Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Computing, Performance, Power, Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Modeling a Gas-Cooled Microreactor Balance of Plant for the Virtual Test Bed

High Temperature Gas-cooled Reactors (HTGRs) are one of the technology considered for microreactor designs because of their high performance and technological maturity. Several designs are being developed. These microreactor cores are connected to power conversion system (PCS) through a heat exchanger. For transient analysis, the feedback of the PCS or of the primary loop can be important, therefore, it is necessary to develop robust models for the balance of plant that can be coupled to a core model. In this work, a balance of plant model using the MOOSE Thermal Hydraulics module (THM) is presented and demonstrated for startup and load-follow transients. This model can be seamlessly coupled with any MOOSE-based multi-physics core model using the MOOSE multi-app approach.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Test of 29 mm and 12 mm Targets

NorthStar medical isotopes are planning to produce important medical radioisotope molybdenum-99 (Mo-99) through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, multiple thin disks of enriched molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, we intend to use as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target),which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium atmosphere inside the target from the vacuum in the beamline so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flow from one side, making the window design challenging. To validate calculation models, the team performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF). This report describes additional tests for two target designs: a full-scale target 29 millimeters in diameter and a scaled-down version, 12 millimeters in diameter. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.

07 ISOTOPE AND RADIATION SOURCES↗

Computational Modeling of Graphite Degradation due to Molten Salt Infiltration and Wear

Molten-salt reactors (MSRs) represent a promising next-generation reactor design, with graphite serving as a moderator and/or reflector in several designs. However, due to limited experimental data and operational experience, a technical understanding of the structural integrity of graphite in molten salt environments remains incomplete. This report presents a modeling-based evaluation of graphite degradation in MSR environments, focusing on the effects of salt infiltration in fuel salt-based designs and surface wear in pebble bed reactor designs. The objective of this study is to enhance understanding of the structural integrity challenges posed by these degradation mechanisms and to provide a framework for assessing graphite behavior in MSRs. The first part of the report investigates the phenomenon of molten salt infiltration into graphite. This infiltration occurs when molten salt permeates the interconnected pore structure of the graphite moderator, driven by factors such as pressure differentials and the physical properties of both the salt and graphite. The infiltration process is influenced by characteristics of the pore structure, viscosity of the molten salt, and the interfacial energies between the graphite, salt, and the atmosphere within the graphite pore. Utilizing a coupled multiphysics modeling approach with Grizzly software, the study evaluates the stress induced by internal heat sources due to infiltration, which can lead to structural concerns. This evaluation is crucial for understanding how infiltration affects the mechanical integrity of graphite components in MSRs. The study considers the Molten-Salt Reactor Experiment (MSRE) graphite stringer geometry due to the availability of relevant data. Through detailed finite element analysis, the study examines stress distributions at varying infiltration percentages, revealing that stress levels increase with higher amounts of infiltration. Rare-event simulations, using the parallel subset simulation (PSS) framework, further quantify the failure probabilities under input uncertainties, with a user-specified failure metric. The PSS framework also identifies critical input parameters that significantly affect the stress values, including infiltration amount, thermal conductivity, and power density. Additionally, considering realistic reactor scenarios, the analysis was performed to account for the combined effects of radiation and infiltration, and modeling strategies on how to analyze new reactor designs or new graphite grades are discussed. The second part of the report focuses on wear mechanisms in pebble bed-based MSRs. As graphite fuel pebbles interact with the graphite reflector block, wear can result in material loss and the formation of surface defects, which may act as stress concentrators. A similar multiphysics modeling framework is employed to assess the impact of wear on the structural integrity of graphite components. This study considers a generic fluoride-cooled high-temperature reactor (gFHR) design due to the availability of comprehensive data. Worst-case scenario dimensions of the reflector blocks were analyzed under thermal and radiation conditions. Subsequently, wear in the form of idealized pits and grooves is modeled on the inner surface of the graphite block, with the maximum stress from previous simulations. The simulations show that groove-type defects are more detrimental than pits, leading to higher stress concentrations. Considering worst-case simulation scenarios and experimental wear rates, it was determined that the formation of a surface defect critical enough to affect the stress may not be possible in a gFHR design. Overall, the findings of this research contribute to the development of robust modeling tools for predicting graphite behavior under various operational conditions in MSRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Superconducting Qubits above 20 GHz Operating over 200 mK

