Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flue gas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Nitrogen evolution, NO X formation and reduction in pressurized oxy coal combustion

Oxy-combustion is one of the most prominent solutions for reducing CO 2 emissions from coal-fired power plants using carbon-capture-and-utilization technology. However, when compared to air combustion at atmospheric pressure, oxy-combustion is very expensive, owing to the significant efficiency penalties associated with air separation, flue gas recirculation (FGR), treatment, compression, and storage or transit of CO 2 . In comparison, pressurized oxy-combustion (POC) is more efficient as it recovers a significant amount of heat energy from the flue gas moistures. Nevertheless, CO 2 derived from pressurized oxy coal combustion has impurities, e.g., acid gases (NO X and SO X ) that can corrode the plant equipment, transport lines as well as deteriorating effect on the environment. Fortunately, in pressurized combustion systems, both NO X and SO X can be scrubbed by a single-column direct contact cooler (DCC), but this requires a minimum ratio of NO X to SO X at the inlet to be efficiently removed. Therefore, NOx is one of the important hindering parameters in commercializing the pressurized oxy-combustion. Although NOx evolution during oxy-coal combustion has been explored extensively at 1 atm, higher pressure studies are rare. Much still needs to be done to better understand the NO X mechanism and the effects of different parameters on NO X emissions under these conditions. Here, this paper reviews the published literature on nitrogen evolution, NO X formation and reduction in pressurized oxy-coal combustion. At higher pressures, the NO X from fuel-bound nitrogen is generated through volatiles, tar and char, all of which are discussed. Where literature is not available, the effect of pressure on NOx evolution in different stages of coal combustion is predicted through CHEMKIN simulation. Homogeneous and heterogeneous pathways of NO X formation and their destruction in pressurized oxy-coal combustion are evaluated. Additionally, the effect of pressure on a few mature and commercialized NOx abatement methods is explored. In the last, the future perspective and recommendation are given. This review will aid in the provision of basic knowledge about NOx evolution and control in pressurized fuel combustion, as well as the identification of new research areas to pursue.

01 COAL, LIGNITE, AND PEAT↗

Mass transfer coefficients, kL, and air-CO2 ingassing rates in 3.4 m2 and 1-acre raceway ponds.

The US DOE 2016 Billion Ton Update (Langholtz 2016) projected that CO2 in flue-gas from power plants or similar sources would limit U.S. algal biofuel potential to under 5 billion gallons gasoline equivalent (gge) per year, due to lack of sufficient land, water and other requirements near such flue gas sources. 2nd generation carbon capture technologies are proposed to overcome this constraint (Davis 2017), and could expand this resource potential nearly 10-fold, assuming CO2 costs near the future, 2025 DOE NETL, goal of $40/metric ton CO2. An alternative pathway is the direct uptake of air CO2 into the algal ponds through an increase in the air-CO2 transfer rate resulting from the reaction of CO2 with hydroxide ions. However, such a ‘chemical enhancement’ in mass transfer depends on a high pH in the culture, and, by extension, the ability of microalgae to maintain high rates of carbon assimilation under such conditions. Abiotic experiments characterized the air-CO2 mass-transfer rate in 1-acre and 3.4 m2 raceway ponds as a function of pH, with rates approaching 10 g C/m2-day at pH 12 in the brackish water tested, equivalent to a biomass productivity potential of near 20 g AFDW/m2-day (@ 0.47 g C/g AFDW). The mass transfer rate was found to be nearly independent of the mass-transfer coefficient, indicating that at turbulence levels achievable in typical raceway ponds, the system is reaction rate, rather than diffusion limited. In biotic trials with an unknown green microalga, biomass productivity in ponds receiving CO2 from only direct surface air-CO2 exchange averaged 5 +/- 0.5 g AFDW/m2-day in August - September central California conditions, about half-that of experimental controls fertilized with supplemental CO2. pH in the air-only treatment reached a maximum of 10.5, supporting a model predicted air-CO2 ingassing rate between 2-3 g C/m2-day, consistent with the observed biomass carbon assimilation rate. Results suggest that unique alkaliphilic strains are required if reliant on direct in-pond air-CO2 transfer for algal inorganic carbon supply, and that reaching an economically viable biomass productivity will require strains that thrive at pH 11 and above.

