Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT BALANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observation of second harmonic electron cyclotron resonance heating and current-drive transition during non-inductive plasma start-up experiment in QUEST

Here, noninductive plasma current start-up using 2nd harmonic electron cyclotron resonance heating (ECRH) with oblique radio frequency (RF) injection is demonstrated in a Q-shu University experiment with steady-state spherical tokamak. A strong transition was observed in the heating and plasma current ramp-up. The initial bulk electron heating regime exhibits T ebulk ~ 140 eV and no hard x-ray (HXR) emission with a low I p of ~15 kA; it abruptly transitions to a regime that exhibits a low T ebulk of ~10 eV and a strong HXR emission with a high I p of ~50 kA. This behavior is distinctly different from that observed in previous fundamental ECRH experiments. The mechanism of the heating and current drive transition are investigated considering wave power absorption and plasma power balance. The results indicate that the transition is caused by the favorable heating of tail electrons where the RF power absorption at the 2nd harmonic increases nearly linearly with T etail , while the power transfer from the tail electrons to the bulk electrons decreases with 1/T etail 0.5 . This causes a rapid transition to a state with high T etail while reducing T ebulk towards colder ion temperature. The understanding of the transition mechanism helps to consider plasma current start-up using 2nd harmonic ECRH for tokamak reactors such as JT-60 SA and ITER.

QUEST↗

Optimal Design and Techno-Economic Analysis of 3D-Printed, Intensified Packings for Absorbers and Strippers in Solvent-Based CO 2 Capture

A potential technology for the CO 2 absorption process is utilizing intensified structured packing with embedded cooling/heating channels for continuous heat exchange, which can overcome limitations of discrete methods, such as discrete intercooling and centralized reboilers, to aid in reducing energy consumption and decreasing costs. This work investigates the modeling of intensified packing (IP) for the stripper tower, extending on previous work for the absorber, which distributes heat internally within the column, improving the thermodynamics for the solvent regeneration process. The model includes submodels for steam turbine extraction to produce steam at various qualities as well as a surrogate model for calculating steam enthalpy. A cost model for a plant-scale absorption capture process was developed, allowing for the design of the plant to be optimized, subject to minimizing capture cost using two different power plant flue gas sources. In this optimization, the placement of IP in both towers is optimized to balance the trade-off between enhanced heat transfer and reduced mass transfer volume. For natural gas combined cycle flue gas, the standard process configuration had a minimum cost of $\$$65.40/tonne CO 2 , and considering IP, the minimum capture cost is reduced to $\$$62.73/tonne, with utilization in the stripper column, which reduces yearly costs by up to $\$$2.67 MM/yr. Cooling the absorber through IP, or intercoolers, was only found to be beneficial at higher capture rates, with IP in both towers having a cost of capture of $\$$68.08/tonne at 99.9% capture, a reduction of $\$$12.64/tonne when using only intercoolers at the same capture rate. When capturing from pulverized-coal power plants, the minimum cost of capture when using IP in both towers is $\$$44.18/tonne (at 97% capture), while the standard configuration with and without intercoolers was $\$$45.69 and $\$$47.22 per tonne, respectively. This results in a reduction in yearly costs of $\$$16.98 MM/yr from the base-case configuration. At this higher CO 2 concentration, cooling in the absorber from the IP becomes extremely beneficial, reducing energy consumption by up to 6%.

20 FOSSIL-FUELED POWER PLANTS↗

Simulation of Divertor Performance in ST40 Under Dynamic Double-Null Plasmas

A power fraction model was implemented for the simultaneous prediction of 3-D surface temperature evolution at all four divertor targets in near-double-null (DN) tokamak configurations, which is especially important for compact high-field devices that may not have the ability to dissipate large amounts of power on the high-field side. Evaluating the power-sharing between the four divertor strike points in a disconnected DN configuration is important for understanding the overall power balance, as well as for optimizing the power exhaust performance and prolonging the survivability of the plasma facing components (PFCs). This power-sharing is typically evaluated in terms of the separation between the primary and secondary separatrices at the outboard midplane, $\textit {dR}_{\text {sep}}$. The Heat flux Engineering Analysis Toolkit (HEAT) is coupled with Brunner’s power fraction model to simulate the deposited heat flux and resultant temperature change on 3-D divertor targets in a dynamic DN (DDN) pulse operation in ST40, a high-field spherical tokamak. The simulation results showed that with DDN operation, the operation time has significantly increased compared with single-null geometry configurations.