Current state-of-the-art superconducting microwave qubits are cooled to extremely low temperatures to avoid sources of decoherence. Higher qubit operating temperatures would significantly increase the cooling power available, which is desirable for scaling up the number of qubits in quantum computing architectures and integrating qubits in experiments requiring increased heat dissipation. To operate superconducting qubits at higher temperatures, it is necessary to address both quasiparticle decoherence (which becomes significant for aluminum junctions above 160 mK) and dephasing from thermal microwave photons (which are problematic above 50 mK). Using low-loss niobium-trilayer junctions, which have reduced sensitivity to quasiparticles due to the higher superconducting transition temperature of niobium, we fabricate transmons with higher frequencies than previously studied, up to 24 GHz. We measure decoherence and dephasing times of about 1 μs, corresponding to average qubit quality factors of approximately 10 5 , and find that decoherence is unaffected by quasiparticles up to 1 K. Without relaxation from quasiparticles, we are able to explore dephasing from purely thermal sources, finding that our qubits can operate up to approximately 250 mK while maintaining similar performance. The thermal resilience of these qubits creates new options for scaling up quantum processors, enables hybrid quantum experiments with high heat-dissipation budgets, and introduces a material platform for even-higher-frequency qubits.

Josephson junctions↗

Comparison of subchannel and averaged channel thermal-hydraulic descriptions on coupled pin-by-pin neutronic calculations

Best-estimate transient analysis of Light Water Reactors (LWRs) requires high accuracy code systems solving neutronics (NK), thermal-hydraulics (TH) and thermal-mechanics to model the core behavior. For long time, nodal diffusion methods for solution of the transport equation using assembly size computational meshes have been applied neglecting the details within the fuel assembly, or using 'pin power reconstruction' techniques to predict those details. Moreover, the multiphysics analysis has been commonly performed coupling those neutronic diffusion methods to thermal-hydraulic system codes using a nodalization of several fuel assemblies per computational node without taking into account the effects that this type of averaging can have on the results obtained. This paper presents the work accomplished with the coupled system COBAYA4/CTF for a preliminary analysis of the effect of the different accuracy levels in the NK and TH domain. COBAYA4 is a neutronic code able to solve the diffusion equation at two resolution levels, nodal and pin by pin (PbP). CTF is a thermo-hydraulic code able to solve the coolant conservation equations also at two levels, channel (fuel assembly averaged solution) and sub-channel (real cooling channel) level. The coupled system COBAYA4/CTF is used through SALOME platform, i.e. SALOME is the software able to map conveniently the NK and TH meshes. This coupling allows combining different resolution levels for NK and TH problems. Therefore, the study of the effect of using different resolutions for the NK and TH nodalizations has been performed applying the system to a fuel assembly with selected boundary conditions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Study on Neutronics Calculation Method of SCWR with Annular Fuel Assembly

Supercritical Water-Cooled Reactor (SCWR) is one of Gen-IV reactor systems for its advantages over LWRs, such as high thermal efficiency, simplified reactor system and economics. Annular fuel was proposed by MIT to supplant conventional solid fuel and improve power density in LWRs. Annular fuel is cooled from both inside and outside of the fuel. Thus a lower fuel temperature and cladding surface temperature can be achieved with higher power density. SCWRs will benefit from this advantage because high cladding temperature (usually over 650 degree C) is one challenge of SCWRs. Using annular fuel in SCWRs is very promising. This is also because the inner hole of the annual fuel can provide extra neutron moderation. Supercritical water density is too low to provide enough moderation. Different analysis codes have been developed all over the world to carry out SCWR pre-conceptual core design. Yamaji et al. developed SRAC/ASMBURN/COREBN to study Japan version of SCWR. Monti et al. used ERANOS to analyze HPLWR (High Performance Light Water Reactor). WIMS-D4/CITATION was also used to calculate HPLWR by Tashakor et al.. These codes employ a two-step method used in PWRs calculation. Lattice/Assembly calculation is carried out as the first step. In the second step, few group constant of different fuel assembly types is then used in core calculation. MCNP had also been used to study SCWR by Watta et al.. Due to large computation time cost, it's used mostly to analyze fuel assembly or core performance rather than pre-conceptual design, in which much optimization is needed. In this research, a neutronics calculation code for SCWR is developed using two-step method. This code is verified by comparing with Monte-Carlo code. Fuel assembly homogenization method is studied to improve the code accuracy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fluoride-Cooled High-Temperature Pebble-Bed Reactor Reference Plant Model

