Search NASA⌕ Search

SEARCH · Search NASA

Results for “Forearm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Application of acute maximal exercise to protect orthostatic tolerance after simulated microgravity

We tested the hypothesis that one bout of maximal exercise performed at the conclusion of prolonged simulated microgravity would improve blood pressure stability during an orthostatic challenge. Heart rate (HR), mean arterial blood pressure (MAP), norepinephrine (NE), epinephrine (E), arginine vasopressin (AVP), plasma renin activity (PRA), atrial natriuretic peptide (ANP), cardiac output (Q), forearm vascular resistance (FVR), and changes in leg volume were measured during lower body negative pressure (LBNP) to presyncope in seven subjects immediately prior to reambulation from 16 days of 6 degrees head-down tilt (HDT) under two experimental conditions: 1) after maximal supine cycle ergometry performed 24 h before returning to the upright posture (exercise) and 2) without exercise (control). After HDT, the reduction of LBNP tolerance time from pre-HDT levels was greater (P = 0.041) in the control condition (-2.0 +/- 0.2 min) compared with the exercise condition (-0.4 +/- 0.2 min). At presyncope after HDT, FVR and NE were higher (P < 0.05) after exercise compared with control, whereas MAP, HR, E, AVP, PRA, ANP, and leg volume were similar in both conditions. Plasma volume (PV) and carotid-cardiac baroreflex sensitivity were reduced after control HDT, but were restored by the exercise treatment. Maintenance of orthostatic tolerance by application of acute intense exercise after 16 days of simulated microgravity was associated with greater circulating levels of NE, vasoconstriction, Q, baroreflex sensitivity, and PV.

NASA Discipline Cardiopulmonary↗

Metabolic myopathies

Metabolic myopathies are disorders of muscle energy production that result in skeletal muscle dysfunction. Cardiac and systemic metabolic dysfunction may coexist. Symptoms are often intermittent and provoked by exercise or changes in supply of lipid and carbohydrate fuels. Specific disorders of lipid and carbohydrate metabolism in muscle are reviewed. Evaluation often requires provocative exercise testing. These tests may include ischemic forearm exercise, aerobic cycle exercise, and 31P magnetic resonance spectroscopy with exercise.

Review↗

Bone mineral loss and recovery after 17 weeks of bed rest

The purpose of this work was to determine the rate and extent of bone loss and recovery from long-term disuse and in particular from disuse after exposure to weightlessness. For this purpose, bed rest is used to simulate the reduced stress and strain on the skeleton. This study reports on the bone loss and recovery after 17 weeks of continuous bed rest and 6 months of reambulation in six normal male volunteers. Bone regions measured were the lumbar spine, hip, tibia, forearm, calcaneus, total body, and segmental regions from the total-body scan. The total body, lumbar spine, femoral neck, trochanter, tibia, and calcaneus demonstrated significant loss, p less than 0.05. Expressed as the percentage change from baseline, these were 1.4, 3.9, 3.6, 4.6, 2.2, and 10.4, respectively. Although several areas showed positive slopes during reambulation, only the calcaneus was significant (p less than 0.05), with nearly 100% recovery. Segmental analysis of the total-body scans showed significant loss (p less than 0.05) in the lumbar spine, total spine, pelvis, trunk, and legs. During reambulation, the majority of the regions demonstrated positive slopes, although only the pelvis and trunk were significant (p less than 0.05). Potential redistribution of bone mineral was observed: during bed rest the bone mineral increased in the skull of all subjects. The change in total BMD and calcium from calcium balance were significantly (p less than 0.05) correlated, R = 0.88.