09 BIOMASS FUELS↗

Design and Experimental Demonstration of an Additive Manufactured Smart Oxy-Methane Burner for High Pressure and Supercritical Combustion

Pressurized oxy combustion-based systems can improve efficiency by recovering latent heat of the steam in the Flue Gas and achieving 90% CO2 capture. In addition, the novel Directly Heated Supercritical Carbon Dioxide (DH-SCO2) power cycles can achieve high thermal efficiencies and provide nearly full carbon capture. Additionally, due to the reduction of flue gas at higher pressure, smaller system size and capital cost reductions are also possible. Recent thermodynamic analysis of the DH-SCO2 cycle performed by the UTEP research team shows that combustion conditions in the vicinity of 300 bar pressure and 1000-1400 K temperature allow for relatively high system efficiencies while operating within the limit of available combustor materials. However, the realization of a directly heated supercritical power cycle requires combustion systems to operate in supercritical conditions and at temperature far below the blowout limit of conventional flames (above 1500 K). The thermodynamic properties along with the combustion properties and kinetics are unexplored at such conditions. Additionally, the interaction of the supercritical environment with energy components is also unknown. High-pressure combustion tests are performed using a smart burner at some intermediate pressure ranges (<20 bar) to help minimize these knowledge gaps. The knowledge obtained from the high-pressure test will assist in understanding the combustion chamber pressurization mechanism, ignition and flame behavior at the elevated pressure. The obtained data will act as a systematic first step in testing at higher pressures of 100 and 300 bar pressures.The primary purpose of this Dissertation is to demonstrate the operability of a low NOx smart burner for oxy-methane combustion at high pressure (< 20 bar) and scalable up to supercritical conditions. A shear co-axial smart burner is designed with a real-time temperature monitoring capability to understand the burner face interaction at high-pressure conditions. In addition, the burner has four independent injection ports to allow the independent injection of fuel and dilution gases in the combustor. The maximum operating capability of the burner is 575 kWth. The burner was fabricated using a Laser Powder Bed Fusion process with Nickel Alloy 718. A powder removal technology was invented comprising ultrasonic vibration, liquid nitrogen exposure and media blasting to remove powders from internal channels of the burner. The burner operability tests are performed in the high-pressure combustor and the swirl combustor. The high-pressure combustor was used to investigate the burner operability and thermal soak back at different pressurized conditions. The experimental tests in high-pressure combustor up to 275 kWth input resulted in 16.5 bar chamber pressure and 198°C thermal soaks back to the burner. The burner was capable of providing the required thermal input within a 3% deviation range. In addition, soot formation occurred at high-pressure tests. The swirl combustor was used to observe the flame stability of the burner. Flame lift-off was observed for jet velocities above 450 m/s. Additionally, lift-off decreased for low co-flow velocities. CO2 dilution experiments showed increased flame instabilities for all conditions above 50% dilution ratios. At lower thermal inputs, partial flame blow-offs occurred for dilution ratios above 50%. All conditions significantly reduced the flame temperature and increased the flame lift-off height. Finally, a 2nd generation AM smart burner was designed using the knowledge from the 1st generation burner experiments. The 2nd generation burner incorporated two sets of swirlers with 0.9 swirl no. A cooling system was also designed for long-duration tests at higher pressures. The thermal input and division of the burner's power are kept the same as the 1st generation burner. The burner is to be fabricated using nickel-alloy 718 for high-pressure handling capability. The design can sustain at high-pressure conditions up to 100 bar.

Islam, Md Nawshad Arslan↗

A Process with Decoupled Absorber Kinetics and Solvent Regeneration through Membrane Dewatering and In-Column Heat Transfer (Final Report)

