Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Testing of Helium Cooled Metal Molybdenum Disk Target System

NorthStar Medical Radioisotopes LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99) through a photonuclear reaction on molybdenum-100 (Mo-100). In this approach, multiple thin disks of enriched molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, we intend to use as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium atmosphere inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flow from one side, making the window design challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess as high a tensile strength as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and the high thermal stress from beam heating.

42 ENGINEERING↗

Testing of Helium-Cooled Metal Molybdenum Disk Target

NorthStar Medical Radioisotopes LLC is planning to produce an important medical radioisotope, molybdenum-99 (Mo-99), through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, it is desired to use as much beam power as possible to achieve maximum production yield and minimize target mass. This objective leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the main challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flowing on one side, making the window cooling even more challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess tensile strength as high as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and high thermal stress from beam heating. An Argonne team of scientists performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF) [3-7]. This report describes two series of tests for scale down production target designs that utilize full-scale 29 millimeters diameter, 0.75 mm thick press-and-sintered disks. We performed two thermal tests with different beam parameters and configurations of the disk laminations. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.

36 MATERIALS SCIENCE↗

Geothermal Direct-Use Applications for the District Energy System in Bucharest, Romania

The city of Bucharest, Romania, hosts the second-largest district energy system (DES) in the world. Geothermal resources can be considered as a supplementary heat source to support the demand for domestic hot water and space heating in the winter and shoulder seasons. The National Laboratory of the Rockies (NLR) has conducted a study that considers geothermal energy to serve a fraction of the existing district heating network operated by Electrocentrale Bucure?ti (ELCEN), the utility operating the DES. Lower Cretaceous and Jurassic limestones make up the main geothermal aquifer underlying Bucharest, which hosts temperatures suitable for district heating (up to 90 degrees C to the north of the city). Anomalous geothermal gradients have been observed to the north of the city, where a pumped well has produced 82 degrees C brine at the wellhead to feed the Therme Bucharest Spa. An anomalous gradient has also been reported to the southeast of the city (35 degrees C/km). NLR modeled the building heating loads of a small portion of the DES (a block of nine prototypical buildings) in its Urban Renewable Building and Neighborhood Optimization (URBANopt ) platform. To simulate meeting a baseload benchmark of 20 MWth deliverable to a small portion of the DES, the NLR team used GEOPHIRES to model production scenarios for (1) hydrothermal systems coupled with heat pumps targeting the main geothermal aquifer in the north, (2) enhanced geothermal systems targeting hot dry rock in the southeast, and (3) huff-and-puff systems targeting a gradient of 25 degrees C/km. Finally, NLR conducted a high-level sensitivity study around the techno-economics of these systems. The outcomes of this work indicate that hot dry rock geothermal resources that can deliver at least 90 degrees C hot water to the Geothermal District Energy System (GeoDES) offer a possible solution for supplemental geothermal heat delivered to the existing DES.

15 GEOTHERMAL ENERGY↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period April 2023 – September 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This fourth semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY23. As a part of the RCCS design task, recent efforts have been made to complete a conceptual design of the RCCS for the HC-HTGR, including the design update of the water panel and system configuration favorable in point of view of fabrication and system operation. Design calculations were conducted under various heat load conditions to validate the system design. Transient simulations using RELAP5-3D were conducted to investigate system dynamics under transients of interest and to evaluate the system performance in the design condition. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat sink. In the primary system thermal hydraulics task, the preliminary analysis was performed for a long term pressurized conduction cooldown (PCC) transient. This analysis used a combination of a fully resolved and coarse homogenized mesh to predict the temperature distribution for the steady-state initial condition and the PCC transient. The steady-state initial condition was determined using a fully resolved full core model with 3D solid to 1D fluid coupling. The fully resolved mesh was also used to model the first 20 seconds of the PCC. The temperature difference between fuel pins and the graphite matrix becomes minimal and the dominant heat transfer shifts to a larger scale radially towards the RCCS. After 20 seconds, a homogenized coarse mesh is used, greatly reducing the computational costs of the model. These results demonstrate that the core is designed to passively remove enough decay heat in a protected loss of primary coolant flow to prevent an unsafe rise of core temperatures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Control-oriented core-SOL-divertor model to address integrated burn and divertor control challenges in ITER

