Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Mechanistic Study of Nucleate Boiling Heat Transfer Under Microgravity Conditions

Experimental studies of growth and detachment processes of a single bubble and multiple bubbles formed on a heated surface have been conducted in the parabola flights of KC-135 aircraft. Distilled water and PF5060 were used as the test liquids. A micro-fabricated test surface was designed and built. Artificial cavities of diameters 10 microns, 7 microns and 4 microns were made on a thin polished Silicon wafer that was electrically heated by a number of small heating elements on the back side in order to control the surface superheat. Bubble growth period, bubble size and shape from nucleation to departure were measured under subcooled and saturation conditions. Significantly larger bubble departure diameters and bubble growth periods than those at earth normal gravity were observed. Bubble departure diameters as large as 20 mm for water and 6 mm for PF5060 were observed as opposed to about 3 mm for water and less than 1 mm for PF5060 at earth normal gravity respectively. It is found that the bubble departure diameter can be approximately related to the gravity level through the relation D(sub d) proportional 1/g(exp 1/2). For water,the effect of wall superheat and liquid subcooling on bubble departure diameter is found to be small.The growth periods are found to be very sensitive to liquid subcooling at a given wall superheat. However,the preliminary results of single bubble dynamics using PF5060 showed that the departure diameter increases when wall superheat is elevated at the same gravity and subcooling. Growth period of single bubbles in water has been found to vary as t(sub g) proportional g(exp -.93). For water, when the magnitude of horizontal gravitational components was comparable to that of gravity normal to the surface, single bubbles slid along the heater surface and departed with smaller diameter at the same gravity level in the direction normal to the surface. For PF5060, even a very small horizontal gravitational component caused the sliding of bubble along the surface. The numerical simulation has been carried out by solving under the condition of axisymmetry, the mass, momentum, and energy equations for the vapor and the liquid phases. In the model the contribution of micro-layer has been included and instantaneous shape of the evolving vapor-liquid interface is determined from the analysis. Consistent with the experimental results, it is found that effect of reduced gravity is to stretch the growth period and bubble diameter It is found that effect of reduced gravity is to stretch the growth period and bubble diameter at departure. The numerical simulations are in good agreement with the experimental data for both the departure diameters and the growth periods. In the study on dynamics of multiple bubbles, horizontal merger of 2,3 4,and 5 bubbles was observed. It is found that after merger of 2 and 3 bubbles the equivalent diameter of the detached bubble is smaller than that of a single bubble departing at the same gravity level. During and after bubble merger, liquid still fills the space between the vapor stems so as to form mushroom type bubbles. The experimental and numerical studies conducted so far have brought us a step closer to prediction of nucleate boiling heat fluxes under low gravity conditions. Preparations for a space flight are continuing.

Dhir, V. K.↗

Dispatch optimization of electric thermal energy storage within System Advisor Model

A stand-alone electric thermal energy storage (ETES) system converts low-value electricity into heat using resistance heating elements. During periods of high-value electricity, an ETES system uses a thermodynamic power cycle to convert stored thermal energy back to electricity. These dispatchable systems derive value from their ability to store energy when prices are low and generate electricity when prices are favorable, i.e., energy arbitrage. Consequently, dispatch optimization of system operations, through maximizing revenue subject to system constraints, is essential to evaluate the economic value of a particular system design. While stand-alone ETES systems offer potential advantages as dispatchable grid storage technologies, there is a lack of a neutral third-party, publicly available, open-source model to evaluate the performance, dispatch, and financial viability of these systems. To address this problem, we have developed a techno-economic model for stand-alone ETES systems, within National Renewable Energy Laboratory's (NREL's) System Advisor Model (SAM). We implement a mixed-integer linear program to determine an ETES optimal operating schedule that maximizes electricity sales less maintenance costs caused by operation and cycling given temporal-varying grid electricity prices. Our contributions include a mixed-integer linear program for energy arbitrage of an ETES system, an ETES performance model through a publicly-available software (i.e., SAM), and an exercise of our model through case studies that compare ETES operational strategies and annual financial metrics. With our dispatch optimization model, we were able to improve revenue by 20% compared to a myopic heuristic while reducing the operational cost of the ETES system through decreases in cycle starts, cycles per day, and heater starts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced joining strength in additive-manufactured polylactic-acid structures fused by embedded heated metallic meshes