This report summarizes the work conducted on project DE-FE0031604 where University of Kentucky Center for Applied Energy (UK CAER) has validated its intensified CO 2 capture process through substantial enhancements to the kinetics of the absorption process and energy reductions by absorber temperature profile modification, dewatering and heat integration technologies for achieving significant capital and operating cost reductions. To address DOE’s objective of improving post-combustion CO 2 capture technology and reducing associated cost, UK CAER employed an intensified process which combined three key aspects targeted at overcoming inherent limitations or barriers in the conventional CO 2 capture and desorption process. The process designed to be independent of the type of solvent used, included (1) the use of 3-D printed two-channel structured packing material to control the temperature profile and increase the CO 2 absorption rate in the absorber, (2) a zeolite membrane dewatering unit for dewatering of the carbon-rich solvent to decouple solvent concentration needs for CO 2 absorption and desorption, and (3) a rich-split feed with two-phase flow heat transfer prior to the stripper that provided a secondary point of vapor generation to provide energy savings in steam extraction and solvent regeneration. The project was executed over two budget periods. This involved testing of individual process components which included the advanced heat transfer packing and the dewatering membrane on UK CAER’s 30 liter per minute (L/min) CO 2 (3” Column) capture bench unit with simulated flue gas in the first budget period. Subsequent scaled-up testing of these components together with the split-feed configuration were also tested in UK CAER’s 0.1 MWth CO 2 capture unit with coal-derived flue gas in the second-budget period. Long term studies were done during this period to assess process and solvent performance over extended duration. Project partners Lawrence Livermore National Laboratory (LLNL) and Media & Process Technology (MPT) led the development efforts for the advanced packing material and dewatering membrane respectively. Data from the long term testing was used as input for an environmental, health and safety (EH&S) assessment for the process and scaled technology performed by ALL4 LLC. Trimeric Corporation also completed a techno-economic analysis (TEA) for the UK CAER technology which was compared to the DOE reference Case B12B. Tests on the 3” column capture unit showed that the advanced heat transfer packing could be used to lower the bulge temperature in the absorber, and this was also proven in the scaled testing in the 0.1 MWth CO 2 capture unit. The bulge temperature could be lowered by >10 °C, changing the temperature profile in the absorber, and showed potential to enhance absorption with the ability to tailor the profile to provide conditions suitable for a solvent’s properties and kinetics. Conditions for short term evaluation of a 19” zeolite dewatering membrane on the 3” column capture unit yielded desirable fluxes and sustained rejection rates of >80%. However, for the scaled testing of six membrane modules consisting of 21 parts of 31-inch-long membrane tubes in each bundle (surface area 0.3 m 2 ), over a more extended duration, similar rejection rates could not be achieved. With the split-feed of the rich stream to the stripper, improved heat recovery minimized waste heat exiting the top of the stripper. The stripper exhaust temperatures could be reduced by >10 °C; reducing the amount of water vaporization contributed to lowering the regeneration energy by ~ 15%. The energy benefit could be sustained from the long term monitoring of the solvent performance. The solvent properties were not significantly impacted over the long-term operations. The benefits of the UK CAER process demonstrated experimentally were mostly validated from the TEA comparing a commercial scale application of the technology to DOE reference Case B12B. The cost of CO 2 capture for the UK CAER technology was estimated to be ~$34.97/tonne of CO 2 captured; a reduction of 23% compared to Case B12B. The increase in cost of electricity was also shown to be 16% lower than that of Case B12B. The total parasitic demand was also shown to be 11% lower. The key drivers for the benefits are a result of the process intensification approaches employed in the UK CAER technology for enhanced solvent performance, effective heat recovery and improved energy performance. The EH&S assessment did not find any major environmental concerns or barriers to the full scale implementation of the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Sorbents for the oxidation and removal of mercury

A promoted activated carbon sorbent is described that is highly effective for the removal of mercury from flue gas streams. The sorbent comprises a new modified carbon form containing reactive forms of halogen and halides. Optional components may be added to increase reactivity and mercury capacity. These may be added directly with the sorbent, or to the flue gas to enhance sorbent performance and/or mercury capture. Mercury removal efficiencies obtained exceed conventional methods. The sorbent can be regenerated and reused. Sorbent treatment and preparation methods are also described. New methods for in-flight preparation, introduction, and control of the active sorbent into the mercury contaminated gas stream are described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sorbents for the oxidation and removal of mercury

A promoted activated carbon sorbent is described that is highly effective for the removal of mercury from flue gas streams. The sorbent comprises a new modified carbon form containing reactive forms of halogen and halides. Optional components may be added to increase reactivity and mercury capacity. These may be added directly with the sorbent, or to the flue gas to enhance sorbent performance and/or mercury capture. Mercury removal efficiencies obtained exceed conventional methods. The sorbent can be regenerated and reused. Sorbent treatment and preparation methods are also described. New methods for in-flight preparation, introduction, and control of the active sorbent into the mercury contaminated gas stream are described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sorbents for the oxidation and removal of mercury

