cell has been developed for in situ x-ray absorption spectroscopy (XAS) experiments on heterogeneous catalysts under working conditions and in the presence of a liquid and a gas phase. The apparatus allows to carry out XAS measurements in both the transmission and fluorescence modes, at moderate temperature (from RT to 50-80 Degree-Sign C) and low-medium gas pressure (up to 7-8 bars). The materials employed are compatible with several chemicals such as those involved in the direct synthesis of hydrogen peroxide (O{sub 2}, H{sub 2}, H{sub 2}O{sub 2}, methanol). The versatile design of the cell allows to fit it to different experimental setups in synchrotron radiation beamlines. It was used successfully for the first time to test nanostructured Pd catalysts during the direct synthesis of hydrogen peroxide (H{sub 2}O{sub 2}) in methanol solution from dihydrogen and dioxygen.

36 MATERIALS SCIENCE↗

Experimental and numerical investigation of supersonic flow through a square duct

Steady, developing, adiabatic supersonic flow in a square duct is investigated for an inlet Mach number of 3.91 and a unit Reynolds number of 1.8 x 10 to the 6th/m. The numerical results for laminar flow show that two secondary flow cells develop in the near vicinity of the corner which are centered about the corner bisector and distort the primary flow in this region. For turbulent flow, the experimental results indicate that two secondary flow cells also develop about the corner bisector, but are directed in an opposite sense to that observed for the laminar case. Numerical results based on the Baldwin-Lomax model show that this model is incapable of predicting turbulence-generated secondary flow cells. For a suitable choice of constants, the Gessner-Emery model is able to predict the strength of these cells, but is deficient with respect to predicting their positions in the flow and their distorting influence on the primary flow. These observations are based on comparisons made in this paper between predicted and measured total pressure contours, cross flow velocity profiles, and local wall shear stress distributions.

Davis, D. O.↗

Overview of On-Line Optical Measurements at High Pressure for Flue Gases, Particulates and Acid-dew Point of Pressurized Oxy-Combustion

Optical flow cells are critical measurement interfaces, yet sampling under harsh conditions — high pressure, high temperature, particles, moisture, or corrosive gases — makes it difficult to maintain optical quality without perturbing the measurement. To address this challenge, a new flow cell was developed using a laminar coaxial flow field that separates the purge and sample flows. A dedicated test system was built to evaluate particle size distribution (PSD) measurements using a Malvern Panalytical Insitec analyzer. Results demonstrated that the sample flow alone defines the measurement zone, while the purge flow effectively shields the optical windows from deposition, eliminating sampling bias. The flow cell enables reliable PSD measurement under high pressure and temperature in moist, corrosive environments. As a key demonstration, the instrument was successfully deployed for on-line PSD measurement of flue gas from a 100 kWth pressurized oxy-coal combustor at 15 bara.

Cheng, Mao↗

Intermediate-Scale Laboratory Experiments of Subsurface Flow and Transport Resulting from Tank Leaks

Washington River Protection Solutions contracted with Pacific Northwest National Laboratory to conduct laboratory experiments and supporting numerical simulations to improve the understanding of water flow and contaminant transport in the subsurface between waste tanks and ancillary facilities at Waste Management Area C. The work scope included two separate sets of experiments: • Small flow cell experiments to investigate the occurrence of potential unstable fingering resulting from leaks and the limitations of the STOMP (Subsurface Transport Over Multiple Phases) simulator to predict flow patterns and solute transport behavior under these conditions. Unstable infiltration may, under certain conditions, create vertically elongated fingers potentially transporting contaminants rapidly through the unsaturated zone to groundwater. The types of leak that may create deeply penetrating fingers include slow release, long duration leaks in relatively permeable porous media. Such leaks may have occurred below waste tanks at the Hanford Site. • Large flow experiments to investigate the behavior of two types of tank leaks in a simple layered system mimicking the Waste Management Area C. The investigated leaks include a relatively large leak with a short duration from a tank and a long duration leak with a relatively small leakage rate from a cascade line. The main objective of the small flow cell experiments was to test the ability of the numerical simulator STOMP to predict overall plume behavior and arrival times of conservative tracers in two different porous media for a relatively large range in injection rates. The large flow cell experiments were conducted to visualize flow and transport from short duration, fast leak and from long duration, slow leak scenarios.

contaminant transport↗

Medical and Scientific Evaluations aboard the KC-135. Microgravity-Compatible Flow Cytometer

