Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Ray Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

Performance of the AstroPix Prototype Module for the Barrel Imaging Calorimeter at the ePIC Detector and in Space-Based Payloads

AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor originally developed to enable precision gamma-ray imaging and spectroscopy in the medium-energy regime (~100 keV–100 MeV) based on the groundwork laid by ATLASpix and MuPix. It features a 500 μm pixel pitch, in-pixel amplification and digitization, and low power consumption (~3-4 mW/cm2), making it scalable for large-area, multilayer telescope detector planes. The detectors have a designed dynamic range of 25 keV to 700 keV. With these features, AstroPix meets the requirements of future space-based high-energy telescopes and the imaging layers of the Barrel Imaging Calorimeter (BIC) in the Electron-Proton/Ion Collider (ePIC) detector at the future Electron-Ion Collider (EIC). For the space-based payload, AstroPix is being integrated into sounding rocket and balloon payloads to demonstrate the technical readiness of the devices. For BIC, AstroPix-based imaging layers interleaved within the lead/scintillating-fiber (Pb/SciFi) sampling calorimeter provide granular shower imaging, enabling key performance features such as electron/pion or gamma/neutral pion separation. As part of the ongoing detector R&D efforts, we have been testing various AstroPix_v3 configurations: the single chip, a quad-chip assembly, a three-layer stack of quad chips, and a 9-chip module that represents the smallest prototype unit of the BIC imaging layer. This presentation will highlight recent performance test results from these AstroPix detector configurations.

Kim, Bobae (ORCID:0000000295396815)↗

X-ray escape peaks in gamma-ray spectrum acquired by perovskite detector

The X-ray escape peaks are clearly visible in the high-resolution gamma spectra acquired by CsPbBr 3 , credit to the rapidly improving energy resolution of perovskite gamma detectors. But it also raises concerns. If this peak remains as significant as it is, perovskite gamma detectors would have very limited use in complex gamma spectrometry applications. This paper discusses the origin of the escape peaks in CsPbBr 3 detectors, benchmarked against Ge and CZT detectors. The Pb escape peak consists of four escape peaks that are merged together, while the Cs and Br escape peaks are hidden inside the photopeak of 137 Cs (662 keV). These combined effects either create a noticeable gamma peak observed to the left of the 662 keV photopeak when acquired using a high-resolution CsPbBr 3 detector or raise the left slope of the photopeak. We also explore potential methods to mitigate these peaks, such as applying anti-coincidence method. The height of the escape peaks diminishes as the detector volume increases but will not go away entirely. The relationship between the observed Pb escape peak and the detector's dimensions is demonstrated through Monte Carlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geant4 based positron beam source (GPos) v1.0

GPos is a software that was created to determine the properties of positron beams resulting from the interaction of the LBNL BELLA center PetaWatt laser-driven plasma-capillary accelerated electron beam and the atoms of a thin solid target. GPos is written in C++, easily compiled with cmake and the spack package manager, which allows for multi-thread and MPI parallel computing. Its functions expand on the Geant4 toolkit library and allow for propagation of the modelled particles through vacuum drift distances with a focusing element (thin lens approximation). Users can change beam-foil-drift-lens parameters - to adapt GPos to other particle sources and infrastructures - in a simple input file. The code particle data output format, openPMD, which is compatible, for example, with the input of the ECP WarpX project code used to explore the physics of particle acceleration in plasmas. Using GPos in conjunction to WarpX allowed us to test various configurations for designing a high-quality and high-energy positron source at BELLA -required for us to address positron acceleration challenges in the development of future linear colliders. GPos can also be advantageous when tackling the physics of muon sources for future muon colliders as well as for the investigation of positron sources in lower energy regimes for applications like annihilation spectroscopy and astrophysical gamma-ray-bursts.

Pinto de Almeida Amorim, Ligia↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗

Steam-Assisted Ammonolysis of MoO2 as a Synthetic Pathway to Oxygenated δ-MoN

A common route for the synthesis of molybdenum nitrides is through the temperature-programmed reaction of molybdenum oxides with NH3, or ammonolysis. In this work, the role of precursor phase, gas phase chemistry (impact of H2O), and temperature profile on the reaction outcome (700 °C) was examined, which resulted in varying amounts of MoO2, H2MoO5, and the nitride phases—cubic γ (nominally Mo2N) and hexagonal δ (nominally MoN). The phase fraction of the δ phase increased with precursor in the sequence MoO2 > MoO3 > H2MoO5. Steam in the reaction gas also favored the production of δ over γ, but with too much steam, MoO2 was obtained in the product. Synthesis conditions for obtaining nearly phase-pure δ were identified: MoO2 as the precursor, 2% H2O in the gas stream, and a moderate heating rate (3 °C/min). In situ X-ray diffraction provided insights into the reaction pathway. Extensive physico-chemical analysis of the δ phase, including synchrotron X-ray and neutron diffraction, electron microscopy, thermogravimetric analysis, X-ray photoelectron spectroscopy, and prompt gamma activation analysis, revealed its stoichiometry to be MoO0.108(8)N0.892(8)H0.012(5), indicating non-trivial oxygen incorporation. The presence of N/O ordering and an impurity phase Mo5N6 were also revealed, detectable only by neutron diffraction. Notably, a computationally predicted MoON phase (doi: 10.1103/PhysRevLett.123.236402), of interest due to its potential to display a metal-insulator transition, did not appear under any reaction condition examined.