A promoted activated carbon sorbent is described that is highly effective for the removal of mercury from flue gas streams. The sorbent comprises a new modified carbon form containing reactive forms of halogen and halides. Optional components may be added to increase reactivity and mercury capacity. These may be added directly with the sorbent, or to the flue gas to enhance sorbent performance and/or mercury capture. Mercury removal efficiencies obtained exceed conventional methods. The sorbent can be regenerated and reused. Sorbent treatment and preparation methods are also described. New methods for in-flight preparation, introduction, and control of the active sorbent into the mercury contaminated gas stream are described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sorbents for the oxidation and removal of mercury

A promoted activated carbon sorbent is described that is highly effective for the removal of mercury from flue gas streams. The sorbent comprises a new modified carbon form containing reactive forms of halogen and halides. Optional components may be added to increase reactivity and mercury capacity. These may be added directly with the sorbent, or to the flue gas to enhance sorbent performance and/or mercury capture. Mercury removal efficiencies obtained exceed conventional methods. The sorbent can be regenerated and reused. Sorbent treatment and preparation methods are also described. New methods for in-flight preparation, introduction, and control of the active sorbent into the mercury contaminated gas stream are described.

Olson, Edwin S.↗

Sorbents for the oxidation and removal of mercury

A promoted activated carbon sorbent is described that is highly effective for the removal of mercury from flue gas streams. The sorbent comprises a new modified carbon form containing reactive forms of halogen and halides. Optional components may be added to increase reactivity and mercury capacity. These may be added directly with the sorbent, or to the flue gas to enhance sorbent performance and/or mercury capture. Mercury removal efficiencies obtained exceed conventional methods. The sorbent can be regenerated and reused. Sorbent treatment and preparation methods are also described. New methods for in-flight preparation, introduction, and control of the active sorbent into the mercury contaminated gas stream are described.

Olson, Edwin S.↗

Techno-Economic Analysis and Optimization for MOF-Based CO2 Capture from NGCC Applications

This poster presents the development of isotherm and contactor models for a tetraamine MOF for CO2 capture from NGCC flue gas sources. It presents results for development of an isotherm model for a tetraamine MOF, validation of a fixed bed model to experimental fixed bed breakthrough data, and optimization of a fixed bed TSA process and moving bed TSA process for CO2 capture from a NGCC flue gas source.

Matuszewski, Michael↗

Generating Emissions Inventory for Carbon Capture and Storage Analysis for Carbon-Intensive Industrial Sectors

Decarbonizing the industrial sector is critical to achieve carbon dioxide (CO2) emissions reductions goals of the Biden Administration. Currently available decarbonization options include electrification, fuel switching to zero carbon fuels like green hydrogen (H2) and carbon capture and storage (CCS). Application of post-combustion carbon capture (PCCC) technology in the power sector, as well as research at the U.S. Department of Energy's Fossil Energy and Carbon Management (FECM) Office has shown that its application in the industrial sector could have co-benefits in the form of emissions reductions of non-CO2 regulated pollutants. For example, solvent based PCCC systems require pre-conditioning of flue gas to remove sulfur and particulate matter (PM) upstream of the CO2 absorber. However, there is a lack of understanding about the type of non-CO2 pollutants which can be captured and the amount of reduction possible. PCCC application differs across industrial sectors as it depends on the availability of decarbonization options, characteristics of industrial processes and the amount and composition of pollutant flows. Certain facilities can also have multiple effluent flows with or without a CO2 stream. As such, understanding industrial processes and their effluent flows in detail is required to quantify the co-benefits opportunities presented by PCCC. Considering this requirement, the goal of this analysis is to develop a high-resolution inventory of effluent flows from facilities of 8 industrial sectors in the U.S. These industrial sectors - ethanol, ammonia, cement, steel, natural gas processing, hydrogen, petroleum refining and wood and pulp products - have carbon-intensive effluent flows, and thus are prime candidates for PCCC applications. In this study, we map the composition of pollutant flow from flue stacks across the identified facilities. Using data available in three Environmental Protection Agency (EPA) databases - the Green House Gas Reporting Program (GHGRP), the National Emissions Inventory (NEI) and the Toxic Release Inventory (TRI), we create a combined inventory which lists the type, amount, and concentration of pollutant flows. Using total weight of the pollutant flow back calculated from observed data for CO2 concentrations in flue gas for individual sectors, we calculate the concentration of each pollutant in the flue gas stream. Thus, the resultant emissions inventory includes the following details for each facility in the sector: facility-level and if possible, process-level pollutant flows, concentrations of pollutants in the flue gas, and geographical coordinates of the facilities. A detailed statistical analysis and summary allows us to search for erroneous data and remove them from the final inventory. The generation of the inventory is achieved using a python-based framework which can recreate this inventory for other industrial sectors as well as using newer releases of emission inventories from EPA. The statistical analysis performed on the inventory is also calibrated and automated to identify outliers efficiently.