In this report we present work performed in Fiscal Year 2022 that demonstrates the modeling and simulation of a fully coupled neutronics thermal hydraulics reference plant model for a fluoride-cooled high-temperature pebble-bed reactor. The multiphysics model is developed on the Nuclear Regulatory Commission’s Comprehensive Reactor Analysis Bundle (BlueCRAB) available on the Idaho National Laboratory’s high-performance computer, which natively and seamlessly couples Griffin, Pronghorn, and the BISON Multiphysics Object-Oriented Simulation Environment based applications. Griffin provides reactor physics capabilities, including depletion to the equilibrium core, k-eigenvalue, adjoint, and transient. The unique direct equilibrium core capability in Griffin is based on a streamline methodology to spatially deplete the pebbles into burnup groups. Pronghorn solves the porous medium equations for the fluid regions and conduction in the solid regions and incorporates a fluidic diode model to simulate the transition from forced to natural convection during accident scenarios. MOOSE modules solves thermal conduction problems for the pebbles and tristructural isotropic in the pebble-bed core, thus providing the fuel and moderator spatial fields for each pebble burnup group. The neutronics feedback relies primarily on fuel, moderator, and reflector temperatures as as well as the FLiBe salt density. Here, we present results for the uncoupled equilibrium core and perform comparisons to equivalent Monte Carlo models. The power distributions and kinetic parameters obtained with Griffin are consistent with those computed with Griffin. We demonstrate a noticeable improvement with the use of discrete ordinates method (SN) transport. The coupled steady-state equilibrium core provides the initial condition for two time-dependent problems: a control rod withdrawal event and an unprotected loss of flow event. In both cases, the reactor design is self-stabilizing and the solutions are consistent with the expected physics. Although this model is prototypical regarding BlueCRAB’s capabilities, its results are consistent with published work by Kairos Power and other research entities. Significant improvements to the model are planned in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat deposition analysis for the High Flux Isotope Reactor’s HEU and LEU core models

The High Flux Isotope Reactor at Oak Ridge National Laboratory is an 85 MW th pressurized light-water-cooled and -moderated flux-trap type research reactor. The reactor is used to conduct numerous experiments, advancing various scientific and engineering disciplines. As part of an ongoing program sponsored by the US Department of Energy National Nuclear Security Administration Office of Material Management and Minimization, studies are being performed to assess the feasibility of converting the reactor’s highly enriched uranium fuel to low-enriched uranium fuel. To support this conversion project, reference models with representative experiment target loading and explicit fuel plate representation were developed and benchmarked for both fuels to (1) allow for consistent comparison between designs for both fuel types and (2) assess the potential impact of low-enriched uranium conversion. These high-fidelity models were used to conduct heat deposition analyses at the beginning and end of the reactor cycle and are presented herein. This article (1) discusses the High Flux Isotope Reactor models developed to facilitate detailed heat deposition analyses of the reactor’s highly enriched and low-enriched uranium cores, (2) examines the computational approach for performing heat deposition analysis, which includes a discussion on the methodology for calculating the amount of energy released per fission, heating rates, power and volumetric heating rates, and (3) provides results calculated throughout various regions of the highly enriched and low-enriched uranium core at the beginning and end of the reactor cycle. These are the first detailed high-fidelity heat deposition analyses for the High Flux Isotope Reactor’s highly enriched and low-enriched core models with explicit fuel plate representation. Lastly, these analyses are used to compare heat distributions obtained for both fuel designs at the beginning and end of the reactor cycle, and they are essential for enabling comprehensive thermal hydraulics and safety analyses that require detailed estimates of the heat source within all of the reactor’s fuel element regions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity Analysis of Passive Heat Removal Capability of FHR Based on Efficient Surrogate Model and GenFlow