The real-time regulation of a burning plasma’s temperature and density, or burn control, will be necessary to produce high fusion power in future tokamaks like ITER. This is made more challenging due to the plasma’s nonlinear characteristics and the interdependence between the core-plasma and edge-plasma regions. For example, a raising plasma temperature leads to increasing reactivity and therefore to more alpha-particle heating, which further increases temperature. Furthermore, a raise of the fusion power increases the heat flow through the scrape-off-layer (SOL), which can compromise the integrity of the divertor without proper safeguards. For control design, a model-based approach is attractive because it can directly incorporate the nonlinear, coupled, burning-plasma dynamics into the design. To facilitate this design approach, a control-oriented core-SOL-divertor (CSD) model is presented in this work. In this CSD model, a core-plasma model captures the nonlinear dynamics of the core’s density and temperature, and a SOL-divertor model defines the plasma conditions at the separatrix and divertor including the heat load on the target plates. The core-plasma and SOL-divertor models are coupled through the exchange of various variables. In particular, the SOL-divertor model yields the separatrix temperature and the influx of recycled particles into the core-plasma. Further, these variables influence the power and particle balances captured by the core-plasma model. In return, the core-plasma model determines the intensity of the heat and particles fluxes across the separatrix, and this outflow strongly impacts the SOL-divertor model. Therefore, the power and density of the core-plasma, which can be readily modulated through external heating systems and pellet injection, can be viewed as control knobs for the SOL-divertor region in addition to the gas puffing. In simulations of the CSD model, it is demonstrated how external actuation can be utilized to meet burn control and divertor control objectives simultaneously.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Construction of Cryogen-Free 4.3T Superconducting Wiggler for NSLS-II Ring

With the 3 GeV electron beam energy for the National Synchrotron Light Source II (NSLS-II) ring, only superconducting wigglers (SCW) producing greater than 4T peak field can cover the photon energy range of 20 keV and 200 keV with sufficient number of photons. The High energy Engineering X-ray (HEX) Diffraction beamline, which is primarily funded by the New York State Energy Research and Development Authority (NYSERDA) and NSLS-II, will be equipped with a 1.2m-long SCW with 70 mm period length and 4.3 T on-axis field. This SCW is free from the use of liquid Helium and is cooled only with cryo-coolers. The Electron Beam Chamber (EBC) with vertical aperture of 8 mm is made from 316LN stainless steel and copper plating is applied both surface and +-12.5mm wide from the center in the inner surface. The expected heat load from the electron beam of the NSLS-II ring is estimated to be 10 W/m. Here, we describe the design principles and engineering challenges for the device.

36 MATERIALS SCIENCE↗

Innovative Thermal Strategies: Electrification's Best Friend

Because transportation and heat are the most significant contributors to greenhouse gas (GHG) emissions in the northern U.S., electrification of transport and heat are prominent elements of many decarbonization plans, such as that of New York State (NYS). A key challenge is then to decarbonize the electric supply and distribution system ("the grid") that supplies electricity, a process colloquially known as "greening the grid", so that the saved direct carbon emissions are not offset by additional indirect emissions from electrical generation on the grid. Applying this "simple" decarbonization plan to locations with high winter heating loads and modest renewable resources is challenging. Understanding the impact of thermal system design to grid demands in these locations and the related marginal power source for electrification options is critical to allocating proper resources to solve decarbonization challenges and quantifying the resultant carbon emissions impact.

battery storage↗

MPEX High Heat Flux Plasma Dump Design, Manufacture, and Articles Test

Here, the Material Plasma Exposure eXperiment (MPEX) device is a steady-state linear plasma device currently in the final design phase at the Oak Ridge National Laboratory. This device will reach ion fluences up to 10 31 m -2 and will be used to expose neutron-irradiated materials to divertor-relevant plasmas and to study the effects of plasma-material interactions. These studies will elucidate the complex effects of plasmas with divertor candidate materials capable of withstanding high heat flux and high fluences for next-generation fusion devices. Bidirectional plasma will be generated using a high-power (200 kW) helicon source. Plasma will be confined by superconducting magnets. The last plasma-facing component on the upstream side of the MPEX device is the dump, which has been designed to intercept plasma and energetic particles. The dump will have a total heat load of 9.2 kW. A copper alloy (Glidcop AL-15) was selected for use in the water-cooled flange design because of its high thermal conductivity, its retaining strength at elevated temperatures, and its ability to be used in the high-temperature braze joints used in this application. Titanium-zirconium-molybdenum (TZM) tiles are brazed to the Glidcop AL-15 flange using high-temperature braze alloy. External water-cooling channels are used on the dump flange to prevent water leakage inside the vacuum space. This article discusses the details of the high heat flux dump design, including the computational fluid dynamics (CFD) and structural analyses performed to validate the design to meet the operational requirements of the MPEX device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress towards edge-localized mode suppression via magnetic perturbations in hydrogen plasmas