A spaceflight-compatible flow cytometer would be useful for the diagnosis of astronaut illness during long duration spaceflight and for conducting in-flight research to evaluate the effects of microgravity on human physiology. Until recently, the primary limitations preventing the development of a spaceflight compatible flow cytometer have been largely mechanical. Standard commercially available flow cytometers are large, complex instruments that use high-energy lasers and require significant training to operate. Standard flow cytometers function by suspending the particles to be analyzed inside a sheath fluid for analysis. This requires the presence of several liters of sheath fluid for operation, and generates a corresponding amount of liquid hazardous waste. The particles are then passed through a flow cell which uses the fluid mechanical property of hydrodynamic focusing to place the cells in single-file (laminar flow) as they pass through a laser beam for scanning and evaluation. Many spaceflight experiments have demonstrated that fluid physics is dramatically altered in microgravity (MSF [Manned Space Flight] Fluid Physics Data Sheet-August 1997) and previous studies have shown that sheath-fluid based hydrodynamic focusing may also be altered during microgravity (Crucian et al, 2000). For these reasons it is likely that any spaceflight compatible design for a flow cytometer would abandon the sheath fluid requirement. The elimination of sheath fluid would remove both the problems of weight associated with large volumes of liquids as well as the large volume of liquid waste generated. It would also create the need for a method to create laminar particle flow distinct from the standard sheath-fluid based method. The spaceflight prototype instrument is based on a recently developed commercial flow cytometer possessing a novel flow cell design that creates single-particle laser scanning and evaluation without the need for sheath-fluid based hydrodynamic focusing. This instrument also possesses a number of design advances that make it conditionally microgravity compatible: it is highly miniaturized and lightweight, uses a low energy diode laser, has a small number of moving parts, does not use sheath fluid and does not generate significant liquid waste. Although possessing certain limitations, the commercial cytometer functions operationally like a standard bench top laboratory flow cytometer, aspirating liquid particle samples and generating histogram or dot-plot data in standard FCS file format. In its current configuration however, the cytometer is limited to three parameter/two-color capability (two color PMTs + forward scatter), does not allow compensation between colors, does not allow linear analysis and is operated by rather inflexible software with limited capabilities. This is due to the fact that the cytometer has been designed and marketed as an instrument specific to a few particular assays, not as a multipurpose cytometer.

Crucian, Brian↗

Ionic Diffusion in Slurry Electrolytes for Redox Flow Batteries

Slurry electrodes have been proposed as a method to decouple the storage and power capacities of hybrid redox flow batteries by allowing the reduced metal to adhere to a flowing dispersion of electrically conductive particles rather than accumulate in the flow cell. In this work, the ionic mass transport through these slurry electrolytes is investigated via voltammetry at a rotating disc electrode and in a parallel channel flow cell. A modified Levich equation, i l = 0.6 2 nFC ω 1 / 2 ν − 1 / 6 ( D + r 2 Φ ω m ) 2 / 3 , is developed to describe limiting currents to a rotating disc electrode when using a particle filled electrolyte. Mass transfer is demonstrated to be enhanced by greater particle loading so long as there are sufficient particles such that their respective flow velocity boundary layers interact. In the flow cell, faradaic current in a carbon black slurry electrolyte was observed to decrease over time. This suggests that the carbon particles adhere and accumulate on the stationary electrode, impeding mass transport by imposing diffusion path tortuosity. This accumulation is undesirable in hybrid redox flow batteries as it encourages metal deposition in the cell, limiting the scalability of the technology.

Electrochemistry↗

Desorption of plutonium from montmorillonite: An experimental and modeling study

Desorption of plutonium (Pu) will likely control the extent to which it is transported by mineral colloids. In this article, we evaluated the adsorption/desorption behavior of Pu on SWy-1 montmorillonite colloids at pH 4, pH 6, and pH 8 using batch adsorption and flow cell desorption experiments. After 21 days adsorption, Pu(IV) affinity for montmorillonite displayed a pH dependency, with K d values highest at pH 4 and lowest at pH 8. The pH 8 experiment was further allowed to equilibrate for 6 months and showed an increase in K d , indicating that true sorption equilibrium was not achieved within the first 21 days. For the desorption experiments, aliquots of the sorption suspensions were placed in a flow cell, and Pu-free solutions were then pumped through the cell for a period of 12 days. Changes in influent solution flow rate were used to investigate the kinetics of Pu desorption and demonstrated that it was rate-limited over the experimental timescales. At the end of the 12-day flow cell experiments, the extent of desorption was again pH dependent, with pH 8 > pH 6 > pH 4. Further, at pH 8, less Pu was desorbed after an adsorption contact time of 6 months than after a contact time of 21 days, consistent with an aging of Pu on the clay surface. In addition, a conceptual model for Pu adsorption/desorption that incorporated known surface-mediated Pu redox reactions was used to fit the experimental data. The resulting rate constants indicated processes occurring on timescales of months and even years which may, in part, explain observations of clay colloid-facilitated Pu transport on decadal timescales. Importantly, however, our results also imply that migration of Pu adsorbed to montmorillonite colloids at long (50–100 year) timescales under oxic conditions may not be possible without considering additional phenomena, such as co-precipitation.

