Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Insulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Sudden-Discharge Cycling Characteristics and Millisecond Dynamic Behaviors of a HTS Stainless-Steel Insulated Double-Pancake Coil With Thin Copper Plates

We have tested an intermediate-sized HTS stainless-steel (co-wound) insulated double pancake coil (~132 turns per coil) and discovered dynamic effects during sudden discharge on both millisecond and second scales. For soft break, the power supply is turned off suddenly but the shunt resistor (164 milliohm) is still connected; for hard break, a high voltage contactor is used to suddenly open the circuit so that the leads are completely open. Hard break is dangerous to traditionally insulated LTS magnets, but the SS-insulated HTS DPC retained integrity over ¡80 charge-discharge cycles. Voltage decay curves for soft and hard breaks are studied on short and long timescales. On long timescales, we observe the expected exponential decay and measure the time constant to calculate contact resistance. On short timescales, we observe highly dynamic effects: a hyper-exponential decay suggesting that the inductance or contact resistance is suddenly changing with time, likely an indication of the RL circuit forming. Moreover, peak voltage immediately (ms) after the sudden discharge were collected and compared. It is found that the peak voltage in soft-discharge is proportional to the applied current, while the those in hard-break has a unique pattern and tends to stay flat even though the applied current increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Online Detection of Inter-Turn Winding Faults in Single-Phase Distribution Transformers Using Smart Meter Data

Turn-to-turn faults between primary windings due to insulation degradation are a major cause of distribution transformer failure, and occur due to high levels of stress such as overloading and overheating. An additional consequence of these faults is an increased voltage on the transformer secondary due to effective change in turns ratio. This paper develops a novel method for early detection of insulation degradation and subsequent inter-turn winding failure by monitoring the transformer secondary voltage. The algorithm is based on a cumulative sum (CUSUM) statistic and compares voltages on neighbouring transformers to flag degrading assets. Results obtained from simulation as well as experimental data show that smart meter measurements can be utilized to achieve very high detection accuracy while keeping costs low. Here, the paper also demonstrates the validity of the algorithm in the presence of measurement noise, residential solar power injection etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LANSCE Module 1 Capacitor Room Failure [Slides]

At ~3:30 am on Sunday, high-voltage line in capacitor room overheated to the extent that the poly insulating material caught fire and dripped melted insulation onto equipment below. LAFD responded and, per pre-incident planning, waited for AOT personnel to respond to the area. AOT personnel, safed equipment and waited with LAFD for fire to “burn out”. Using an IWD, AOT personnel safely re-entered the area after conducting hazards analysis and engaging SMEs, re: controls for combustion products and COVID-19 hazards. Recovery action took several days with a focus on getting it right. Beam re-start decisions were made with impacted organizations and considering AOTRFE personnel.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ceramic materials purified by experimental method

Crystalline ceramic materials are purified for use as high-temperature electrical insulators. Any impurities migrate to the cathode when a dc voltage is applied across the material while it is heated in an inert gas atmosphere.

Source record↗

Electrical safety requirements: Implications for the module designer

Commercial photovoltaic array installations, which include residential and intermediate applications, are subject to building and electrical codes and to product safety standards. The National Electrical Code (NEC) Article 690, titled Solar Photovoltaic Systems, contains provisions defining acceptable levels of system safety and emphasizes the system design and its installation. The Underwriters Laboratories, Inc. (UL), document titled: Proposed First Edition of the Standard for Flat Plate Photovoltaic Modules and Panels, UL-1703, identifies module and panel construction requirements that ensure product safety. Together these documents describe requirements intended to minimize hazards such as shock and fire. Although initial focus of these requirements is on single crystal silicon modules, they are generic in nature, and are equally applicable to high voltage ( 30 Vdc), multikilowatt, thin film systems. A major safety concern is insulation breakdown within the module or array wiring system, or discontinuities within the electrical conductors. These failures can result in ground faults, in circuit arcs, or exposure to hazardous electrical parts. Safeguards are discussed.

