Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Fluidic hydrogen detector production prototype development

A hydrogen gas sensor that can replace catalytic combustion sensors used to detect leaks in the liquid hydrogen transfer systems at Kennedy Space Center was developed. A fluidic sensor concept, based on the principle that the frequency of a fluidic oscillator is proportional to the square root of the molecular weight of its operating fluid, was utilized. To minimize sensitivity to pressure and temperature fluctuations, and to make the sensor specific for hydrogen, two oscillators are used. One oscillator operates on sample gas containing hydrogen, while the other operates on sample gas with the hydrogen converted to steam. The conversion is accomplished with a small catalytic converter. The frequency difference is taken, and the hydrogen concentration computed with a simple digital processing circuit. The output from the sensor is an analog signal proportional to hydrogen content. The sensor is shown to be accurate and insensitive to severe environmental disturbances. It is also specific for hydrogen, even with large helium concentrations in the sample gas.

Roe, G. W.↗

Detecting gas leaks in propellant lines

Leak detector consisting of inflatable bladder and flow-measurement equipment, localizes leaks and allows determination of leak rates past individual components. Fail-safe system prevents overpressurized bladder.

Escue, W. T.↗

Effect of gaseous additives on the response of the helium ionization detector

Changes in the response of the helium ionization detector which occur when varying amounts of gases are added to the helium carrier gas at different applied voltages have been investigated. The addition of hydrogen, argon, oxygen, or nitrogen to the helium carrier gas causes an increase in the detector response when the voltage applied to the detector is more than 350 V, and a decrease in the detector response when the applied voltage is less than 350 V. It was also found that the detector responds positively and linearly to neon when high concentrations of gaseous additives were added to the helium.

Andrawes, F. F.↗

Near-Infrared Single-Photon-Counting Detectors for Laser Instrument Applications at NASA Goddard Space Flight Center

We discuss single-photon-counting detectors requirements for NASA remote sensing and communications systems. We present experimental measurements on several different near-infrared single-photon-counting detectors including InGaAs/InP and InGaAs/InAlAs avalanche photodiodes (APD), an InGaAsP photocathode hybrid photomultiplier (PMT) and an InGaAs photomultiplier. We present the experimental performance of prototype instruments for laser ranging, communication, and trace-gas detection that use these detectors.

Krainak, Michael A.↗

The Gas Chromatograph Mass Spectrometer for the Huygens Probe

Titan is unique in the solar system, the only moon that has a dense atmosphere. The major constituents of the atmosphere, nitrogen and methane, are continuously broken apart by a combination of solar UV, impinging electrons from Saturn s magnetosphere, and a steady flux of cosmic rays. The resulting molecular fragments recombine and form a variety of new species, many of which were detected for the first time by Voyager1 . The ubiquitous, surface- hiding aerosol blanket manifests the existence of still more complex compounds. In addition to hydrocarbons and nitriles, the atmosphere is known to contain CO, CO2 and externally delivered H2O. The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of the atmosphere of Titan from 170 Km altitude (approximately 1hPa) to the surface (approximately 1500hPa) and determine the isotope ratios of the major constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to obtain compositional information of several surface materials. The GCMS consists of a quadrupole mass spectrometer (QP) with a secondary electron multiplier ion detector, a three-column gas chromatograph (GC) and an elaborate gas sampling system. The gas sampling system will provide atmospheric samples to the QP for nearly continuous analysis during the Probe descent and batch samples at several altitudes for GC analysis. It also contains a chemical scrubber for noble gas analysis and an enrichment cell for trace constituent enhancement. In addition to the sampling of the atmosphere periodic gas samples, derived from the pyrolysis of aerosols, will be transferred from the ACP to the GCMS for direct QP and full GCMS analysis. The QP can analyze molecular masses from 2 to 141Dalton. The nominal detection threshold is at a mixing ratio of 10E-8. Data rate is 885 bits/sec. The mass of the instrument is 17.3 kg and the energy required for operation during the descent is 110 Watt-hours.