Code Scaling, Applicability and Uncertainty Evaluation Methodology (CSAU) is used for quantifying reactor safety margins and works as an alternative method for licensing nuclear power plant. In the framework of CSAU, sensitivity and uncertainty analysis (SA and UA) should be performed. However, for large-scale complicated thermal hydraulics analysis simulated by code (e.g. RELAP5, CFD and subchannel analysis, the sensitivity and uncertainty analysis is really time-consuming. Furthermore, sometimes it is not feasible to perform SA and UA. Specifically, the computation time for Monte Carlo sampling or advanced LHS sampling can be neglected, but the computation time for thermal hydraulics code makes up main part of time during SA and UA process. In order to accelerate the speed of SA and UA, thermal hydraulics code can be improved based on advanced mathematic algorithm or using parallel method. However, the development for new mathematic method needs long time and strict verification and validation process is needed for a new code, which usually takes a couple of years or even longer time to have an approved code that can be used in nuclear industry. An alternative way to improve the speed of SA and UA is using surrogate model. The surrogate model is derived from the input as well as output data of the original code, assuming the code as a black box. The most common method is using response surface method (RSM) as a surrogate for the code, the input parameters are then sampled from their assumed distribution and the corresponding value of the response surface function is calculated. However, a couple of input parameters need hundreds or even thousands of original code calculations. The large number of runs is an obvious disadvantage of this method. Besides, the second disadvantage is an appropriate response surface function must be selected (e.g. quadratic, cubic, quartic, with or without cross product terms, or using a non-polynomial form) to avoid the overfit and underfit problem. This process is time consuming and expensive. Polynomial chaos expansion method is a reasonably fast and attractive alternative, stochastic model. The chaos expansion provides an efficient high-order method of including non-linear effects in stochastic analysis. Usually, the information about the model parameters and their probability distribution is limited and the dependence between them is not known. However, if arbitrary polynomial chaos is used, instead of assuming probability distribution for input parameters which may introduces additional subjectivity into the analysis, the available information can directly and most purely be used in stochastic analysis based on arbitrary data distribution. Thus, it is not necessary to know the exact probability density functions to perform SA and UA based on arbitrary polynomial chaos (aPC). The aPC has been applied for uncertainty quantification in many fields (e.g. in solid mechanics, fluid flows, thermal sciences), and become widely used in nuclear industry recently. Mk1 PB-FHR is a small modular fluoride-salt-cooled, high-temperature reactors (FHRs) that is a concept design by University of California, Berkeley (UCB). It has inherently safe features like natural-circulation-driven systems (e.g. direct reactor auxiliary cooling system (DRACS)) to passively remove decay heat from the reactor core during design basis and beyond design. It is necessary to perform SA and UA, since the licensing process of this new kind of reactor is under way and there are many design parameters that have not been fixed. Current nuclear commercial codes, such as RELAP5, have mainly been developed for light water reactors, which require the use of comprehensive two-phase flow models. This capability is not required to simulate single-phase flow phenomena in FHRs, whose baseline coolant, flibe, remains liquid up to 1430 deg. C at atmospheric pressure. The FHR advanced natural circulation analysis (FANCY) code has been developed specifically for FHR technology modeling and validation work has been performed by using CIET data in UCB. The code has been renamed General Flow (GenFlow) because it has been further developed to have the capability to model complicated pipework system based on object-oriented concept for user friendly purpose. Besides, it can be used to simulate both the force circulation as well as natural circulation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High–Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next–generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds–averaged Navier–Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

97 MATHEMATICS AND COMPUTING↗

Use of Data Denial Experiments to Evaluate ESA Forecast Sensitivity Patterns

The overall goal of this multi-phased research project known as WindSENSE is to develop an observation system deployment strategy that would improve wind power generation forecasts. The objective of the deployment strategy is to produce the maximum benefit for 1- to 6-hour ahead forecasts of wind speed at hub-height ({approx}80 m). In this phase of the project the focus is on the Mid-Columbia Basin region which encompasses the Bonneville Power Administration (BPA) wind generation area shown in Figure 1 that includes Klondike, Stateline, and Hopkins Ridge wind plants. The Ensemble Sensitivity Analysis (ESA) approach uses data generated by a set (ensemble) of perturbed numerical weather prediction (NWP) simulations for a sample time period to statistically diagnose the sensitivity of a specified forecast variable (metric) for a target location to parameters at other locations and prior times referred to as the initial condition (IC) or state variables. The ESA approach was tested on the large-scale atmospheric prediction problem by Ancell and Hakim 2007 and Torn and Hakim 2008. ESA was adapted and applied at the mesoscale by Zack et al. (2010a, b, and c) to the Tehachapi Pass, CA (warm and cools seasons) and Mid-Colombia Basin (warm season only) wind generation regions. In order to apply the ESA approach at the resolution needed at the mesoscale, Zack et al. (2010a, b, and c) developed the Multiple Observation Optimization Algorithm (MOOA). MOOA uses a multivariate regression on a few select IC parameters at one location to determine the incremental improvement of measuring multiple variables (representative of the IC parameters) at various locations. MOOA also determines how much information from each IC parameter contributes to the change in the metric variable at the target location. The Zack et al. studies (2010a, b, and c), demonstrated that forecast sensitivity can be characterized by well-defined, localized patterns for a number of IC variables such as 80-m wind speed and vertical temperature difference. Ideally, the data assimilation scheme used in the experiments would have been based upon an ensemble Kalman filter (EnKF) that was similar to the ESA method used to diagnose the Mid-Colombia Basin sensitivity patterns in the previous studies. However, the use of an EnKF system at high resolution is impractical because of the very high computational cost. Thus, it was decided to use the three-dimensional variational analysis data assimilation that is less computationally intensive and more economically practical for generating operational forecasts. There are two tasks in the current project effort designed to validate the ESA observational system deployment approach in order to move closer to the overall goal: (1) Perform an Observing System Experiment (OSE) using a data denial approach which is the focus of this task and report; and (2) Conduct a set of Observing System Simulation Experiments (OSSE) for the Mid-Colombia basin region. The results of this task are presented in a separate report. The objective of the OSE task involves validating the ESA-MOOA results from the previous sensitivity studies for the Mid-Columbia Basin by testing the impact of existing meteorological tower measurements on the 0- to 6-hour ahead 80-m wind forecasts at the target locations. The testing of the ESA-MOOA method used a combination of data assimilation techniques and data denial experiments to accomplish the task objective.