Sugimura, R. S.↗

High-Voltage Switch Containing (DI)2 Devices

Series switching diodes triggered on by passing above threshold voltage. High-voltage switch made by connecting multitude of deep-impurity, double-injection devices in series with each other and with another, triggerable high-voltage device such as thyristor. Device operates near ground potential to avoid insulation problems in triggering circuit.

Hanes, Maurice H.↗

Piezoelectrostatic Generator

High voltage generated by compact, lightweight equipment. Improved variable-capacitance electrostatic generator relies on piezoelectric effort to convert mechanical energy directly into electrical energy and contains neither transformers nor bulky high-voltage rectifiers. Requires neither external power supply to charge, nor vacuum to insulate electrodes.

Robertson, Glen A.↗

Proposed Modifications to Engineering Design Guidelines Related to Resistivity Measurements and Spacecraft Charging

A key parameter in modeling differential spacecraft charging is the resistivity of insulating materials. This determines how charge will accumulate and redistribute across the spacecraft, as well as the time scale for charge transport and dissipation. Existing spacecraft charging guidelines recommend use of tests and imported resistivity data from handbooks that are based principally upon ASTM methods that are more applicable to classical ground conditions and designed for problems associated with power loss through the dielectric, than for how long charge can be stored on an insulator. These data have been found to underestimate charging effects by one to four orders of magnitude for spacecraft charging applications. A review is presented of methods to measure the resistive of highly insulating materials, including the electrometer-resistance method, the electrometer-constant voltage method, the voltage rate-of-change method and the charge storage method. This is based on joint experimental studies conducted at NASA Jet Propulsion Laboratory and Utah State University to investigate the charge storage method and its relation to spacecraft charging. The different methods are found to be appropriate for different resistivity ranges and for different charging circumstances. A simple physics-based model of these methods allows separation of the polarization current and dark current components from long duration measurements of resistivity over day- to month-long time scales. Model parameters are directly related to the magnitude of charge transfer and storage and the rate of charge transport. The model largely explains the observed differences in resistivity found using the different methods and provides a framework for recommendations for the appropriate test method for spacecraft materials with different resistivities and applications. The proposed changes to the existing engineering guidelines are intended to provide design engineers more appropriate methods for consideration and measurements of resistivity for many typical spacecraft charging scenarios.

Dennison, J. R.↗

Results of a 2000 hour wear test of the NEXIS ion engine

The Nuclear Electric Xenon Ion System (NEXIS) ion thruster was developed for potential outer planet robotic missions under NASA's Prometheus program. This engine was designed to operate at power levels ranging from 16 to over 20 kWe at specific impulses of 6000 to 7500 s for burn times of up to 10 years, satisfying the requirements of nuclear electric propulsion systems such as that on the proposed Prometheus 1 mission to explore the icy moons of Jupiter. State-of-the-art performance and life assessment tools were used to design the thruster. Following the successful performance validation of a Laboratory Model thruster, Development Model hardware was fabricated and subjected to vibration and wear testing. The results of a 2000-hour wear test are reported herein. Thruster performance achieved the target requirements and was steady for the duration of the test. Ion optics performance was similarly stable. Discharge loss increases of 6 eV/ion were observed in the first 500 hours of the test and were attributed to primary electron energy decreases due to cathode insert conditioning. Relatively high recycle rates were observed and were identified to be high-voltage-to-ground arcs in the back of the thruster caused by wire insulation outgassing and electron penetration through the plasma screen. Field emission of electrons between the accelerator and screen grids was observed and attributed to evolution of field emitter sites at accelerator grid aperture edges caused by ion bombardment. Preliminary modeling and analysis indicates that the NEXIS engine can meet mission performance requirements over the required lifetime. Finally, successful validation of the NEXIS design methodology, design tools, and technologies with the results of the wear test and companion performance and vibration tests presents significant applicability of the NEXIS development effort to missions of near-term as well as long-term interest for NASA.

