Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Review of Sensing Technologies for New, Low Global Warming Potential (GWP), Flammable Refrigerants

Commercial refrigeration systems currently utilize refrigerants with global warming potential (GWP) values ranging from 1250 to 4000. The advent of low GWP alternatives (GWP <150) is expected to significantly curtail direct emissions from this segment and greatly influence the ongoing electrification and decarbonization efforts. Most of the low GWP alternatives exhibit flammability risk and hence require robust sensing solutions for a reliable and safe operation of the equipment. This review article aims to provide an overview of different sensing mechanisms suitable for potential applications in systems employing flammable refrigerants, particularly those designated as A2L class. A summary of different A2L refrigerants and their properties is provided followed by a broad review of different classes of sensors, their working principle, transduction method, features, advantages, and limitations. Additionally, key performance characteristics of accuracy, selectivity, sensitivity, dynamic characteristic, and durability among other properties are discussed. Finally, areas of improvement and corresponding approaches are suggested for potential sensors in the successful adoption of A2L class refrigerants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Atmospheric H 2 observations from the NOAA Cooperative Global Air Sampling Network

Abstract. The NOAA Global Monitoring Laboratory (GML) measures atmospheric hydrogen (H2) in grab samples collected weekly as flask pairs at over 50 sites in the Cooperative Global Air Sampling Network. Measurements representative of background air sampling show higher H2 in recent years at all latitudes. The marine boundary layer (MBL) global mean H2 was 552.8 ppb in 2021, 20.2 ± 0.2 ppb higher compared to 2010. A 10 ppb or more increase over the 2010–2021 average annual cycle was detected in 2016 for MBL zonal means in the tropics and in the Southern Hemisphere. Carbon monoxide measurements in the same-air samples suggest large biomass burning events in different regions likely contributed to the observed interannual variability at different latitudes. The NOAA H2 measurements from 2009 to 2021 are now based on the World Meteorological Organization Global Atmospheric Watch (WMO GAW) H2 mole fraction calibration scale, developed and maintained by the Max Planck Institute for Biogeochemistry (MPI-BGC), Jena, Germany. GML maintains eight H2 primary calibration standards to propagate the WMO scale. These are gravimetric hydrogen-in-air mixtures in electropolished stainless steel cylinders (Essex Industries, St. Louis, MO), which are stable for H2. These mixtures were calibrated at the MPI-BGC, the WMO Central Calibration Laboratory (CCL) for H2, in late 2020 and span the range 250–700 ppb. We have used the CCL assignments to propagate the WMO H2 calibration scale to NOAA air measurements performed using gas chromatography and helium pulse discharge detector instruments since 2009. To propagate the scale, NOAA uses a hierarchy of secondary and tertiary standards, which consist of high-pressure whole-air mixtures in aluminum cylinders, calibrated against the primary and secondary standards, respectively. Hydrogen at the parts per billion level has a tendency to increase in aluminum cylinders over time. We fit the calibration histories of these standards with zero-, first-, or second-order polynomial functions of time and use the time-dependent mole fraction assignments on the WMO scale to reprocess all tank air and flask air H2 measurement records. The robustness of the scale propagation over multiple years is evaluated with the regular analysis of target air cylinders and with long-term same-air measurement comparison efforts with WMO GAW partner laboratories. Long-term calibrated, globally distributed, and freely accessible measurements of H2 and other gases and isotopes continue to be essential to track and interpret regional and global changes in the atmosphere composition. The adoption of the WMO H2 calibration scale and subsequent reprocessing of NOAA atmospheric data constitute a significant improvement in the NOAA H2 measurement records.

Pétron, Gabrielle↗

Classification of Dissolution Events Using Fusion of Effluents Measurements and Classifiers

Classifiers for dissolution events at a radiochemical processing facility are studied using gamma spectra measurements of effluents collected by a high purity germanium detector located at its off-gas stack. Data sets collected at the Oak Ridge National Laboratory’s Radiochemical Engineering Development Center under a Pu dissolution campaign spanning a three months period are utilized. Features corresponding to the activity levels of 15 radionuclides, including isotopes of iodine, krypton, and xenon, that are indicated by the target decay chains, are computed from the spectra at 1 hour intervals. A conceptualization diagram is developed to reflect the steps from the source to measurement to feature computation that depend on fission products indicated by decay chains, chemical processing, and effluents transport to the off-gas stack. A diverse set of eight classifiers based on different design principles are trained using the ground truth data for this campaign, and the outputs of top three classifiers, namely, classification trees, Ensemble of Trees (EOT), and k-nearest neighbor, are combined using EOT classifier-fuser. Our results show that for 5-fold cross validation, features associated with isotopes of xenon provide the lowest classification error among the different elements across the classifiers; the classification error is furthered improved when all 15 isotope features are used by each classifier, and it is again improved by the fusion of three classifiers. Further reduction in classification error is achieved by using a measurement window of 1-2 days which is identified based on half-life time estimates of the isotopes; it is long enough for the stabilization of feature estimates while being short enough not to be affected by the follow on dissolution events. As a net result of feature and classifier fusion, combined with the incorporation of decay chain and isotope half-life information, this approach achieves 98% detection rate while maintaining a false alarm rate under 2% for this data set.

