Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gloves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design of a Power-Assisted Spacesuit Glove Actuator

This paper presents the details of the design and implementation of an electromechanical power-assisted spacesuit glove actuator. The project was a joint effort by the University of Maryland's Space Systems Laboratory and ILC Dover, Inc., and involved innovative approaches to power augmentation and compact actuator packaging. The first actuator built validated several basic design concepts, and the second demonstrated improved performance and met many of the goals for flight qualification of the technology.

Howard, Russell D.↗

Glove-Box or Desktop Virtual-Reality System

The salient features of the optical layout of a desktop-scale virtual-reality system that is specialized for simulating a glove-box work space are depicted and described.

Smith, J. D.↗

Hazard Analysis for Building 34 Vacuum Glove Box Assembly

One of the characteristics of an effective safety program is the recognition and control of hazards before mishaps or failures occur. Conducting potentially hazardous tests necessitates a thorough hazard analysis in order to prevent injury to personnel, and to prevent damage to facilities and equipment. The primary purpose of this hazard analysis is to define and address the potential hazards and controls associated with the Building 34 Vacuum Glove Box Assembly, and to provide the applicable team of personnel with the documented results. It is imperative that each member of the team be familiar with the hazards and controls associated with his/her particular tasks, assignments and activities while interfacing with facility test systems, equipment and hardware. In fulfillment of the stated purposes, the goal of this hazard analysis is to identify all hazards that have the potential to harm personnel, damage the facility or its test systems or equipment, test articles, Government or personal property, or the environment. This analysis may also assess the significance and risk, when applicable, of lost test objectives when substantial monetary value is involved. The hazards, causes, controls, verifications, and risk assessment codes have been documented on the hazard analysis work sheets in Appendix A of this document. The preparation and development of this report is in accordance with JPR 1700.1, "JSC Safety and Health Handbook" and JSC 17773 Rev D "Instructions for Preparation of Hazard Analysis for JSC Ground Operations".

Meginnis, Ian↗

LFC leading edge glove flight: Aircraft modification design, test article development and systems integration

Reduction of skin friction drag by suction of boundary layer air to maintain laminar flow has been known since Prandtl's published work in 1904. The dramatic increases in fuel costs and the potential for periods of limited fuel availability provided the impetus to explore technologies to reduce transport aircraft fuel consumption. NASA sponsored the Aircraft Energy Efficiency (ACEE) program in 1976 to develop technologies to improve fuel efficiency. This report documents the Lockheed-Georgia Company accomplishments in designing and fabricating a leading-edge flight test article incorporating boundary layer suction slots to be flown by NASA on their modified JetStar aircraft. Lockheed-Georgia Company performed as the integration contractor to design the JetStar aircraft modification to accept both a Lockheed and a McDonnell Douglas flight test article. McDonnell Douglas uses a porous skin concept. The report describes aerodynamic analyses, fabrication techniques, JetStar modifications, instrumentation requirements, and structural analyses and testing for the Lockheed test article. NASA will flight test the two LFC leading-edge test articles in a simulated commercial environment over a 6 to 8 month period in 1984. The objective of the flight test program is to evaluate the effectiveness of LFC leading-edge systems in reducing skin friction drag and consequently improving fuel efficiency.

Etchberger, F. R.↗

Laminar flow control leading edge glove flight test article development

A laminar flow control (LFC) flight test article was designed and fabricated to fit into the right leading edge of a JetStar aircraft. The article was designed to attach to the front spar and fill in approx. 70 inches of the leading edge that are normally occupied by the large slipper fuel tank. The outer contour of the test article was constrained to align with an external fairing aft of the front spar which provided a surface pressure distribution over the test region representative of an LFC airfoil. LFC is achieved by applying suction through a finely perforated surface, which removes a small fraction of the boundary layer. The LFC test article has a retractable high lift shield to protect the laminar surface from contamination by airborne debris during takeoff and low altitude operation. The shield is designed to intercept insects and other particles that could otherwise impact the leading edge. Because the shield will intercept freezing rain and ice, a oozing glycol ice protection system is installed on the shield leading edge. In addition to the shield, a liquid freezing point depressant can be sprayed on the back of the shield.