ST40↗

Computationally inexpensive part-scale thermal history of additive friction-stir deposition

This study presents an analytical model for steady-state power generation and tool heat loss in additive friction-stir deposition (AFSD), developed to enable part-scale thermal simulation while remaining computationally inexpensive. The model predicts total generated power, yielding 3.7–4.7 kW across deposition temperature setpoints of 400–460 °C for the deposition of AA6061 with a Be-Cu tool. This corresponds to 90–95% of the reported spindle power. Tool heat loss is experimentally determined by calibrating a steady-state energy balance between the generated power, the substrate-deposition thermal gradient, and a temperature dependent tool heat loss term: q tool (T) = a + b (T - 400°C) with a = 2.7 x 10 6 Wm -2 and b = 9.5 x 10 3 Wm -2 K -1 . The calibration indicates that about 69% of the generated heat is conducted into the tool for this configuration, which is much higher than previously reported. The calibrated heat-source is implemented in finite element software (Adamantine) to simulate the transient thermal history of a 100 cm 3 representative build in 8 min on a standard desktop (at 0.635 mm build-height resolution). For the first three layers, the substrate temperatures between simulation and experiment are within 10% mean absolute percentage error. Sensitivity analysis indicates that uncertainties in average deposition temperature and deformation localization (stir-zone geometry, depth, and spatial dependance of strain-rate and flow stress) dominate model variance, motivating additional experimental verification.

Additive Friction-Stir Deposition↗

City-Scale Building Anthropogenic Heating during Heat Waves

More frequent and longer duration heat waves have been observed worldwide and are recognized as a serious threat to human health and the stability of electrical grids. Past studies have identified a positive feedback between heat waves and urban heat island effects. Anthropogenic heat emissions from buildings have a crucial impact on the urban environment, and hence it is critical to understand the interactive effects of urban microclimate and building heat emissions in terms of the urban energy balance. Here we developed a coupled-simulation approach to quantify these effects, mapping urban environmental data generated by the mesoscale Weather Research and Forecasting (WRF) coupled to Urban Canopy Model (UCM) to urban building energy models (UBEM). We conducted a case study in the city of Los Angeles, California, during a five-day heat wave event in September 2009. We analyzed the surge in city-scale building heat emission and energy use during the extreme heat event. We first simulated the urban microclimate at a high resolution (500 m by 500 m) using WRF-UCM. We then generated grid-level building heat emission profiles and aggregated them using prototype building energy models informed by spatially disaggregated urban land use and urban building density data. The spatial patterns of anthropogenic heat discharge from the building sector were analyzed, and the quantitative relationship with weather conditions and urban land-use dynamics were assessed at the grid level. The simulation results indicate that the dispersion of anthropogenic heat from urban buildings to the urban environment increases by up to 20% on average and varies significantly, both in time and space, during the heat wave event. The heat dispersion from the air-conditioning heat rejection contributes most (86.5%) of the total waste heat from the buildings to the urban environment. We also found that the waste heat discharge in inland, dense urban districts is more sensitive to extreme events than it is in coastal or suburban areas. The generated anthropogenic heat profiles can be used in urban microclimate models to provide a more accurate estimation of urban air temperature rises during heat waves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitization and Mechanical Response of Cu‐Containing Steel Rods

The iron and steel manufacturing sector significantly adds to global greenhouse gas emissions, caused primarily by the carbothermic reduction of iron ore. Recycling scrap steel offers an effective decarbonization strategy but introduces impurities like copper (Cu) that can negatively impact mechanical properties. This study investigates the effects of Cu content and heat treatment on the mechanical performance and sensitization of steel wire rods for tire manufacturing. Steel rods with 0.04 and 0.21 wt% Cu are heated to 1050 or 1200 °C, then air quenched, or furnace cooled. Tensile testing coupled with microscopic analysis is used to evaluate mechanical properties and assess the sensitization effects. Higher Cu content leads to larger sensitized zones with increased Cu precipitation along grain boundaries. Ductility and toughness, crucial for wire drawability, are found to be reduced, despite higher ultimate strength. Slower furnace cooling is seen to result in smaller sensitized zones compared to air quenching, suggesting a pivotal role of cooling rate in sensitization control. The findings provide insights into optimize heat treatment parameters and Cu content limits, balancing mechanical performance and maintaining drawability for enhanced scrap steel recycling in tire production.