Rao, Nageswara↗

System and method for remote detection and location of gas leaks

A system for monitoring for a gas leak from a gas containing structure is disclosed. The system includes a lens that directs an image of a scene of interest through an optical filter onto a detector. The filter is associated with the lens and the filter has one or more passbands that passes wavelengths which match one or more emission or reflectively wavelengths of the gas being monitored. A detector receives the image after the image passes through the lens and the filter. The detector generates image data representing the scene including the gas containing structure. A processor is configured to process the image data by executing machine executable code stored on a memory. The machine executable code processes the image data to identify turbulence flows in the image data such that turbulence flow indicates a gas leak, and generate and send an alert in response to the identification of a turbulence flow.

O'Neill, Mary D.↗

The Instrument of the Imaging X-Ray Polarimetry Explorer

While X-ray spectroscopy, timing, and imaging have improved much since 1962 when the first astronomical nonsolar source was discovered, especially wi the launch of the Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer, and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, which in turn is a result of the fate of approved missions and because celestial X-ray sources appear less polarized than expected. Only one positive measurement has been available until now: the Orbiting Solar Observatory measured the polarization of the Crab Nebula in the 1970s. The advent of microelectronics techniques has allowed for designing a detector based on the photoelectric effect of gas in an energy range where the optics are efficient at focusing in X-rays. Here we describe the instrument, which is the major contribution of the Italian collaboration to the Small Explorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will launch in late 2021. The instrument is composed of three detector units based on this technique and a detector service unit. Three mirror modules provided by Marshall Space Flight Center focus X-rays onto the detectors. We show the technological choices, their scientific motivation, and results from the calibration of the instrument. IXPE will perform imaging, timing, and energy-resolved polarimetry in the 2–8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.

79 ASTRONOMY AND ASTROPHYSICS↗

The DUNE Near Detector

DUNE is a next-generation experiment aiming to provide precision measurements of neutrino oscillation parameters. It will detect neutrinos produced in the Long-Baseline Neutrino Facility beamline at Fermilab, using a Near Detector situated near the beam target where the neutrinos originate and a Far Detector located 1300 km away in South Dakota. A comparison of the spectra of neutrinos measured at the Far and the Near Detector will allow for the extraction of oscillation probabilities from which the oscillation parameters can be inferred. The specific role of the Near Detector is to serve as the experiment’s control: it will establish the no oscillation null hypothesis, measure and monitor the beam, constrain systematic uncertainties, and provide essential measurements of the neutrino interactions to improve models. The Near Detector complex will include three primary detector components: a liquid argon time projection chamber, a high-pressure gas time projection chamber and an on-axis beam monitor. The three detectors will serve important individual and overlapping functions, with two of them being also able to move transverse to the beam’s axis via the DUNE-PRISM program. The overall mission of the Near Detector, as well as the three sub-detectors’ unique capabilities and physics programs will be discussed in these proceedings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digitization modeling of a CGEM detector based on Garfield++ simulation

Abstract Background The Cylindrical Gas Electron Multiplier Inner Tracker (CGEM-IT) is one of the candidates for the replacement of the current BESIII inner drift chamber, which has developed serious aging effects due to beam-related backgrounds. Purpose To build a full digitization model, it is necessary to understand the electron drift behavior and signal induction. Methods A simulation study based on Garfield++ and ANSYS software has been performed. Results Parameters describing the Lorentz angle, diffusion effect, drift time, multiplication, and induction are obtained from the Garfield++ simulation. Based on these results, a preliminary digitization model is implemented in the BESIII offline software system.

Zhao, Jing-Yi (ORCID:0000000220287286)↗

One-shot gas detection with transformer paired neural networks in Mako collected longwave infrared hyperspectral imagery

To date, careful data treatment workflows and statistical detectors are used to perform hyperspectral image (HSI) detection of any gas contained in a spectral library, which is often expanded with physics models to incorporate different spectral characteristics. In general, surrounding evidence or known gas-release parameters are used to provide confidence in or confirm detection capability, respectively. This makes quantifying detection performance difficult as it is nearly impossible to develop an absolute ground truth for gas target pixel presence in collected HSI. Consequently, developing and comparing new detection methods, especially machine learning (ML)-based methods, is susceptible to subjectivity in derived detection map quality. Here, in this work, we demonstrate the first use of transformer-based paired neural networks (PNNs) for one-shot gas target detection for multiple gases while providing quantitative classification and detection metrics for their use on labeled data. Terabytes of training data are generated from a database of long-wave infrared HSI obtained from historical Mako sensor campaigns over Los Angeles. By incorporating labels, singular signature representations, and a model development pipeline, we can tune and select PNNs to detect multiple gas targets that are not seen in training on a quantitative basis. We additionally assess our test set detections using interpretability techniques widely employed with ML-based predictors, but less common with detection methods relying on learned latent spaces.