Non-NASA Center↗

Securing Safety with Sensors

The Robot Systems Technology Branch at NASA's Johnson Space Center collaborated with the Defense Advanced Research Projects Agency to design Robonaut, a humanoid robot developed to assist astronauts with Extra Vehicular Activities (EVA) such as space structure assembly and repair operations. By working side-by-side with astronauts or going where risks are too great for people, Robonaut is expected to expand the Space Agency s ability for construction and discovery. NASA engineers equipped Robonaut with human-looking, dexterous hands complete with five fingers to accomplish its tasks. The Robonaut hand is one of the first being developed for space EVA use and is the closest in size and capability to a suited astronaut s hand. As part of the development process, an advanced sensor system was needed to provide an improved method to measure the movement and forces exerted by Robonaut s forearms and hands.

Source record↗

Comparison of Interstitial Fluid pH, PCO2, PO2 with Venous Blood Values During Repetitive Handgrip Exercise

We evaluated the use of a small, fiber optic sensor to measure pH, PCO2 and PO2 from forearm muscle interstitial fluid (IF) during handgrip dynamometry. PURPOSE: Compare pH, PCO2 and PO2 values obtained from venous blood with those from the IF of the flexor digitorum superficialis (FDS) during three levels of exercise intensity. METHODS: Six subjects (5M/1F), average age 29+/-5 yrs, participated in the study. A venous catheter was placed in the retrograde direction in the antecubital space and a fiber optic sensor (Paratrend, Diametrics Medical, Inc.) was placed through a 22 G catheter into the FDS muscle under ultrasound guidance. After a 45 min rest period, subjects performed three 5-min bouts of repetitive handgrip exercise (2s contraction/1 s relaxation) at attempted levels of 15%, 30% and 45% of maximal voluntary contraction. The order of the exercise bouts was random with the second and third bouts started after blood lactate had returned to baseline. Venous blood was sampled every minute during exercise and analyzed with an I-Stat CG-4+ cartridge, while IF fiber optic sensor measurements were obtained every 2 s. Change from pre-exercise baseline to end of exercise was computed for pH, PCO2 and PO2. Blood and IF values were compared with a paired t-test. RESULTS: Baseline values for pH, PCO2 and PO2 were 7.37+/-0.02, 46+/-4 mm Hg, and 36+/-6 mm Hg respectively in blood and 7.39+/-0.02, 44+/-6 mm Hg, and 35+/-14 mm Hg in IF. Average changes over all exercise levels are noted in the Table below. For each parameter the exercise-induced change was at least twice as great in IF as in blood. In blood and IF, pH and PCO2 increases were directly related to exercise intensity. Change in venous PO2 was unrelated to exercise intensity, while IF PO2 decreased with increases in exercise intensity. CONCLUSIONS: Measurement of IF pH, PCO2 and PO2 is more sensitive to exercise intensity than measurement of the same parameters in venous blood and provides continuous assessment during and after exercise.

Hagan, Ronald Donald↗

Gesture Based Control and EMG Decomposition

This paper presents two probabilistic developments for use with Electromyograms (EMG). First described is a new-electric interface for virtual device control based on gesture recognition. The second development is a Bayesian method for decomposing EMG into individual motor unit action potentials. This more complex technique will then allow for higher resolution in separating muscle groups for gesture recognition. All examples presented rely upon sampling EMG data from a subject's forearm. The gesture based recognition uses pattern recognition software that has been trained to identify gestures from among a given set of gestures. The pattern recognition software consists of hidden Markov models which are used to recognize the gestures as they are being performed in real-time from moving averages of EMG. Two experiments were conducted to examine the feasibility of this interface technology. The first replicated a virtual joystick interface, and the second replicated a keyboard. Moving averages of EMG do not provide easy distinction between fine muscle groups. To better distinguish between different fine motor skill muscle groups we present a Bayesian algorithm to separate surface EMG into representative motor unit action potentials. The algorithm is based upon differential Variable Component Analysis (dVCA) [l], [2] which was originally developed for Electroencephalograms. The algorithm uses a simple forward model representing a mixture of motor unit action potentials as seen across multiple channels. The parameters of this model are iteratively optimized for each component. Results are presented on both synthetic and experimental EMG data. The synthetic case has additive white noise and is compared with known components. The experimental EMG data was obtained using a custom linear electrode array designed for this study.

