At least 163 records · Page 9

Assessing the role of secondary electron emission on the characteristics of 6-cavity magnetrons with transparent cathode through particle-in-cell simulations

Effects of secondary electron emission (SEE) on the performance of a 6-cavity relativistic magnetron with transparent cathodes are probed through particle-in-cell simulations. Appropriate relations for the secondary electron yield have been developed and used. For comparisons, separate simulations have been performed with- and without electron cascading. Simulation results seem to indicate SEE to be detrimental to the power output due to deviations in the starting trajectories of secondary electrons, and the reduced fraction with synchronized rotational velocity. A higher reduction in output power is predicted with electron cascading, though mode competition was not seen at the 0.65 T field. A possible solution to mitigating SEE in magnetrons for high power microwave applications would be to alter the surface properties of emitting electrodes through irradiation, which can lead to graphitic film formation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data Report on Post-Irradiation Dimensional Change of AGC-1 Samples

This report documents the measured post irradiation dimensional change in the AGC-1 samples. The AGC-1 capsule is the first in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. AGC-1 irradiation began September 5, 2009 in the Advanced Test Reactor (ATR) and was completed on January 8, 2011. The capsule was cooled for 3 months in the ATR Canal, and then shipped to MFC in April 2011 for disassembly and sample extraction. After extraction the samples were shipped to the INL Research Center (IRC) for initial post-irradiation examination (PIE) and storage in the irradiated graphite vault. The AGC-1 capsule design contained “matched pair” samples to ascertain the irradiation-induced dimensional changes and levels of creep experienced in different graphite types. The irradiation-induced dimensional changes and creep levels are determined by comparing the total dimensional change for stressed and unstressed samples of the same type of graphite exposed to the same dose levels and at similar temperatures. Under irradiation creep (i.e. permanent strain due to irradiation, stress, and temperature) the stressed samples should demonstrate more dimensional change than the unstressed samples. This additional dimensional change in the stressed samples is designated as “irradiation-induced creep” in graphite. The data are further presented using the parameters influencing dimensional change in graphite; levels of induced stress, temperature, graphite type, and dose. However, the AGC-1 post-irradiation examination is a significant endeavor and this data report serves to provide irradiation-induced dimensional change data for AGC capsule design refinement as well as a status on the progress of the PIE activities. The dimensional changes of both the samples and graphite body are very important to the design of the future AGC capsules (AGC-3 through AGC-6) and are provided as soon as the data are available in order to determine whether design changes to the next capsule are required. A complete evaluation of the irradiation-induced dimensional change data will be performed for a final AGC-1 PIE report that will include full analysis of pre- and post-irradiation data, with verified AGC-1 irradiation conditions of temperature and dose.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interesting Graphite Facts

Interesting facts about graphite. Graphite within HTRs and how long they will last, potential issues prediction, model building to predict expected behavior, and frequent and thorough inspection and monitoring strategy.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of radiation damage effects in high-energy neutrino target graphite using low-energy ions

Exposure of graphite targets to high intensity proton beams at neutrino production facilities causes changes in the target material that can result in a shortened operation lifetime. The dominant factors in this process are currently thought to be mechanical in nature resulting primarily from microstructural effects that lead to thermal and structural changes in bulk material properties. As currently planned beam facilities with increased proton energy and intensity begin to come online it will be important to thoroughly understand these processes, and ideally to be able to predict the effects of new beam designs on target properties. Direct analysis of targets exposed to existing high-energy proton beams is complicated by several factors, such as very limited access to proton beam facilities, high associated costs, irradiation times on the order of months, and the resulting radioactivity of irradiated samples that requires special facilities for post-irradiation examination. Much of the existing literature concerning irradiation damage in graphite has been focused on the needs of the nuclear engineering community, however high-energy proton targets operate in a much different environment. In comparison to graphite irradiated in a nuclear reactor, graphite used in proton beam targets receives a higher dose rate, have greater gas production, and experience short irradiation pulses as opposed to continuous irradiation. Low-energy ion irradiation offers a method of inducing similar levels of radiation damage to high-energy protons while avoiding many of the difficulties and limitations associated with high-energy proton beams and the corresponding activated specimen testing. My research described in this thesis focused on investigating how low-energy ion irradiation could be used to induce the same or similar types of microstructural alteration and mechanical property degradation as that seen in high-energy neutrino production target graphites by varying damage le vels and irradiation temperatures prior to post-irradiation characterisation.