Abstract The suppression of edge-localized modes (ELMs) by applying resonant magnetic perturbations (RMPs) is well studied in low collisionality deuterium plasmas as a measure to reduce transient divertor heat loads. However, ELM suppression has yet to be demonstrated in non-nuclear fuels such as hydrogen and hydrogen + helium mixtures which are the main ion species to be used in the ITER pre-fusion power operation (PFPO) phase. For the first time, attempts have been made to access ELM suppression with RMPs in ITER-like low collisionality hydrogen plasmas at DIII-D and ASDEX Upgrade. The DIII-D experiments focused on operation with injected power slightly above the L–H power threshold similar to the expected conditions in the ITER PFPO phase with limited external heating power. The RMPs were found to trigger H–L backtransitions, which is shown to be avoided by reducing the L–H power threshold by diluting the plasma with helium. The additional helium combined with a larger measured neutral density of hydrogen inside the separatrix compared to ELM suppressed deuterium plasmas precluded access to a pedestal top density below the known RMP-ELM suppression threshold. At ASDEX Upgrade, RMP-ELM suppression has been achieved when the concentration of 1 H in the hydrogen isotope mix is below 40 % . While all known access criteria for RMP-ELM suppression were met above this threshold, full ELM suppression was replaced by strong mitigation. The most prominent difference between the hydrogen and deuterium plasmas was a change of turbulence characteristics in the pedestal where Doppler reflectometry measurements suggest a significant reduction of turbulence even at small hydrogen concentrations. In conclusion, these experiments not only identify issues that may prevent access to RMP-ELM suppression in the ITER PFPO phase, but also highlight missing physics in our current understanding of RMP-ELM suppression such as potentially the role of turbulence in the pedestal gradient region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-Dimensional Heat Flux and Thermal Analysis of Angled Tungsten Samples on DIII-D

ITER-grade tungsten and dispersoid-strengthened tungsten samples with the top surface angled at ~15° towards the incident plasma flux were exposed to 9 H-mode discharges with edge-localized modes (ELMs) in the lower divertor of DIII-D tokamak using the Divertor Material Evaluation System (DiMES). Surface damage included cracking and flaking of material on the two samples farthest away from the plasma strike point, and significant melting of the two samples closest to the strike point. Heat flux and thermal analysis tools new to DIII-D have been applied to better understand this material response and to help optimize the exposure conditions for future experiments. SMITER field-line tracing simulations based on IRTV data and EFIT equilibria estimate an average inter-ELM perpendicular heat flux, 𝑞⊥,𝑖nter−𝐸LM , on the angled surfaces of 10.1 – 19.6 MW/m² for a majority of the 9 discharges, increasing to 15.6 – 24.5 MW/m² for the single, higher-power shot where samples melted. Fast camera data showed shallow intra-ELM melting and re-solidification, which transitioned to bulk inter-ELM melting with melt motion in the 𝐽⃗ 𝑥 𝐵⃗ direction. About 50% of the protruding volume of the most affected sample was displaced via melt-motion. SIERRA thermal modeling software was able to reproduce an onset time of melting consistent with fast camera data and final sample conditions, within < 200 ms. Maximum surface temperatures of 3122 K and 2787 K are estimated for the samples farthest away from the strike point, while the closest samples achieve melting at 4067 ms and 4750 ms into the ~5000 ms plasma exposure. A +10% increase in both the SMITER 𝑞⊥,𝑖nter−𝐸LM calculations and the estimated ELM heat loads 𝑞⊥, 𝐸LM was required to achieve this result, which is within the uncertainty of the diagnostic data but likely accounts for non-ideal geometry effects plus other physics uncertainties not included in this first iteration of modeling. This work provided valuable estimates of the 3D temperature evolution to help better understand the observed surface morphology and internal recrystallization of samples, which are discussed in detail in a complementary manuscript [1]. Benchmarking efforts with more diagnosed DIII-D experiments are underway to further refine the SMITER and SIERRA models for DiMES. Future use of these tools will enable researchers to precisely target heat flux exposure conditions in DIII-D to test, but not exceed, the thermomechanical limitations of novel plasma-facing materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The infrared imaging video bolometer at Wendelstein 7-X