Wheeler, Kevin R.↗

Generating Control Commands From Gestures Sensed by EMG

An effort is under way to develop noninvasive neuro-electric interfaces through which human operators could control systems as diverse as simple mechanical devices, computers, aircraft, and even spacecraft. The basic idea is to use electrodes on the surface of the skin to acquire electromyographic (EMG) signals associated with gestures, digitize and process the EMG signals to recognize the gestures, and generate digital commands to perform the actions signified by the gestures. In an experimental prototype of such an interface, the EMG signals associated with hand gestures are acquired by use of several pairs of electrodes mounted in sleeves on a subject s forearm (see figure). The EMG signals are sampled and digitized. The resulting time-series data are fed as input to pattern-recognition software that has been trained to distinguish gestures from a given gesture set. The software implements, among other things, hidden Markov models, which are used to recognize the gestures as they are being performed in real time. Thus far, two experiments have been performed on the prototype interface to demonstrate feasibility: an experiment in synthesizing the output of a joystick and an experiment in synthesizing the output of a computer or typewriter keyboard. In the joystick experiment, the EMG signals were processed into joystick commands for a realistic flight simulator for an airplane. The acting pilot reached out into the air, grabbed an imaginary joystick, and pretended to manipulate the joystick to achieve left and right banks and up and down pitches of the simulated airplane. In the keyboard experiment, the subject pretended to type on a numerical keypad, and the EMG signals were processed into keystrokes. The results of the experiments demonstrate the basic feasibility of this method while indicating the need for further research to reduce the incidence of errors (including confusion among gestures). Topics that must be addressed include the numbers and arrangements of electrodes needed to acquire sufficient data; refinements in the acquisition, filtering, and digitization of EMG signals; and methods of training the pattern- recognition software. The joystick and keyboard simulations were chosen for the initial experiments because they are familiar to many computer users. It is anticipated that, ultimately, interfaces would utilize EMG signals associated with movements more nearly natural than those associated with joysticks or keyboards. Future versions of the pattern-recognition software are planned to be capable of adapting to the preferences and day-today variations in EMG outputs of individual users; this capability for adaptation would also make it possible to select gestures that, to a given user, feel the most nearly natural for generating control signals for a given task (provided that there are enough properly positioned electrodes to acquire the EMG signals from the muscles involved in the gestures).

Wheeler, Kevin R.↗

NASA Tech Briefs, March 2005

Topics covered include: Scheme for Entering Binary Data Into a Quantum Computer; Encryption for Remote Control via Internet or Intranet; Coupled Receiver/Decoders for Low-Rate Turbo Codes; Processing GPS Occultation Data To Characterize Atmosphere; Displacing Unpredictable Nulls in Antenna Radiation Patterns; Integrated Pointing and Signal Detector for Optical Receiver; Adaptive Thresholding and Parameter Estimation for PPM; Data-Driven Software Framework for Web-Based ISS Telescience; Software for Secondary-School Learning About Robotics; Fuzzy Logic Engine; Telephone-Directory Program; Simulating a Direction-Finder Search for an ELT; Formulating Precursors for Coating Metals and Ceramics; Making Macroscopic Assemblies of Aligned Carbon Nanotubes; Ball Bearings Equipped for In Situ Lubrication on Demand; Synthetic Bursae for Robots; Robot Forearm and Dexterous Hand; Making a Metal-Lined Composite-Overwrapped Pressure Vessel; Ex Vivo Growth of Bioengineered Ligaments and Other Tissues; Stroboscopic Goggles for Reduction of Motion Sickness; Articulating Support for Horizontal Resistive Exercise; Modified Penning-Malmberg Trap for Storing Antiprotons; Tumbleweed Rovers; Two-Photon Fluorescence Microscope for Microgravity Research; Biased Randomized Algorithm for Fast Model-Based Diagnosis; Fast Algorithms for Model-Based Diagnosis; Simulations of Evaporating Multicomponent Fuel Drops; Formation Flying of Tethered and Nontethered Spacecraft; and Two Methods for Efficient Solution of the Hitting- Set Problem.

