Final Technical Report- Back-gate Field Emission-based Cathode RF Electron Gun

The objective was to complete the design of an electron gun which utilizes a radio frequency (RF) power source to apply a voltage to a field emission (FE) cathode, a so called cold cathode, in order to produce an electron beam. The concept of the RF electron gun was originally conceived at Argonne National Laboratory but never reduced to practice. The research allowed the completion of the design based upon the integration of the FE electron source. Compared to other electron guns, the RF gun is very compact, less than one third the size of other comparable guns, and produces a high energy (to several MeV), high quality, high power electron beam with a long focal length with high repetition rates. The resultant electron gun may be used in welding, materials processing, analytical equipment and waste treatment.

43 PARTICLE ACCELERATORS↗

Modeling the LLRF Control of a Multi-Cavity RF Station for Project-X

Fermilab’s High Intensity Neutrino Source (HINS), the 325 MHz low energy section of Project X consists of an RFQ, 18 copper cavities and a section of superconducting spoke resonator cavities, all driven by a single 2.5 MW klystron. Each cavity has a high power ferrite vector modulator which provides individual RF power control. This paper proposes a scheme that optimizes RF drive and vector modulator control. The different gradients, acceleration phase angles, unloaded Q’s and beam loading are taken into account to optimize the cavities detuning angles, forward power, and loaded Q’s. This scheme makes an efficient use of the klystron’s high bandwidth ability to modulate the forward power, hence minimizing the burden on the high power vector modulator during the RF pulse. The proposed method is explained in details, a parameter sensitivity analysis is performed and the impact on the total power consumption for the RF station is calculated.

Branlard, J.↗

Rugged Ceramic Window for RF Applications – Phase 1

High-current RF cavities that are needed for many accelerator applications are often limited by the power transmission capability of the pressure barriers (windows) that separate the cavity from the power source. Most efforts to improve RF window design have focused on alumina ceramic, the most popular historical choice, and have not taken advantage of new materials. Alternative window materials have been investigated using a novel Merit Factor comparison and likely candidates have been tested for the material properties which will enable construction in the self-matched window configuration. Window assemblies have also been modeled and fabricated using compressed window techniques which have proven to increase the power handling capability of waveguide windows. Candidate materials have been chosen to be used in fabricating a window for high power testing at Thomas Jefferson National Accelerator Facility.

43 PARTICLE ACCELERATORS↗

On the scaling of rf and dc self-bias voltages with pressure in electronegative capacitively coupled plasmas

Higher gas densities and lower diffusion losses at higher operating pressures typically lead to increased charged species densities (and hence flux) for a constant power deposition in capacitively coupled plasmas (CCP). As a result, one would expect that the bias radio-frequency (rf) voltage required to deposit a given power in a CCP reactor decreases with increasing operating pressure. These observations may not hold true in multiple frequency CCPs, commonly used for dielectric etching in microelectronics fabrication, due to nonlinear interactions between the rf sources. Wafer-based measurements of the rf and self-generated direct current (dc) bias voltages in a dual-frequency capacitively coupled electronegative plasma were made, which indicate that the rf and dc voltages vary nonmonotonically with pressure. These experimental results are presented in this paper and a computational plasma model is used to explain the experimental observations for varying 60 MHz and 13 MHz powers in the Ar/CF{sub 4}/CHF{sub 3} plasma over a pressure range of 25 to 400 mTorr. The authors found that while the ion density increases with pressure, the increase is most dominant near the electrode with the high frequency source (60 MHz). The rf and dc bias voltages are ultimately influenced by both charged species density magnitudes and spatial profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systematic cavity design approach for a multi-frequency gyrotron for DEMO and study of its RF behavior

High frequency (>230 GHz) megawatt-class gyrotrons are planned as RF sources for electron cyclotron resonance heating and current drive in DEMOnstration fusion power plants (DEMOs). In this paper, for the first time, a feasibility study of a 236 GHz DEMO gyrotron is presented by considering all relevant design goals and the possible technical limitations. A mode-selection procedure is proposed in order to satisfy the multi-frequency and frequency-step tunability requirements. An effective systematic design approach for the optimal design of a gradually tapered cavity is presented. The RF-behavior of the proposed cavity is verified rigorously, supporting 920 kW of stable output power with an interaction efficiency of 36% including the considerations of realistic beam parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrating a Microwave Radiometer into Radar Hardware for Simultaneous Data Collection Between the Instruments