Pandey, Shobhit↗

An analysis of gamma-ray data collected at traffic intersections in Northern Virginia

Gamma-ray spectral data were collected from sensors mounted to traffic signals around Northern Virginia. The data were collected over a span of approximately fifteen months. A subset of the data were analyzed manually and subsequently used to train machine-learning models to facilitate the evaluation of the remaining 50k anomalous events identified in the dataset. We describe the analysis approach used here and discuss the results in terms of radioisotope classes and frequency patterns over day-of-week and time-of-day spans. Data from this work has been archived and is available for future and ongoing research applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ASCENT: a balloon-borne hard x-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. Here, the isotope Ti44 is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard x-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called A SuperConducting ENergetic x-ray Telescope (ASCENT). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55-eV full-width half maximum energy resolution at 97 keV. This 8- to 16-fold improvement in energy resolution over NuSTAR will allow for high-resolution imaging and spectroscopy of the Ti44 emission. This will allow for a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as, What is the source of the neutron star kicks? What is the dominant production pathway for Ti44? Is the engine of Cas A unique?

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma-ray spectrum variations for surface measurements of uranium hexafluoride cylinders

Here, this work aims to characterize features that contribute to the spectral variations that appear in gamma-23 ray spectra of filled uranium hexafluoride (UF 6 ) cylinders. While the enrichment of the UF 6 in a 24 cylinder can greatly affect gamma-ray spectra at peaks such as the 185.7 keV peak and be used to 25 verify enrichment, many other characteristics of a filled UF 6 cylinder can affect the spectra. These 26 characteristics vary on a per-cylinder basis and can include: the time between when a cylinder was 27 filled and when it was measured; the previous fill history of a cylinder; how the cylinder was most 28 recently filled; the UF 6 geometric distribution within the cylinder; and the measurement location 29 along the cylinder. This work explores spectral variations seen in measurement data and uses 30 validated simulation models to find trends in these uncertainties. These trends are analyzed to observe 31 how each parameter can contribute to the overall uncertainty of UF 6 spectral measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact light shield for the Psyche gamma-ray spectrometer

A compact, low-mass light shield has been designed for the Psyche space mission high-purity germanium gamma-ray spectrometer. The spectrometer will be vented to space, which can allow solar photons to enter the cryostat and cause charge-induced noise. The light shield was designed to block more than 99.9% of solar photons while maintaining high molecular conductance to space vacuum. COMSOL simulations and experiments were performed to characterize light shield photon attenuation and molecular conductance. Finally, the light shield was integrated onto the gamma-ray spectrometer and photon suppression and vacuum performance were demonstrated.

(16) Psyche↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GeMini: A High-Resolution, Low-Resource, Gamma-Ray Spectrometer for Planetary Science Applications

GeMini is a high-resolution gamma-ray spectrometer designed for planetary-science exploration. GeMini serves as the basis for instruments being flown on three upcoming deep-space missions: NASA’s mission to the M-class asteroid (16) Psyche, the Japan Aerospace Exploration Agency sample-return mission to the moons of Mars, and NASA’s Dragonfly mission that will land on Saturn’s largest moon, Titan. These science missions require high-resolution spectroscopy in a low-power, low-mass, rugged design that can survive in a variety of environments. GeMini addresses these needs by providing a cryogenically cooled crystal of high-purity germanium that can operate with as little as 10 to 20 watts, depending on the implementation and mission, and has a mass of less than 2 kg. GeMini helps determine the elemental composition of planetary bodies by measuring gamma rays emitted from the surface. This paper describes the mechanical, thermal, and electrical design of GeMini as well as its performance. Further, it describes testing that was performed to validate the design with respect to launch loads and radiation damage. Although the basic design of GeMini is common to all three missions, each planetary body has unique environmental conditions and mission specifications. This paper concludes by describing these upcoming missions and how GeMini is customized for each.

79 ASTRONOMY AND ASTROPHYSICS↗

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗

Crystal Growth and Characterization of Europium-Doped Rubidium Calcium Bromide Scintillators

National security strategies like gamma spectroscopy and high-energy X-ray radiography are limited, in part, by the scintillator used, prompting research into novel materials with improved properties. In this paper, Eu 2+ activated rubidium calcium bromide scintillators were grown via the vertical Bridgman method with a range of dopant concentrations. Light yield, energy resolution, and the afterglow of Rb 4 CaBr 6 :Eu and RbCaBr 3 :Eu improved with increasing Eu 2+ concentration, and scintillation decay time increased. The highest light yields of Rb 4 CaBr 6 :Eu and RbCaBr 3 :Eu were 71000 and 45000 ph/MeV, respectively.

36 MATERIALS SCIENCE↗

Digital pulse analysis for fast neutron recoil spectroscopy with a 4 He scintillation detector

Helium-4-based fast neutron scintillation detectors are an attractive alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, as the response of the detectors to gamma rays is intrinsically limited to low energy deposition. Consequently, the neutron recoil distribution can be measured with these detectors without the need for pulse shape analysis. In this work, the response of an Arktis S670 4 He scintillation detector to D-D, D-T, and 252 Cf neutrons was measured. The detector has a unique construction and readout mechanism, with multiple output channels observing the same scintillation event, and an analysis method was developed to aggregate the outputs from all channels into a single list. The D-D and D-T neutron responses were used to perform a two-point energy calibration, which yielded a near-zero intercept, suggesting that the 4 He scintillation medium behaves linearly to a higher energy than previously reported, and that a two-point calibration is sufficient for nuclear recoil energies below 9 MeV. As a result, the detector was measured to have 16.7-ns FWHM time resolution when using the developed custom analysis, a reduction of 4.9 ns when compared to the conventional pulse analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