Niemann, H. B.↗

The Gas Chromatograph Mass Spectrometer for the Huygens Probe

Titan is unique in the solar system, the only moon that has a dense atmosphere. The major constituents of the atmosphere, nitrogen and methane, are continuously broken apart by a combination of solar UV, impinging electrons from Saturn's magnetosphere, and a steady flow of cosmic rays. The resulting molecular fragments recombine and form a variety of new species, many of which were detected for the first time by Voyager 1. The ubiquitous, surface-hiding aerosol blanket manifests the existence of still more complex compounds. In addition to hydrocarbons and nitriles, the atmosphere is known to contain CO, CO2 and externally delivered H2O. The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of the atmosphere of Titan from 170 km altitude (approximately lhPa) to the surface (approximately 1500hPa) and determine the isotope ratios of the major constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to obtain compositional information of several surface materials. The GCMS consists of a quadrupole mass spectrometer (QP) with a secondary electron multiplier ion detector, a three-column gas chromatograph (GC) and an elaborate gas sampling system. The gas sampling system will provide atmospheric samples to the QP for nearly continuous analysis during the Probe descent and batch samples at several altitudes for GC analysis. It also contains a chemical scrubber for noble gas analysis and an enrichment cell for trace constituent enhancement. In addition to the sampling of the atmosphere periodic gas samples, derived from the pyrolysis of aerosols, will be transferred from the ACP to the GCMS for direct QP and full GCMS analysis. The QP can analyze molecular masses from 2 to 14lDalton. The nominal detection threshold is at a mixing ratio of 10E-8. Data rate is 885 bits/sec. The mass of the instrument is 17.3 kg and the energy required for operation during the descent is 110 Watt-hours.

Niemann, H. B.↗

Prospects for high pressure imaging gas scintillation drift chambers

The current developmental status and future potential of a promising hard X-ray and gamma ray detector are presented: the high pressure xenon gas scintillation imaging drift chamber. A scheme for reading out the scintillation light waveshifting fibers, which allows operation at pressures at least as high as 20 atmospheres, is used. This technique combines excellent spatial resolution (approximately 200 rms allowing 1.5 arcminute mapping resolution), very good energy resolution (within a factor of three of Ge detectors), good time resolution (approximately 100 ns), and extremely high sensitivity because of excellent background rejection capabilities; it also offers possibilities for extrapolation to large area detectors. Results from tests with a prototype chamber are presented. The design of a scientific instrument for a balloon flight planned in 1995 is described. This instrument, the Scintillation Imaging Gas filled Hard X-ray Telescope (SIGHT), is optimized for detecting 30 to 300 keV X-rays. It has an active area of 1140 sq cm, with a stopping power of between 2.0 and 2.7 g/sq cm of xenon at 20 atmospheres. Possible future evolutionary tracks of the technology leading to innovative satellite applications are discussed.

Edberg, T. K.↗

Performance of a multistep fluorescence-gated proportional counter for hard X-ray astronomy

Results from the first flight of our proportional counter in an imaging telescope led us to rebuild the detector. We have used a Penning gas mixture (xenon + 1 percent isobutylene) and introduced a preamplification region to improve the energy resolution. We have rebuilt the pressure vessel making novel use of molybdenum as the housing material in order to reduce the residual instrument background, particularly in the fluorescence-gated mode for which the detector design has been optimized. We have also increased the sensitive gas depth from 9 to 14 cm to further increase the sensitivity to both fluorescent pairs and conventional singles. Our calibrations have shown that the overall energy resolution of the detector has been enhanced by a factor of 2, and we predict that the sensitivity at float will increase by a factor of 3 in the 50-70 keV energy band.

Dietz, K. L.↗

A rocket borne instrument for the study of soft X-ray emission from cosmic X-ray sources

Details about a rocket-borne instrument designed for studying the various characteristics of soft X-ray emission from cosmic X-ray sources in the energy range of 0.2 to 3 keV are presented. The X-ray detector consists of a bank of four multilayer, wall-less proportional counters, each with an area of 400 sq cm. The detectors are covered by windows of 1.4-micron polypropylene and are maintained at a constant pressure in flight using a gas control system. Two of the detectors are equipped with 0.4- by 10-deg collimators for mapping the spatial distribution of soft X-rays from extended X-ray sources. A pair of balanced filters consisting of oxygen and CF4 are used for detecting oxygen emission lines.

