Geothermal Heat Pump Case Study: Dallas-Fort Worth U.S. 287 Bridge

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Dallas-Fort Worth U.S. 287 Bridge and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

case study↗

Heat Pumps and Energy Recovering Ventilators in Northern Alaska

The intended purpose of this project was to bring alternative heat and ventilation options to rural communities off the road system in Northwestern Alaska. Most of the residents of these communities are reliant upon kerosene or other fossil fuels to provide heat to their homes. Our intention was to offer an alternative to using those sources by providing heat pumps to 45 homes in the communities of Elim and Koyuk. When projecting energy use for these units based on the fuel prices at the time, it was discovered that energy costs for heat pumps would equal or slightly exceed the costs of existing kerosene units. Secondly, as part of our E&l grant we installed 45 energy recovery ventilators (ERV’s) in those same homes. This was important given our experience over the years with moisture and comfort issues in most homes within this region. Exhaust-only systems are rarely used due to the high heating costs. Additionally, exhaust-only systems have a potential risk of back drafting due to tight building construction. Balanced systems like this eliminate that risk while improving indoor air quality. Another benefit to these types of systems is the fact that they help transfer heat from a single heat source equally throughout the building. Our overall goal was to offer new technology options to improve these structures and the families that reside in them where, given their location and extreme seasonal temperature swings, they have historically never been offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geothermal Heat Pump Case Study: PCC Austin Family Health Center

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on PCC Austin Family Health Center and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

geothermal↗

Geothermal Heat Pump Case Study: University of North Carolina Asheville

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on University of North Carolina Asheville and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

geothermal↗

Ground Source Heat Pump Screening Tool and Related Resources

This archive contains both a link to Oak Ridge National Laboratory's Ground Source Heat Pump (GSHP) Screening Tool and related resources documenting its development, technical features, and applications. The web-based screening tool is a techno-economic analysis resource designed to evaluate the feasibility, costs, and benefits of implementing GSHP systems in buildings across various U.S. climate zones. It is intended for use by building owners, HVAC system designers, and installers to support decision-making in residential and commercial applications, incorporating advanced modeling capabilities such as ground heat exchanger design. The included resources detail the tool's creation and use, covering topics such as innovative ground heat exchanger design methodologies, the development of an open library of g-functions for borehole configurations, and studies on GSHP performance and economic viability in retrofitting single-family homes.

15 GEOTHERMAL ENERGY↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) (Final Report)

This report is a final deliverable for project 81966: Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters (CRADA 625) Commercial heat pump water heater (CHPWH) systems can significantly improve the energy efficiency of service water heating (SWH), aka domestic hot water (DHW), in commercial and multifamily buildings but have not yet achieved widespread adoption due to pricing, complexity, and perceived risk factors. The goal of this project – Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial HPWHs (Scaling Up) – was to demonstrate and validate a holistic systems approach for CHPWHs that de-risks the technology, creating a reliable, cost-effective, and repeatable approach to CHPWH deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual-Functional Thermocapacitive Heat Pump with Electrochemical Supercapacitors for Building Thermal Management and Energy Storage

Efficient heating and cooling technologies can help reduce the energy consumption and carbon emissions of buildings. This work explores the use of supercapacitive cells in a multifunctional, liquid-regenerated thermocapacitive heat pump that can provide electrical energy storage in addition to heating and cooling. A proof-of-concept prototype based on eight commercial supercapacitors and using deionized water as a liquid regenerator demonstrated cooling and energy storage capabilities. A peak cooling coefficient of performance (COPc) of 0.27 was achieved at a temperature drop of 0.24 K. The highest measured electrical energy storage density of the cells was 5.93 J cm-3, and the highest cooling power delivered relative to the volume of the cells was 0.58 mW cm-3. This work demonstrates the use of electrochemical energy storage devices in multifunctional equipment for thermal management in buildings.

25 ENERGY STORAGE↗

Computational Simulation of a Water-Cooled Heat Pump

A Fortran-language computer program for simulating the operation of a water-cooled vapor-compression heat pump in any orientation with respect to gravity has been developed by modifying a prior general-purpose heat-pump design code used at Oak Ridge National Laboratory (ORNL).

Bozarth, Duane↗

Performance Evaluation of a Vapor-compression-cycle Based Heat Pump System for a Lunar Habitat under the Impact of Dust Deposits on the Coupled Radiators

Space exploration gains new momentum. A near goal is set by NASA to return humans to the Moon andestablish a sustainable presence on the lunar surface for more repeatable and affordable expeditions.The lunar dust is one of the dangerous environment hazard causing serious problems for explorationactivities. In this paper, in order to study the impact of lunar dust on the performance of a thermalmanagement system for a lunar habitat, a dynamical model of an active thermal control system that iscomprised of a vapor-compression cycle heat pump and a radiator loop is developed. A heat pump to liftthe heat rejection temperature is required due to high lunar daytime surface temperature. Parametricstudies on radiator size, percentage of dust coverage on the radiator, and lunar habitat location arecarried out. The results show that lunar deposits can significantly increase the power consumption ofthe thermal management system. A dust covered radiator panel results in net heat input to the heattransfer fluid during the period of strong solar irradiance, causing deteriorated performance of theradiator loop. The lunar dust contamination problem raises the requirement of redundancy design of asystem for fault tolerance. A synergetic design of a thermal management system, a power generationsystem and robotic maintenance system is proposed to achieve maximal mass cut for a whole lunarhabitat system.

Chunjian Pan↗

Investigation of a thermocapacitive cycle by aqueous supercapacitors for multifunctional heat pump and energy storage

Thermocapacitive cycles are promising thermal and energy storage cycles using supercapacitors, which can achieve thermal efficiencies over 50% of the Carnot limit. There is a lack of work investigating the use of thermocapacitive effects in practical heat pumps. Here, this paper explores the design of thermocapacitive cells with higher temperature changes to be better suited for heat pumping applications. To evaluate the cell designs on temperature changes, pouch type cells are prototyped and modeled, and tested using a micro-calorimeter. A peak adiabatic temperature span of a LiCl aqueous cell is 2.7 °C. By arranging the cells in a cascade manner, the projected adiabatic temperature span can reach up to 12 °C with a heating density of 15 kW m −3 and an energy storage density of 0.83 kWh m −3 . Models predict that this could be increased to 30 °C and 1.65 kWh m −3 through improvements to cell capacitance and thermopower. Incorporating the energy storage capabilities into heating and cooling devices can be beneficial to building thermal management as energy storage becomes increasingly important for energy system integration.

25 ENERGY STORAGE↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study and Development of an Air Conditioning System Operating on a Magnetic Heat Pump Cycle

This report describes the design of a laboratory scale demonstration prototype of an air conditioning system operating on a magnetic heat pump cycle. Design parameters were selected through studies performed by a Kennedy Space Center (KSC) System Simulation Computer Model. The heat pump consists of a rotor turning through four magnetic fields that are created by permanent magnets. Gadolinium was selected as the working material for this demonstration prototype. The rotor was designed to be constructed of flat parallel disks of gadolinium with very little space in between. The rotor rotates in an aluminum housing. The laboratory scale demonstration prototype is designed to provide a theoretical Carnot Cycle efficiency of 62 percent and a Coefficient of Performance of 16.55.

Wang, Pao-Lien↗

ResStock Measure Documentation: Cold Climate Air-Source Heat Pump

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Cold Climate Air-Source Heat Pump" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.