54 ENVIRONMENTAL SCIENCES↗

Are those bugs reflective? Non-destructive biofilm imaging with white light interferometry

White light interferometry (WLI) is not typically used to image bacterial biofilms that are immersed in water because there is insufficient refractive index contrast to induce reflection from the biofilm’s interface. The soft structure and water-like bulk properties of hydrated biofilms make them difficult to characterize in situ by any means, especially in a non-destructive manner. Here we describe a new method for measuring and monitoring the thickness and topology of live biofilms using a WLI microscope. A microfluidic system was used to create a reflective interface on the surface of biofilms. Live biofilm samples were monitored non-destructively over time. The method enables surface metrology measurements (roughness, surface area) and a novel approach to measuring thickness of the thin hydrated biofilms. Increase in surface roughness preceded observable increase in biofilm thickness, indicating that this measure may be used to predict future development of biofilms. We have also developed a flow cell that enables WLI biofilm imaging in a dynamic environment. We have used this flow cell to observe changes in biofilm structure in response to changes in environmental conditions - flow velocity, availability of nutrients, and presence of biocides.

bacteria↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗

Detection of endogenous alkaline phosphatase activity in intact cells by flow cytometry using the fluorogenic ELF-97 phosphatase substrate

BACKGROUND: The alkaline phosphatase (AP) substrate 2-(5'-chloro-2'-phosphoryloxyphenyl)-6-chloro-4-(3H)-quinazolinone (ELF((R))-97 for enzyme-labeled fluorescence) has been found useful for the histochemical detection of endogenous AP activity and AP-tagged proteins and oligonucleotide probes. In this study, we evaluated its effectiveness at detecting endogenous AP activity by flow cytometry. METHODS: The ELF-97 phosphatase substrate was used to detect endogenous AP activity in UMR-106 rat osteosarcoma cells and primary cultures of chick chondrocytes. Cells were labeled with the ELF-97 reagent and analyzed by flow cytometry using an argon ultraviolet (UV) laser. For comparison purposes, cells were also assayed for AP using a Fast Red Violet LB azo dye assay previously described for use in detecting AP activity by flow cytometry. RESULTS: The ELF-97 phosphatase substrate effectively detected endogenous AP activity in UMR-106 cells, with over 95% of the resulting fluorescent signal resulting from AP-specific activity (as determined by levamisole inhibition of AP activity). In contrast, less than 70% of the fluorescent signal from the Fast Red Violet LB (FRV) assay was AP-dependent, reflecting the high intrinsic fluorescence of the unreacted components. The ELF-97 phosphatase assay was also able to detect very low AP activity in chick chondrocytes that was undetectable by the azo dye method. CONCLUSIONS: The ELF-97 phosphatase assay was able to detect endogenous AP activity in fixed mammalian and avian cells by flow cytometry with superior sensitivity to previously described assays. This work also shows the applicability of ELF-97 to flow cytometry, supplementing its previously demonstrated histochemical applications. Copyright 1999 Wiley-Liss, Inc.

Non-NASA Center↗

Influence of Calcium Concentration on Permeability Changes in Flow-paths Altered by Highly Alkaline Groundwater - 17129

Groundwater around the geological repository of HLW is altered to the highly alkaline and Ca-rich condition by the constituents leaching from cementitious materials. Under such condition, the formation of CSH will affect the migration of radionuclides with the change in the hydraulic and chemical properties of the fracture (micro flow-path) in the host rock. In particular, the clogging effect with the deposition of CSH in the flow path the may contribute the retardation of radionuclide migration. In this study, the influence of Ca concentration on such clogging effect in the micro flow-path under the highly alkaline condition was examined by estimating the permeability changes with the deposition of CSH. In the experiment, the micro fractures in host rock were simulated by the micro flow-cell nipping the Teflon sheet (80 μm of thickness) between a granite chip and Teflon basement. The flow experiment was conducted by continuously injecting Ca solution to the micro flow-cell with constant flow rate. The concentrations of Ca ions for the injection solution were set in the range from 0 to 7.5 mM, and the value of pH was 12.5. As a result, under all conditions of Ca concentrations, the permeability in the flow path decreased to the range of 1. 10{sup -10} to 2.0x10{sup -10} m{sup 2} with the deposition of CSH. Besides, such decreased permeability was almost constant with increasing and decreasing periodically. Such increase and decrease in the permeability will be caused by the deposition and outflow of CSH formed in the flow path. In other words, because CSH is stable in pH higher than at least 10, under the condition with no man-made outlet such as real underground around the repository of radioactive waste, most CSH might clog through the flow-paths in the spatial range where pH exceeds at least 10, contributing the retardation effect of the migration of radionuclides released from the repository. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of Porous Medium Heterogeneity on Vadose Zone Desiccation: Intermediate-scale Laboratory Experiments and Simulations