The radiated power distribution is a crucial aspect of heat transport, heat load mitigation, and plasma exhaust performance. An imaging video bolometer camera has been installed to measure the plasma radiated power in the divertor region of the Wendelstein 7-X (W7-X) stellarator. This diagnostic offers a wide-angle (40° × 68°) sampling of the plasma volume in both the poloidal and toroidal directions. The field-of-view is covered with a large number (> 500) of bolometer channels, providing imaging capability. The diagnostic design is introduced here together with its data analysis procedure. A set of laboratory experiments is performed to assess the thermal properties of the gold absorber foil and their spatial uniformity. Following installation, a heat source originating from the inertially cooled front of the diagnostic is identified and filtered out. The discharge data indicate a satisfactory signal-to-noise ratio as well as spatiotemporal resolution. These represent the first toroidally resolved images of the line-integrated radiated power in the W7-X island divertor. The diagnostic was then upgraded with a thinner platinum absorber and adjusted mirrors. Early data from the most recent experimental campaign employing the upgraded design show a considerable improvement in the diagnostic performance with more bolometer channels (> 1400), extended coverage, and increased spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The physics basis to integrate an MHD stable, high-power hybrid scenario to a cool divertor for steady-state reactor operation

Abstract Coupling a high-performance core to a low heat flux divertor is a crucial step for ITER and a Fusion Pilot Plant or DEMO. Experiments in DIII-D recently expanded the steady-state hybrid scenario to high density and divertor impurity injection to study the feasibility of a radiating mantle solution. This work presents the physics basis for trade-offs between density, current drive and stability to tearing modes (TMs) at high β. EC power is crucial to tailor the plasma profiles into a passively stable state, and to eject impurities from the core. Off-axis EC depositions decrease the heating efficiency, but calculated electron heat transport coefficients show that this effect is partially mitigated by improved confinement inside the EC deposition. Additionally, the reduction in pressure is recovered by increasing the density. This favourable scaling of confinement with density was observed in high power plasmas for years, and this work provides a comprehensive explanation. ELITE predictions indicate that a path in peeling-ballooning stability opens up for certain conditions of density, power, q 95 and shaping, allowing the edge pressure to continue increasing without encountering a limit. In the core, calculated anomalous fast-ion diffusion coefficients are consistent with density fluctuation measurements in the toroidicity-induced Alfvén eigenmode range, showing that smaller fast-ion losses contribute to the enhanced confinement at high density. The edge integration study shows that divertor heat loads can be reduced with Ne and Ar injection, but this eventually triggers a cascade of n = 1, 2, 3 core TMs. We can now show that impurity radiation in the core is small and it is not the cause for the drop in confinement at high Ar and Ne injection rates. The overlap between the core TMs is consistent with the loss of pressure as estimated by the Belt model for the coupled rational surfaces. Optimization of these trade-offs has achieved plasmas with sustained H 98y2 = 1.7, f GW = 0.7 and ∼85% mantle radiation. The scenario and its variations at higher density and on- vs off-axis EC heating has been studied as a candidate for an integrated solution for several reactor designs, such as ITER, ARC, and the ARIES-ACT1 case, showing promising results in terms of fusion power and gain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Preliminary neutronic and thermal analysis of Inertial Fusion Energy systems with a focus on thick liquid wall concepts

This paper provides an assessment of the neutronic behavior of Inertial Fusion Energy systems using the Serpent 2 Monte Carlo code. The study explores different types of reactor concepts, including dry-wall and thick liquid wall systems. In particular, it characterizes the tritium breeding and energy multiplication performance, as well as the effect of long-term irradiation on structural materials. For this purpose, the displacement per atom (DPA) and the gas production rate in structural materials are calculated. A simplified geometry with varying geometrical parameters is used as a representation for the different kinds of devices. Additionally, the case of the HYLIFE-II concept is used to assess modeling inaccuracies arising from certain approximations. A comparison between the simplified geometry and a realistic one is performed, thanks to Serpent’s capability to run transport calculations on unstructured meshes. The study then addresses the impact of these discrepancies on the temperature distribution in the first wall using the GeN-Foam code for conjugate heat transfer analysis. The results highlight the necessity to consider the heterogeneous nature of the liquid wall, as simplified models tend to underestimate radiation damage metrics and heat loads.