43 PARTICLE ACCELERATORS↗

Irradiation test about oxidation-resistant graphite in WWR-K research reactor - 18533

Graphite materials are used for the in-core components of High Temperature Gas-cooled Reactor (HTGR). It is desirable to enhance oxidation resistance of graphite to keep much safety margin. SiC coating is the candidate method for this purpose. JAEA and four Japanese graphite companies, Toyo Tanso, Ibiden, Tokai Carbon and Nippon Techno-Carbon are studying to develop oxidation-resistant graphite for the in-core components. Neutron irradiation test with two capsules was carried out by WWR-K research reactor of Institute of Nuclear Physics of the Republic of Kazakhstan (INP) through the International Science and Technology Center (ISTC) partner project. The total irradiation cycles of WWR-K operation was 10 cycles and the total duration was 200 days. Irradiation temperature about 1473 K would be attained. The maximum fast neutron fluence (E>0.18 MeV) for the gas-swept capsule irradiated at a central irradiation hole was preliminary calculated as 1.2x10{sup 25} m{sup -2}, and for the sealed capsule at a peripheral irradiation hole as 4.2x10{sup 24} m{sup -2}. Dimension and weight of the irradiated specimens were measured, and outer surface of the specimens were observed by optical microscope. For the irradiated oxidation resistant graphite, out-of-pile oxidation test will be carried out at an experimental laboratory. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

As-Run Thermal Analysis for the AGC-4 Experiment Irradiated in the ATR

The Advanced Graphite Capsule (AGC) irradiation experiment will provide irradiation creep rate data for the new graphite proposed for the Next Generation Nuclear Plant (NGNP) program. The fourth experiment in the series (AGC-4) was designed to irradiate various types of graphite specimens at a temperature of 900 ºC and targeted displacements per atom (DPA) of 6. This experiment has been irradiated in the east flux trap of the Advanced Test Reactor (ATR) during the cycles of 157D, 158A, 162A, 162B, 164A, 164B, 166A, and 166B. Temperatures were monitored using twelve thermocouples (TC) located at various elevations in the reactor core, and variable helium-argon gas mixtures were used for gas gap temperature control of the specimens. The purpose of this Engineering Calculation and Analysis Report (ECAR) is to calculate the specimen temperature after the model is calibrated by the measured TC data with the as-run heating rates of the components, DPA of the graphite, and the gas mixture compositions during the experiment. As-run specimen mean temperature and the tolerance will be obtained.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Writable graphene: Breaking sp2 bonds with soft X-rays

We study the stability of various kinds of graphene samples under soft x-ray irradiation. Our results show that in single-layer exfoliated graphene (a closer analog to two-dimensional material), the in-plane carbon-carbon bonds are unstable under x-ray irradiation, resulting in nanocrystalline structures. As the interaction along the third dimension increases by increasing the number of graphene layers or through the interaction with the substrate (epitaxial graphene), the effect of x-ray irradiation decreases and eventually becomes negligible for graphite and epitaxial graphene. Our results demonstrate the importance of the interaction along the third dimension in stabilizing the long range in-plane carbon-carbon bonding, and suggest the possibility of using x-ray to pattern graphene nanostructures in exfoliated graphene.