17 WIND ENERGY↗

Selected results from full-core hydrogen redistribution asymptotic analysis in YH-moderated heat-pipe cooled microreactor

Yttrium hydride is the main candidate for moderation of high temperature nuclear microreactors . This is due to its high thermal stability and relatively high hydrogen retention at temperatures exceeding 870 C. One of the main issues associated with the use of yttrium hydride is that, when exposed to temperature, stress, or concentration gradients, the hydrogen contained in the metallic matrix tends to redistribute and leak from the moderating elements, potentially leading to reactivity losses and power swings. This paper is focused on presenting selected results from the asymptotic hydrogen redistribution analysis performed on the Simplified Microreactor Benchmark Assessment (SiMBA) problem, a microreactor core conceptual design developed at INL. The analysis is based on full core analysis, relies uniquely on Bison to perform hydrogen redistribution calculations, and discusses the physical causes of the reactivity feedback. It was found that the feedback is negative, but it is one order of magnitude lower than the one found for the empire reactor unit-cell. This is due to the lower axial temperature gradient together with the effect of the reflector.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MODELING THE AMBIENT CONDITION EFFECTS OF AN AIR-COOLED NATURAL CIRCULATION SYSTEM

The Reactor Cavity Cooling System (RCCS) is a passive safety concept under consideration for the overall safety strategy of advanced reactors such as the High Temperature Gas-Cooled Reactor (HTGR). One such variant, air-cooled RCCS, uses natural convection to drive the flow of air from outside the reactor building to remove decay heat during normal operation and accident scenarios. The Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne National Laboratory (“Argonne”) is a half-scale model of the primary features of one conceptual air-cooled RCCS design. The facility was constructed to carry out highly instrumented experiments to study the performance of the RCCS concept for reactor decay heat removal that relies on natural convection cooling. Parallel modeling and simulation efforts were performed to support the design, operation, and analysis of the natural convection system. Throughout the testing program, strong influences of ambient conditions were observed in the experimental data when baseline tests were repeated under the same test procedures. Thus, significant analysis efforts were devoted to gaining a better understanding of these influences and the subsequent response of the NSTF to ambient conditions. It was determined that air humidity had negligible impacts on NSTF system performance and therefore did not warrant consideration in the models. However, temperature differences between the building exterior and interior air, along with the outside wind speed, were shown to be dominant factors. Combining the stack and wind effects together, an empirical model was developed based on theoretical considerations and using experimental data to correlate zero-power system flow rates with ambient meteorological conditions. Some coefficients in the model were obtained based on best fitting the experimental data. The predictive capability of the empirical model was demonstrated by applying it to the new set of experimental data. The empirical model was also implemented in the computational models of the NSTF using both RELAP5-3D and STARCCM+ codes. Accounting for the effects of ambient conditions, simulations from both codes predicted the natural circulation flow rates very well.