air pollutants↗

Synthetic Calcium Carbonate Production by Carbon Dioxide (CO 2 ) Mineralization of Industrial Waste Brines

The global scale of CO 2 emission has crossed 36 B tons, and the United State represents 14% of the total emissions. In light of the high cost associated with current CO 2 capture processes ($60-to-150 per ton of CO 2 ), carbon capture and utilization (CCU), wherein CO 2 is converted to beneficial products, provides a pragmatic path to overcome the economic barrier for CO 2 emissions control. In particular, CO 2 mineralization offers an attractive route as it produces high-value mineral carbonates that sequester CO 2 in a stable form. For instance, fine precipitated calcium carbonate, a valuable product with unit price in the range of $230-280/t and a global market projected to reach 99 M tons in 2020, can be produced by capturing CO 2 within aqueous Ca 2+ solution. However, two critical challenges need to be overcome—(i) the need for costly processes such as electrolysis or addition of alkali hydroxides to maintain alkalinity during mineralization, and (ii) the geographic availability of Ca-rich solutions (or brines) which often renders efficient integration with power plants impractical. To simultaneously address these challenges, this project developed two novel routes to enable carbonate production based on efficient CO 2 mineralization. In one variation, the project developed a new alkaline carbonation process to capture CO 2 and produce calcite precipitates from coal ashes. Herein, coal ash is carbonated first in a sodium carbonate solution. The carbonation reaction produces sodium hydroxide and raises the solution pH. This high-pH hydroxide solution is then used for CO 2 capture, which converts the sodium hydroxide solution back to sodium carbonate to repeat the carbonation cycle. The carbonated ash residue is refined with a CO 2 pressure swing step to produce high-purity precipitated calcium carbonate. In another variation, Ca-rich produced water brine serves as the Ca-source to mineralize CO 2 . An H + /Na + ion-exchange cycle was designed to provision alkalinity during mineralization and regenerate the ion-exchange reagent in brines with high salinity. Ca-depleted brines can then be treated within a centralized water treatment facility. Both variations beneficially utilize reject streams—such as coal ashes and brines from oil and gas extraction or CO 2 storage operations—that are available at substantial quantities in the vicinity of coal power plants within the U.S. In addition to technology development, this project included techno-economic and life-cycle analysis to identify technically and economically appropriate solutions for power plants in different geographic locations. Taken together, the project provides a unique route to integrate CO 2 emissions control and waste handling/treatment for coal power plants, while producing a high-value product to offset the economic burden associated with waste management. The developed processes utilize post-desulfurization flue gas from coal-fired power plants as is. The CO 2 conversion reactions are performed in alkaline brines at ambient pressure from the flue gas, thereby minimizing the energy burden. By beneficiation of industrial waste streams with low energy input, the processes offers significant technical advantages in energy and CO 2 footprint over the current paradigm of precipitated calcium carbonate production, which involves calcination of limestone at processing temperatures in excess of 800 °C. Overall, this project developed viable CO 2 mineralization processes while strategically maximizing the economic benefit.