Hyperspectral imaging↗

Tunable diode laser absorption spectroscopy with corrected laser ramping nonlinearities

A tunable diode laser absorption spectroscopy device includes a tunable diode laser. A laser driver is configured to drive the diode laser and ramp it within a particular frequency range. An analyte gas container, a reference gas container, and a fringe generating device are configured to receive the laser therethrough. An optical detector is configured to detect the laser after it has passed through the analyte gas container and/or the reference gas container, and the in-line fringe generating device. An acquisition card is configured to sample an output of the optical detector. A spectral analyzer is configured to receive output data from the acquisition card, determine a spectrum of the output data, decouple the fringe spectrum from the measured spectrum, calibrate the spectrum based on an expected ideal spectrum of both the fringe and reference gas, and determine a composition of the analyte based on the calibrated spectrum.

42 ENGINEERING↗

Investigation of the 244 Pu ⁢( 48 Ca,𝑥⁢𝑛) 292−𝑥 Fl reaction with the LBNL SHREC detector: Investigation of decay chains of isotopes of flerovium (𝑍=114)

The 244 Pu ⁢( 48 Ca,𝑥⁢𝑛)⁢ 292−𝑥 Fl reaction was investigated at Lawrence Berkeley National Laboratory’s 88 Inch Cyclotron using the Berkeley Gas-filled Separator (BGS), the newly installed Superheavy Recoil detector, along with an upgraded digital electronics and data acquisition system. Seven decay chains were observed starting with an evaporation residue, followed by a single 𝛼 decay and a spontaneous fission. The decay characteristics of these seven decay chains led to an assignment to 288 Fl , the product of the 4⁢𝑛 reaction channel. Two additional chains were (tentatively) assigned to the decay of the 3⁢𝑛 exit channel, 289 Fl . Cross sections for the 4⁢𝑛 and 3⁢𝑛 exit channels were 𝜎 prod =6.7⁢($^{36}_{25}$) pb and 𝜎 prod =1.6⁢($^{22}_{11}$) pb, respectively. Another decay chain, tentatively assigned to the 5⁢𝑛 exit channel through the 48 Ca + 244 Pu reaction or the 3⁢𝑛 exit channel of the 48 Ca + 242 Pu reaction, was also detected. Detailed information regarding the observed decay chains and their nuclear structure aspects is discussed, along with the performance of the BGS and the new detection system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commissioning of an MPGD-based Drift Chamber for Heavy-ion Tracking in FRIB's Sweeper magnet system

A newly developed drift chamber equipped with an innovative hybrid Micro-Pattern Gaseous Detector based readout was commissioned at FRIB. The detector consists of a Multi-layer Thick Gas Electron Multiplier (M-THGEM) mounted over a high-granularity, position-sensitive readout board. Denoted as the Micro-Pattern Drift Chamber (MPDC), the new device is used to provide tracking capability as part of the detectors of the Sweeper magnet system for neutron-invariant-mass spectrometry at the Facility for Rare Isotope Beams (FRIB). The localization of impinging ions in a 30 × 30 cm 2 drift area is derived by processing the charge-avalanche distribution induced on the segmented readout board. The signals induced on the readout pads are processed by a compact, multi-channel Data Acquisition System (DAQ) based on the Scalable Readout System (SRS). To facilitate synchronization with other detector systems of the Sweeper magnet system, the SRS has been configured to accept an external trigger.

Gaseous detectors↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPY: a conceptual design study of a magnet system for a high-pressure gaseous TPC neutrino detector

Here, we present a novel conceptual design for a magnet system that provides the magnetic field necessary for the analysis of tracks in a high-pressure gaseous argon TPC while simultaneously serving as a pressure vessel to contain the TPC gas volume. The magnet was developed within a Near Detector proposal for the Deep Underground Neutrino Experiment (DUNE). The high-pressure gaseous argon TPC is a component proposed to be one of the elements of an ensemble of near detectors that are needed for DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic Instrumentation at ProtoDUNE

The cryogenic instrumentation of ProtoDUNE successfully operated during the first run of the experiment, providing a comprehensive monitoring of the cryostats, the cryogenics system and the detectors. It includes devices to measure the liquid argon level, the electron lifetime, the temperature of the liquid and gas argon, the pressure inside the cryostat and the contamination of the gas argon, as well as cameras to inspect the most critical detector elements. These systems and their performance are reviewed, and a few aspects of their future upgrade discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The quest for efficient oxygenated fuels: Examining interactions between lubricant components and oxygenates