Source record↗

Sensory-Feedback Exoskeletal Arm Controller

An electromechanical exoskeletal arm apparatus has been designed for use in controlling a remote robotic manipulator arm. The apparatus, called a force-feedback exoskeleton arm master (F-EAM) is comfortable to wear and easy to don and doff. It provides control signals from the wearer s arm to a robot arm or a computer simulator (e.g., a virtual-reality system); it also provides force and torque feedback from sensors on the robot arm or from the computer simulator to the wearer s arm. The F-EAM enables the wearer to make the robot arm gently touch objects and finely manipulate them without exerting excessive forces. The F-EAM features a lightweight design in which the motors and gear heads that generate force and torque feedback are made smaller than they ordinarily would be: this is achieved by driving the motors to power levels greater than would ordinarily be used in order to obtain higher torques, and by providing active liquid cooling of the motors to prevent overheating at the high drive levels. The F-EAM (see figure) includes an assembly that resembles a backpack and is worn like a backpack, plus an exoskeletal arm mechanism. The FEAM has five degrees of freedom (DOFs) that correspond to those of the human arm: 1. The first DOF is that of the side-to-side rotation of the upper arm about the shoulder (rotation about axis 1). The reflected torque for this DOF is provided by motor 1 via drum 1 and a planar four-bar linkage. 2. The second DOF is that of the up-and-down rotation of the arm about the shoulder. The reflected torque for this DOF is provided by motor 2 via drum 2. 3. The third DOF is that of twisting of the upper arm about its longitudinal axis. This DOF is implemented in a cable remote-center mechanism (CRCM). The reflected torque for this DOF is provided by motor 3, which drives the upper-arm cuff and the mechanism below it. A bladder inflatable by gas or liquid is placed between the cuff and the wearer s upper arm to compensate for misalignment between the exoskeletal mechanism and the shoulder. 4. The fourth DOF is that of flexion and extension of the elbow. The reflected torque for this DOF is provided by motor 4 and drum 4, which are mounted on a bracket that can slide longitudinally by a pin-and-slot engagement with the upper-arm cuff to compensate for slight variations in the position of the kinematic center of the elbow. Attached to drum 4 is an adapter plate to which is attached a CRCM for the lower arm. 5. The lower-arm CRCM implements the fifth DOF, which is the twist of the forearm about its longitudinal axis. Motor 5 provides the reflected torque for this DOF by driving the lower-arm cuff. A rod transmits twist and torsion between the lower-arm cuff and the hand cuff. With this system, the motion of the wearer s joints and the reflected torques applied to these joints can be measured and controlled in a relatively simple manner. This is because the anthropomorphic design of the mechanism imitates the kinematics of the human arm, eliminating the need for kinematic conversion of joint-torque and joint-angle data.

An, Bin↗

The Robonaut 2 Hand - Designed to do Work with Tools

The second generation Robonaut hand has many advantages over its predecessor. This mechatronic device is more dexterous and has improved force control and sensing giving it the capability to grasp and actuate a wider range of tools. It can achieve higher peak forces at higher speeds than the original. Developed as part of a partnership between General Motors and NASA, the hand is designed to more closely approximate a human hand. Having a more anthropomorphic design allows the hand to attain a larger set of useful grasps for working with human interfaces. Key to the hand s improved performance is the use of lower friction drive elements and a redistribution of components from the hand to the forearm, permitting more sensing in the fingers and palm where it is most important. The following describes the design, mechanical/electrical integration, and control features of the hand. Lessons learned during the development and initial operations along with planned refinements to make it more effective are presented.