copper↗

Boundary layer moisture variability at the Atmospheric Radiation Measurement (ARM) Eastern North Atlantic observatory during marine conditions

Abstract. Boundary layer moisture variability at the Eastern North Atlantic (ENA) site during marine conditions is examined at monthly and daily timescales using 5 years of ground-based observations and output from the European Center for Medium range Weather Forecast (ECMWF) reanalysis model. The annual cycle of the mixed-layer total water budgets is presented to estimate the relative contribution of large-scale advection, local moisture tendency, entrainment, and precipitation to balance the moistening due to surface latent heat flux on monthly timescales. When marine conditions prevail, advection of colder and dry air from the north acts as an important moisture sink (∼ 50 % of the overall budget) during fall and winter driving the seasonality of the budget. Entrainment and precipitation contribute to the drying of the boundary layer (∼ 25 % and ∼ 15 % respectively), and the local change in moisture contributes to a small residual part. On a daily temporal scale, moist and dry mesoscale columns of vapor (∼ 10 km) are analyzed during 10 selected days of precipitating stratocumulus clouds. Adjacent moist and dry columns present distinct mesoscale features that are strongly correlated with clouds and precipitation. Dry columns adjacent to moist columns have more frequent and stronger downdrafts immediately below the cloud base. Moist columns have more frequent updrafts, stronger cloud-top cooling, and higher liquid water path and precipitation compared to the dry columns. This study highlights the complex interaction between large-scale and local processes controlling the boundary layer moisture and the importance of spatial distribution of vapor to support convection and precipitation.

54 ENVIRONMENTAL SCIENCES↗

Optimal Design of Intensified Towers for CO2 Capture with Internal, Printed Heat Exchangers

Solvent-based carbon capture processes typically suffer from the temperature rise of the solvent due to the heat of absorption of CO2. This increased temperature is not thermodynamically favor-able and results in a significant reduction in performance in the absorber column. As opposed to interstage coolers, which only remove, cool, and return the solvent at discrete locations in the column, internal coolers that are integrated with the packing can cool the process inline, which can result in improved efficiency. This work presents the modeling of these internal coolers within an existing generic, equation-oriented absorber column model that can cool the process while allowing for simultaneous mass transfer. Optimization of this model is also performed, which is capable of optimally choosing the best locations to place these devices, such that heat removal and mass transfer area are balanced. Results of the optimization have shown that optimally placed cooling elements result in a significant increase in the capture efficiency of the process, compared to a similar column with no internal cooling, with a common trend being the cooling of the column in the temperature bulge region. It is observed that by optimally placing an internal cooler, the solvent flow rate can be decreased, and the CO2 lean loading can be increased while still maintaining the same efficiency. These process changes can lead to a substantial reduction in costs due to lower reboiler duty.

Summits, Stephen↗

Impacts of Wildfire Aerosols on Global Energy Budget and Climate: The Role of Climate Feedbacks

Aerosols emitted from wildfires could significantly affect global climate through perturbing global radiation balance. In this study, the Community Earth System Model with prescribed daily fire aerosol emissions is used to investigate fire aerosols’ impacts on global climate with emphasis on the role of climate feedbacks. The total global fire aerosol radiative effect (RE) is estimated to be -0.78 ± 0.29 W m -2 , which is mostly from shortwave RE due to aerosol–cloud interactions (REaci; -0.70 ± 0.20 W m -2 ). The associated global annual-mean surface air temperature (SAT) change ΔT is -0.64 ± 0.16 K with the largest reduction in the Arctic regions where the shortwave REaci is strong. Associated with the cooling, the Arctic sea ice is increased, which acts to reamplify the Arctic cooling through a positive ice-albedo feedback. The fast response (irrelevant to ΔT) tends to decrease surface latent heat flux into atmosphere in the tropics to balance strong atmospheric fire black carbon absorption, which reduces the precipitation in the tropical land regions (southern Africa and South America). The climate feedback processes (associated with ΔT) lead to a significant surface latent heat flux reduction over global ocean areas, which could explain most (~80%) of the global precipitation reduction. The precipitation significantly decreases in deep tropical regions (5°N) but increases in the Southern Hemisphere tropical ocean, which is associated with the southward shift of the intertropical convergence zone and the weakening of Southern Hemisphere Hadley cell. Such changes could partly compensate the interhemispheric temperature asymmetry induced by boreal forest fire aerosol indirect effects, through intensifying the cross-equator atmospheric heat transport.