Nuclear Electric Xenon Ion System (NEXIS)Thruster ↗

Results of a 2000 Hour Wear Tof the NEXIS Ion Engine

The Nuclear Electric Xenon Ion System (NEXIS) ion thruster was developed for potential outer planet robotic missions under NASA's Prometheus program. This engine was designed to operate at power levels ranging from 16 to over 20 kWe at specific impulses of 6000 to 7500 s for burn times of up to 10 years, satisfying the requirements of nuclear electric propulsion systems such as that on the proposed Prometheus 1 mission to explore the icy moons of Jupiter. State-of-the-art performance and life assessment tools were used to design the thruster. Following the successful performance validation of a Laboratory Model thruster, Development Model hardware was fabricated and subjected to vibration and wear testing. The results of a 2000-hour wear test are reported herein. Thruster performance achieved the target requirements and was steady for the duration of the test. Ion optics performance was similarly stable. Discharge loss increases of 6 eV/ion were observed in the first 500 hours of the test and were attributed to primary electron energy decreases due to cathode insert conditioning. Relatively high recycle rates were observed and were identified to be high-voltage-to-ground arcs in the back of the thruster caused by wire insulation outgassing and electron penetration through the plasma screen. Field emission of electrons between the accelerator and screen grids was observed and attributed to evolution of field emitter sites at accelerator grid aperture edges caused by ion bombardment. Preliminary modeling and analysis indicates that the NEXIS engine can meet mission performance requirements over the required lifetime. Finally, successful validation of the NEXIS design methodology, design tools, and technologies with the results of the wear test and companion performance and vibration tests presents significant applicability of the NEXIS development effort to missions of near-term as well as long-term interest for NASA.

Thruster performance↗

Thermal Assessment and In-Situ Monitoring of Insulated Gate Bipolar Transistors in Power Electronic Modules: Preprint

Insulated gate bipolar transistor (IGBT) power modules are devices commonly used for switching of high voltages and currents. Usage and environmental conditions can cause these power modules to degrade over time, and this gradual process may eventually lead to catastrophic failure of the device. This degradation process may cause some early performance symptoms related to the state of health of the power module, making it possible to detect reliability degradation of the IGBT module. Testing can be used to accelerate this process, permitting a rapid determination of whether specific declines in device reliability can be characterized. In this study, thermal cycling was conducted on multiple power modules simultaneously in order to assess the effect of thermal cycling on the degradation of the power module. In-situ monitoring of temperature was performed from inside each power module using high temperature thermocouples. Device imaging and characterization was performed along with temperature data analysis, to assess failure modes and mechanisms within the power modules. While the experiment was aimed to assess the potential damage effects of thermal cycling on die attach, results indicated that wirebond degradation was the life limiting failure mechanism.

33 ADVANCED PROPULSION SYSTEMS↗

Assessment of EPRI’s Tan Delta Approach to Manage Cables in Submerged Environments: Statistical Review of EPRI Data

Research conducted by the Electric Power Research Institute (EPRI) and other research institutions have concluded that water-trees are one of the leading degradation mechanisms that contribute to the loss of dielectric insulation strength in medium-voltage cable insulating materials in wet or submerged environments. The electrochemical reactions are caused by the combined effect of water presence and relatively high electrical stress. Records of cable failures provided by the licensees in response to Generic Letter (GL) 2007-01 (NRC 2007) have called into question the reliability of medium voltage cables in wetted or submerged environments. EPRI’s dissipation factor or Tan Delta testing guidelines and acceptance criteria have been adopted by most nuclear power plant operators as the primary tool for condition monitoring of medium voltage cables in wet or submerged environments. EPRI has been collecting member data since late 2009 to analyze and provide feedback to members, validate the EPRI-developed acceptance criteria guidelines, support analysis of test results, recommend appropriate actions for the "action required" category, and gather candidate cables for EPRI-sponsored forensic research on causes for insulation degradation. EPRI has collected data from 37 nuclear sites, which represent 44 operating units. The test results have been organized by insulation type, such as cross-linked polyethylene (XLPE); butyl rubber; black, pink, and brown ethylene-propylene rubber (EPR); and compact insulation (black and pink EPR)1. The data have been analyzed, and follow-up information was obtained from members for “action required” test results. EPRI has also performed correlations between Tan Delta tests and the information gathered under the EPRI forensic research on medium-voltage cables. In addition, EPRI has developed guidance by cable insulation type on how to systematically analyze Tan Delta test results. The analysis described here reviewed the two primary EPRI reports (EPRI 3002000557 and EPRI 3002005321) as well as two precedent EPRI reports (EPRI 1028262 and EPRI 1021070) that were cited in the primary reports. The principal results and conclusions from the project analyses are provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study of the Heater-Coil Electrical Insulation for the HL-LHC Low Beta Quadrupoles