36 MATERIALS SCIENCE↗

Transforming graphite to nanoscale diamonds by a femtosecond laser pulse

Formation of cubic diamond from graphite following irradiation by a single, intense, ultra-short laser pulse has been observed. Highly oriented pyrolytic graphite (HOPG) samples were irradiated by a 100 fs pulse with a center wavelength of 800 nm. Following laser exposure, the HOPG samples were studied using Raman spectroscopy of the sample surface. In the laser-irradiated areas, nanoscale cubic diamond crystals have been formed. The exposed areas were also studied using grazing incidence x-ray powder diffraction showing a restacking of planes from hexagonal graphite to rhombohedral graphite.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An In Situ transmission electron microscopy study on the synergistic effects of Au-ion irradiation and high temperature on nuclear graphite microstructure

Abstract The combined effects of high-temperature and heavy-ion irradiation on Mrozowski cracks (MC) and nuclear graphite crystallographic dimensions have been studied using in situ heating and in situ ion-irradiation in the transmission electron microscope (TEM). Electron transparent lamella of nuclear graphite, IG-110, was irradiated using a 2.8 MeV Au beam at an ion flux of 3.991 ×10 10 ion cm −2 s −1 for 70 min at 800 °C. Upon high-temperature irradiation, Mrozowski crack closure was studied quantitatively. The analysis showed linear, positive expansion of nuclear graphite which is significantly different from the dimensional changes previously reported for low-dose neutron irradiation of nuclear graphite in which the material undergoes negative to positive expansion via a turnaround radiation dose. The trend of the thermal expansion coefficient (CTE) of pristine IG-110 in this study is consistent with previous reports in the 100 °C–800 °C temperature region in which the dimensional change ranges from negative to positive values.

36 MATERIALS SCIENCE↗

Temperature measurements using multicolor pyrometry in thermal radiation heating environments

Temperature measurements are important for thermal-structural experiments in the thermal radiation heating environments such as used for thermal-structural stress analyses. This paper describes the use of multicolor pyrometry for the measurements of diffuse surfaces in thermal radiation environments that eliminates the effects of background radiation reflections and unknown emissivities based on a least-squares algorithm. The near-infrared multicolor pyrometer had a spectral range of 1100–2400 nm, spectrum resolution of 6 nm, maximum sampling frequency of 2 kHz, working distance of 0.6 m to infinity, temperature range of 700–1700 K. The pyrometer wavelength response, nonlinear intensity response, and spectral response were all calibrated. The temperature of a graphite sample irradiated by quartz lamps was then measured during heating and cooling using the least-squares algorithm based on the calibrated irradiation data. The experiments show that higher temperatures and longer wavelengths are more suitable for the thermal measurements in the quartz lamp radiation heating system. This analysis provides a valuable method for temperature measurements of diffuse surfaces in thermal radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Post-irradiation Experiment on IG-110 and A3-3 Graphites for HTGR - 18494

The first irradiation test of A3-3 graphite matrix and IG-110 graphite were performed in Hanaro during the period of August 2013 through March 2014. The dimensional and weight changes, microstructure, and thermal diffusivity were investigated in different directions of the specimen after the irradiation. Interestingly, the density of the A3-3 matrix was increased by 9.4% due to the weight increase after the irradiation. Moreover, the thermal diffusivity in the radial direction of the A3-3 matrix is almost 3-times higher than that of the axial direction owing to the radially oriented graphite texture shown in the microstructure. Meanwhile, 10-20 {mu}m sized irradiation induced pores are observed in the microstructure of IG-110. The thermal diffusivity measurement of pre- and post-irradiated IG-110 results in a 68% irradiation-dominant decrease of thermal conductivity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Graphite to ultrafine nanocrystalline diamond phase transition model and growth restriction mechanism induced by nanosecond laser processing

To have a clear insight into nanocrystal growth from graphite to diamond upon high energy pulsed laser irradiation of graphite suspension, synthesis of ultrafine nanocrystalline diamonds with laser energy set up from 0.3 J to 12 J, repetition rate of 10 Hz has been studied. The method allows synthesizing ultrafine nanocrystalline particles continuously at the ambient temperature and normal pressure. The particle size is shown independent of laser energy, which is ultrafine and ranges in 2–6 nm. The theoretical grown size of nano-diamonds is found in well agreement with the experiment results. Four kinds of production were found: nano-diamond, spherical carbon nano-particles, flocculent amorphous carbon, and graphene nano-ribbon rolls. A solid-vapor-plasma-liquid coexistence model describing phase transition from graphite to diamond induced by nanosecond laser processing was proposed. Graphene nano-ribbon rolls might be the intermediate phase in the conversion from graphite to diamond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Session 3: Irradiation and Thermal Stesses - NRC Graphite Behavior Model

