Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hemodynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The Automated Primate Research Laboratory (APRL)

A description is given of a self-contained automated primate research laboratory to study the effects of weightlessness on subhuman primates. Physiological parameters such as hemodynamics, respiration, blood constituents, waste, and diet and nutrition are analyzed for abnormalities in the simulated space environment. The Southeast Asian pig-tailed monkey (Macaca nemistrina) was selected for the experiments owing to its relative intelligence and learning capacity. The objective of the program is to demonstrate the feasibility of a man-tended primate space flight experiment.

Pace, N.↗

Observation of arterial blood pressure of the primate

The developments are reported in physiological instrumentation, surgical procedures, measurement and data analysis techniques, and the definition of flight experiments to determine the effects of prolonged weightlessness on the cardiovascular system of subhuman primates. The development of an implantable telemetric data acquisition system is discussed along with cardiovascular research applications in renal hemodynamics. It is concluded that the implant technique permits a valid interpretation, free of emotional response, for the manipulated variable on physiological functions. It also allows a better definition of normal physiological baseline conditions.

Meehan, J. P.↗

Fluid dynamic aspects of cardiovascular behavior during low-frequency whole-body vibration

The behavior of the cardiovascular system during low frequency whole-body vibration, such as encountered by astronauts during launch and reentry, is examined from a fluid mechanical viewpoint. The vibration characteristics of typical manned spacecraft and other vibration environments are discussed, and existing results from in vivo studies of the hemodynamic aspects of this problem are reviewed. Recent theoretical solutions to related fluid mechanical problems are then used in the interpretation of these results and in discussing areas of future work. The results are included of studies of the effects of vibration on the work done by the heart and on pulsatile flow in blood vessels. It is shown that important changes in pulse velocity, the instantaneous velocity profile, mass flow rate, and wall shear stress may occur in a pulsatile flow due to the presence of vibration. The significance of this in terms of changes in peripheral vascular resistance and possible damage to the endothelium of blood vessels is discussed.

Nerem, R. M.↗

An implantable blood pressure and flow transmitter.

A miniature totally implantable FM/FM telemetry system has been developed to simultaneously measure blood pressure and blood flow, thus providing an appreciation of the hemodynamics of the circulation to the entire body or to a particular organ. Developed for work with animal subjects, the telemetry system's transmission time is controlled by an RF signal that permits an operating life of several months. Pressure is detected by a miniature intravascular transducer and flow is detected by an extravascular interferometric ultrasonic technique. Both pressure and flow are calibrated prior to implanting. The pressure calibration can be checked after the implanting by cannulation; flow calibration can be verified only at the end of the experiment by determining the voltage output from the implanted sensing system as a function of several measured flow rates. The utility of this device has been established by its use in investigating canine renal circulation during exercise, emotional encounters, administration of drugs, and application of accelerative forces.

Rader, R. D.↗

Influence of flow and pressure on wave propagation in the canine aorta.

Data on wave speed acquired from 20 anesthetized dogs showed that the thoracic aorta was essentially nondispersive for small artificially generated pressure waves traveling in the downstream or the upstream direction and having frequencies between 40 and 120 Hz. The amplitude of these waves decayed exponentially with the distance traveled. Theoretical studies are cited which have shown that changes in wave speed due to variations in pressure and flow produce marked nonlinear effects in hemodynamics.

Histand, M. B.↗

Effects of posture on exercise performance - Measurement by systolic time intervals.

Because posture significantly influences cardiac performance, the effects of moderate supine and upright ergometer exercise were compared on the basis of proportional (+37%) rate increments over resting control. Supine exercise produced significant decreases in left ventricular ejection time (LVET), pre-ejection period (PEP), and isovolumic contraction time (IVCT). Ejection time index (ETI) and corrected ejection time (LVETc) did not change significantly. Upright exercise produced greater decreases in PEP and LVET, but despite the rate increase there was no change in LVET, which resulted in sharp increases in ETI and LVETc. The discordant directional effects on LVET and its rate-correcting indices between the two postures were consistent with hemodynamic studies demonstrating lack of stroke volume change during supine exercise and increased stroke volume over control during light to moderate upright exercise.