Bridgwater, L. B.↗

Using Arm and Hand Gestures to Command Robots during Stealth Operations

Command of support robots by the warfighter requires intuitive interfaces to quickly communicate high degree-of-freedom (DOF) information while leaving the hands unencumbered. Stealth operations rule out voice commands and vision-based gesture interpretation techniques, as they often entail silent operations at night or in other low visibility conditions. Targeted at using bio-signal inputs to set navigation and manipulation goals for the robot (say, simply by pointing), we developed a system based on an electromyography (EMG) "BioSleeve", a high density sensor array for robust, practical signal collection from forearm muscles. The EMG sensor array data is fused with inertial measurement unit (IMU) data. This paper describes the BioSleeve system and presents initial results of decoding robot commands from the EMG and IMU data using a BioSleeve prototype with up to sixteen bipolar surface EMG sensors. The BioSleeve is demonstrated on the recognition of static hand positions (e.g. palm facing front, fingers upwards) and on dynamic gestures (e.g. hand wave). In preliminary experiments, over 90% correct recognition was achieved on five static and nine dynamic gestures. We use the BioSleeve to control a team of five LANdroid robots in individual and group/squad behaviors. We define a gesture composition mechanism that allows the specification of complex robot behaviors with only a small vocabulary of gestures/commands, and we illustrate it with a set of complex orders.

stealth operations↗

Biospecimen Retrieval from NASA's Rodent Research-1: Maximizing Science Return from Flight Missions

Rodent Research (RR)-1 was conducted to validate flight hardware, operations, and science capabilities that were developed to support long duration missions on the International Space Station. After 37 days in microgravity twenty mice were euthanized and frozen on orbit. Upon return to Earth the carcasses were dissected and yielded 32 different types of tissues from each mouse and over 3200 tissue aliquots. Many tissues were distributed to the Space Life and Physical Sciences (SLPS) Biospecimen Sharing Program (BSP) Principal Investigators (PIs) through the Ames Life Science Data Archive (ALSDA). A second round of dissections was performed to collect additional tissues from the remaining carcasses thawed for a second time for additional BSP PIs. Tissues retrieved included vaginal walls, aorta, pelvis, brown adipose tissue, tail, spine and forearms. Although the analyses are still in progress, some of the PIs have reported that the quality of the tissues was acceptable for their study. In a separate experiment we tested the RNA quality of the tissues that were dissected from frozen carcasses that were subjected to euthanasia, freezing, first and second thaw dissections. Timelines simulated the on-orbit RR-1 procedures to assess the quality of the tissues retrieved from the second thaw dissections. We analyzed the RIN values of select tissues including kidney, brain, white adipose tissue (WAT) and brown adipose tissue (BAT). Overall the RIN values from the second thaw were lower compared to those from the first by about a half unit; however, the tissues yielded RNA that are acceptable quality for some quantitative gene expression assays. Interestingly, RIN values of brain tissues were 8.4+/-0.6 and 7.9+/-0.7 from first and second round dissections, respectively (n=5). Kidney and WAT yielded RIN values less than 8 but they can still be used for qPCR. BAT yielded higher quality RNA (8.2+/-0.5) than WAT (5.22+/-0.9), possibly due to the high fat content. Together, these data show that select tissues can be utilized for gene expression studies even if they are retrieved from carcasses that were subjected to at least two freezing and thawing processes; this further expands science return from valuable and infrequent rodent experiments in space.

rodent↗

Biospecimen Retrieval from NASA's Rodent Research-1: Maximizing Science Return from Flight Missions