The conventional method for integrating a radiometer into radar hardware is to share the RF front end between the instruments, and to have separate IF receivers that take data at separate times. Alternatively, the radar and radiometer could share the antenna through the use of a diplexer, but have completely independent receivers. This novel method shares the radar's RF electronics and digital receiver with the radiometer, while allowing for simultaneous operation of the radar and radiometer. Radars and radiometers, while often having near-identical RF receivers, generally have substantially different IF and baseband receivers. Operation of the two instruments simultaneously is difficult, since airborne radars will pulse at a rate of hundreds of microseconds. Radiometer integration time is typically 10s or 100s of milliseconds. The bandwidth of radar may be 1 to 25 MHz, while a radiometer will have an RF bandwidth of up to a GHz. As such, the conventional method of integrating radar and radiometer hardware is to share the highfrequency RF receiver, but to have separate IF subsystems and digitizers. To avoid corruption of the radiometer data, the radar is turned off during the radiometer dwell time. This method utilizes a modern radar digital receiver to allow simultaneous operation of a radiometer and radar with a shared RF front end and digital receiver. The radiometer signal is coupled out after the first down-conversion stage. From there, the radar transmit frequencies are heavily filtered, and the bands outside the transmit filter are amplified and passed to a detector diode. This diode produces a DC output proportional to the input power. For a conventional radiometer, this level would be digitized. By taking this DC output and mixing it with a system oscillator at 10 MHz, the signal can instead be digitized by a second channel on the radar digital receiver (which typically do not accept DC inputs), and can be down-converted to a DC level again digitally. This unintuitive step allows the digital receiver to sample both the radiometer and radar data at a rapid, synchronized data rate (greater than 1 MHz bandwidth). Once both signals are sampled by the same digital receiver, high-speed quality control can be performed on the radiometer data to allow it to take data simultaneously with the radar. The radiometer data can be blanked during radar transmit, or when the radar return is of a power level high enough to corrupt the radiometer data. Additionally, the receiver protection switches in the RF front end can double as radiometer calibration sources, the short (four-microsecond level) switching periods integrated over many seconds to estimate the radiometer offset. The major benefit of this innovation is that there is minimal impact on the radar performance due to the integration of the radiometer, and the radiometer performance is similarly minimally affected by the radar. As the radar and radiometer are able to operate simultaneously, there is no extended period of integration time loss for the radiometer (maximizing sensitivity), and the radar is able to maintain its full number of pulses (increasing sensitivity and decreasing measurement uncertainty).

McLinden, Matthew↗

Advanced Klystrons for High Efficiency Accelerator Systems (Final Report)

This program explored tailoring of RF pulses used to drive accelerator cavities. Simulations indicated that properly shaping the pulse risetime to match accelerator cavity characteristics reduced reflected power and increased total efficiency. Tailoring the pulse requires a high power, gridded, klystron to shape the risetime while also controlling the beam current. The Phase I program generated a preliminary design of a gridded electron gun for a klystron producing 5-10 MW of RF power. This required design of a segmented cathode using Controlled Porosity Reservoir cathodes to limit power deposition on the grid. The program was successful in computationally designing a gun producing a high quality electron beam with grid control. Additional analysis of pulse tailoring indicated that technique would only be useful for cavity drive pulses that were less than approximately 2-3 times the risetime. Otherwise, the efficiency gained during the risetime of the pulse became insignificant when considering the efficiency over the entire pulse. Consequently, it was determined that a Phase II program would not provide sufficient return to justify the cost. Never the less, other applications for a high power gridded gun are currently being pursued. This klystron, for example, would facilitate development inverse Comptom x-ray sources by providing a high repetition rate (10 -100 kHz) RF source.