Spodick, D. H.↗

View of human problems to be addressed for long-duration space flights

Review of the principal physiological changes seen in space flight, and discussion of various countermeasures which may prove to be useful in combating these changes in long-term space flight. A number of transient changes seen in Apollo astronauts following space flights are discussed, including cardiovascular and hemodynamic responses to weightlessness, musculoskeletal changes, changes in fluid and electrolyte balance, microbiological changes, and vestibular effects. A number of countermeasures to the effects of space flight on man are cited, including exercise, medication, diet, lower-body negative pressure, gradient positive pressure, venous occlusion cuffs, and others. A detailed review is then made of a number of psychological factors bearing on the ability of the human organism to withstand the rigors of long space flights.

Berry, C. A.↗

Effects of positive acceleration /+Gz/ on renal function and plasma renin in normal man

The effects of positive radial centrifugation (+Gz) on plasma resin activity (PRA) and renal function were assessed in 15 normal male subjects under carefully controlled conditions of Na, K, and water intake. Twenty minutes of +2.0 Gz resulted in significant decreases in the mean rate of sodium excretion and creatine clearance and in a doubling of PRA in seven sodium-depleted subjects (10 meq Na intake). In eight sodium-replete subjects (200 mq Na intake), 30 min of +2.0 Gz was also associated with a decrease in the mean rate of sodium excretion. As a consequence of a concurrent decrease in creatine clearance, the fractional excretion of sodium during centrifugation did not differ from control, suggesting that the changes in Na excretion were mediated primarily by renal hemodynamic factors, although enhanced renal tubular sodium reabsorption may also have played a role.

Epstein, M.↗

Renal parameter estimates in unrestrained dogs

A mathematical formulation has been developed to describe the hemodynamic parameters of a conceptualized kidney model. The model was developed by considering regional pressure drops and regional storage capacities within the renal vasculature. Estimation of renal artery compliance, pre- and postglomerular resistance, and glomerular filtration pressure is feasible by considering mean levels and time derivatives of abdominal aortic pressure and renal artery flow. Changes in the smooth muscle tone of the renal vessels induced by exogenous angiotensin amide, acetylcholine, and by the anaesthetic agent halothane were estimated by use of the model. By employing totally implanted telemetry, the technique was applied on unrestrained dogs to measure renal resistive and compliant parameters while the dogs were being subjected to obedience training, to avoidance reaction, and to unrestrained caging.

Rader, R. D.↗

Interdisciplinary studies on the development of nuclear-fueled circulatory support systems: Collaboration of industry and academe

The purpose of this report is to acquaint the Houston community with specific areas of available technology, both public and private, to demonstrate to industry how this technology may be acquired and put to use to provide new and useful services for man. Much of the technology utilized in the development of nuclear-fueled circulatory support systems in our laboratories has evolved from industry, NASA, and AEC; our projects involve radiation biology, thermodynamics, energy transfers, hemodynamics, hematology, pathology, and surgery.

Norman, J. C.↗

Respiration, respiratory metabolism and energy consumption under weightless conditions

Changes in the physiological indices of respiration, respiratory metabolism and energy consumption in spacecrews under weightlessness conditions manifest themselves in increased metabolic rates, higher pulmonary ventilation volume, oxygen consumption and carbon dioxide elimination, energy consumption levels in proportion to reduction in neuroemotional and psychic stress, adaptation to weightlessness and work-rest cycles, and finally in a relative stabilization of metabolic processes due to hemodynamic shifts.

Kasyan, I. I.↗

Physiological responses to environmental factors related to space flight

Physiological procedures and instrumentation developed for the measurement of hemodynamic and metabolic parameters during prolonged periods of weightlessness are described along with the physiological response of monkeys to weightlessness. Specific areas examined include: cardiovascular studies; thyroid function; blood oxygen transport; growth and reproduction; excreta analysis for metabolic balance studies; and electrophoretic separation of creatine phosphokinase isoenzymes in human blood.