In the framework of the HL-LHC project, the present LHC low-β superconducting quadrupoles will be substituted with higher performance Nb 3 Sn magnets (MQXF) with 11.4 T coil peak field. MQXF coils are impregnated with epoxy resin to reduce risk of stress concentration on the brittle conductor. The magnet quench protection is provided by CLIQ and quench heaters to ensure a redundant system. Quench heaters are impregnated with the coils in order to have suitable thermal contact with them, and to prevent the hot spot temperature from exceeding 350K during normal operation in case of a quench. Quench heaters are insulated from the coil by S-2 Glass and polyimide. Here, the test of the first MQXF prototype (4 m long) MQXFAP1 was stopped by a coil-to-ground short circuit triggered by a heater-to-coil short. This issue triggered a root analysis of the causes of this short. Here we prove that the use of a non-conforming cloth in coil impregnation, further weakened by non-conforming high voltage test, has triggered the shorts. Moreover, we present an analysis of the heater-to-coil insulation strength, showing the role of blistering phenomena and how they are triggered by a combination of magnet powering and heater firing.

43 PARTICLE ACCELERATORS↗

Heterogeneous Integration of Flipped Oxide Heterostructure Membranes for Nanoelectronics

Freestanding complex oxide membranes enable the release and transfer of epitaxial films, offering new design freedoms for next‐generation electronics. While the LaAlO 3 /SrTiO 3 (LAO/STO) heterostructure exhibits remarkable tunable conductivity at its interface, the active interface remains buried beneath the substrate, limiting access to this functionality. Here, we demonstrate how the LAO/STO heterostructure, in membrane form, can be flipped and precisely positioned on silicon and other platforms using polymer‐free micromanipulation. The transferred membranes preserve atomically smooth surfaces, high crystallinity, and key electronic properties. Through the 44‐nm insulating STO layer, ultra‐low‐voltage electron‐beam lithography (ULV‐EBL) writes conductive nanostructures at the now‐accessible STO/LAO interface, offering the potential to function as programmable local gates that modulate charge carriers in the underlying silicon. The platform establishes a general strategy for integrating complex oxide heterostructures with semiconductors, quantum materials, and flexible substrates, enabling new architectures for reprogrammable nanoelectronic devices.

36 MATERIALS SCIENCE↗

Automated plotting of equipotentials

By substitution of resistance paper for normal plotting paper, an x-y plotter can be used to draw automatically the equipotential lines between components represented in planar form on the paper. This technique is used for high voltage electronic components of complex configuration for the prediction of stress in the intervening insulation.

Bunker, E. R., Jr.↗

Solar array experiments on the Sphinx satellite

The Space Plasma, High Voltage Interaction Experiment (SPHINX) is the name given to an auxiliary payload satellite scheduled to be launched in January 1974. The principal experiments carried on this satellite are specifically designed to obtain the engineering data on the interaction of high voltage systems with the space plasma. The classes of experiments are solar array segments, insulators, insulators with pin holes and conductors. The satellite is also carrying experiments to obtain flight data on three new solar array configurations; the edge illuminated-multijunction cells, the Teflon encased cells and the violet cells.

Stevens, N. J.↗

Solar array experiments on the SPHINX satellite

The Space Plasma, High Voltage Interaction Experiment (SPHINX) is the name given to an auxiliary payload satellite scheduled to be launched in January 1974. The principal experiments carried on this satellite are specifically designed to obtain the engineering data on the interaction of high voltage systems with the space plasma. The classes of experiments are solar array segments, insulators, insulators with pin holes and conductors. The satellite is also carrying experiments to obtain flight data on three new solar array configurations: the edge illuminated-multijunction cells, the teflon encased cells, and the violet cells.

Stevens, N. J.↗