Rodent Research (RR)-1 was conducted to validate flight hardware, operations, and science capabilities that were developed to support long duration missions on the International Space Station. After 37 days in microgravity twenty mice were euthanized and frozen on orbit. Upon return to Earth the carcasses were dissected and yielded 32 different types of tissues from each mouse and over 3200 tissue aliquots. Many tissues were distributed to the Space Life and Physical Sciences (SLPS) Biospecimen Sharing Program (BSP) Principal Investigators (PIs) through the Ames Life Science Data Archive (ALSDA). A second round of dissections was performed to collect additional tissues from the remaining carcasses thawed for a second time for additional BSP PIs. Tissues retrieved included vaginal walls, aorta, pelvis, brown adipose tissue, tail, spine and forearms. Although the analyses are still in progress, some of the PIs have reported that the quality of the tissues was acceptable for their study. In a separate experiment we tested the RNA quality of the tissues that were dissected from frozen carcasses that were subjected to euthanasia, freezing, first and second thaw dissections. Timelines simulated the on-orbit RR-1 procedures to assess the quality of the tissues retrieved from the second thaw dissections. We analyzed the RIN values of select tissues including kidney, brain, white adipose tissue (WAT) and brown adipose tissue (BAT). Overall the RIN values from the second thaw were lower compared to those from the first by about a half unit; however, the tissues yielded RNA that are acceptable quality for some quantitative gene expression assays. Interestingly, RIN values of brain tissues were 8.4+/-0.6 and 7.9+/-0.7 from first and second round dissections, respectively (n5). Kidney and WAT yielded RIN values less than 8 but they can still be used for qPCR. BAT yielded higher quality RNA (8.2+/-0.5) than WAT (5.2+/-20.9), possibly due to the high fat content. Together, these data show that select tissues can be utilized for gene expression studies even if they are retrieved from carcasses that were subjected to at least two freezing and thawing processes; this further expands science return from valuable and infrequent rodent experiments in space.

rodents↗

Results from InSight Robotic Arm Activities

The InSight lander carried an Instrument Deployment System (IDS) that included an Instrument Deployment Arm (IDA), scoop, five finger “claw” grapple, forearm-mounted Instrument Deployment Camera (IDC) requiring arm motion to image a target, and landermounted Instrument Context Camera (ICC), designed to image the workspace, and to place the instruments onto the surface. As originally proposed, the IDS included a previously built arm and flight spare black and white cameras and had no science objectives or requirements, or expectation to be used after instrument deployment (90 sols). During project development the detectors were upgraded to color, and it was recognized that the arm could be used to carry out a wide variety of activities that would enable both geology and physical properties investigations. During surface operations for two martian years, the IDA was used during major campaigns to image the surface around the lander, to deploy the instruments, to assist the mole in penetrating beneath the surface, to bury a portion of the seismometer tether, to clean dust from the solar arrays to increase power, and to conduct a surface geology investigation including soil mechanics and physical properties experiments. No other surface mission has engaged in such a sustained and varied campaign of arm and scoop activities directed at such a diverse suite of objectives. Images close to the surface and continuous meteorology measurements provided important constraints on the threshold friction wind speed needed to initiate aeolian saltation and surface creep. The IDA was used extensively for almost 22 months to assist the mole in penetrating into the subsurface. Soil was scraped into piles and dumped onto the seismometer tether six times in an attempt to bury the tether and ∼ 30% was entrained in the wind and dispersed downwind 1-2 m, darkening the surface. Seven solar array cleaning experiments were conducted by dumping scoops of soil from 35 cm above the lander deck during periods of high wind that dispersed the sand onto the panels that kicked dust off of the panels into suspension in the atmosphere, thereby increasing the power by ∼15% during this period. Final IDA activities included an indentation experiment that used the IDA scoop to push on the ground to measure the plastic deformation of the soil that complemented soil mechanics measurements from scoop interactions with the surface, and two experiments in which SEIS measured the tilt from the arm pressing on the ground to derive near surface elastic properties.