Pace, N.↗

Fluid dynamics of heart assist device

Certain hemodynamic phenomena that arise in connection with the use of artificial blood pumping devices are reviewed. Among these are: (1) Flows produced by collapsing bulbs; (2) the impedance presented by the aorta; (3) limiting velocities and instability of flow in elastic vessels; (4) effectiveness of valveless arterio-arterial pumps, and (5) wave reflection phenomena and instabilities associated with the intra-aortic balloon pump.

Jones, R. T.↗

Exercise cardiac output following Skylab missions - The second manned Skylab mission

Cardiac output was measured during preflight and postflight exercise-stress tests on the Skylab astronauts. In the postflight tests immediately following the 28-, 59-, and 84-d earth orbital missions, the astronauts exhibited an approximate 30% decrease in cardiac output coupled with an approximate 50% decrease in cardiac stroke volume during exercise. These changes were accompanied by elevated heart rates and significant increases in total systemic peripheral vascular resistance. Mean arterial pressure was unchanged. All parameters returned to normal preflight values within 30 d of the end of the orbital period. Duration of the zero-G exposure did not appear to influence either the magnitude of the hemodynamic changes or the time-course of their return to normal. These results are discussed in relation to other cardiovascular findings and possible mechanisms responsible for the observations are outlined.

Buderer, M. C.↗

Vectorcardiographic results from Skylab medical experiment M092: Lower body negative pressure

Electrocardiographic interval changes suggesting effects of increased vagal tone were observed early in some Gemini crewmembers. Preflight versus postflight amplitude differences appeared in electrocardiograms of several of the early Apollo crewmembers. In preflight and postflight crew evaluations of the last three Apollo flights, quantitative postflight vectorcardiographic changes were for the first time determined in American space crews. Changes not considered related to heart rate were mainly those of increased P and QRS vector magnitudes and orientation shifts. But since most of these postflight findings resembled those observed with the orthostatic stress of lower body negative pressure, it was inferred then that upon their return from space, these Apollo astronauts exhibited exaggerated responses to orthostasis in the vectorcardiogram as well as in measures of cardiovascular hemodynamics.

Hoffler, G. W.↗

Computerized X-ray reconstruction tomography in stereometric analysis of cardiovascular dynamics

A computerized technique is proposed for obtaining cross-sectional images of the dynamic spatial distribution of X-ray attenuation covering the entire anatomic extent of the thorax and its contents in living dogs with a resolution of 1 mm and at time intervals of 1/60 sec. Use is made of an X-ray imaging chain which is a new high-performance video-fluoroscopic system, unique in its design and construction and called SSDSR for single source dynamic spatial reconstructor. This dynamic spatial reconstruction system is shown to provide the temporally and spatially coherent multiple cross sections required to obtain the full three-dimensional anatomic and simultaneous hemodynamic information necessary for detailed quantitative analyses of regional cardiopulmonary and vascular functions in both basic investigations of animals and clinical diagnostic applications to patients. Numerous photographs supplement the text.

Robb, R. A.↗

Left ventricular function during lower body negative pressure

The response of the human left ventricle to lower body negative pressure (LBNP) and the relation between left ventricular function and hemodynamic response were investigated. Ventricular function curves relating stroke volume to end-diastolic volume were obtained in 12 normal men. Volume data were derived from echocardiographic measurements of left ventricular end-systolic and end-diastolic diameters at rest and during lower body negative pressure (LBNP) at minus 40 mm Hg. End-diastolic volume decreased by 19% and stroke volume by 22%. There were no significant changes in heart rate, arterial blood pressure, or end-systolic volume. Thus, moderate levels of LBNP significantly reduce preload and stroke volume without affecting contractile state. The absence of significant changes in heart rate and arterial blood pressure in the presence of a significant reduction in stroke volume is consistent with an increase in systemic peripheral resistance mediated by low-pressure baroreceptors.

Ahmad, M.↗