Agrawal, P. C.↗

The high energy cosmic ray detector for Spacelab II

A large cosmic ray detector to be flown on Spacelab II is presently under construction at the University of Chicago. The instrument, with a geometric factor of 5 sq m-ster, is designed to measure the elemental composition and the energy spectra of individual cosmic ray nuclei (Li to Fe) from 50 GeV/nucleon to several TeV/nucleon. Plastic scintillators are used for charge determination, and gas Cerenkov and transition radiation detectors for energy measurements. The instrument and its functions are described, and several test results that are important for an optimum design are discussed.

Lamport, J. E.↗

System and Method for Determining Fluence of a Substance

A system and method for measuring a fluence of gas are disclosed. The system has a first light detector capable of outputting an electrical signal based on an amount of light received. A barrier is positionable adjacent the first light detector and is susceptible to a change in dimension from the fluence of the gas. The barrier permits a portion of light from being received by the first light detector. The change in the dimension of the barrier changes the electrical signal output from the first light detector. A second light detector is positionable to receive light representative of the first light detector without the barrier. The system and method have broad application to detect fluence of gas that may cause erosion chemical reaction causing erosive deterioration. One application is in low orbit Earth for detecting the fluence of atomic oxygen.

Banks, Bruce A.↗

Interchange for Joint Research Entitled: Miniature Laser Spectrometer for Stable Isotope Measurements

As a first step in successfully measuring carbon isotopes optically we have previously demonstrated the measurement of C-13/C-12 to a precision of 0.1% using a tunable diode laser and CO2 spectral lines in the 2300/cm spectral region. This precision of 0.1% (1 per mil) for carbon isotopes is a value sufficiently precise to provide important isotopic data of interest to astrobiologists. The precision presently attainable in gases is sufficient to permit our instrument to be used in the measurement of isotopic ratios of interest to astrobiologists as well as geologists and planetary scientists. A small stable isotope laser spectrometer with a 10 cm path gas cell was designed and constructed. The cell was integrated with a liquid nitrogen cooled tunable diode laser and indium antimonide detector for evaluation. Using the small gas cell, preliminary measurements of 13C/12C in CO2 were made employing single-beam sequential acquisitions of the required spectral data. The results indicate an accuracy of 0.1% which is sufficiently high to make meaningful measurements of martian samples. In addition, improvements in the spectrometer gas handling system have been made to markedly reduce C-13/C-12 isotopic fractionation during sample gas cell loading which we expect will lead to further improvements in precision and accuracy. An important part of making isotopic ratio measurements in solid samples using diode lasers is the conversion of the elements of interest to molecules that have absorption spectra in the mid-ir spectral range accessible by tunable diode lasers. In this project we have investigated the necessary sample preparation procedures to extract carbon, an element of astrobiological importance, from model soil compounds and to convert it to CO2, a molecule with appropriate optical absorption characteristics for reliable laser spectrometer isotopic ratio measurements of 13C/12C. We have considered calcium carbonate as a model for a component of the martian regolith, and we have formulated a simple heating protocol for extracting carbon in the form of CO2.

Becker, J. F.↗

Cosmic ray experimental observations

The current experimental situation in cosmic ray studies is discussed, with special emphasis on the development of new detector systems. Topics covered are the techniques for particle identification, energy measurements, gas Cerenkov counters, magnet spectrometers, ionization spectrometers, track detectors, nuclear emulsions, multiparameter analysis using arrays of detectors, the Goddard ionization spectrometer, charge spectra, relative abundances, isotope composition, antinuclei in cosmic rays, electrons, the measurement of cosmic ray arrival directions, and the prehistory of cosmic rays.

Balasubrahmanyan, V. K.↗

Detectors for high energy cosmic rays on Spacelab

Two instruments designed to determine the spectra of the individual cosmic-ray components at very high energies are described. One of these (CRNE) uses a combination of gas Cerenkov counters and transition radiation detectors for the cosmic-ray nuclei lithium to nickel; the other (TRIC) is optimized for the light cosmic rays (electrons, protons, helium) and uses a transition-radiation/ionization-calorimeter combination. The CRNE instrument, constructed at the University of Chicago, was delivered to NASA for a first Shuttle flight on Spacelab-2 in summer 1985. Some of the technical and programmatic requirements encountered during the hardware construction and integration are discussed, and the expected scientific return and the prospects of using such instrumentation on the Space Station are considered.