Mars↗

A Crew Seat for Human Exploration in Multiple Gravity Environments

This work attempts to develop a single crew seating solution that is applicable across a range of gravity environments encountered by spacecraft proposed in several conceptual spacecraft architectures. All of these spacecraft will need to provide some sort of stationary accommodation for the crew for performing various activities such as work in science laboratories, maintenance and repair facilities, medical care facilities, and spacecraft operations centers, as well as for basic habitation in crew quarters, entertainment / relaxation facilities, and crew dining facilities. Depending on the spacecraft or architecture, this stationary accommodation may be experienced continuously in microgravity, such as would be the case for the Deep Space Exploration Vehicle. Alternately, it could be in continuous lunar or Martian gravity, such as the Common Habitat base camps. It could experience fractional gravity, such as a Pressurized Rover for In-Space Missions at a Near Earth Asteroid or one of the Martian moons. It could alternate between artificial gravity and microgravity, such as the Nautilus-X. It could alternate between microgravity and lunar or Martian gravity, such as the SpaceX Starship Human Landing System or the Blue Origin Blue Moon Block 2 Human Landing System. Or it could be in continuous Earth gravity, such as ground trainer systems. Prior human spaceflight systems for stationary accommodation have been focused on microgravity applications. These systems have their own limitations and cannot be used in a gravity environment. A public crowdsourcing campaign generated dozens of ideas, which ultimately generated a Gecko Mobility Aids system for crew translation and the Multi-Gravity Crew Seat (MGCS) for stationary accommodation. The MGCS functions in gravity as a traditional terrestrial seat, performing functions of load for the overall body and forearms, as well as head and neck load relief while positioning the body within range of an intended task. In microgravity, the MGCS functions as a body restraint, securing the body against inadvertent drifting by applying a restraining pressure at the front and back of the thighs, shoulders, and back. The initial MGCS concept was developed in a NASA hackathon and was refined through a review of dozens of terrestrial seating styles. Additionally, a review of anthropometry and biomechanics data related to the neutral body posture was conducted to help inform the microgravity configuration of the MGCS. A series of CAD models were iteratively developed, with subject matter expert reviews leading to design improvements. A scale model was constructed and used with a humanoid model to demonstrate MGCS accommodation of a human-like body in both gravity and microgravity modes. Work to develop a full-scale protype of the MGCS is discussed, including design and fabrication of the headrest, arm rest, seat back, seat pan, seat base, and the conversion mechanisms. A 1-g human-in-the-loop evaluation of the prototype assessed the acceptability of performing seated activities in the MGCS, collecting data on the usability, comfort, and ease of ingress/egress. Based on the evaluation results, design modifications needed for reduced gravity testing are documented and initial work is indicated for a reduced gravity test plan.

Restraints and Mobility Aids↗

Optical switches and switching methods

A device and method for collecting subject responses, particularly during magnetic imaging experiments and testing using a method such as functional MRI. The device comprises a non-metallic input device which is coupled via fiber optic cables to a computer or other data collection device. One or more optical switches transmit the subject's responses. The input device keeps the subject's fingers comfortably aligned with the switches by partially immobilizing the forearm, wrist, and/or hand of the subject. Also a robust nonmetallic switch, particularly for use with the input device and methods for optical switching.