Soil desiccation (drying), involving water evaporation induced by dry gas injection, is a potentially robust vadose zone remediation process to limit contaminant transport through the vadose zone. A series of four intermediate-scale flow cell experiments was conducted in homogeneous and simple layered heterogeneous porous medium systems to investigate the effects of heterogeneity on desiccation of unsaturated porous media. The permeability ratios of porous medium layers ranged from about five to almost two orders of magnitude. The insulated flow cell was equipped with twenty humidity and temperature sensors and a dual-energy gamma system was used to determine water saturations at various times. The multiphase code STOMP was used to simulate the desiccation process. Results show that injected dry gas flowed predominantly in the higher permeability layer and delayed water removal from the lower permeability material. For the configurations tested, water vapor diffusion from the lower to the higher permeability zone was considerable over the duration of the experiments, resulting in much larger relative humidity values of the outgoing air than based on permeability ratios alone. Acceptable numerical matches with the experimental data were obtained when an extension of the saturation-capillary pressure relation below the residual water saturation was used. The agreements between numerical and experimental results suggest that the correct physics are implemented in the simulator and that the thermal and hydraulic properties of the porous media, flow cell wall and insulation materials were properly represented.

contaminant transport↗

Recovery of dilute aqueous butanol by membrane vapor extraction with dodecane or mesitylene

A novel, nearly isothermal, nonselective-membrane separation process, membrane vapor extraction (MVE), efficiently recovers butanol from a dilute aqueous solution, for example, from a fermentation broth (Liu et al., 2015). In MVE, feed and solvent liquids are not in contact; they are separated by vapor. Therefore, compared to conventional extraction, MVE avoids formation of difficult-to-separate emulsions. In MVE, a semi-volatile aqueous solute (e.g., butanol) vaporizes at the upstream side of a membrane, diffuses as a vapor through the membrane pores, and subsequently condenses and dissolves into a high-boiling nonpolar solvent, favorable to the solute but not to water. Design analysis of a 1.5-m long, 30-m 2 membrane-area countercurrent MVE unit for processing 2-wt% aqueous butanol by dodecane solvent at 40 °C indicates over 90% recovery of the feed butanol with essentially no water loss and with very low energy requirement (Liu et al., 2015). The separation factor is over 1500. However, the published design study gives no experimental evidence for the calculated MVE separation. Here, we present experimental data to validate the MVE process. We use an omniphobic (i.e., hydrophobic and oleophobic), 0.2-µm pore-diameter Versapor®200 R membrane (Pall Corporation, Exton, PA) housed in a 6-cm wide by 10-cm long plate-and-frame channeled flow cell with 0.8-cm gap thickness. Membrane transfer area is 28 cm 2 . The membrane flow cell is designed for minimal axial concentration change and is operated in the transient mode between two recirculating flow loops. 2-wt% aqueous butanol is extracted into dodecane or mesitylene at 25 or 40 °C. Also, 1.5-wt% furfural is extracted into dodecane at 40 °C. Since vapor transport across the membrane contributes minimal resistance, MVE performance is governed by mass transfer through feed and solvent boundary layers. Mass-transfer coefficients are determined from the Graetz-Lévêque analysis of laminar thin-slit flow (Bird et al., 2002). Predicted extraction performance agrees well with experiment using no adjustable parameters. Finally, consistent with the initial multistage-design analysis (Liu et al., 2015), our new bench-scale experimental results confirm that MVE is a viable separation process to recover dilute semi-volatile biosolutes from water with minimal energy requirement. Preliminary analysis of downstream solute recovery from the extract via distillation is more efficient than that for pervaporation because of insignificant water carry over through the MVE membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vadose Zone Soil Moisture Wicking Using Super Absorbent Polymers