Additively manufactured thermoplastic polymers, such as polylactic acid (PLA), hold significant promise for sustainable engineering structures, including wind turbine blades. Upscaling these structures beyond the limitations of 3D printer build volumes is a challenge; fusion joining presents a potential solution. This paper introduces a displacement-controlled resistance welding process for PLA, as an alternative to the typical force-controlled methods. Here, we investigated the bonding quality of resistance-welded and adhesive-bonded PLA beams through three-point bending and measured the surface deformations using digital image correlation. Different metal meshes (30%/0.11 mm Ni—Cu, 34%/0.07 mm Ni—Cu, and 36%/0.25 mm Co—Ni) served as heating elements. The process parameters were varied for the 34%/0.07 mm Ni—Cu mesh to identify an optimum set of parameters. Results showed that this optimized displacement-controlled welding achieved 94% of the original strength of monolithic samples. This indicates that the new welding process not only ensures high-quality bonding and fine surface finishing but also promotes sustainability, recyclability, and economic efficiency in various polymer and composite structural applications.

Additive manufacturing↗

Improving Data and Prediction Quality of High-Throughput Perovskite Synthesis with Model Fusion

Combinatorial fusion analysis (CFA) is an approach for combining multiple scoring systems using the rank-score characteristic function and cognitive diversity measure. One example is to combine diverse machine learning models to achieve better prediction quality. In this work, we apply CFA to the synthesis of metal halide perovskites containing organic ammonium cations via inverse temperature crystallization. Using a data set generated by high-throughput experimentation, four individual models (support vector machines, random forests, weighted logistic classifier, and gradient boosted trees) were developed. We characterize each of these scoring systems and explore 66 possible combinations of the models. When measured by the precision on predicting crystal formation, the majority of the combination models improves the individual model results. The best combination models outperform the best individual models by 3.9 percentage points in precision. In addition to improving prediction quality, we demonstrate how the fusion models can be used to identify mislabeled input data and address issues of data quality. In particular, we identify example cases where all single models and all fusion models do not give the correct prediction. Experimental replication of these syntheses reveals that these compositions are sensitive to modest temperature variations across the different locations of the heating element that can hinder or enhance the crystallization process. In summary, we demonstrate that model fusion using CFA can not only identify a previously unconsidered influence on reaction outcome but also be used as a form of quality control for high-throughput experimentation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of a lightning protection system for a fusion-welded thermoplastic composite wind turbine blade tip

Fusion welding for thermoplastic composite wind turbine blades is being investigated as a replacement for adhesives in bond lines to reduce manufacturing time and cost and to promote ease of recyclability. Resistance welding uses an electrically conductive material, such as carbon fiber, embedded in the bond line to heat the joining surfaces and fuse them together under pressure. One main challenge with fusion joining for large wind blades is the ability to use this conductive heating element in the bond line while still protecting the blade from the catastrophic effects of a lightning strike. This paper outlines the design and manufacturing of a lightning protection system for a 5-m-long thermally welded blade tip. The outcomes of high voltage and high current lightning testing applied to the 5 m blade tip show that the proposed design was able to protect the fusion welded bond lines from significant lightning damage.

17 WIND ENERGY↗

Physical Modeling of Coupled Thermohydraulic Behavior of Compacted MX80 Bentonite during Heating

Abstract This paper describes a tank-scale test setup and experimental methodology used to investigate coupled heat transfer and water flow processes during heating of compacted MX80 bentonite to high temperatures. Specifically, a temperature of 200°C was maintained by a cylindrical heating element at the center of a compacted bentonite layer containing an array of temperature, dielectric, and relative humidity sensors. In addition to providing an evaluation of the spatiotemporal variations in temperature, relative humidity, degree of saturation, and global volume, the coupled thermohydraulic properties of the bentonite were assessed. A wetting front was initially observed to move away from the central heater, followed by a drying process until reaching thermohydraulic equilibrium. The soil–water retention curve (SWRC) of the bentonite followed a wetting scanning path before following the primary drying path exhibiting a shift in water retention with elevated temperature. Results from the tank-scale test can be used for validation of numerical simulations of drying processes in the engineered barrier system of a high-level radioactive waste geological disposal repository and confirm that a temperature-dependent hysteretic SWRC with scanning paths is required to accurately capture the bentonite response.