54 ENVIRONMENTAL SCIENCES↗

Measurement and analysis of clothes dryer air leakage

Each year clothes dryer appliances are sold globally in the tens of millions. Both vented and ventless types are common and are heated by combustion, electric resistance, or electric heat pumps. In the dyer air path, segments can be defined between components such as the drum, blower, filter, screens or grills, and heat exchangers (where applicable). In this work, a technique was developed to experimentally measure air leakage into and from the segments of a clothes dryer. Detailed leakage measurements were taken on two vented and one ventless residential clothes dryer. The measurements were quantified as a leakage flow coefficient for each segment. For two dryers (one vented and one ventless), these flow coefficients were combined with in situ operating pressure measurements to determine leakage flow rates for each segment. For these two units under normal operation with air pressures within 0.5 kPa (50 mm water column) of ambient pressure, volumetric system air leakage was found to be about 20–60% of the blower airflow. Furthermore, a quasi–steady state psychrometric analysis was conducted on vented dryers with negatively pressurized drums. The analysis revealed that leakage quantity, location, and direction are essential to achieving an acceptable energy balance and accurate modeling results for a vented heat pump clothes dryer but are of limited significance for vented electric resistance clothes dryers.

42 ENGINEERING↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗

Catalytic and electrocatalytic performance of Sr(Ti 0.3 Fe 0.7 Ru 0.07 )O 3-δ for applications in solid oxide fuel cells supplied with ethanol steam reforming mixtures

We discuss how direct utilization of alcohols in Solid Oxide Fuel Cells (SOFCs) can improve the conversion efficiency by using excess heat for internal reforming and simplify the system balance of plant. Thanks to their scarce carbon- formation tendency, perovskite oxide anodes are promising alternatives to Ni-based cermets. Here we show that Sr(Ti 0.3 Fe 0.7 Ru 0.07 )O 3-δ (STF-Ru) exsolution anodes provide both catalytic reforming activity and electro- chemical activity with steam/ethanol (S/E) mixtures at 3:1 and 2:1 M ratio between 700 and 800 °C. Electrolyte- supported scandia stabilized zirconia SOFCs with STF-Ru anodes and Sr 0.95 Ti 0.3 Fe 0.7 O 3-δ (STF) cathodes are reasonably stable in the 3:1 S/E mixture over 20 h at 800 °C, with maximum power density of 195 mW/cm 2 and 140 mW/cm 2 at 0.7 V. Deactivation instead occurs with the 2:1 S/E mixture. Comparatively, cells with Ni-YSZ anodes rapidly coke and fail under the same conditions. Ethanol steam reforming experiments in a fixed bed powder reactor reveal that, above 650 °C, gas phase reactions convert ethanol to CO, hydrogen, acetaldehyde and ethylene, while STF-Ru catalyzes steam reforming. Thermogravimetric and Raman characterizations show that a moderate amount of carbon is deposited on the STF-Ru surface, which is more amorphous than the disruptive carbon which degrades Ni-YSZ.

09 BIOMASS FUELS↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermomechanical Stress and Creep-Fatigue Analysis of a High-Temperature Prototype Receiver for Heating Particles