Super-absorbent polymers (SAPs) have the potential to remove water and associated contaminants from unsaturated sediments in the field. Column and flow cell experiment were conducted to test the ability of four types of SAPs to remove water from unsaturated porous media. Column experiments, with emplacement of a layer of polymer on top of unsaturated porous media, showed the ability of the SAPs to extract up to 80% of the initially emplaced water against gravity into the sorbent over periods up to four weeks. In column experiments where the sorbent was emplaced between layers of unsaturated porous media, gel formation was observed at both the sorbent-porous medium interfaces. The extraction percentages over four weeks of contact time were similar for both column configurations and no obvious differences were observed for the four tested SAPs. Two different flow cells were used to test the wicking behavior of SAPs in two dimensions using three configurations. The largest removal percentages occurred for the horizontal sorbent layer configuration which has the largest sorbent-porous medium interfacial area. In a larger flow cell, a woven nylon “sock” was packed with sorbent and subsequently placed between perforated metal plates, mimicking a well configuration. After one week of contact time the sock was removed and replaced by a fresh sock. The results of this experiment showed that the sorbent was able to continuously extract water from the porous media, although the rate decreased over time. The declining yield during both periods is associated with the sharp reduction in water saturation and relative permeability near the sorbent. It was also observed that the capillary pressure continued to increase over the total contact time of 14 days, indicating that the sorbent remained active over that period. This work has demonstrated the potential of soil moisture wicking using SAPs at the proof-of-principle level.

contaminants↗

RECALIBRATION OF H CANYON ONLINE SPECTROPHOTOMETER AT EXTENDED URANIUM CONCENTRATION

The H Canyon online spectrophotometers are calibrated for measurement of the uranium and nitric acid concentrations of several tanks in the 2nd Uranium Cycle.[1] The spectrometers, flow cells, and prediction models are currently optimized for a process in which uranium concentrations are expected to range from 0-15 g/L and nitric acid concentrations from 0.05-6 M. However, an upcoming processing campaign will involve 'Super Kukla' material, which has a lower than usual enrichment of fissionable uranium. Total uranium concentrations will be higher, spanning approximately 0-30 g/L U, with no change in the nitric acid concentrations. The new processing conditions require the installation of new flow cells with shorter path lengths. As the process solutions have a higher uranium concentration, the shorter path length is required to decrease the absorptivity to values closer to the optimal range for the instrument. Also, new uranium and nitric acid prediction models are required to span the extended uranium concentration range. The models will be developed for the 17.5 and 15.4 tanks, for which nitric acid concentrations will not exceed 1 M. The restricted acid range compared to the original models is anticipated to reduce the measurement uncertainty for both uranium and nitric acid. The online spectrophotometers in H Canyon Second Uranium Cycle were modified to allow measurement of uranium and nitric acid for the Super Kukla processing campaign. The expected uranium concentrations, which are higher than those that have been recently processed, required new flow cells with one-third the optical path length of the existing cells. Also, new uranium and nitric acid calibrations were made. The estimated reading uncertainties (2{sigma}) for Tanks 15.4 and 17.5 are {approx}5% for uranium and {approx}25% for nitric acid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a Flow-through Cell for Ultrasonic Extraction (UE)─Single Particle (SP)─ICP-MS─an Approach for Nano/Microparticle Elemental and Isotopic Analysis

Nanotechnology is a salient part of the scientific landscape, and analytical approaches are rapidly evolving to enable small-scale characterization of nano- and microparticle compositions and impurities. Here, a flow-through sonicating cell was developed for direct particle extraction from a silicon wafer and integrated with an inductively coupled plasma–mass spectrometer (ICP-MS) for subsequent elemental and isotopic characterization of the released particles. Ultrasonic extraction (UE)─single particle (SP)─ICP-MS offers controlled particle mobilization from solid substrates and allows for increased sample throughput by eliminating the need for pre-extraction of particles and decreasing sample preparation steps. Coupling this device to an ICP-MS with a time-of-flight (TOF) mass analyzer, it is possible to distinguish unique isotopic compositions of the particles. Both tungsten and nickel isotopically tagged particles, which were deposited on Si wafers, are presented here with analysis via UE─SP─ICP-MS. This approach could support efforts in the fields of particle synthesis, nuclear safeguards and forensics, environmental monitoring, and semiconductor industries in which the detection of particles from substrates and wafers is critical.

Paul, Molly [ORNL] (ORCID:0009000009672055)↗

Cost and size estimates for an electrochemical bulk energy storage concept

Preliminary capital cost and size estimates were made for an electrochemical bulk energy storage concept for a redox-flow-cell system. Preliminary calculations showed that the redox-flow-cell system has great promise as a bulk energy storage system for power load leveling. The size of the system was estimated to be less than 2 percent of the size of a comparable pumped hydroelectric storage plant.

Warshay, M.↗