01 COAL, LIGNITE, AND PEAT↗

A data-driven model for thermodynamic properties of a steam generator under cycling operation

The varying electricity demand from coal power plants due to the intermittent nature of renewable sources leads to load-follow and on/off operations referred to as cycling. Cycling causes transients of properties such as pressure and temperature within various components of the steam generation system.These transients cause increased damage because of fatigue and creep-fatigue interactions shortening the life of components. An algorithm is developed to identify cycling operations from the gross power data. The data-driven model based on artificial neural networks (ANN) is developed using 10 years data from Coal Creek Station power plant located in North Dakota, USA to estimate properties of the steam generator components during cycling operations. Furthermore, the uniqueness of this model is the ability to predict component properties for the cycling as well as base-load operations and is reported for the first time. The ANN model estimates the component properties, for a given gross power profile and initial conditions, as they vary during cycling operations. As a representative example, the ANN estimates are presented for the superheater outlet pressure, reheater inlet temperature, and flue gas temperature at the air heater inlet. The changes in these variables as a function of the gross power over the time duration are compared with measurements to assess the predictive capability of the model. Mean square errors of 4.49E-04 for superheater outlet pressure, 1.62E-03 for reheater inlet temperature, and 4.14E-04 for flue gas temperature at the air heater inlet were observed.

01 COAL, LIGNITE, AND PEAT↗

Aqueous Bromide Discharges from U.S. Coal-Fired Power Plants: Points of Origin, Concentration Ranges, and Effluent Treatment Costs

Bromide discharges from coal-fired power plants have received increased attention from regulatory bodies due to their contribution to the formation of disinfection byproducts (DBPs) in downstream drinking water treatment plants. Here, this paper characterizes the relative contributions of bromide from coal feedstocks and bromine-based mercury control processes, estimates the distribution of bromide concentrations at 85 active coal-fired power plants across the United States (U.S.) with wet flue gas desulfurization units, and estimates the cost of bromide removal from wastewater discharge using year 2020 data. Bromide discharges are estimated at the plant level using a combination of the reported coal rank and composition combusted, estimates of bromide addition in mercury control techniques under multiple halogen addition scenarios, and the estimated flue gas desulfurization (FGD) wastewater flow rate. The median, simulated plant-level estimation of total FGD wastewater flow is 18.3 gallons/min at a bromide concentration of 319 mg/L, equivalent to ~11.6 tonnes/year of bromide discharges to the environment. Next, we evaluated the expected cost of employing the best available technology (BAT) to control bromide discharges in FGD wastewater to prevent contributions to DBP formation. Treatment would need to remove more than 99.8% of bromide to reach the 0.2 mg/L voluntary incentive program (VIP) limit. The total cost of treatment depends on whether disposal is on- or off-site; the average costs for all plants combined come to an average of $110 million ($95.2/kgal) in 2021 U.S. dollars for on-site disposal, or $134 million ($115/kgal) for off-site disposal.

01 COAL, LIGNITE, AND PEAT↗

ROTA-CAP™: An Intensified Carbon Capture System Using Rotating Packed Beds (Final Scientific/Technical Report)

GTI Energy and Carbon Clean Solutions Limited successfully designed, constructed, and operated an integrated ROTA-CAP carbon capture skid. ROTA-CAP™ is a process intensification technology, applied for post-combustion carbon capture, which utilizes the centrifugal forces generated from rotation of rotating packed beds as well as advanced solvents to achieve increased mass transfer rates 1-2 orders of magnitude higher than conventional columns while substantially decreasing footprint. The test skid, which consisted of a dual stage RPB absorber with external interstage cooling and a single stage RPB regenerator, was operated at capacities up to 0.5 tonne/day of CO 2 capture with flue gas concentrations ranging from 4% to 22% CO 2 by vol. CO 2 removal rates greater than 95% were achieved, with CO 2 product purity also exceeding 95% by vol. Over 1,600 hours of operation were accumulated throughout the project, including over 1,000 hours of operation of the with real flue gas containing at least 9.8% CO 2 by vol. The skid was operated continuously for 24 hours per day and 7 days per week over the course of 7 long-term test campaigns, with the campaigns ranging from approximately 2-4 weeks per campaign. A techno-economic analysis was performed, and a cost of capture of $\$$41.18/tonne CO 2 was calculated for the ROTA-CAP process, compared to $\$$45.75/tonne for a Cansolv-based process. These results show a cost reduction of approximately 10% compared to the Cansolv-based process. Although this still exceeds the target cost of capture of $\$$30/tonne specified for this project, GTI expects that the cost of capture can be further reduced through further optimization of the design and technology. GTI also performed an engineering design review to determine the scale-up potential of the technology, with the results of the preliminary assessment indicating that it appears to be feasible to scale up the RPB technology to 4,000 TPD. It was also determined that both horizontal and vertical rotor orientations are feasible, though there are mechanical advantages to the vertical orientation.