Pearce, W. E.↗

Human Motion Tracking and Glove-Based User Interfaces for Virtual Environments in ANVIL

The Army/NASA Virtual Innovations Laboratory (ANVIL) at Marshall Space Flight Center (MSFC) provides an environment where engineers and other personnel can investigate novel applications of computer simulation and Virtual Reality (VR) technologies. Among the many hardware and software resources in ANVIL are several high-performance Silicon Graphics computer systems and a number of commercial software packages, such as Division MockUp by Parametric Technology Corporation (PTC) and Jack by Unigraphics Solutions, Inc. These hardware and software platforms are used in conjunction with various VR peripheral I/O (input / output) devices, CAD (computer aided design) models, etc. to support the objectives of the MSFC Engineering Systems Department/Systems Engineering Support Group (ED42) by studying engineering designs, chiefly from the standpoint of human factors and ergonomics. One of the more time-consuming tasks facing ANVIL personnel involves the testing and evaluation of peripheral I/O devices and the integration of new devices with existing hardware and software platforms. Another important challenge is the development of innovative user interfaces to allow efficient, intuitive interaction between simulation users and the virtual environments they are investigating. As part of his Summer Faculty Fellowship, the author was tasked with verifying the operation of some recently acquired peripheral interface devices and developing new, easy-to-use interfaces that could be used with existing VR hardware and software to better support ANVIL projects.

Joseph D. Dumas, II↗

ASTROCULTURE(tm) Commercial Plant Growth Unit and Glove Box Insert

Two commercial plant investigations will be conducted during the STS-107 mission: living flower essential oil production and gene transfer. The research will be done using the ASTROCULTURE (trademark) hardware, which builds on similar experiments flown in the past on the space shuttle. This research will investigate how microgravity might affect the formation of the volatile chemical compounds - the essential oils - produced by two different types of living flowers. The flowers will be cultured in the ASTROCULTURE (trademark) plant chamber, which provides an enclosed and controlled environment. As the flowers bloom in space, they will produce essential oils, and these volatile compounds will be collected using International Flavors and Fragrance's proprietary Solid Phase Micro Extraction (SPME) technology. The gene transfer experiment examines a newly developed transformation system to see if it operates efficiently in the microgravity environment. This research is important for the development of genetically engineered crops, also known as transgenic crops.

Wei-Jia Zhou↗

Efficacy of Wrist/Palm Warming as an EVA Countermeasure to Maintain Finger Comfort in Cold Conditions During EVA

This study explored the effectiveness of local wrist/palm warming as a potential countermeasure for providing finger comfort during extended duration EVA. Methods: Six subjects (5 males and 1 female) were evaluated in a sagitally divided liquid cooling/warming garment (LCWG) with modified liquid cooling/warming (LCW) gloves in three different experimental conditions. Condition 1: Stage 1- no LCWG; chamber adaptation with LCW glove inlet water temperature 33 C; Stage 2-LCW glove inlet water temperature cooled to 8 C; Stage 3-LCW glove inlet water temperature warmed to 45 C; Condition 2: Stage1-LCWG and LCW glove inlet water temperature 33 C; Stage 2-LCWG inlet temperature cooled to 31 C, LCW gloves, 8 C; Stage 3-LCWG inlet water temperature remains at 31 C, LCW glove inlet water temperature warmed to 45 C; Condition 3: Stage l -LCWG and LCW gloves 33 C; Stage 2-LCWG inlet water temperature cooled to 28 C, LCW gloves, 8 C; Stage 3-LCWG remains at 28 C, LCW glove water temperature warmed to 45 C. Results: Wrist/palm area warming significantly increased finger temperature (Tfing) and blood perfusion in Stage 3 compared to Stage 2. The LCW gloves were most effective in increasing Stage 3 Tfing in Condition 1; and in increasing blood perfusion in Conditions 1 and 2 compared to Condition 3. Ratings of subjective perception of heat in the hand and overall body heat were higher at Stage 3 than Stage 2, with no significant differences across Conditions. Conclusions: Local wrist/palm warming was effective in increasing blood circulation to the distal extremities, suggesting the potential usefulness of this technique for increasing astronaut thermal comfort during EVA while decreasing power requirements. The LCW gloves were effective in heating the highly cooled fingers when the overall body was in a mild heat deficit.

