Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAS SCINTILLATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Investigation of Deuterium Loaded Materials Subject to X-Ray Exposure

Results are presented from an exploratory study involving x-ray irradiation of select deuterated materials. Titanium deuteride plus deuterated polyethylene, deuterated polyethylene alone, and for control, hydrogen-based polyethylene samples and nondeuterated titanium samples were exposed to x-ray irradiation. These samples were exposed to various energy levels from 65 to 280 kV with prescribed electron flux from 500 to 9000 μA impinging on a tungsten braking target, with total exposure times ranging from 55 to 280 min. Gamma activity was measured using a high-purity germanium (HPGe) detector, and for all samples no gamma activity above background was detected. Alpha and beta activities were measured using a gas proportional counter, and for select samples beta activity was measured with a liquid scintillator spectrometer. The majority of the deuterated materials subjected to the microfocus x-ray irradiation exhibited postexposure beta activity above background and several showed short-lived alpha activity. The HPE and nondeuterated titanium control samples exposed to the x-ray irradiation showed no postexposure alpha or beta activities above background. Several of the samples (SL10A, SL16, SL17A) showed beta activity above background with a greater than 4σ confidence level, months after exposure. Portions of SL10A, SL16, and SL17A samples were also scanned using a beta scintillator and found to have beta activity in the tritium energy band, continuing without noticeable decay for over 12 months. Beta scintillation investigation of as-received materials (before x-ray exposure) showed no beta activity in the tritium energy band, indicating the beta emitters were not in the starting materials.

x-ray irradiation↗

Results from the XENON10 Dark Matter search experiment at Gran Sasso Laboratories

One of the most appealing questions in astroparticle physics concerns the nature of the Dark Matter (DM) particles and their possible interaction with ordinary matter. In order to find a solution to such problem, a double phase liquid-gas Xenon Time Projection Chamber has been proposed and built as a suitable detector for the direct detection of DM in the form of Weakly Interacting Massive Particles (WIMPs). The possibility of simultaneously measuring the scintillation and the ionization signals, and a 3D event localization feature, represent a powerful background discrimination method. During the Autumn-Winter 2006-2007 a prototype of 15 kg sensitive mass of Liquid Xenon (XENON10) has been successfully run at the Gran Sasso Underground Laboratory. The technique and the results of the XENON10 detector are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fission neutron spectra measurements at LANSCE - status and plans

A program to measure fission neutron spectra from neutron-induced fission of actinides is underway at the Los Alamos Neutron Science Center (LANSCE) in a collaboration among the CEA laboratory at Bruyeres-le-Chatel, Lawrence Livermore National Laboratory and Los Alamos National Laboratory. The spallation source of fast neutrons at LANSCE is used to provide incident neutron energies from less than 1 MeV to 100 MeV or higher. The fission events take place in a gas-ionization fission chamber, and the time of flight from the neutron source to that chamber gives the energy of the incident neutron. Outgoing neutrons are detected by an array of organic liquid scintillator neutron detectors, and their energies are deduced from the time of flight from the fission chamber to the neutron detector. Measurements have been made of the fission neutrons from fission of {sup 235}U, {sup 238}U, {sup 237}Np and {sup 239}Pu. The range of outgoing energies measured so far is from 1 MeV to approximately 8 MeV. These partial spectra and average fission neutron energies are compared with evaluated data and with models of fission neutron emission. Results to date will be presented and a discussion of uncertainties will be given in this presentation. Future plans are to make significant improvements in the fission chambers, neutron detectors, signal processing, data acquisition and the experimental environment to provide high fidelity data including mea urements of fission neutrons below 1 MeV and improvements in the data above 8 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Background Simulation of the MSFC GSPC Balloon Payload

Numerical simulations are used to predict the cosmic-ray induced background in a passively shielded gas scintillation proportional counter to be used as the focal plane instrument of a balloon-borne hard x-ray telescope system. The predicted background in the 20-75 keV operating range of the detector shows a spectral shape characteristic of a power law photoelectrically absorbed by the stainless steel pressure vessel walls. It is found that the dominant background radiation component is simply cosmic diffuse and atmospheric gamma-ray leakage though there is a contribution from nuclear interactions of energetic particles in the walls and nearby payload structures. The correlation between shielding properties and background flux is examined parametrically using one-dimensional slab models, within material and weight constraints, in order to optimize predicted sensitivity. The addition of a few mm thick Sn passive shielding reduces the primary photon contribution by up to 50% at the spectral peak, E 150 keV, and adds only negligibly to the flux due to photon production within the high-Z shields at lower energies.