Lheureux, J.↗

Zero-Gravity Vortex Vent and PVT Gaging System

Space Station and satellite reservicing will require the ability to vent gas on orbit from liquid supply or storage tanks and to gage liquid quantity under microgravity conditions. In zero gravity, (zero-g) the vortex vent is capable of venting gas from a tank of liquid containing gas randomly distributed as bubbles. The concept uses a spinning impeller to create centrifugal force inside a vortex tube within a tank. This creates a gas pocket and forces the liquid through a venturi and back into the tank. Gas is then vented from the gas pocket through a liquid detector and then out through an exhaust port. If the liquid detector senses liquid in the vent line, the fluid is directed to the low-pressure port on the venturi and is returned to the tank. The advantages of this system is that it has no rotating seals and is compatible with most corrosive and cryogenic fluids. A prototype was designed and built at the NASA Johnson Space Center and flown on the KC-135 zero-g aircraft. During these test flights, where microgravity conditions are obtained for up to 30 sec, the prototype demonstrated that less than 0.10 percent of the volume of fluid vented was liquid when the tank was half full of liquid. The pressure volume temperature (PVT) gaging system is used in conjunction with the vortex vent to calculate the amount of liquid remaining in a tank under microgravity conditions. The PVT gaging system is used in conjunction with the vortex vent to gage liquid quantity in zero or low gravity. The system consists of a gas compressor, accumulator, and temperature and pressure instrumentation. To measure the liquid in a tank a small amount of gas is vented from the tank to the compressor and compressed into the accumulator. Pressure and temperature in the tank and accumulator are measured before and after the gas transfer occurs. Knowing the total volume of the tank, the volume of the accumulator, the volume of the intermediate lines, and initial and final pressures and temperatures, the mass of the gas leaving the tank is equated to the mass of the gas entering the accumulator. The volume of liquid remaining in the tank is calculated using the ideal gas law.

Downey, M. G.↗

First results from Spacelab 2

Preliminary results of physical experiments carried out during the Spacelab 2 Shuttle mission are summarized. Attention is given to experiments in the fields of plasma dynamics; solar physics; high-energy astrophysics; and astronomy. Plasma experiments included an ejectable plasma diagnosics package and measurements of the passive charging of the Shuttle vehicle in the surrounding space plasma. The solar physics instrument package consisted of a solar spectral irradiance monitor; a solar optical universal polarimeter (SOUP); and a solar helium abundance high-resolution telescope and spectrograph (HRTS). Astronomical observations were performed using a scanning infrared telescope (IRT) which consisted of a highly baffled herschelian telescope and 10 detectors covering wavelengths from 2 to 120 microns. Cosmic-ray nuclei were detected and analyzed using gas Cerenkov counters and a transition radiation detector. Addition experiments included a thin film fluid dynamics payload and analysis of blood samples taken from the mission specialists. Complete data records from the experiments have now been distributed for an analysis period which will take at least a year. A table listing the Spacelab 2 experiments and their principal investigators is provided.

Urban, E. W.↗

OSO-8 soft X-ray wheel experiment: Data analysis

The soft X-ray experiment hardware and its operation are described. The device included six X-ray proportional counters, two of which, numbers 1 and 4, were pressurized with on-board methane gas supplies. Number 4 developed an excessive leak rate early in the mission and was turned off on 1975 day number 282 except for brief (typically 2-hour) periods up to day 585 after which it as left off. Counter 1 worked satisfactorily until 1975 day number 1095 (January 1, 1978) at which time the on-board methane supply was depleted. The other four counters were sealed and all except number 3 worked satisfactorily throughout the mission which terminated with permanent satellie shut-down on day 1369. This was the first large area thin-window, gas-flow X-ray detector to be flown in orbit. The background problems were severe and consumed a very large portion of the data analysis effort. These background problems were associated with the Earth's trapped electron belts.

Kraushaar, W. L.↗