Engineering↗

In-Situ Spatial Mapping of Hydrogen in Yttrium Hydrides at LANSCE (FY23 Version, Rev. 1)

This report summarizes the development of neutron imaging capabilities and experimental activities performed at the Los Alamos Neutron Science Center (LANSCE) with the main goal of measuring temperature-driven hydrogen diffusion within bulk-yttrium hydride (YH x ) materials. Yttrium hydride is the leading candidate to serve as a solid neutron moderator in microreactor cores, owing to its high density of hydrogen atoms as well as its superior thermal stability compared to all other metal hydrides. The experimental results and technique developments reported herein support the U.S. Department of Energy Office of Nuclear Energy’s (DOE-NE) Microreactor Program under Technology Maturation. In particular, it addresses the critical need to experimentally validate and verify hydrogen-diffusion models of metal hydrides used in high-temperature microreactor designs by means of high-spatial-resolution neutron imaging. These capabilities were designed to apply large temperature gradients across centimeter-sized YH x pellets to simulate conditions faced in the microreactor environment. In principle, neutron imaging, combined with in-situ sample heating, enables near real-time tracking of hydrogen diffusion in YH x on the sub-millimeter scale. In this report, an overview of neutron imaging methodology and technologies are given in the context of recent spatial measures of hydrogen concentrations in similar metal hydrides. Additionally, the commissioning and operation of a custom-built compact dual-zone furnace is given along with details on three in-situ heating measurements of YH x performed over the 2020 to 2022 LANSCE operation cycles. The aims of these experiments ranged from furnace commissioning, determining sample quality, i.e., hydrogen uniformity via neutron computed tomography, and studying the effects of applied temperature-gradients on YH x pellets. Analyses and results from these neutron imaging measurements are given along with outlooks and guidelines for optimal future hydrogen diffusion measurements. Our conclusions are as follows. Image analyses indicate that centimeter-sized yttrium hydride cylindrical pellets exhibit uniform, whole-body hydrogen desorption and absorption without clear temperature dependence as reflected in the image attenuation at the opposing ends of each sample. This suggests that despite the large magnitude in temperature gradients applied by the furnace heating elements, the sample equilibrates to an unknown intermediate temperature. The origin of this result is likely the combination of short sample length (∼1cm) and use of a TZM can for containment where the latter created a thermal short across the sample. Nevertheless, the results from the most recent measurements indicate that neither significant concentration gradients of hydrogen were formed in centimeter-sized samples through the entire temperature range (25 °C to 950 °C) nor any formed due to temperature gradients on the order of 50 °C/cm up to 700 °C/cm. Furthermore, images from the FY2021 and FY2022 measurements indicate that samples of YH x , fabricated from either the direct hydride or powder metallurgy methods, are highly uniform in their hydrogen concentration to within the measurements’ spatial resolutions. The following questions arise from these latest results: 1) What is the intermediate temperature of the pellets in the TZM cans? 2) How quickly does the temperature equilibrate within the sample? and, 3) Do the observed changes in image attenuation follow known pressure-composition-temperature relations of yttrium hydride?

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FEM Modeling and Simulation of 2-D High Specific Heat Nb 3 Sn Wires

In the past few years, new high specific heat Nb 3 Sn wires have gained much focus at FNAL. Indeed, they have proved to be more stable against thermal perturbations with respect to standard wires. Nevertheless, a trade off exists between their thermal efficiency and production feasibility. In this report I describe the thermal and structural models that I have developed by exploiting ANSYS Mechanical APDL ® , which I got acquainted with at the beginning of my training. The aim has been to optimize the location of high specific heat elements in order to obtain an optimal thermal stability, while minimizing the risk of wire breakage during drawing. FEM results are compared with experimental ones made beforehand. Other minimum quench energy (MQE) thermal models have been developed for expected new experimental results. New data may improve the understanding of the embedded physical uncertainties in the model.