47 OTHER INSTRUMENTATION↗

Critical Dose of Internal Organs Internal Exposure - 13471

The health threat posed by radionuclides has stimulated increased efforts to developed characterization on the biological behavior of radionuclides in humans in all ages. In an effort motivated largely by the Chernobyl nuclear accident, the International Commission on Radiological Protection (ICRP) is assembling a set of age specific biokinetic models for environmentally important radioelements. Radioactive substances in the air, mainly through the respiratory system and digestive tract, is inside the body. Radioactive substances are unevenly distributed in various organs and tissues. Therefore, the degree of damage will depend not only on the dose of radiation have but also on the critical organ, which is the most accumulation of radioactive substances, which leads to the defeat of the entire human body. The main objective of radiation protection, to avoid exceeding the maximum permissible doses of external and internal exposure of a person to prevent the physical and genetic damage people. The maximum tolerated dose (MTD) of radiation is called a dose of radiation a person in uniform getting her for 50 years does not cause changes in the health of the exposed individual and his progeny. The following classification of critical organs, depending on the category of exposure on their degree of sensitivity to radiation: First group: the whole body, gonads and red bone marrow; Second group: muscle, fat, liver, kidney, spleen, gastrointestinal tract, lungs and lens of the eye; The third group: bone, thyroid and skin; Fourth group: the hands, forearms, feet. MTD exposure whole body, gonads and bone marrow represent the maximum exposures (5 rem per year) experienced by people in their normal activities. The purpose of this article is intended dose received from various internal organs of the radionuclides that may enter the body by inhalation, and gastrointestinal tract. The biokinetic model describes the time dependent distribution and excretion of different radionuclides that have intake into the organism or absorbed into blood. Transport of different radionuclides between compartments is assumed to follow first order kinetics provided the concentration in red blood cells (RBCs) stays below a nonlinear threshold concentration. When the concentration in RBCs exceeds that threshold, the transfer rate from diffusible plasma to RBCs is assumed to decrease as the concentration in RBCs increases. For the calculations used capabilities AMBER by using the traces of radionuclides in the body. Model for the transfer of radionuclides in the body has been built on the basis of existing models at AMBER for lead. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Soft Robotic Glove System for Wearable Haptic Teleoperation - 18373

Managing nuclear waste is a difficult, dangerous, and costly task. Teleoperation of robotic operators is an important functionality for this application, allowing robotic devices to operate in dangerous environments while still leveraging the existing abilities and technical knowledge of human workers. One difficulty in implementing effective teleoperation systems is that human operators rely on more senses beside sight: in particular, touch. The sense of touch could provide significant benefits for teleoperation, preventing environmental mishaps that could cost millions of dollars. To help remedy this problem, we present a soft haptic feedback glove system. The primary functionality of this system is to provide tactile and force feedback on the user's hands. This was achieved using custom cylindrical pneumatic actuators. These actuators consist of plastic sheeting folded into a hollow-walled cylinder which is connected to a pressure source. When pressurized, the cylinder walls expand and the cylinder straightens, with the force being related to the pressure. The glove system has one of these actuators over each of the user's three main fingers (index, middle, and thumb), where pressurizing the actuator applies a reaction force to the finger of the user, mimicking the resistance of a grasped object. The expansion of these actuators also causes them to physically press against the user's fingers, giving them the feeling of contact. To demonstrate the usability of this system, we implemented a virtual environment in V-REP simulating the interactions between a robotic Jaco Arm and a floating ball. This simulation receives hand and figure positions from the haptic glove and used them to drive the state of the simulated Jaco Arm. In response to the interactions between the Jaco and the floating ball, the simulation returns commands to the glove, instructing it to pressurize or depressurize its actuators as appropriate, allowing the user to feel the ball in their hand. We tested users in their ability to prevent the ball from floating away using this system with and without the haptic feedback. Results show that the addition of haptic feedback significantly improved the ability of users to interact precisely with the environment. We also used the finger positions of the haptic glove to control a physical robotic hand, and demonstrated the system's usability for control of real robots, though the lack of sensors on the robot made providing the tactile feedback impractical. However, there is more to grasping and holding an object than just the feeling of contact and the resistance to closing one's hand. The weight of the object will apply forces to the user's other joints as they hold it. To this end, we added a haptic feedback device for the user's wrist, a technique that can be generalized to the user's other joints. This is made up of reverse Pneumatic Artificial Muscles (rPAMs) stretching across the wrist between mounts on the hand and forearm. These rPAM actuators are tubes of silicone wrapped in thread such that they extend when pressurized. This extension can apply torque on the user's wrist, mimicking the feeling of gravity, or allowing the simulation of additional contact forces (such as the user's hand impacting an object). We tested this wrist device independently using a simulated path-following experiment. Users showed a significant improvement in performance when aided by haptic feedback during sinusoidal path experiments, demonstrating the usability of this approach. We then integrated the two systems, further demonstrating the usability of this approach. This project represents the first step towards a more effective robotic teleoperation system, allowing skilled human workers to perform tasks more effectively while remaining out of danger. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