Conjugate heat transfer↗

FY22 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY22. As an extension of the effort from FY21, this year’s work focuses primarily on the two-phase modeling of the NSTF using RELAP5-3D, particularly with the inclusion of the cavity model. The results from simulations were used to compare against experimental data for benchmarking purposes of the RELAP5 deck. Additionally, RELAP5 was used as a predictive tool to guide planned test operations and identify expected system behaviors. In the first part of this report, details are provided of the cavity omitted model where heat flux is applied directly as a boundary condition to the risers. The general trend predicted by the RELAP5 model matches that from the experimental data when a single-phase natural circulation flow is first established, followed by an oscillatory two-phase period and finally a stable two-phase flow. However, the onset of oscillations is predicted early by the model due to the smaller thermal mixing region in the tank. However, by expanding the simulated thermal mixing region in the tank, the onset of oscillations predicted by the model is able to match that from the experiment. These oscillations where studied in depth and are deduced to be flashing-induced instability. The model was then modified to simulate an accident scenario case where a representative heat load based on the full-scale Framatome’s 625 MW t SC-HTGR was applied directly to the riser channels. The simulated initial and boundary conditions were identical to those performed experimentally, facilitating direct comparisons between the predicted and experimental results. It was determined that the results showed some discrepancies remain, likely due to the overprediction of vapor generation rate by the computer model. In the second part of this report, the cavity model is re-introduced where it is observed that the RELAP5 prediction is now able to capture the major trends of the observed flow commonly observed during two-phase conditions. However, the onset of oscillations is once again predicted early by the model, possibly caused by the underprediction of heat loss from the heater and cavity. This is likely due to the omission of support structures in the cavity that can act as additional pathways for heat to escape to the environment. To overcome the underprediction of heat loss, part of the insulation surrounding the cavity side panels and the back of the heaters are removed to allow heat to escape directly to the environment, which then improves the RELAP5 prediction. Parametric studies are also performed to investigate the effects of heater power, tank inventory level, and tank gas space pressure on flow behaviors, also in direct comparison to conditions tested experimentally. User option-61 in the RELAP5-3D input deck, which changes the heat transfer coefficient correlations used for calculating the vapor generation, is also investigated where it is found that by enabling the option, the overall duration of oscillations is increased and matches that from the experiment better. The RELAP5 model is further benchmarked with a header inlet- throttling case where it is observed that the prediction from the model fails to capture some major features observed in the experiment. By using a modified loss coefficient curve for the valve, the accuracy of the prediction is improved where most of the major features observed in the experiment are predicted by the model. Lastly, the model is benchmarked with an inventory depletion scenario where it is observed that despite the modeling limitation of RELAP5, the prediction shows good agreement with the experimental data where major trends and features are captured by the model. Future work will see continued development of the current RELAP5-3D input deck of the NSTF to both improve the accuracy of the model’s predictive capability and continuing serving the experimental program. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Stable heat and particle flux detachment with efficient particle exhaust in the island divertor of Wendelstein 7-X