36 MATERIALS SCIENCE↗

Assessment of MiniFuel Subcapsule Design Recommendations on Previous Experiments

MiniFuel describes the class of separate effects nuclear fuels irradiation experiments that have been conducted in the High Flux Isotope Reactor (HFIR) since 2018. These experiments comprise a stack of six fuel-bearing subcapsules contained in a stainless steel target housing that is in contact with HFIR coolant on its exterior. All MiniFuel targets have a near-standardized architecture, and the primary design variables that change between experiments are the radial gap size between the subcapsule and housing and the target fill gas composition. Finite element heat transfer models are used to determine the optimum gas composition and gap sizes, and recent studies were performed to identify model parameters that contribute the most uncertainty to fuel specimen temperature predictions. That work, which is referenced herein, also recommended a set of design modifications to the subcapsule internal architecture and assembly process. These modifications are intended to reduce fuel temperature uncertainty in future experiments. In this report, the subcapsule design modifications were retroactively applied to a previously conducted MiniFuel experiment to determine how these changes affect the established safety and performance envelope of the experimental capability. These effects were determined in two steps. First, the modifications were applied to the subcapsule design without any other changes to determine their isolated effect on the predicted fuel specimen temperatures. This portion of the analysis showed that fuel temperatures were modestly reduced because the implemented changes improved heat transfer efficacy. Next, traditional MiniFuel design activities (i.e., sizing the gas gaps and determining the fill gas composition) were reperformed, and they confirmed that the original desired fuel temperatures could be achieved while remaining within established safety limits. Therefore, this report demonstrates improved performance resulting from the subcapsule modifications, which mitigate uncertainty while meeting the objectives of past experiments. An additional benefit of the design changes is reduced sensitivity of the fuel temperature to the evolving flux spectrum in HFIR, leading to more stable temperatures and enhanced utility of MiniFuel as a separate effects irradiation platform.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction

Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.

47 OTHER INSTRUMENTATION↗

Modified soldering iron speeds cutting of synthetic materials

Modified soldering iron cuts large lots of synthetic materials economically without leaving frayed or jagged edges. The soldering iron is modified by machining an axial slot in its heating element tip and mounting a cutting disk in it. An alternate design has an axially threaded bore in the tip to permit the use of various shapes of cutting blades.

Schafer, W. G., Jr.↗

New tungsten alloy has high strength at elevated temperatures

Tungsten-hafnium-carbon alloy has tensile strengths of 88,200 psi at 3000 deg F and 62,500 psi at 3500 deg F. Possible industrial applications for this alloy would include electrical components such as switches and spark plugs, die materials for die casting steels, and heating elements.

Source record↗

Resistance heating releases structural adhesive

Composite adhesive package bonds components together for testing and enables separation when testing is completed. The composite of adhesives, insulation and a heating element separate easily when an electrical current is applied.

Glemser, N. N.↗

Technology Development of a Biowaste Resistojet, Volume 2

The thruster development effort of the biowaste resistojet program is reported. Under this program, several variations of the concentric tube resistojet were built and tested. Because of the corrosive nature of the biowaste gases available for propellants, thruster effort was concentrated on the use of noble metals (platinum and its alloys) for the critical center tube heating element. This tube must operate at high temperatures. Initially the biowaste gases were projected to be CO2, CH4, H2O or H2 with only very small amounts of O2 or N2. However, during 1971, results from experimental life support tests indicated that the oxygen content would probably be in the range from 0.5 to 1.0%. To achieve the desired high specific impulses, metal temperatures as high as 1700 K (3060 R) were considered desirable goals. The first thruster, designated Mark 1, employed the alloy platinum-rhodium for the center tube. Although this material was oxidation resistant and had high strength relative to pure platinum, experimental materials tests showed that this alloy suffered from carbonyl reactions when tested on pure CO2. These reactions resulted in a depletion of rhodium and significantly weakened the tubes. The next series of thrusters were designated Mark 2 and employed platinum-iridium for the center tubes.

Phillips, D. G.↗