43 PARTICLE ACCELERATORS↗

Low cost high efficiency GaAs monolithic RF module for SARSAT distress beacons

Low cost high performance (5 Watts output) 406 MHz beacons are urgently needed to realize the maximum utilization of the Search and Rescue Satellite-Aided Tracking (SARSAT) system spearheaded in the U.S. by NASA. Although current technology can produce beacons meeting the output power requirement, power consumption is high due to the low efficiency of available transmitters. Field performance is currently unsatisfactory due to the lack of safe and reliable high density batteries capable of operation at -40 C. Low cost production is also a crucial but elusive requirement for the ultimate wide scale utilization of this system. Microwave Monolithics Incorporated (MMInc.) has proposed to make both the technical and cost goals for the SARSAT beacon attainable by developing a monolithic GaAs chip set for the RF module. This chip set consists of a high efficiency power amplifier and a bi-phase modulator. In addition to implementing the RF module in Monolithic Microwave Integrated Circuit (MMIC) form to minimize ultimate production costs, the power amplifier has a power-added efficiency nearly twice that attained with current commercial technology. A distress beacon built using this RF module chip set will be significantly smaller in size and lighter in weight due to a smaller battery requirement, since the 406 MHz signal source and the digital controller have far lower power consumption compared to the 5 watt power amplifier. All the program tasks have been successfully completed. The GaAs MMIC RF module chip set has been designed to be compatible with the present 406 MHz signal source and digital controller. A complete high performance low cost SARSAT beacon can be realized with only additional minor iteration and systems integration.

Petersen, W. C.↗

Characterizing the plasma-induced thermal loads on a 200 kW light-ion helicon plasma source via infra-red thermography

The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Furthermore, experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rotational and vibrational temperatures in a hydrogen discharge with a magnetic X-point

A novel plasma source with a magnetic X-point has been developed to probe an alternative for cesium-free negative hydrogen ion production. This study presents first results for the gas and vibrational temperatures in the source at 1 Pa and various RF powers. The temperatures are obtained from analysis of the intensity distribution of the molecular Fulcher-{alpha} bands. The gas temperature increases with the RF power, while the vibrational temperature remains constant in the studied range of RF powers. Both quantities show no appreciable spatial dependence. The obtained high values of the vibrational temperatures indicate a high population of the vibrational levels, favourable for the volume negative ion production. A theoretical concept indicates the presence of an optimum value for the vibrational temperature at which the negative hydrogen ion yield by volume processes has a maximum. Coincidently, the measured value is close to this optimum. This indicates that the novel concept can provide certain advantages compared to other sources based on volume production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerator Sources for THz science: A Review

Free Electron Lasers have been around since 1977 providing not only a test bed for the physics of FELs and electron/photon interactions but as a workhorse of scientific research. More than 30 FELs are presently operating around the world spanning a wavelength range from the millimeter region to the hard x-ray using direct current and rf linear accelerators or storage rings as electron sources. The characteristics that have driven the development of these sources are the desire for high peak and average power, high micropulse energies, wavelength tunability, timing flexibility, and wavelengths that are unavailable from more conventional laser sources. Operation of FELs in the far infrared to terahertz regime poses special challenges which have been and are being addressed at a number of facilities around the world. This paper will review a number of former and existing FELs operating in this regime and discuss future efforts. Broadband collective radiation from relativistic electrons also plays a significant role in the production of FIR/THz radiation and several groups are taking advantage of this source for users. Applications for use of the radiation have evolved from simple imaging to complex pump probe tests of insulator/metal transitions and energy flow in organic molecules. We will discuss the technologies for generating the IR/FIR/THz radiation and cover some of the unique applications of such sources.

43 PARTICLE ACCELERATORS↗

Active cleaning technique device

The objective of this program was to develop a laboratory demonstration model of an active cleaning technique (ACT) device. The principle of this device is based primarily on the technique for removing contaminants from optical surfaces. This active cleaning technique involves exposing contaminated surfaces to a plasma containing atomic oxygen or combinations of other reactive gases. The ACT device laboratory demonstration model incorporates, in addition to plasma cleaning, the means to operate the device as an ion source for sputtering experiments. The overall ACT device includes a plasma generation tube, an ion accelerator, a gas supply system, a RF power supply and a high voltage dc power supply.