The island divertor concept is an innovative and promising idea to handle heat and particle exhaust in stellarators. At the Wendelstein 7-X (W7-X) stellarator, this divertor concept plays a central role in the device mission to demonstrate reactor relevant plasma confinement for steady-state time scales of up to 30 minutes in the high-performance campaign (OP2) starting in 2022. During the recently concluded first campaign with the inertially cooled island divertor, a large step in the experimental qualification of this divertor concept has been made. In discharges heated with electron cylotron resonance heating of 5-6 MW, central densities in the range of 0.7-1.2 × 10 20 m -3 have been reached in combination with full divertor heat flux detachment. Also, significant neutral gas pressures and neutral compression ratios were shown for the first time in combination with reduced divertor particle flux. The divertor heat loads drop by an order of magnitude from >5 MW m -2 to below 0.5 MW m-2 with increasing density, and substantial compression of neutrals reaching neutral pressure in the sub-divertor volume of >6.0 × 10 -4 mbar was seen. These elevated neutral pressure levels can be obtained and maintained with an up to 80% reduction of the particle fluxes onto the divertor target tiles. This discharge scenario was held stably detached for up to 28 seconds, which is equivalent to several hundred energy confinement times τ E and longer than the time scales for current relaxation. No impurity accumulation was seen at constant Z eff ≈ 1.5 and the stored energy stayed constant at levels of W dia >600 kJ. The level of neutral pressure and compression reached in this scenario extrapolates well to the steady-state particle exhaust requirements for high-performance steady-state operation in OP2, in which the fully actively cooled high-heat-flux divertor will be available. Finally, an overview of this recently discovered divertor regime is given and the status of the physics understanding based on modeling of these regimes with the EMC3-EIRENE code is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Edge localized mode characteristics and divertor heat flux during stationary and transient phase for CFETR hybrid scenario

The study of edge localized mode (ELM) behavior, stationary heat flux and transient heat flux during the ELM crash phase is performed for a China Fusion Engineering Test Reactor (CFETR) 1 GW hybrid mode operation scenario ($R$ = 7.2 m, ${B_{\text{T}}}$ = 6.5 T, ${I_{\text{p}}}$ = 13.78 MA). Modeling and simulation start with a scenario obtained by multi-code integrated modeling on the one modeling framework for integrated tasks framework. Linear stability and nonlinear simulations of ELM dynamics are carried out using the BOUT++ six-field reduced magnetohydrodynamic module, which show a much smaller ELM energy loss (Δ ELM ~ 0.13%) compared to that of a Type-I ELM. Parametric analysis of the weak linear growth rate and small ELM energy loss characteristics shed light on physics corresponding to a grassy ELM regime for CFETR 1 GW hybrid scenario. The transient heat flux on the divertor target during this small ELM phase is investigated using BOUT++. Here we found that upstream radial transport in the scrape-off-layer (SOL) induced by small ELMs is weak, which keeps it in the drift-dominated region. However, the heat flux width is still broadened to ${\lambda _{\text{q}}}$ = 4.64 mm by the increase of separatrix temperature during ELM nonlinear evolution. The impact of transient peak heat load and ELM energy fluence on tungsten melting and net erosion rate of divertor target is evaluated for the first-time using physics-based transport that connects the pedestal with the SOL. Energy fluence caused by a single ELM pulse is below the tungsten melting limit, while tungsten erosion would exceed the material requirements. We conclude that external mitigation methods, such as divertor detachment and advanced divertor geometry are likely needed for the steady state operation of CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of 3D MHD simulations of Ne/D 2 mixed shattered pellet injection in JET

Nonlinear 3D magnetohydrodynamic (MHD) modeling of shattered pellet injection (SPI) in JET tokamak plasmas is performed with the JOREK code. The study focuses on the validation of simulation result with respect to experimental observations, addressing in particular figures of merit for the efficiency of the SPI, as a technique to mitigate thermal loads by injecting radiative impurities like neon during the thermal quench (TQ) phase of disruptions. A set of JET pulses with neon/deuterium atomic mixture ratio in the shattered pellet varying from 10% to 100% provides the experimental data to be compared with. Simulations using different models for the ablation of solid fragments and the radiation of neon impurities are considered. Synthetic diagnostics are employed for a direct quantitative comparison with key JET diagnostic systems providing in particular radiation, electron temperature and density, and magnetic measurements. 3D radiation structures from MHD simulations are analyzed to estimate the toroidal asymmetry of radiation, which is difficult to measure in JET due to the presence of only two toroidally displaced multi-channel bolometry systems. JOREK simulations show that, before the TQ, the bulk of the radiation is concentrated in a toroidal region enclosing the radiating fragments that is missed by both multi-channel bolometers, suggesting a possible underestimation of the total radiation by such diagnostic systems in the pre-TQ phase. On the other hand, JOREK predicts that during the TQ the radiation becomes more toroidally symmetric, with positive implications for the heat load to plasma facing components.

JOREK↗