Swartz, D. A.↗

Nuclear Science Symposium, 29th, and Symposium on Nuclear Power, 14th, Washington, DC, October 20-22, 1982, Proceedings

High-energy radiation detectors suitable for balloon-borne or space-based radiation event studies are described. The employment of NaI(Tl) scintillator bars for gamma ray detection is outlined, and the development of a fluorescent gated gas-filled scintillation proportional counter is reported. A high throughput nondispersive hard X ray spectrograph with angular resolution for cosmic bursts, transients, and sources has been constructed. Features of a sealed high pressure xenon filled imaging proportional counter with a 30 sq cm sensitive area are explored. Finally, the various radiation effects on electronic circuitry in a space environment are defined, and an MOS dosimeter for assaying the cumulative radiation flux in a spacecraft due to ambient conditions is characterized.

Davis, W. D.↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time and Energy Characterization of a Neutron time of Flight Detector for Re-designing Line of Sight 270 at the Z Pulsed Power Facility.

This work will focus on the characterization of NTOF detectors fielded on ICF experiments conducted at the Z-experimental facility with emphasis on the MagLif and gas puff campaigns. Three experiments have been proposed. The first experiment will characterize the response of the PMT with respect to the amplitude and width of signals produced by single neutron events. A second experiment will characterize the neutron transit time through the scintillator and the third is to characterize the pulse amplitude for a very specific range of neutron induced charged particle interactions within the scintillator. These experiments will cover incident neutron energies relevant to D-D and D-T fusion reactions. These measurements will be taken as a function of detector bias to cover the entire dynamic range of the detector. Throughout the characterization process, the development of a predictive capability is desired. A new post processing code has been proposed that will calculate a neutron time-of-flight spectrum in units of MeVee. This code will couple the experimentally obtained values and the results obtained with the Monte Carlo code MCNP6. The motivation of this code is to correct for geometry issues when transferring the calibration results from a light lab setting to the Zenvironment. This capability will be used to develop a hypothetical design of LOS270 such that more favorable neutron measurements, requiring less correction, can be made in the future.

47 OTHER INSTRUMENTATION↗

An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV/nucleon

A balloon-borne instrument system for the study of cosmic ray composition in the energy region beyond 100 GeV/nucleon is described. The large area detector incorporates an ionization spectrometer or calorimeter to determine the energy of the incident particles which is calibrated in flight by a gas Cerenkov counter filled with freon 12 at 20 psi. Calibration of calorimeter response indicates that the effects of ionization energy loss and nucleon fragmentation are correctly accounted for in a Monte Carlo simulation. A charge measuring module consisting of five scintillators and a lucite Cerenkov counter is used to determine the charge and position of the incoming particles. A spatial resolution of 5 to 10 cm has been obtained by using the ratios of pulse heights in different photomultiplier tubes aimed at the same scintillators within the module. The detector represents the heaviest cosmic ray experiment that can be flown over 30 km using the dynamic launching technique commonly employed.

Arens, J. F.↗

A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector

We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. Finally, an infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable’s motion, and the system was controlled via a graphical user interface.