Hu, Rui↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved Prediction of the Temperature Feedback in TRISO-Fueled Reactors

The Doppler feedback mechanism is a major contributor to the passive safety of gas-cooled, graphite-moderated high temperature reactors that use fuel based on Tristructural-Isotropic coated particles. It follows that the correct prediction of the magnitude and time-dependence of this feedback effect is essential to the conduct of safety analyses for these reactors. We present a fuel conduction model for obtaining better estimates of the temperature feedback during moderate and fast transients. The fuel model has been incorporated in the CYNOD-THERMIX-KONVEK suite of coupled codes as a single TRISO particle within each calculation cell. The heat generation rate is scaled down from the neutronic solution and a Dirichlet boundary condition is imposed as the bulk graphite temperature from the thermal-hydraulic solution. This simplified approach yields similar results to those obtained with more complex methods, requiring multi-TRISO calculations within one control volume, but with much less computational effort. An analysis of the hypothetical total control ejection in the PBMR-400 design verifies the performance of the code during fast transients. In addition, the analysis of the earthquake-initiated event in the PBMR-400 design verifies the performance of the code during slow transients. These events clearly depict the improvement in the predictions of the fuel temperature, and consequently, of the power escalations. In addition, a brief study of the potential effects of particle layer de-bonding on the transient behavior of high temperature reactors is included. Although the formation of a gap occurs under special conditions its consequences on the dynamic behavior of the reactor should be analyzed. The presence of a gap in the fuel can cause some unusual reactor behavior during fast transients, but still the reactor shuts down due to the strong feedback effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HIGH-FIDELITY SIMULATION-DRIVEN MODEL DEVELOPMENT FOR COARSE-GRAINED COMPUTATIONAL FLUID DYNAMICS

Nuclear reactor safety analysis requires identifying various credible accident scenarios and determining their consequences. For a full-scale nuclear power plant system behavior, it is impossible to obtain sufficient experimental data for a broad range of risk-significant accident scenarios. In single-phase flow convective problems, Direct Numerical Simulation (DNS) and Large Eddy Simulation (LES) can provide us with high fidelity results when physical data are unavailable. However, these methods are computationally expensive and cannot be afforded for simulation of long transient scenarios in nuclear accidents despite extraordinary advances in high performance scientific computing over the past decades. The major issue is the inability to make the transient computation parallel, thus making number of time steps required in high-fidelity methods unaffordable for long transients. In this work, we propose to apply a high fidelity simulation-driven approach to model sub-grid scale (SGS) effect in Coarse Grained Computational Fluid Dynamics CG-CFD. This approach aims to develop a statistical surrogate model instead of the deterministic SGS model. We chose to start with a turbulent natural convection case with volumetric heating in a horizontal fluid layer with a rigid, insulated lower boundary and isothermal (cold) upper boundary. This scenario of unstable stratification is relevant to turbulent natural convection in a molten corium pool during a severe nuclear reactor accident, as well as in containment mixing and passive cooling. The presented approach demonstrates how to create a correction for the CG-CFD solution by modifying the energy balance equation. A global correction for the temperature equation proves to achieve a significant improvement to the prediction of steady state temperature distribution through the fluid layer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY22 Status Report on the ART-GCR CMVB and CNWG International Collaborations

This work presents the numerical model for the high temperature test reactor (HTTR) loss of forced cooling (LOFC) experiment with the INL codes Griffin, BISON, and RELAP-7, based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Promising results were obtained, with the overall behavior of the reactor successfully captured. Changes in the heat transfer coupling, as compared to the fiscal year (FY)-21 model, enabled drastic improvement of the steady-state solution, both in terms of computational time and global energy discrepancies. The former was reduced by a factor of roughly 60, whereas the latter decreased from 11% to less than 2%. Furthermore, the discrepancy in the steady-state multiplication factor was improved from +2,300 and +2,900 pcm (for the 30 and 9 MW cases) to -700 and +1,200 pcm, respectively, and now falls well within the large measurement uncertainties stemming from graphite impurities. Validation of the Monte Carlo model used to generate cross sections was also performed against available measurements. Though significant, the discrepancies remain acceptable overall in light of the large uncertainty. Numerous improvements are still needed to better compare with the experiment involving the 9 MW case and to instill greater confidence in the model’s ability to accurately predict the 30 MW behavior. Specifically, the power levels predicted by the 9 MW transient simulation following re-criticality remain low, pointing to an underestimation of the passive cooling of the core. A key aspect of future work will be to better understand the flow pattern during the LOFC event, particularly to determine if natural or forced convection is occurring inside the reactor pressure vessel (RPV). More generally, additional validation data would be immensely useful for further enhancing the numerical model and better matching the experiments. In addition, a more sophisticated thermal-hydraulics model that simulates all the channels as a single system model should be considered to take into account the rest of the primary loop. Finally, even if the results are in better agreement with the experiments, sensitivity analysis and uncertainty quantification will be necessary to evaluate the model uncertainty.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