20 FOSSIL-FUELED POWER PLANTS↗

Analysis of energetics and economics of sub-ambient hybrid post-combustion carbon dioxide capture

Adsorption of CO 2 from post-combustion flue gas is one of the leading candidates for globally impactful carbon capture systems. In this report, work focused on understanding the opportunities and limitations of sub-ambient CO 2 capture processes utilizing a multistage separation process. A hybrid process design using a combination of pressure-driven separation of CO 2 from flue gas (e.g., adsorption- or membrane-based separation) followed by CO 2 -rich product liquefaction to produce high-purity (>99%) CO 2 at pipeline conditions is considered. The operating pressure of the separation unit is a key cost parameter and also an important process variable that regulates the available heat removal necessary to reach the sub-ambient operating conditions. The economic viability of applying pressure swing adsorption (PSA) processes using fiber sorbent contactors with internal heat management was found to be most influenced by the productivity of the adsorption system, with productivities as high as 0.015 mol CO2 /kg sorb -1 sec -1 being required to reduce costs of capture below $60/ton CO 2 captured. This analysis was carried out using a simplified two-bed process, and thus there is opportunity for further cost reduction with exploration of more complex cycle designs. Three exemplar fiber sorbents (MIL-101(Cr), UiO-66, and zeolite 13X) were considered for application in the sub-ambient process of PSA unit. Among the considered sorbents, zeolite 13X fiber composites were found to perform better at ambient temperatures as compared to sub-ambient. MIL-101(Cr) and UiO-66 fiber composites had improved purity, recovery, and productivity at colder temperatures reducing costs of capture as low as $61/ton CO 2 . Future economic improvement could be achieved by reducing the required operating pressure of the PSA unit and pushing the Pareto frontier closer to the final pipeline requirement via a combination of PSA cycle design and material selection.

42 ENGINEERING↗

Continuous Water Quality Sensing for FGD Wastewater

The coal fired plant power industry requires new solutions for on-line monitoring of flue gas desulfurization (FGD) wastewaters for regulated trace metals to reduce recurring operating and off-site laboratory analysis costs and provide a high level of confidence of compliance with state and federal discharge guidelines. The University of Alabama at Birmingham (UAB) developed an integrated water sensor package for continuous water quality monitoring of flue gas desulfurization (FGD) wastewaters for concentration measurements of Selenium (Se). UAB utilized a diverse team of University Professors/Staff Members/Student(s) (Engineering and Innovative Technology Development Group), a University Affiliated Research Institution from the local area (Southern Research), and a cost sharing Industry Partner (Metrohm). The team developed and validated a proprietary wet chemistry batch process for water sample preparation; and implemented this process as a fully automated on-line monitor prototype system. This prototype system’s performance was evaluated in both the laboratory and during in-field deployment to a coal fired power plant. In both environments it was found that the prototype system was unable to recreate the batch process’s success at preparing FGD water samples for total Se measurements with a commercial-off-the-shelf (COTS) cyclic anodic stripping voltammetry (CSV) system. Through this experience, UAB has provided insight into a number of specific areas where improvements can be made with respect to the COTS systems used in this project to yield a more complete and competitive industry solution for on-line monitoring of total Se in industrial wastewater.

01 COAL, LIGNITE, AND PEAT↗

Carbon Capture Pilot at Vicksburg Containerboard Mill (Final Technical Report)

This is the final technical report for the DOE-OCED project DE-CD0000051. The report provides the progress at the close of the project. The objective of the project is to design and build a large pilot plant for carbon dioxide (CO 2 ) capture from a pulp and paper (P&P) mill using RTI’s non-aqueous solvent (NAS) technology at a capacity of 120,000 t-CO 2 /year, with >90% CO 2 captured. The pilot plant will be used for testing and evaluating the NAS capture process using real flue gas from the P&P mill’s power boiler for a minimum of 1 year of parametric testing and a minimum of 2,000 hours of continuous long-term testing. The testing will provide data for process optimization and scale-up for the P&P industry, provide information on interaction of flue gas contaminants on solvent performance and degradation, and inform strategies for emission control. At the end of the project, the pilot plant will be managed by International Paper (IP), the host site owner, which will continue to capture CO 2 , sequester the captured CO 2 , and be eligible for the 45Q credit.

42 ENGINEERING↗