Koscheyev, Victor S.↗

Analysis of Human-Spacesuit Interaction

Astronauts sustain injuries of various natures such as finger delamination, joint pain, and redness due to their interaction with the space suit. The role of the Anthropometry and Biomechanics Facility is to understand the biomechanics, environmental variables, and ergonomics of the suit. This knowledge is then used to make suggestions for improvement in future iterations of the space suit assembly to prevent injuries while allowing astronauts maneuverability, comfort, and tactility. The projects I was involved in were the Extravehicular Mobility Unit (EMU) space suit stiffness study and the glove feasibility study. The EMU project looked at the forces exerted on the shoulder, arm, and wrist when subjects performed kinematic tasks with and without a pressurized suit. The glove study consisted of testing three conditions - the Series 4000 glove, the Phase VI glove, and the no glove condition. With more than forty channels of sensor data total, it was critical to develop programs that could analyze data with basic descriptive statistics and generate relevant graphs to help understand what happens within the space suit and glove. In my project I created a Graphical User Interface (GUI) in MATLAB that would help me visualize what each sensor was doing within a task. The GUI is capable of displaying overlain plots and can be synchronized with video. This was helpful during the stiffness testing to visualize how the forces on the arm acted while the subject performed tasks such as shoulder adduction/abduction and bicep curls. The main project of focus, however, was the glove comparison study. I wrote MATLAB programs which generated movies of the strain vectors during specific tasks. I also generated graphs that summarized the differences between each glove for the strain, shear and FSR sensors. Preliminary results indicate that the Phase VI glove places less strain and shear on the hand. Future work includes continued data analysis of surveys and sensor data. In the end, the ideal glove is one that provides more tactility for the astronauts but lessens injuries. Often times, a more tactile glove transmits forces better to the hand; thus, achieving a balance of both a tactile and safe glove is the main challenge present.

Thomas, Neha↗

Mechanical counter pressure on the arm counteracts adverse effects of hypobaric exposures

INTRODUCTION: Current space suits have limited movement due to gas pressurization during exposure to the vacuum of space. Alternatively, if pressure is applied by an elastic garment vs. pneumatic garment to produce mechanical counter pressure (MCP), several advantages are possible. In this study, we investigate local microcirculatory and other effects produced with and without a prototype MCP glove and sleeve during exposure to varying levels of vacuum. METHODS: The entire arms of eight male volunteers were studied at normal ambient pressure and during 5 min exposures to -50, -100, and -150 mm Hg with and without the MCP glove and sleeve. Pressure distribution, skin microvascular flow, and temperature were measured. RESULTS: The MCP glove and sleeve generated over 200 mm Hg on the middle finger, dorsum of the hand, and the wrist. However, pressure was significantly lower on the forearm and the upper arm. Without the glove and sleeve, only two of eight subjects tolerated -100 mm Hg. Also, no subject tolerated -150 mm Hg. However, subjects tolerated all vacuum pressures wearing the glove and sleeve. Skin microvascular flow and temperature remained within control values with the glove and sleeve at a chamber pressure of -150 mm Hg. DISCUSSION: The MCP glove and sleeve counteracts adverse effects of vacuum exposures due to lower pressure differentials. Pressure levels over the hand and wrist are similar to those of the current U.S. space suit glove and sleeve, but additional development is required to increase MCP over the forearm and upper arm.

NASA Discipline Cardiopulmonary↗