This work presents a three-dimensional (3D) thermomechanical model of a prototype-scale enclosed light trapping solar receiver for heating particles. Results of the thermoelastic model are used to estimate receiver lifetime under maximum flux conditions. A computational fluid dynamics (CFD) model is first developed to predict the temperature fields in a multi-panel assembly under steady operating conditions. Solar flux distributions on the receiver are obtained from the software package SolTrace and applied to the 3D thermal model. The subsequent particle heating is captured through a simplified 1D energy balance. Panel reradiation is considered through a surface-to-surface radiation model and natural convection loss to the surrounding air is captured in a representative fluid domain surrounding the receiver. The resulting temperature fields from the CFD analysis are used as inputs for a thermoelastic mechanical model with representative boundary conditions. With the resultant temperature and stress fields, a creep-fatigue damage and lifetime analysis is performed using the linear damage accumulation (LDA) theory. The Manson-Coffin formula and Larson Miller correlation are used to calculate the fatigue and creep, respectively. A maximum damage (corresponding to a 30-year service life) is defined for design assessment. The model was first developed and verified in detail by comparing with published results in the literature (temperature and stress profiles and distributions, and creep/fatigue damage fractions) for tubular solar receivers with supercritical carbon dioxide as the working fluid. It was then implemented to model a planar-cavity receiver with various design parameters. Specifically, three different design geometries are considered, and the results show that a maximum temperature of approximately 1200 K could be reached for each design with the given incident solar flux, with the main difference being the distribution of these temperatures. Preliminary resulting stresses for the small-scale prototype without design optimization vary from 20 MPa to 250 MPa for each design, with the maximum stresses occurring on the front face and concave geometry on the side of the panel. In future work, the developed methodology shown here will be applied to analyze a full-scale (50-150 MWth) receiver.

concentrated solar power↗

Sensitivity Analysis Tool for Electrochemical Conversion of CO 2 To CO: User Guide

This is the user guide for the tool described here: Development of technologies that convert carbon dioxide (CO 2 ) into products is part of the U.S. Department of Energy's Office of Fossil Energy and Carbon Management Carbon Conversion Program portfolio. One such technology under development converts CO 2 to value-added products via electrochemical reduction, where catalysts are used on the cathode to promote CO 2 conversion across the electrochemical catalyst (ECC) cell. Broadly, the ECC is integrated with balance of plant (BOP) equipment (e.g., compressors, pumps, heat exchangers, purification units) in system configurations to produce the desired product. To guide research and development (R&D) toward advancements that may make such conversion technologies economically competitive, researchers may use sensitivity analyses related to the ECC system cost and performance, including that of the cathodic and anodic catalysts. This tool is intended to inform developers and Program in assessing proposed R&D on ECC systems early in the development process. Results will guide researchers on where efforts would be best directed. The tool may be accessed here: https://www.netl.doe.gov/energy-analysis/details?id=55293cb1-6881-4181-a2b0-d00b711ce74b.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiative heating rate profiles over the southeast Atlantic Ocean during the 2016 and 2017 biomass burning seasons

Marine boundary layer clouds, including the transition from stratocumulus to cumulus, are poorly represented in numerical weather prediction and general circulation models. Further uncertainties in the cloud structure arise in the presence of biomass burning carbonaceous aerosol, as is the case over the southeast Atlantic Ocean, where biomass burning aerosol is transported from the African continent. As the aerosol plume progresses across the southeast Atlantic Ocean, radiative heating within the aerosol layer has the potential to alter the thermodynamic environment and therefore the cloud structure; however, limited work has been done to quantify this along the trajectory of the aerosol plume in the region. The deployment of the first Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF1) in support of the Layered Atlantic Smoke Interactions with Clouds field campaign provided a unique opportunity to collect observations of cloud and aerosol properties during two consecutive biomass burning seasons during July through October of 2016 and 2017 over Ascension Island (7.96° S, 14.35° W). Using observed profiles of temperature, humidity, and clouds from the field campaign alongside aerosol optical properties from Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2), as input for the Rapid Radiation Transfer Model (RRTM), profiles of the radiative heating rate due to aerosols and clouds were computed. Radiative heating is also assessed across the southeast Atlantic Ocean using an ensemble of back trajectories from the Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model. Idealized experiments using the RRTM with and without aerosols and a range of values for the single-scattering albedo (SSA) demonstrate that shortwave (SW) heating within the aerosol layer above Ascension Island can locally range between 2 and 8 K d -1 depending on the aerosol optical properties, though impacts of the aerosol can be felt elsewhere in the atmospheric column. When considered under clear conditions, the aerosol has a cooling effect at the TOA, and based on the observed cloud properties at Ascension Island, the cloud albedo is not large enough to overcome this. Shortwave radiative heating due to biomass burning aerosol is not balanced by additional longwave (LW) cooling, and the net radiative impact results in a stabilization of the lower troposphere. However, these results are extremely sensitive to the single-scattering albedo assumptions in models.

54 ENVIRONMENTAL SCIENCES↗

Impact of Geothermal District Heating System on Flexibility of Microgrid in Tuttle, Oklahoma: Preprint

Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.

Cambium↗