Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat pump modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Augmented Thermal Bus

The present invention is directed to an augmented thermal bus. In the present design a plurality of thermo-electric heat pumps are used to couple a source plate to a sink plate. Each heat pump is individually controlled by a model based controller. The controller coordinates the heat pumps to maintain isothermality in the source.

Schrage, Dean S.↗

Augmented thermal bus wih multiple thermoelectric devices individually controlled

The present invention is directed to an augmented thermal bus. In the present design a plurality of thermo-electric heat pumps are used to couple a source plate to a sink plate. Each heat pump is individually controlled by a model based controller. The controller coordinates the heat pumps to maintain isothermality in the source.

Schrage, Dean S.↗

Improved Design Tools for Surface Water and Standing Column Well Heat Pump Systems (DE-EE0002961)

Ground-source heat pump (GSHP) systems are perhaps the most widely used “sustainable” heating and cooling systems, with an estimated 1.7 million installed units with total installed heating capacity on the order of 18 GW. They are widely used in residential, commercial, and institutional buildings. Standing column wells (SCW) are one form of ground heat exchanger that, under the right geological conditions, can provide excellent energy efficiency at a relatively low capital cost. Closed-loop surface water heat pump (SWHP) systems utilize surface water heat exchangers (SWHE) to reject or extract heat from nearby surface water bodies. For building near surface water bodies, these systems also offer a high degree of energy efficiency at a low capital cost. However, there have been few design tools available for properly sizing standing column wells or surface water heat exchangers. Nor have tools for analyzing the energy consumption and supporting economics-based design decisions been available. The main contributions of this project lie in providing new tools that support design and energy analysis. These include a design tool for sizing surface water heat exchangers, a design tool for sizing standing column wells, a new model of surface water heat pump systems implemented in EnergyPlus and a new model of standing column wells implemented in EnergyPlus. These tools will better help engineers design these systems and determine the economic and technical feasibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Modelling and Performance Evaluation of a Chemisorption Heat Pump for Cold Climate

Space heating is a significant contributor to the energy consumption in residential buildings, especially in cold climates where electric-driven heat pumps lose the advantage of high efficiency and conventional gas-combustion furnaces have limited efficiency. Chemical adsorption (chemisorption) heat pumps (CSHP) have the potential for producing heating with high energy efficiency under cold operating conditions. A CSHP operates intermittently between desorption and adsorption modes, and their performance is affected by system design and transient system control. This study developed a dynamic model and used it to evaluate the daily system performance under different designs and controls, particularly the buffer tank size and the controlled minimum heating power. The simulation results revealed the effects of these parameters on the system performance and helped identify the optimal design and control for the highest coefficient of performance and heating capacity.

Yang, Zhiyao↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e.,53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Dual Fuel Heat Pump, Control, Residential Building↗

Energy Model to Evaluate Thermal Energy Storage Integrated with Air Source Heat Pumps: Preprint

Full decarbonization in buildings requires the replacement of combustion appliances with electric ones, and air source heat pumps (ASHP) are a candidate alternative. However, technical limitations, such as the efficiency decrease when operating in cold weather, limit their adoption in the global heating market. Among several options to improve ASHP efficiency operating in colder climates, thermal energy storage (TES) has been considered, as it may provide heating when it is cold and shift ASHP operation to times when the weather is warmer. It may also take advantage of time of use electricity rates and support defrosting when necessary. The evaluation of ASHP-TES systems, however, is still limited because traditional metrics do not capture their full economic and environmental benefits. In this work, a python framework is presented to model the ASHP with and without the presence of TES. Metrics are proposed to analyze the system performance in terms of costs, equivalent CO2 emission, and efficiency metrics to evaluate and compare alternative systems. Model validation against experimental data obtained for a commercial heat pump is provided, as well as an application example using Denver, Colorado, to highlight the model capabilities.

cold climate↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Size Up or Size Down? National Analysis of Heat Pump Sizing and Impacts

Electrification of on-site fossil fuel combustion in buildings is recognized as a key component of achieving global greenhouse gas emissions targets. Air-source heat pumps are an efficient approach for space heating electrification. However, a major barrier to heat pump adoption is the high installation cost relative to furnaces and air conditioners. Because the installation cost of heat pumps - especially cold climate models - is dependent on their size, it is important to understand the distribution of heat pump sizes using different sizing methods and factors that impact heat pump sizing. In this study, we use sub-hourly physics simulations of 550,000 statistically representative dwelling units to analyze the distribution of heat pump size in the U.S. for three different efficiency levels of heat pumps, with and without building insulation and air sealing upgrades. We will present results from the national analysis of different factors affecting heat pump sizing along with the impact of sizing decisions on upgrade costs and operating costs.

electrification↗

Modeling of a Membrane-Based Absorption Heat Pump

In this paper, a membrane heat pump is proposed and analyzed. Fundamentally, the proposed heat pump consists of an aqueous CaCl{sub 2} solution flow separated from a water flow by a vapor-permeable membrane. The low activity of the solution results in a net flux of water vapor across the membrane, which heats the solution stream and cools the water stream. This mechanism upgrades water-side low-temperature heat to solution-side high-temperature heat, creating a 'temperature lift.' The modeling results show that using two membranes and an air gap instead of a single membrane increases the temperature lift by 185%. The model predicts temperature lifts for the air-gap design of 24, 16, and 6 C for inlet temperatures of 55, 35, and 15 C, respectively. Membranes with lower thermal conductivities and higher porosities improve the performance of single-membrane designs while thinner membranes improve the performance of air-gap designs. This device can be used with a solar heating system which already uses concentrated salt solutions for liquid-desiccant cooling.