This work empirically evaluated oxygenated blendstock-lubricant compatibility using a novel but simple method. The reactivity or compatibility was evaluated via gas chromatograph equipped with a flame ionization detector (GC-FID) before and after heating for 2h at 150 °C, which would roughly mimic conditions encountered in the combustion chamber of an Spark Ignition (SI) or Compression-Ignition (CI) engine. Five oxygenate blendstocks spanning several functional groups and chain lengths (prenol, isoprenol, butyl acetate, isohexanol, polyoxymethylene dimethyl ethers) were evaluated in a base fuel with nine variations of lubricant components of controlled concentrations, including fully formulated commercial lubricants. Baseline comparative examples were also generated, to decouple the effect of the oxygenate on the mixture, by heating only the base fuel with the lubricant component. Results demonstrate the relative compatibility between noted lubricants and oxygenates in base fuel upon heating. This was illustrated by minimal to no changes in the GC-FID traces. However, reactions of several of the chosen lubricants, especially Molybdenum di (2-ethylhexyl) phosphorodithioate (Molyvan L) and zinc dialkyldithiophosphate (ZDDP), with prenol and polyoxymethylene dimethyl ethers blendstocks showed substantial side reactions compared to corresponding baseline examples. Control experiments without oxygenates but comprising the same lubricant components showed no change in the mixture with heating. We concluded the incompatibility is due to the oxygenate and not the components of the base fuel. This preliminary work is valuable in establishing trends as well as provide useful information when a new component is introduced in the fuel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation study for particle identification with the dRICH of the ePIC experiment at the EIC

The dual-radiator Imaging Cherenkov detector (dRICH), employing an aerogel and a gas radiator, is a key component of the forward particle identification system for the ePIC experiment at the Electron-Ion Collider (EIC). This study evaluates the dRICH performance using Geant4 simulations in the context of the global ePIC simulation stack, focusing on the optimization of the aerogel radiator and the impact of sensor noise. We compare two aerogel configurations: the initial design (n = 1.019) and the current default (n = 1.026). The latter, characterized by improved optical properties and a higher refractive index, demonstrates enhanced π/K separation at high momenta, effectively extending the operational overlap with the C 2 F 6 gas radiator (n = 1.00076 at 25 °C, as implemented in the simulation software). Additionally, the study investigates the impact of Silicon Photomultiplier (SiPM) dark noise, showing that a 300 kHz noise rate per 3mm x 3mm channel leads to a moderate reduction (approximately 1.5 GeV/c) in the 3σ separation threshold. These results validate the current dRICH design and quantify the purity levels achievable for both radiators under expected experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of Intermediate Species in Fuel-Rich Oxidation of Ethylene, Toluene, and n -Decane

Polycyclic aromatic hydrocarbons (PAHs) are important precursors to the formation of soot and are also pollutant emissions from combustion devices, including internal combustion engines. To understand the formation of PAHs, the low-molecular-weight hydrocarbon chemistry leading to their formation needs to be understood. Toward this goal, fuel-rich oxidation of three different hydrocarbons, i.e., ethylene, toluene, and n-decane, has been investigated in an atmospheric pressure flow reactor at varying temperatures (1000–1350 K), equivalence ratios (φ = 3.0–12.0), and residence times of 0.25–1.5 s. The major C 1 to C 7 intermediates, such as methane, acetylene, ethylene, allene, propyne, propylene, vinylacetylene, 1,3-butadiene, cyclopentadiene, benzene, and toluene, were quantified using a gas chromatograph equipped with a flame ionization detector. The experimental tendency of intermediate species formation, e.g., the dependence of temperature, equivalence ratio, and residence time, was similar in ethylene oxidation and n-decane oxidation. The concentrations of intermediate species up to C 4 were higher in ethylene/n-decane oxidation than toluene oxidation, while a nearly equal or larger amount of C5–C7 species was produced in toluene oxidation. The experimental data were compared with modeling results using a detailed chemical kinetic mechanism. The calculated data using the kinetic model were in agreement with the experimental results. Additionally, a comprehensive kinetic analysis on the reaction pathways of each species was conducted to assess the differences in the oxidation chemistry with the change in the structure of hydrocarbons. In particular, in-depth analysis of benzene formation was performed, elucidating that two benzene formation pathways were important in ethylene and n-decane oxidation: (1) H elimination of the 2,4-cyclohexadienyl radical produced from the isomerization of the 2,4-cyclopentadienylmethyl radical, and (2) dehydrogenation of cyclohexadiene produced from reactions of vinyl radical with 1,3-butadiene. In toluene oxidation, it was found that benzene was primarily produced from toluene through the replacement of the methyl group with hydrogen.

30 DIRECT ENERGY CONVERSION↗