Graphite anisotropic microstructure Graphite crystal structure and basal planes Response to irradiation and temperature C-axis and a-axis behavior The effect of porosity Nano-and micro-length scale Microscopic to macroscopic response Material property changes Defect length-scale factors Internal stress build-up Irradiation induced dimensional change Temperature effects Stress increases & property changes

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Formation of carbon nanostructures in nuclear graphite under high-temperature in situ electron-irradiation

Defect evolution in nuclear graphite has been studied in real time using high-temperature in situ transmission electron microscopy. In situ electron-irradiation was conducted at 800 °C on a 200 kV transmission electron microscope with a dose rate, given in terms of displacements per atom per second, of approximately 1.46 × 10 –3 dpa/s. Defect domains consisting of ordered arrangements of pentagons, hexagons, and heptagons exist intrinsically in nuclear graphite and in addition are readily produced via electron-irradiation; however, at elevated temperatures these defect domains undergo atomic rearrangements resulting in the formation of carbon nanostructures via curling and closure of the basal planes. The formation of fullerenes and other structures due to thermal annealing or high-temperature electron-irradiation has been observed in disordered regions of the microstructure and interstitially between basal planes. Furthermore, these defect structures result in localized swelling and expansion of crystallites along the c axis; thus, it is proposed as one of the many atomic mechanisms involved in the dimensional change of nuclear graphite subjected to high-temperature irradiation.

36 MATERIALS SCIENCE↗

Electron microscopy data on irradiation effects in glassy carbon, nuclear graphite, pyrolytic carbon, and carbon fibers

Glassy carbon, a monoatomic allotrope of carbon, is a candidate material for components in fission nuclear power systems due to its radiation tolerance. This article presents comprehensive electron microscopy data revealing the effects of neutron and electron irradiation on glassy carbon. For comparison, additional data are provided for pyrolytic graphite and carbon fibers, materials that exhibit similar structural behavior under irradiation. In situ electron irradiation experiments further illustrate the real-time microstructural evolution of glassy carbon during exposure. The dataset is organized into five parts: (1) transmission electron microscopy (TEM) micrographs of as-received and neutron-irradiated glassy carbon; (2) TEM micrographs of neutron-irradiated graphite; (3) TEM micrographs of unirradiated and irradiated carbon–carbon composites; (4) TEM micrographs of pyrolytic carbon specimens in both conditions; (5) scanning transmission electron microscopy (STEM) micrographs of as-received and neutron-irradiated glassy carbon and (6) in situ electron irradiation data of a glassy carbon particle. These datasets provide valuable insights into radiation-induced structural changes in carbon-based materials relevant to nuclear applications.

36 MATERIALS SCIENCE↗

Irradiation-Induced Defect Evolution in Nuclear Graphite

Graphite has historically been used as a moderator material in nuclear reactor designs dating back to the first man-made nuclear reactor to achieve criticality (Chicago Pile 1) in 1942. Additionally, graphite is a candidate material for use in the future envisioned next-generation nuclear reactors (Gen IV); specifically, the molten-salt-cooled (MSR) and very-high-temperature reactor (VHTR) concepts. Gen IV reactor concepts will introduce material challenges as temperature regimes and reactor lifetimes are anticipated to far exceed those of earlier reactors. Irradiation-induced defect evolution is a fundamental response in nuclear graphite subjected to irradiation. These defects directly influence the many property changes of nuclear graphite subjected to displacing radiation; however, a comprehensive explanation for irradiation-induced dimensional change remains elusive. The objectives of this project were focused on the characterization of irradiation-induced defect evolution in nuclear graphite via transmission electron microscopy (TEM). With the use of novel TEM specimen preparation techniques, high-temperature electron-irradiation and characterization of high-temperature neutron-irradiated nuclear graphite, novel fullerene-like defects are shown to be a dominant defect type, especially at higher temperatures. These results contradict the historical models of defect evolution and provide valuable insight into the macroscopically observed property changes in irradiated nuclear graphite.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