14 SOLAR ENERGY↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

Mathematical Modeling of Loop Heat Pipes with Multiple Capillary Pumps and Multiple Condensers: Stead State Stimulations - Part 1

Loop Heat Pipes (LHPs) have proven themselves as reliable and robust heat transport devices for spacecraft thermal control systems. So far, the LHPs in earth-orbit satellites perform very well as expected. Conventional LHPs usually consist of a single capillary pump for heat acquisition and a single condenser for heat rejection. Multiple pump/multiple condenser LHPs have shown to function very well in ground testing. Nevertheless, the test results of a dual pump/condenser LHP also revealed that the dual LHP behaved in a complicated manner due to the interaction between the pumps and condensers. Thus it is redundant to say that more research is needed before they are ready for 0-g deployment. One research area that perhaps compels immediate attention is the analytical modeling of LHPs, particularly the transient phenomena. Modeling a single pump/single condenser LHP is difficult enough. Only a handful of computer codes are available for both steady state and transient simulations of conventional LHPs. No previous effort was made to develop an analytical model (or even a complete theory) to predict the operational behavior of the multiple pump/multiple condenser LHP systems. The current research project offered a basic theory of the multiple pump/multiple condenser LHP operation. From it, a computer code was developed to predict the LHP saturation temperature in accordance with the system operating and environmental conditions.

Hoang, Triem T.↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Pump Water Heater Using Wrapped-Tank Microchannel Condenser Coil for Charge Reduction – FY19 1st Quarter (Regular) Milestone Report: Development of Wrapped-Tank Condenser Model (Round Tube and Microchannel), Coupled with Water Tank Model

We recently grew the DOE/HPDM model library to enhance its heat pump water heater (HPWH) design and simulation capability. The new additions include wrapped-tank round tube coil, microchannel coil and a one-dimensional stratified water tank. A wrapped-tank condenser coil has strong coupling with a stratified water tank, which leads HPWH simulation a transient process. The new one-dimensional stratified water tank model is an improvement to the open-source EnergyPlus water tank model, by introducing a calibration factor to account for bulk mixing effect due to water draws and circulations, etc. The wrapped-tank condenser coil model, using a segment-to-segment modeling approach to simulate round tubes or microchannel ports. The heat exchanger models can accept arbitrary refrigerant types, e.g. HFCs, HFOs, natural refrigerants like CO 2 and propane, etc.

42 ENGINEERING↗

Application of thermal energy storage with electrified heating and cooling in a cold climate

Ground source heat pumps (GSHPs) have been shown to be an effective means of decarbonizing building heating and cooling, but the operation of these systems at scale presents challenges to sites and the grid due to increases in peak demand. Here, in this study, we investigate how the use of Thermal Energy Storage (TES), in the form of stratified water storage, could reduce the peak daily demand associated with GSHP systems and thus improve their cost effectiveness. This system was compared to a Combined Heat and Power (CHP) plant, to investigate the potential cost and emissions impacts of electrification on large energy users transitioning from high efficiency fossil fuel equipment. This study builds on previous research by using a significant campus area, and investigating the various impacts of an electrified system versus a state of the art fossil fuel system. An established method of TRNSYS modeling is used for the heat pumps and borehole heat exchangers (BHEs), along with the TES. The GSHP system with TES is modeled to follow industry standards and sized to provide an optimal balance of capital and operating costs. Costs were investigated for a unique large energy user rate structure, as well as for a more common generalized rate structure. The results show that the addition of TES to the GSHP system could reduce operating costs by 4.5%, but still incurs a 5.64% cost increase from the baseline CHP system. It is also shown, however, that a tactical integration of heat pumps into the CHP system is the most cost effective solution, only increasing the operating costs by 4.71%. Likewise, the impacts of different rate structures are highlighted, with the TES only resulting in 0.75% cost savings under the generalized utility rate. Furthermore, it is shown that thermal storage has great potential for demand reduction, with the addition of storage incurring a decrease of 7–22% in annual peak demand kW, dependent on the rate structure.

25 ENERGY STORAGE↗

Open-source simulation platform for air source heat pump integrated with thermal energy storage

Here, this article introduces a modular simulation platform for assessing thermal energy storage (TES) integrated with air source heat pumps (ASHP). The Python platform is an open-source library that includes classes for modeling air-air and air-water heat pumps, TES devices, and the heating load of residential buildings. To validate the ASHP model, the study utilized experimental data obtained from a commercial heat pump evaluated at the National Renewable Energy Laboratory (NREL). The results indicate a mean deviation of 0.7% for COP across the operating range, with a maximum relative deviation of 12.6%. In terms of system heating capacity, the model had an average deviation of 4.3% compared to experimental results, with a maximum deviation of 8.2%. Three classes were implemented for modeling distinct types of TES devices: a generic TES based on energy balances, a sensible isothermal water tank, and a stratified water tank. Details of the mathematical models are provided, along with their respective strengths and limitations. An example is provided showcasing the integration of a residential 10 kWh thermal storage unit with an ASHP operating in Denver, CO. The comparison of two different discharge criteria for the TES unit highlights the importance of control strategies in the system performance.

25 ENERGY STORAGE↗