Shannon, R. L.↗

Experiences with the Fermilab HINS 325 MHz RFQ

The Fermilab High Intensity Neutrino Source program has built and commissioned a pulsed 325 MHz RFQ. The RFQ has successfully accelerated a proton beam at the design RF power. Experiences encountered during RFQ conditioning, including the symptoms and cause of a run-away detuning problem, and the first beam results are reported.

43 PARTICLE ACCELERATORS↗

Development of diagnostic and manipulation systems for space-charge dominated electron beams and confined electron plasmas in ELTRAP

Modifications have been implemented in the Penning-Malmberg device ELTRAP aimed at performing studies on the dynamics of space-charge dominated nanosecond electron bunches traveling along the magnetic field. In particular, a Thomson backscattering apparatus has been developed where an infrared (IR) laser pulse collides with the bunched electron beam. The frequency-shifted backscattered radiation, acquired by means of a photomultiplier (PMT), can be exploited to evaluate information on energy, energy spread and density of the bunch. The achievable sensitivity of the diagnostics has been estimated, and valuable information on the main parameters affecting the signal-to-noise (S/N) ratio has been obtained [B. Paroli, F. Cavaliere, M. Cavenago, F. De Luca, M. Ikram, G. Maero, C. Marini, R. Pozzoli, and M. Rome, JINST 7, P01008 (2012)]. A series of upgrades are under way, aimed at increasing the S/N ratio through the use of a new laser for the electron source, the insertion of a stray light shield, and the optimization of the detection electronics. Moreover, electromagnetic simulations relevant to the design and implementation of a microwave heating system are presented. The generation of an electron plasma in ELTRAP by means of a low-power radio frequency (RF) drive in the MHz range applied on one of the trap electrodes and under ultra-high vacuum (UHV) conditions has previously been demonstrated [B. Paroli, F. De Luca, G. Maero, F. Pozzoli, and M. Rome, Plasma Sources Sci. Technol. 19, 045013 (2010)]. The new heating system will allow the extension of the RF studies to the GHz range and in particular the production of a more energetic electron plasma via cyclotron resonant excitation.

43 PARTICLE ACCELERATORS↗

Ultralightweight Power System for Human-Portable Linac-Based X-Ray Sources

Industrial human-portable X-ray sources are widely used by security, nuclear safeguard, and defense agencies. However, the employed sources have significant energy, dose, size, weight, and power (SWaP) limitations, greatly affecting their practical application. RF linear accelerators (linacs) can serve as a flexible, reliable, and robust type of X-ray source if they can match the size, weight, cost, and imaging performance requirements of conventional ones. One of the most critical elements affecting these parameters is the high-voltage pulsed power supply system or modulator, which can make the largest contribution to the total weight and dimensions of the accelerator. Here, in this article, we present the design and demonstration results of a novel ultra lightweight power system based on a 24-kV solid-state Marx modulator for a hand-portable 0.15–2.0-MeV Ku -band linac-based X-ray source.

47 OTHER INSTRUMENTATION↗

Understanding carbon sourcing and transport originating from the helicon antenna surfaces during high-power helicon discharge in DIII-D Tokamak