42 ENGINEERING↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coated Fiber Neutron Detector Test

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Reported here are the results of tests of the 6Li/ZnS(Ag)-coated non-scintillating plastic fibers option. This testing measured the required performance for neutron detection efficiency and gamma ray rejection capabilities of a system manufactured by Innovative American Technology (IAT).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hard X-ray astrophysics

Past hard X-ray and lower energy satellite instruments are reviewed and it is shown that observation above 20 keV and up to hundreds of keV can provide much valuable information on the astrophysics of cosmic sources. To calculate possible sensitivities of future arrays, the efficiencies of a one-atmosphere inch gas counter (the HEAO-1 A-2 xenon filled HED3) and a 3 mm phoswich scintillator (the HEAO-1 A-4 Na1 LED1) were compared. Above 15 keV, the scintillator was more efficient. In a similar comparison, the sensitivity of germanium detectors did not differ much from that of the scintillators, except at high energies where the sensitivity would remain flat and not rise with loss of efficiency. Questions to be addressed concerning the physics of active galaxies and the diffuse radiation background, black holes, radio pulsars, X-ray pulsars, and galactic clusters are examined.

Rothschild, R. E.↗

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

Soleti, S. R. [Donostia Intl. Phys. Ctr., San Seba↗

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The UA9 experimental layout

The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode. Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam. Scintillators, Gas Electron Multiplier chambers and other beam loss monitors measure nuclear loss rates induced by the interaction of the beam halo in the crystal. Two Roman pots installed in the path of the deflected particles are equipped with a Medipix detector to reconstruct the transverse distribution of the impinging beam. Finally UA9 takes advantage of an LHC-collimator prototype installed close to the first Roman pot to help in setting the beam conditions and to analyze the efficiency to deflect the beam. This paper describes in details the hardware installed to study the crystal collimation during 2010.

43 PARTICLE ACCELERATORS↗

SU-F-T-73: Experimental Determination of the Effective Point of Measurement in Electron Beams Using a Commercial Scintillation Detector

Purpose: The aim of this work was to determine experimentally the effective point of measurement (EPOM) in clinical electron beams for three cylindrical ionization chambers using a commercial scintillation detector as a reference detector. Methods: Percent depth dose (PDD) curves were measured using an Exradin W1 scintillation detector and were used as a representative PDD to water. Depth dose curves were measured with the Exradin A18, A1SL, and A28 ionization chambers. The raw ionization chamber curve data were corrected by the chamber fluence perturbation correction factor and restricted mass collisional stopping power ratio at each depth to obtain a percent depth dose curve to the gas volume (PDDGV) of the detector. Ratios of the W1 PDD to the ion chamber PDDGV were calculated for each measurement depth. The W1 PDD curve was shifted by small depth increments, Δz, until the ratio of the W1 PDD to the ion chamber PDDGV was depth-independent (optimal Δz). A MATLAB routine was developed to determine the optimal Δz value. Results: The optimal Δz shift was used as an estimate of the EPOM for each chamber. The average calculated EPOM shifts (expressed as a fraction of the chamber cavity radius) for the A18, A1SL, and A28 ionization chambers were 0.21 ± 0.04, 0.10 ± 0.05, and 0.22 ± 0.03, respectively. Conclusion: The experimentally determined EPOM values for the A18 and A1SL in this work agreed with the simulated values of Muir and Rogers (MedPhys 2014). The results also indicate that the Exradin W1 scintillator is water equivalent for electron energies of 6 MeV, 9 MeV, 12 MeV, and 16 MeV. In addition, we confirmed that the AAPM TG51 recommended EPOM shift of 0.5 times the cavity radius is not accurate for the A18 and A1SL chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

Measurement and analysis of energy and angular distributions of thick target neutron yields from 110 MeV {sup 19}F on {sup 27}Al

Energy distributions of emitted neutrons were measured for 110 MeV {sup 19}F ions incident on a thick {sup 27}Al target. Measurements were done at 0 deg., 30 deg., 60 deg., 90 deg., and 120 deg. with respect to the projectile direction employing the time-of-flight technique using a proton recoil scintillation detector. Comparison with calculated results from equilibrium nuclear reaction model codes like PACE-2 and EMPIRE 2.18 using various level-density options was carried out. It is observed that the dynamic level-density approach in EMPIRE 2.18 gives the closest approximation to the measured data. In the Fermi-gas level-density approach the best approximation of the level-density parameter is a=A/12.0, where A is the mass number of the composite system. The trend in the angular distribution of emitted neutrons is well reproduced by the projection of the angular momentum on the recoil axis as done in the PACE-2 code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