The high-power helicon wave system in the DIII-D tokamak could potentially introduce new plasma–material interaction (PMI) challenges owing to rectified RF sheath potentials that develop near the antenna and surrounding plasma-facing components. We present the first application of the STRIPE (Simulated Transport of RF Impurity Production and Emission) framework to helicon-induced PMIs, extending previous STRIPE studies of ICRH antennas by incorporating net erosion, local re-deposition, and three-dimensional global impurity transport. The integrated workflow couples SOLPS, COMSOL, RustBCA, GITR, and GITRm to simulate carbon erosion, re-deposition, and impurity transport for two experimentally constrained DIII-D H-mode helicon operating scenarios with different antenna–plasma gaps, coupled RF powers, and edge plasma conditions. COMSOL predicts rectified RF sheath potentials of 1–5 kV localized near the lower portion of the antenna, where the magnetic field intersects the surface at grazing incidence. Carbon self-sputtering dominates the erosion source, whereas RF-accelerated D + ions contribute approximately 1% of the total gross erosion. The smaller-gap operating scenario exhibits substantially stronger gross erosion, enhanced local re-deposition (∼12%), and a larger confined carbon inventory owing to increased plasma accessibility and broader RF sheath coverage. Comparison with available DIII-D measurements shows no distinct change in the global carbon signal that correlates with the helicon RF pulse, consistent with the simulations indicating that the helicon-generated carbon source remains small compared with the existing background carbon inventory under the present graphite-wall operating conditions. These results demonstrate the capability of STRIPE to integrate RF sheath modeling, plasma transport, surface interaction physics, and three-dimensional impurity transport for the interpretation of helicon-induced PMIs. The study further identifies the principal sources of modeling uncertainty, including grazing-angle RF sheath physics, slow-wave resolution, plasma-background extrapolation, and trace-impurity transport assumptions, providing a framework for future validation and model development.

Kumar, Atul [Oak Ridge National Laboratory (ORNL),↗

Conceptual Design, Implementation and Commissioning of Data Acquisition and Control System for Negative Ion Source at IPR

Negative ion Experimental facility has been setup at IPR. The facility consists of a RF based negative ion source (ROBIN)--procured under a license agreement with IPP Garching, as a replica of BATMAN, presently operating in IPP, 100 kW 1 MHz RF generators and a set of low and high voltage power supplies, vacuum system and diagnostics. 35 keV 10A H- beam is expected from this setup. Automated successful operation of the system requires an advanced, rugged, time proven and flexible control system. Further the data generated in the experimental phase needs to be acquired, monitored and analyzed to verify and judge the system performance. In the present test bed, this is done using a combination of PLC based control system and a PXI based data acquisition system. The control system consists of three different Siemens PLC systems viz. (1) S-7 400 PLC as a Master Control, (2) S-7 300 PLC for Vacuum system control and (3) C-7 PLC for RF generator control. Master control PLC directly controls all the subsystems except the Vacuum system and RF generator. The Vacuum system and RF generator have their own dedicated PLCs (S-7 300 and C-7 respectively). Further, these two PLC systems work as a slave for the Master control PLC system. Communication between PLC S-7 400, S-7 300 and central control room computer is done through Industrial Ethernet (IE). Control program and GUI are developed in Siemens Step-7 PLC programming software and Wincc SCADA software, respectively. There are approximately 150 analog and 200 digital control and monitoring signals required to perform complete closed loop control of the system. Since the source floats at high potential ({approx}35 kV); a combination of galvanic and fiber optic isolation has been implemented. PXI based Data Acquisition system (DAS) is a combination of PXI RT (Real time) system, front end signal conditioning electronics, host system and DAQ program. All the acquisition signals coming from various sub-systems are connected and acquired by the PXI RT system, through only fiber optics link for signal conditioning, electrical isolation and better noise immunity. Real time and Host application programs are developed in LabVIEW and the data shall be stored with a facility of online display of selected parameters. Mathematical calculations and report generation will take place at the end of each beam shot. The paper describes in detail about the design approach, implementation strategy, program development, commissioning and operational test result of ROBIN through a data acquisition and control system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling the Next Generation of Smart Sensors in Coal Fired Power Plants using Cellular 5G Technology

An important need for coal fired power plants is the ability to monitor multiple systems with ease and accuracy. Common implementations of these monitoring systems come with drawbacks due to the nature of coal fired power plants. Harsh environments, High Temperatures, and lots of RF (Radio Frequency) noise can create issues for accurately recording and transmitting data across wireless signals. In addition, as renewable energy sources come online, existing fossil fueled plants will need to operate more flexibly with their maintenance schedules outside of standard conditions. Therefore, additional sensing and control mechanisms need placed in existing plants to provide operators with more information such that maintenance decisions can be made well in advance of failures. A solution to this problem is the Next Generation of Smart Sensors, which leverages the power of 5G cellular signals and machine learning to overcome the myriad of problems with current implementations

20 FOSSIL-FUELED POWER PLANTS↗